AT90CAN32-15AT1 - 15MHz 32KB AVR CAN MCU | Microchip
部品番号: AT90CAN32-15AT1 ✓ 生産中AT90CAN32-15AT1 概要
A microcontroller is a programmable semiconductor that integrates a CPU core, memory, I/O ports, timers, and communication peripherals on one device. The AT90CAN32 belongs to the AVR 8-bit microcontroller family, a branch of embedded processors used in industrial control, automotive electronics, instrumentation, and CAN-connected equipment. Its enhanced RISC architecture supports efficient instruction execution while retaining a relatively simple programming model.
The AT90CAN32-15AT1 operates at 15 MHz and includes 32 KB of ISP flash, 1 KB of EEPROM, and 2 KB of SRAM. The manufacturer describes the AT90CAN32 family as providing 53 general-purpose I/O lines, 32 working registers, and a CAN controller. Its TQFP-64 package exposes the complete mixed-signal and communication interface set while supporting conventional surface-mount PCB assembly.
The integrated CAN controller is the principal technical distinction from a general-purpose 8-bit AVR. It allows the controller to participate in standardized vehicle or industrial networks without requiring a separate CAN transceiver. Designers still need an external transceiver for physical-layer signaling, but the MCU handles frame handling, filtering, interrupts, and higher-level CAN operation. ISP flash supports in-system programming, while EEPROM preserves calibration, configuration, or serial-number data across power cycles.
Typical uses include CAN-based industrial controllers, vehicle body and dashboard modules, diagnostic equipment, sensor gateways, motor-control subsystems, and low-power embedded instruments. The 15 MHz operating point provides useful computation margin for protocol handling and control tasks, while the 53 I/O lines allow multiple sensors, actuators, status indicators, and communications peripherals to share one controller.
PCB design should preserve the decoupling requirements, clock stability, programming access, and CAN signal routing described in the manufacturer datasheet. Place input and output capacitors close to the device, route the clock network away from noisy switching nodes, and provide a clean transceiver interface for the CAN TX and RX signals. The TQFP footprint also needs adequate solder-mask and thermal-via planning for reliable manufacturing.
This product page combines the manufacturer family information with package, memory, speed, and replacement context. It also organizes practical guidance for CAN termination, firmware migration, decoupling, and PCB layout so engineers can evaluate the AT90CAN32-15AT1 before integrating it into a new embedded design.
ドロップイン代替品: AT90CAN32-15AT1 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: AT90CAN32-15AT1 (同一形状・フットプリント) — 相違点: Package, Product Type, General-Purpose I/O Lines, General-Purpose Working Registers, CAN Controller.
AT90CAN32-15AZ
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AT90CAN32-15AU
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
AT90CAN32-16MU
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AT90CAN32-16AU
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AT90CAN32-15AT
✅ ドロップイン価格はお問い合わせください
データシートを見る →AT90CAN32-15AT1 最大定格&電気的特性
| Microcontroller Type | 8-bit RISC MCU |
| CPU Family | AVR |
| 最大クロック周波数 | 15 MHz |
| Flash Memory | 32 KB |
| EEPROM | 1 KB |
| SRAM | 2 KB |
| General-Purpose I/O Lines | 53 lines |
| General-Purpose Working Registers | 32 registers |
| Controller Interface | CAN |
| パッケージ | 64-TQFP |
| Package Dimensions | 14 mm x 14 mm |
| Temperature Grade | Industrial |
| Programming Interface | In-system programming (ISP) |
| 実装タイプ | Surface mount |
AT90CAN32-15AT1 14 mm x 14 mm ピン配置ガイド
AT90CAN32-15AT1 (14 mm x 14 mm パッケージ) のピン配置。 このデジタルICには、GPIO、通信インターフェース (UART、SPI、I2C)、および電源ピンが含まれています。代替ピン機能と設定オプションについては、メーカーのデータシートを参照してください。組み込みシステム設計とPCBレイアウトに不可欠です。
詳細なピン配置データはありません: AT90CAN32-15AT1.
詳細は データシート をご参照ください。
主な用途
AT90CAN32-15AT1 の用途: 6 件s: Industrial CAN Sensor Gateway, Automotive Body Control Module, CAN Diagnostic Instrument, Industrial Motor Control Interface, Networked Environmental Monitor, Embedded CAN Test Fixture.
Industrial CAN Sensor Gateway
The AT90CAN32-15AT1 fits an industrial sensor gateway because its integrated CAN controller, 53 general-purpose I/O lines, and 15 MHz AVR core provide enough interface capacity for multiple sensors and remote node management. It can collect digital and analog-channel information, filter CAN traffic, update local status indicators, and maintain protocol state while an external transceiver connects the MCU to the physical bus. The 2 KB SRAM supports temporary frame and application data, while 1 KB of EEPROM preserves configuration or calibration values. The key design consideration is separating CAN and switching-power paths from precision sensing and clock circuitry.
おすすめ
Automotive Body Control Module
The AT90CAN32-15AT1 is suitable for distributed vehicle body-control tasks that combine CAN communication with switch, lamp, sensor, and actuator supervision. Its CAN controller handles network frames and interrupts, allowing the 15 MHz AVR core to execute control logic without a separate communications processor. The 53 I/O lines offer substantial digital connectivity, and EEPROM can store configuration or diagnostic information across power cycles. Because the AT1 ordering code denotes an industrial-grade device, engineers must confirm environmental and automotive qualification requirements before production release and must use an external CAN transceiver with appropriate bus protection.
おすすめ
CAN Diagnostic Instrument
The AT90CAN32-15AT1 can form the core of a compact CAN diagnostic instrument because it combines an 8-bit controller, integrated CAN handling, serial programming support, and enough I/O for buttons, displays, and status signaling. Firmware can decode or filter incoming frames, execute service requests, and present results through UART or another serial peripheral. Its 15 MHz clock provides useful timing margin for basic protocol analysis and logging. A practical design should add a galvanic or protected transceiver interface, careful ground planning, and a watch-dog strategy so a bus or communications fault cannot leave the instrument in an unsafe state.
おすすめ
Industrial Motor Control Interface
The AT90CAN32-15AT1 is appropriate for a CAN-connected motor-control interface where the MCU coordinates commands, reports machine state, and handles interlocks outside the power-conversion stage. Its timers and 53 I/O lines can support limit switches, encoders, contactor feedback, and status outputs, while the integrated CAN controller links the module to a wider automation system. The 15 MHz AVR core can execute deterministic supervisory logic, but motor switching devices should remain on dedicated power circuitry. Keep high-current transients and motor-node return currents away from the MCU, analog references, oscillator network, and CAN transceiver ground path.
おすすめ
Networked Environmental Monitor
The AT90CAN32-15AT1 works well in a networked environmental monitor that periodically samples sensors, applies filtering or thresholds, and publishes measurements over CAN. Its 53 I/O lines can accommodate digital sensors, alarm outputs, and local indicators, while EEPROM can retain calibration constants or installation identifiers. The integrated CAN controller reduces host-side protocol overhead compared with a general-purpose MCU without CAN support. For low-noise measurement accuracy, use dedicated analog and reference layout practices, provide stable filtering near sensor inputs, and isolate the MCU and CAN transceiver from pumps, heaters, relay contacts, or other switching loads that can corrupt measurements.
おすすめ
Embedded CAN Test Fixture
The AT90CAN32-15AT1 can be used in a compact production or service test fixture for exercising CAN nodes, simulating bus traffic, and coordinating pass/fail results. The 32 KB flash region provides room for application firmware and in-system programming workflows, while the 2 KB SRAM can hold temporary frames and test state. Its 53 I/O lines support stimulus outputs, measured-input capture, fixture interlocks, and operator interfaces. For repeatable testing, isolate the fixture from ground potential differences, include controlled termination only where required by the bus topology, and validate watchdog recovery when communication or external stimulus conditions fail.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AT90CAN32-15AT1 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AT90CAN32-15AZ | AT90CAN32-15AU | AT90CAN32-16MU | AT90CAN32-16AU | AT90CAN32-15AT |
|---|---|---|---|---|---|---|
| Package | 64-TQFP | 64-TQFP | 64-TQFP | 64-TQFP | 64-TQFP | 64-TQFP |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Maximum Clock Frequency | 15 MHz | 15 MHz | 15 MHz | 16 MHz | 16 MHz | 15 MHz |
| Flash Memory | 32 KB | 32 KB | 32 KB | 32 KB | 32 KB | 32 KB |
| EEPROM | 1 KB | 1 KB | 1 KB | 1 KB | 1 KB | 1 KB |
| SRAM | 2 KB | 2 KB | 2 KB | 2 KB | 2 KB | 2 KB |
| General-Purpose I/O Lines | 53 lines | 53 lines | 53 lines | 53 lines | 53 lines | 53 lines |
| CAN Controller | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Programming Interface | ISP | ISP | ISP | ISP | ISP | ISP |
主な差別化要因
- Direct 15 MHz match for timing-qualified designs (vs AT90CAN32-16MU)
- Exact 32 KB flash and 64-TQFP configuration (vs AT90CAN32-15AZ)
- Integrated CAN controller with 53 I/O lines (vs AT90CAN32-16AU)
- Established 15 MHz family ordering option (vs AT90CAN32-15AT)
設計ノート
Place the decoupling capacitors for each supply rail as close as practical to the associated AT90CAN32-15AT1 pins, with a short ground return to minimize loop area. Route the oscillator and reset-related traces away from CAN, switching-regulator, relay, and motor-drive nodes. The 64-TQFP footprint requires correct land-pattern dimensions and solder-mask design; verify them against the manufacturer package drawing before releasing artwork.
Keep the MCU CAN TX and RX pins connected to a suitable external transceiver rather than to the physical bus directly. Provide a continuous return path beneath the interface, keep the transceiver and protection components near the connector, and separate slow digital logic from sensitive analog inputs. Verify that the selected transceiver, bus baud rate, termination strategy, common-mode range, and isolation requirements are appropriate for the installation environment.
Do not substitute an AT90CAN32 ordering suffix based only on the clock frequency. Confirm the 64-TQFP footprint, flash density, SRAM and EEPROM capacity, temperature grade, qualification status, pin multiplexing, and supply limits against the manufacturer datasheet. When moving from 15 MHz to a 16 MHz member, retest baud-rate tolerances, timer periods, PWM outputs, communication timeouts, and firmware delays that were calibrated to the original clock.
Design the regulator and decoupling network around the MCU's supply-current behavior over clock activity, peripheral load, and CAN interrupt service rather than using an idle-state estimate. Provide local bulk energy close to the device and maintain a quiet return network between the MCU, analog sections, and CAN transceiver. If motors, solenoids, or relays share the board, use separate return paths and filtering to prevent transient current from disturbing communication or timing.
コンプライアンス情報
The AT90CAN32-15AT1 is identified as an industrial-grade 64-TQFP MCU, but specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the exact manufacturer product and quality documentation.