ADM3485EAN - 3.3V 20Mbps RS-485/422 Transceiver | ADI
部品番号: ADM3485EAN ✓ 生産中ADM3485EAN 概要
An RS-485/RS-422 transceiver is an interface IC that converts logic-level signals into balanced differential signals for reliable communication over longer cables. A differential receiver rejects common-mode noise, while the transceiver family connects equipment through bidirectional bus wiring. The ADM3485E belongs to the broader line-driver and receiver hierarchy within interface ICs, providing physical-layer signaling for multipoint networks.
Key features include operation from a 3.3 V supply, a 20 Mbps maximum data rate, 15 kV ESD protection, and compliance with TIA/EIA RS-422 and RS-485 standards over the full common-mode range. The device supports half-duplex operation and a 19 kΩ input impedance, allowing up to 19 transceivers on a bus. Low-power operation is important in distributed equipment because each node continuously contributes to the total bus loading.
The ADM3485E architecture combines a differential driver, differential receiver, driver-enable control, and receiver-enable control in one package. Driver and receiver enables support directional control on half-duplex networks. Short-circuit protection improves robustness when a bus driver drives into a fault condition, while the specified ESD protection helps protect the transceiver pins during handling and cable-side transients.
Typical applications include industrial RS-485 buses, building and factory automation networks, instrumentation links, industrial gateways, and embedded communications equipment. The 20 Mbps capability supports high-speed short-distance links, while the balanced interface and 19 kΩ input impedance are useful when multiple nodes share a bus. External protection may still be required for severe industrial surge environments.
For PCB design, place the transceiver close to the connector and bus interface, keep differential traces closely coupled, and provide the bypass capacitance and termination required by the bus topology. Avoid adding excessive capacitance to driver and receiver inputs. Do not substitute the RS-422 and RS-485 termination or biasing arrangements without checking the bus configuration.
This product page combines the Analog Devices device description, package information, cross-reference candidates, practical bus-design guidance, and parameter-level comparisons to simplify transceiver selection and PCB implementation.
ドロップイン代替品: ADM3485EAN — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: ADM3485EAN (同一形状・フットプリント) — 相違点: Mounting Type, Package, Product Type, Driver Architecture, ESD Protection.
ADM3485EANZ
✅ ドロップイン📋 参考代替品(カタログ未掲載)
ADM3485ARZ
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MAX3485CPA+
✅ ドロップイン価格はお問い合わせください
データシートを見る →MAX3485ECPA+
✅ ドロップイン価格はお問い合わせください
データシートを見る →ADM3485EAN 仕様
| Product Type | RS-485/RS-422 differential transceiver |
| 電源電圧 | 3.3 V |
| Maximum Data Rate | 20 Mbps |
| Communication Mode | Half-duplex |
| ESD Protection | 15 kV |
| Standards Compliance | TIA/EIA RS-422 and RS-485 |
| Common-Mode Range | Full common-mode range |
| Receiver Input Impedance | 19 kΩ |
| Maximum Transceivers on Bus | 19 transceivers |
| Driver and Receiver Enable | Yes |
| Short-Circuit Protection | Yes |
| Supply Class | Low-power 3.3 V transceiver |
| パッケージ | 8-pin SOIC |
| 実装タイプ | Surface mount |
ADM3485EAN 8-pin soic ピン配置ガイド
ADM3485EAN (8-pin soic パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: ADM3485EAN.
詳細は データシート をご参照ください。
主な用途
ADM3485EAN の用途: 6 件s: Industrial RS-485 Automation Bus, Factory Sensor and Actuator Network, Industrial Communications Gateway, Building Automation Equipment, Test and Measurement Instrumentation, Embedded RS-485 Control Module.
Industrial RS-485 Automation Bus
The ADM3485EAN is appropriate for an industrial half-duplex RS-485 bus because it combines a 3.3 V low-power interface with a 20 Mbps maximum data rate and TIA/EIA RS-485 compliance over the full common-mode range. Its 19 kΩ receiver input impedance allows up to 19 transceivers on the bus, which supports distributed controller, sensor, and actuator nodes. The 15 kV ESD rating improves robustness at connector-adjacent equipment, although external surge protection may still be required for severe environments. Firmware should control driver and receiver enables to prevent multiple drivers from transmitting simultaneously, and the bus should use the prescribed biasing and termination arrangement.
おすすめ
Factory Sensor and Actuator Network
The ADM3485EAN can connect factory sensors, remote I/O modules, and actuator controllers over a shared balanced bus. Its 19 kΩ input impedance supports as many as 19 transceivers, while the 20 Mbps capability allows high-speed communication over shorter field-run distances. Half-duplex operation simplifies wiring by sharing driver and receiver paths, but firmware must enforce turnaround timing so the bus is not driven while another node transmits. Place the transceiver near the field connector, route the differential pair as a tightly coupled pair, and validate the complete network with realistic cable length, node count, common-mode offset, and termination.
おすすめ
Industrial Communications Gateway
The ADM3485EAN suits gateways that translate between a host processor and an RS-485 field network. A 3.3 V supply minimizes power requirements in embedded equipment, while the 20 Mbps rate provides ample bandwidth for control messages and status updates. The 19 kΩ input impedance allows a gateway to coexist with other nodes on a multipoint bus without imposing excessive loading. Driver-enable and receiver-enable signals should be controlled by the host interface to establish clear bus direction. The SOIC package also supports compact implementations, but careful ground-plane continuity and connector-side protection remain important for industrial reliability.
おすすめ
Building Automation Equipment
The ADM3485EAN can implement the physical layer for building automation controllers, room modules, and environmental monitoring units. Half-duplex RS-485 wiring supports economical multidrop cabling, and the low-power 3.3 V operation is useful in distributed building equipment. The 15 kV ESD protection is especially relevant when transceiver circuits are connected to field wiring, although installation transients may justify dedicated surge protection. Configure termination only at the physical ends of the bus, apply biasing consistently, and avoid long stub branches. A 20 Mbps link is best used on shorter in-building runs, with cable length and topology evaluated against the actual channel requirements.
おすすめ
Test and Measurement Instrumentation
The ADM3485EAN is suitable for test and measurement equipment that uses a short, high-speed balanced link between an instrument controller and remote front end. The 20 Mbps data rate supports fast command and measurement traffic, while differential signaling improves noise immunity compared with a single-ended interface. Its 19 kΩ receiver input impedance minimizes loading when several instrument modules share a bus. Keep the differential trace pair closely coupled, provide a continuous ground reference, and place the device near the connector to minimize vulnerable stub length. Where safety or severe EFT exposure is expected, add the appropriate external protection rather than relying only on the internal 15 kV ESD rating.
おすすめ
Embedded RS-485 Control Module
The ADM3485EAN works well in embedded control modules that expose a 3.3 V RS-485 port for motors, relays, remote I/O, or remote sensors. The low-power 3.3 V architecture supports compact embedded systems, and the 8-pin SOIC package simplifies assembly. Half-duplex control requires the firmware to arbitrate transmit and receive states, with protection against simultaneous driver activation. For reliable operation, use the manufacturer’s recommended bypass and bus components, keep the bus pair away from switching nodes, and maintain a continuous reference plane beneath the pair. The 20 Mbps capability is useful for short cabinet links but does not eliminate the need to evaluate field-cable attenuation and noise.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ADM3485EAN — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | ADM3485EANZ | ADM3485ARZ | MAX3485CPA | MAX3485ECPA |
|---|---|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Maxim Integrated | Maxim Integrated |
主な差別化要因
- Documented 20 Mbps maximum data rate (vs MAX3485CPA)
- 15 kV ESD protection (vs ADM3485ARZ)
- 19-node bus capability (vs MAX3485ECPA)
設計ノート
Route the RS-485 differential pair as a tightly coupled pair with continuous, uninterrupted return paths. Keep the transceiver close to the connector, minimize stubs, and avoid routing the pair alongside high-current switching nodes. A solid ground reference beneath the pair improves noise immunity and reduces the likelihood that differences in trace impedance distort the differential signal.
Do not allow multiple nodes to enable their drivers simultaneously. The ADM3485EAN supports half-duplex operation, so driver-enable and receiver-enable sequencing must be controlled by the host firmware or hardware. Include adequate bus-turnaround time before asserting the driver and before interpreting received data; otherwise, a node may mistake its own transmitted signal for a response.
Use the bus topology and termination scheme appropriate for the selected RS-485 or RS-422 network. Termination belongs at the physical ends of the bus, while biasing establishes the correct idle state where required. Avoid placing unnecessary termination across every node, because excess loading can reduce signal margin. Validate the completed board with the intended cable, node count, grounding arrangement, and common-mode conditions.
The 15 kV ESD rating does not by itself define protection against every industrial surge event. Add external surge-protection devices when the cable can experience severe lightning or switching transients beyond the transceiver’s specified withstand. Select the protection network so that it does not distort the 20 Mbps edge rate or increase bus capacitance, and connect its return path to the appropriate chassis or signal-ground structure.
コンプライアンス情報
No definitive component-level RoHS, REACH, lead-free, halogen-free, or conflict-minerals status was identified. AEC-Q100 qualification is not indicated for this interface transceiver.