Texas Instruments

ADS8681IPW - 16-Bit 1-MSPS SAR ADC | Texas Instruments

部品番号: ADS8681IPW ✓ 生産中
5 V Vdss 16-TSSOP, 0.173 inch (4.40 mm) body width Package
MOQ: 1 |

ADS8681IPW 概要

The Texas Instruments ADS8681IPW is a 16-bit, single-channel successive-approximation analog-to-digital converter with a maximum sampling rate of 1 MSPS, programmable bipolar input ranges of ±12 V, ±10 V, ±6 V, ±5 V, and ±2.5 V, and a 16-pin TSSOP package. It operates from a 5 V supply and integrates a 4.096 V reference with low temperature drift.

An analog-to-digital converter is a data-acquisition IC that converts an analog voltage into a numeric code for processing by a microcontroller, FPGA, or industrial controller. The ADS8681 belongs to the SAR ADC hierarchy, where a successive-approximation internal DAC determines the input voltage during each conversion. It also belongs to the broader ADC, data-converter, and semiconductor categories, making it suitable for precision measurement systems that must accept high-voltage industrial signals.

Key features include 16-bit resolution, a 1 MSPS conversion rate, one analog input channel, and programmable input ranges extending to ±12 V. The integrated analog front end accepts bipolar industrial signals, while the overvoltage-protection circuit extends tolerance to ±20 V. An on-chip 4.096 V reference provides the conversion baseline and is specified as having extremely low temperature drift. The device also uses an integrated reference and input-driver structure to simplify acquisition-circuit design.

The 5 V single-supply architecture supports compact mixed-signal designs where the analog input can exceed the supply rails. The SAR conversion principle provides predictable sampling behavior, while the programmable input ranges allow one board design to cover several conventional voltage classes. Its 16-TSSOP package has a 0.173 inch, 4.40 mm body width, and the IPW ordering option is supplied in a tube according to the product listing.

Typical applications include industrial process-control instrumentation, factory data acquisition, PLC analog-input modules, power-system monitoring, laboratory measurement equipment, and embedded data-logging systems. The ±12 V input capability is particularly useful when the source is a transducer or sensor-conditioning circuit rather than a ground-referenced 0-to-5 V signal.

The main design consideration is analog conditioning. Place input filtering close to the ADC pins, use the manufacturer’s recommended reference and supply bypassing, and account for the input-filter bandwidth limitation identified in TI’s support material. Check settling behavior and acquisition timing before sampling signals whose frequency approaches the converter’s 1 MSPS capability.

This page combines the manufacturer’s device information with package details, practical implementation guidance, application guidance, and a parameter-by-parameter comparison with pin-compatible ADS868x options. It is intended to help engineers assess package reuse, input-range compatibility, acquisition timing, and production sourcing before selecting the ADS8681IPW.

ドロップイン代替品: ADS8681IPW — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

ADS8685IPW

✅ ドロップイン ⚠️ 仕様未検証
📦 16-TSSOP
Same 16-bit, 1-MSPS ADS868x architecture and 16-TSSOP footprint; programmable input-range set differs from ADS8681

📋 参考代替品(カタログ未掲載)

ADS8689IPW

✅ ドロップイン ⚠️ 仕様未検証
📦 16-TSSOP
Same 16-bit, 1-MSPS ADS868x architecture and 16-TSSOP footprint; programmable input-range set differs from ADS8681

📋 参考代替品(カタログ未掲載)

ADS8681IPWR

✅ ドロップイン
📦 16-TSSOP
Identical ADS8681 electrical function and footprint; ADS8681IPWR uses reel packing while ADS8681IPW uses tube packing

📋 参考代替品(カタログ未掲載)

ADS8681IPW 最大定格&電気的特性

ADC Type Successive-approximation SAR ADC
分解能 16 bit
Maximum Sampling Rate 1 MSPS
Number of Analog Input Channels 1 channel
Programmable Input Ranges ±12 V, ±10 V, ±6 V, ±5 V, and ±2.5 V
Analog Supply Voltage 5 V
Internal Reference Voltage 4.096 V
Reference Temperature Drift Extremely low; exact value not stated
Overvoltage Protection Up to ±20 V
Analog Front End Integrated input-driver circuit
パッケージ 16-TSSOP, 0.173 inch (4.40 mm) body width
実装タイプ Surface mount
Ordering Package Tube

ADS8681IPW tube ピン配置ガイド

ADS8681IPW (tube パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。

ADS8681IPW の tube パッケージピン配置図

詳細なピン配置データはありません: ADS8681IPW.

詳細は データシート をご参照ください。

主な用途

ADS8681IPW の用途: 6 件s: Industrial Process Measurement, PLC Analog Input Module, Factory Automation Data Acquisition, Power-System Monitoring, Laboratory Instrumentation, Embedded Sensor Logging.

🏭

Industrial Process Measurement

The ADS8681IPW suits process-control inputs where a sensor or transmitter produces a bipolar industrial voltage rather than a low-level 0-to-5 V signal. Its programmable ranges include ±12 V, ±10 V, ±6 V, ±5 V, and ±2.5 V, while 16-bit resolution preserves fine numerical distinctions in the converted result. Place the selected input-range network and filtering close to the converter, and use the integrated 4.096 V reference to establish a stable conversion baseline. The 1 MSPS SAR rate provides margin for supervisory measurements while the ±20 V overvoltage capability helps manage transients encountered around industrial wiring.

🏭

PLC Analog Input Module

The ADS8681IPW can form the analog front end of a PLC or remote I/O module that must monitor bipolar plant signals. Its 16-TSSOP package supports compact board layouts, and the 1 MSPS conversion rate is more than adequate for many continuously monitored process variables. The broad range-selection options allow the same converter family to cover voltage levels commonly encountered in automation cabinets. Engineers should place protection and input filtering at the connector, keep those high-impedance analog traces short, and separate them from digital communication traces to preserve conversion quality.

🏭

Factory Automation Data Acquisition

Factory systems often combine slow-changing sensor values with occasional high-speed diagnostics, making the ADS8681IPW a useful channel converter when 16-bit precision is more important than maximum throughput. The single-channel SAR architecture performs deterministic successive-approximation conversion at up to 1 MSPS and includes the analog input driver needed for direct acquisition-system implementation. A practical design can select the correct bipolar range in hardware, acquire the code over the serial interface, and periodically check the status signals. Filtering should be sized against both the 1 MSPS conversion capability and the lower 15 kHz analog bandwidth identified by TI support material.

⚡

Power-System Monitoring

The ADS8681IPW can digitize bipolar voltage-monitoring signals used in power-control and laboratory systems where the measured quantity may exceed the 5 V supply. Programmable input ranges up to ±12 V reduce the need for a separate attenuator, and the integrated 4.096 V reference avoids an additional precision reference component in basic designs. The converter’s 16-bit resolution provides 65,536 code levels, allowing small changes in a conditioned measurement to remain distinguishable. Protection components, isolation boundaries, reference grounding, and safety-rated PCB spacing remain system-level requirements and should not be inferred from the ADC’s ±20 V input tolerance.

🔧

Laboratory Instrumentation

The ADS8681IPW is appropriate for compact laboratory instruments that acquire bipolar voltage measurements with moderate bandwidth. Its 16-bit resolution, integrated reference, and selectable voltage ranges reduce the component count compared with a discrete ADC and reference design. The SAR conversion process can provide a straightforward acquisition sequence for a microcontroller-controlled instrument. For oscilloscope-like measurements, use an external front end with suitable attenuation and bandwidth; the ADC’s 15 kHz analog-filter limitation means higher-frequency waveforms require additional design work rather than direct connection to the input pin.

🧩

Embedded Sensor Logging

Battery-powered or embedded monitoring systems can use the ADS8681IPW when a sensor produces a bipolar voltage and the logger needs higher resolution than an 8- or 12-bit converter. The integrated reference and analog driver reduce external circuitry, while the 16-pin TSSOP package supports compact assembly. Program the range that best uses the converter’s conversion span, and condition the sensor output close to the ADC to minimize noise pickup. The same device can capture slow environmental signals with substantial numerical resolution, although the complete system’s power budget and sampling interval should account for the 5 V analog supply and external interface circuitry.

What is the ADS8681IPW and what are its key specifications?
The ADS8681IPW is a 16-bit, single-channel SAR analog-to-digital converter capable of 1 MSPS operation. According to the Texas Instruments ADS8681 product information, it operates from a 5 V supply and supports programmable bipolar input ranges of ±12 V, ±10 V, ±6 V, ±5 V, and ±2.5 V. It is packaged in a 16-pin TSSOP and includes a 4.096 V on-chip reference, an integrated input driver, and overvoltage protection to ±20 V.
Where can I download the ADS8681IPW datasheet PDF?
The official ADS8681 datasheet is available from Texas Instruments at https://www.ti.com/lit/gpn/ADS8681. The device-specific ordering information also appears at https://www.ti.com/product/ADS8681/part-details/ADS8681IPW. These official pages provide the pin-description table, electrical characteristics, recommended application circuit, and ordering details needed to verify the ADS8681IPW footprint and operating limits before layout.
Where can I find the ADS8681IPW pinout?
The ADS8681IPW pinout is shown in the pin-configuration and pin-description tables of the official Texas Instruments ADS8681 datasheet. The package is a 16-pin TSSOP, and the manufacturer’s diagram should be used to assign every PCB land because signal, power, ground, and control functions must follow the exact numbered package. The official product page at https://www.ti.com/product/ADS8681 provides access to the same technical documentation and ordering information.
What input voltage range can the ADS8681IPW measure?
The ADS8681IPW can measure five programmable bipolar ranges: ±12 V, ±10 V, ±6 V, ±5 V, and ±2.5 V. According to the Texas Instruments ADS8681 product information, the selected range determines how the analog input is scaled for conversion. This makes the device suitable for industrial sensors and process-control signals that exceed the 5 V device supply, provided the input network and protection scheme follow the manufacturer’s application guidance.
How fast can the ADS8681IPW sample an analog signal?
The ADS8681IPW supports a maximum sampling rate of 1 MSPS with 16-bit resolution. The Texas Instruments ADS8681 datasheet identifies it as a high-speed SAR ADC, while TI support material notes that its analog input-filter bandwidth is limited to 15 kHz. Therefore, 1 MSPS describes the converter’s maximum conversion capability; practical signal bandwidth and settling requirements can be substantially lower and should be verified in the acquisition circuit.
What is the difference between ADS8681 and ADS8685?
Both devices belong to the TI ADS868x family and use the same integrated SAR ADC and analog front-end architecture, but their programmable input-range choices differ. The ADS8681 supports ±12 V, ±10 V, ±6 V, ±5 V, and ±2.5 V, while the ADS8685 uses a different set of bipolar ranges. Choose ADS8685 when its range set meets the acquisition requirement; otherwise retain ADS8681 for its broader range-selection options.
What is the difference between ADS8681IPW and ADS8681IPWR?
ADS8681IPW and ADS8681IPWR identify the same ADS8681 device but use different orderable packaging configurations. ADS8681IPW is associated with tube packing, while ADS8681IPWR denotes the tape-and-reel shipping format. The electrical converter specifications remain those of ADS8681, including 16-bit resolution and 1 MSPS operation. This is a packaging distinction rather than a different ADC function, but the reel code must match the board-assembly process.
When should I choose ADS8681IPW instead of ADS8685IPW?
Choose ADS8681IPW when the signal plan requires one of its five programmable bipolar ranges: ±12 V, ±10 V, ±6 V, ±5 V, or ±2.5 V. Choose ADS8685IPW instead when the application can operate with the ADS8685 range set and retains the same family packaging approach. The decision should be based on input amplitude, required resolution, sampling speed, and software range configuration rather than package similarity alone.
Is ADS8681IPW suitable for industrial process-control measurements?
Yes, ADS8681IPW is suitable for many industrial process-control measurements because it accepts bipolar inputs up to ±12 V, provides 16-bit resolution, and integrates a 4.096 V reference. Its 1 MSPS SAR architecture also supports acquisition systems that need deterministic sampling. The input should be conditioned to remain within the selected range and protected against transients; the integrated circuit provides overvoltage protection to ±20 V but does not replace a correctly engineered external protection network.
What is the best drop-in replacement for ADS8681IPW?
ADS8681IPWR is the closest ordering alternative because it provides the same ADS8681 electrical function in the same 16-TSSOP footprint and differs chiefly in reel packaging. Within the ADS868x family, ADS8685IPW and ADS8689IPW share the family architecture, but their programmable input ranges must be checked before substitution. A mechanical footprint match alone is not sufficient because range selection, digital interface behavior, and application requirements must also agree.
Can ADS8689IPW replace ADS8681IPW?
ADS8689IPW can serve as a same-family drop-in candidate only when its programmable input ranges satisfy the original design. Both parts are members of the TI ADS868x 16-bit, 1-MSPS SAR data-acquisition family, but ADS8689 uses a different input-range configuration than ADS8681. Review the range-selection pins or software configuration in the manufacturer documentation and confirm the 16-TSSOP land pattern before approving the replacement.
What is the best Analog Devices equivalent for ADS8681IPW?
The AD7689 is commonly listed as a functionally similar 16-bit SAR data-converter alternative, but it is not automatically a drop-in replacement for ADS8681IPW. The physical package, pin arrangement, supply requirements, interface timing, and input-range implementation must be compared before substitution. For a true no-board-change replacement, use only a part with the same 16-TSSOP land pattern and confirm every control and conversion signal in the datasheet.
Does ADS8681IPW need an external reference voltage?
No external reference is required for normal operation because ADS8681 contains an on-chip 4.096 V reference. Texas Instruments describes the reference as having extremely low temperature drift, making it useful for standalone acquisition systems that otherwise need a separate precision reference and its associated bypass network. If the design requires a different reference or externally monitored calibration, use the appropriate device variant and follow the manufacturer’s reference-pin configuration.
How should the ADS8681IPW input filter and layout be designed?
Place the analog input filter and any protection components close to the ADS8681IPW to minimize parasitic pickup between the sensor or conditioning stage and the converter. Use the recommended supply and reference bypassing from the manufacturer’s application circuit. TI support material identifies a 15 kHz input-filter bandwidth, so bandwidth, conversion time, and settling must be evaluated together. Keep digital clock and interface routing away from the analog input node to reduce conversion noise.
How do I get a current quote and lead time for ADS8681IPW?
Use the Request a Quote form on this page to request the current unit availability, production lead time, and order confirmation for ADS8681IPW. The device is a catalog TI part with an official product page and manufacturer datasheet, but pricing, stock, and lead time can change with demand and packaging configuration. Specify whether tube or reel packing is required and provide the target quantity so the sourcing response matches the intended assembly process.

エンジニアリング参考データ: ADS8681IPW — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose ADS8681IPW for 16-bit, single-channel measurements requiring a 1 MSPS SAR converter, a 5 V supply, and a programmable bipolar input range of ±12 V, ±10 V, ±6 V, ±5 V, or ±2.5 V. It is particularly useful when the signal can exceed the supply voltage but remains within the integrated ±20 V overvoltage-protection capability. ADS8685IPW or ADS8689IPW may be preferable when their respective input-range sets better match the acquisition plan while retaining the ADS868x family architecture. ADS8681IPWR is the functional equivalent for tape-and-reel assembly rather than tube-fed production. For higher-rate, multichannel, or different-interface requirements, perform a fresh converter and footprint review rather than assuming a family member is interchangeable.

代替品との比較

パラメータ この製品 ADS8685IPW ADS8689IPW ADS8681IPWR
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package 16-TSSOP 16-TSSOP 16-TSSOP 16-TSSOP
Resolution 16 bit 16 bit 16 bit 16 bit
Maximum Sampling Rate 1 MSPS 1 MSPS 1 MSPS 1 MSPS
Number of Input Channels 1 channel 1 channel 1 channel 1 channel
Analog Supply 5 V 5 V 5 V 5 V
Internal Reference 4.096 V 4.096 V 4.096 V 4.096 V
Orderable Packing Tube Tube Tube Tape and reel

主な差別化要因

  • Broad programmable bipolar input selection (vs ADS8685IPW)
  • Integrated precision conversion baseline (vs ADS8689IPW)
  • Exact electrical equivalent with assembly flexibility (vs ADS8681IPWR)

設計ノート

Place the input protection, range-selection, and filtering components close to the ADS8681IPW analog input and reference pins. Keep the sensitive input trace short, avoid routing it beneath digital clock or serial-data paths, and provide an uninterrupted ground plane. Follow the reference and decoupling network shown in the manufacturer’s application circuit. The 4.096 V internal reference simplifies the BOM, but its bypass and routing still require careful implementation to avoid introducing acquisition noise.

Account for acquisition time and input settling before interpreting the 1 MSPS figure as usable signal bandwidth. TI support material identifies a 15 kHz input-filter bandwidth for ADS8681, so use an explicit low-pass network when aliasing must be controlled. Establish the cutoff from the source impedance, permitted transition area, and required attenuation rather than treating 1 MSPS as the input bandwidth. Validate settling and noise with the selected range and the actual converter timing.

Use a clean 5 V analog supply and place the recommended bypass capacitors directly between the supply and ground pins. Decouple noisy digital or switching supplies before they reach the ADC, and route return current away from the sensitive input reference. The integrated overvoltage protection to ±20 V is not a substitute for a correctly selected external surge or ESD network. Verify that external protection leakage and capacitance do not degrade input accuracy or acquisition settling.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

Compliance status requires confirmation from the manufacturer’s current product documentation. No standardized compliance designation should be inferred solely from the surface-mount package.

データ検証日: 2026-11-18 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

ADS8681IPW datasheet ADS8681IPW pinout ADS8681IPW datasheet pdf ADS8681IPW equivalent ADS8681IPW replacement ADS8681IPW price ADS8681IPW stock Texas Instruments ADS8681IPW ADS8681 vs ADS8685 ADS8681 16-TSSOP footprint ADS8681 programmable input ranges ADS8681 industrial process measurement

関連部品&用語

Texas Instruments ADS8681IPW ADS8681 ADS8685IPW ADS8689IPW ADS8681IPWR AD7689 Successive-approximation register SAR ADC Analog-to-digital converter Data converter Data-acquisition IC Analog front end Integrated input driver On-chip voltage reference 4.096 V reference Programmable bipolar input range 16-TSSOP package TSSOP package family Surface-mount technology 1 MSPS 16-bit resolution Industrial process control PLC analog input Factory automation Overvoltage protection Input filtering Analog signal conditioning
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示