INA2128UA - Dual Precision Instrumentation Amplifier | Texas Instruments
部品番号: INA2128UA ✓ 生産中INA2128UA 概要
An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals superimposed on larger common-mode voltages. Its internal three-op-amp architecture provides matched input stages, high differential input impedance, accurate gain control, and strong common-mode rejection. This makes the INA2128 suitable for sensor interfaces where a low-level differential signal must be amplified accurately in the presence of substantial DC voltage, industrial noise, or ground-potential differences.
The INA2128 combines low offset and drift with a minimum 120 dB CMRR. Input overload protection extends to plus or minus 40 V, helping the amplifier tolerate accidental large input transients. Its supply range of 2.25 V to 18 V supports single-supply and dual-supply instrumentation systems. A single external resistor selects the gain, reducing the number of precision components needed for adjustable measurement channels.
The versatile three-op-amp design uses current-feedback input circuitry to preserve bandwidth at higher gains. According to the Texas Instruments datasheet, bandwidth remains 200 kHz at a gain of 100. This combination of precision DC behavior and usable high-gain bandwidth makes the device suitable for bridge sensors, current measurement, biomedical instrumentation, and industrial data-acquisition systems.
Typical uses include low-voltage pressure and strain-signal conditioning, thermocouple and RTD amplification, current-shunt measurement, battery-cell monitoring, and precision analog-front-end designs. The two-channel configuration is especially useful when a system must process two related sensor inputs while maintaining consistent gain-setting and supply architecture across both channels.
Choose gain resistors with suitable tolerance and temperature coefficient, and verify common-mode headroom at the lowest supply voltage. Input and reference pins require careful layout because leakage, parasitic resistance, and asymmetric copper can degrade CMRR. The gain-setting resistor should be placed close to the device, with symmetrical input routing where practical.
This product overview combines manufacturer specifications, package details, application guidance, and drop-in replacement information to support faster component selection and PCB planning. It also identifies the trade-offs involved when changing amplifier families, including gain range, bandwidth, offset performance, supply voltage, and protection requirements.
ドロップイン代替品: INA2128UA — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA2128UA (同一形状・フットプリント) — 相違点: Package.
INA2128U
✅ ドロップイン価格はお問い合わせください
データシートを見る →INA2128UA-1
✅ ドロップイン📋 参考代替品(カタログ未掲載)
INA2128UA 最大定格&電気的特性
| Amplifier Type | Dual instrumentation amplifier |
| Number of Channels | 2 channels |
| Gain Range | 1 to 10,000 |
| Gain Setting Method | 1 external resistor |
| Bandwidth at Gain 100 | 200 kHz |
| Maximum Offset Voltage | 50 uV |
| Maximum Offset Drift | 0.5 uV/degree C |
| Maximum Input Bias Current | 5 nA |
| Minimum Common-Mode Rejection | 120 dB |
| Input Overload Protection | plus or minus 40 V |
| Supply Voltage Range | 2.25 V to 18 V |
| Internal Architecture | 3-op-amp design |
| Input Circuitry | Current-feedback |
| パッケージ | 16-pin SOIC (DW) |
| 実装タイプ | Surface mount |
INA2128UA 16-pin soic (dw) ピン配置ガイド
INA2128UA (16-pin soic (dw) パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: INA2128UA.
詳細は データシート をご参照ください。
主な用途
INA2128UA の用途: 6 件s: Strain-Gauge Bridge Measurement, Current-Shunt Monitoring, Battery-Cell Voltage Acquisition, Precision Pressure Sensor Interface, Biomedical Sensor Signal Conditioning, Industrial Data Acquisition.
Strain-Gauge Bridge Measurement
The INA2128UA fits strain-gauge and resistive bridge front ends that produce small differential signals on a substantial common-mode voltage. Its two independently adjustable channels can process complementary bridge outputs or two related sensing elements, while the 1 to 10,000 gain range accommodates both millivolt-level and low-level volt signals. Maximum offset voltage of 50 uV and maximum drift of 0.5 uV/degree C help stabilize measurements over temperature, and 120 dB minimum CMRR suppresses common-mode excitation and coupled industrial noise. Gain is established with one resistor, allowing the design to use matched high-precision resistors while retaining a straightforward calibration structure.
おすすめ
Current-Shunt Monitoring
The INA2128UA is appropriate for bidirectional or unidirectional current measurement using a low-ohm shunt in the high-current path. Its maximum input bias current of 5 nA limits the error introduced into high-impedance sensing nodes, while plus or minus 40 V input protection improves tolerance of transient voltage during fault conditions. Two channels allow simultaneous measurement of two shunt sections or power-rail currents, and gains up to 10,000 provide useful amplification for low-value shunts. The 200 kHz bandwidth at gain 100 permits measurement of current waveforms beyond static DC without requiring a higher-speed alternative.
おすすめ
Battery-Cell Voltage Acquisition
The dual-channel INA2128UA can monitor adjacent battery cells or divided high-voltage bus sections in a battery-management system. Its 2.25 V to 18 V supply range supports low-voltage sensing rails, and the 120 dB minimum common-mode rejection helps isolate small voltage differences from the much larger potential shared by series-connected cells. Maximum offset of 50 uV and drift of 0.5 uV/degree C are particularly valuable when accurate cell balancing depends on measuring small voltage differences. The two-channel architecture reduces the number of separate amplifiers needed for redundant or differential cell measurements.
おすすめ
Precision Pressure Sensor Interface
The INA2128UA supports pressure and force sensors that generate a differential millivolt output on a common-mode baseline. The 5 nA maximum input bias current minimizes loading of high-impedance sensor outputs, and the 50 uV maximum offset reduces errors in pressure readings that depend on detecting small differential signals. Adjustable gains from 1 to 10,000 allow the same amplifier family to serve different sensor sensitivities. With 200 kHz bandwidth at gain 100, the device can also handle dynamic pressure events while retaining low DC error for static measurements.
おすすめ
Biomedical Sensor Signal Conditioning
The INA2128UA can condition low-amplitude differential signals from biomedical and diagnostic sensors where offset, drift, and common-mode rejection determine measurement quality. Its 50 uV maximum offset and 0.5 uV/degree C maximum drift limit temperature-dependent baseline errors, while 120 dB minimum CMRR helps reject mains-coupled interference and body-coupled common-mode voltage. The dual-channel configuration supports two sensors or a differential and reference channel. Plus or minus 40 V input protection is useful for robust connector interfaces, provided signal amplitude and duration remain within the device's absolute-maximum ratings.
おすすめ
Industrial Data Acquisition
The INA2128UA is well suited to industrial data-acquisition modules that combine slow precision measurements with occasional higher-bandwidth signals. Two channels support redundant sensors, bridge measurements, or gain stages feeding multiplexed converters, while the 120 dB minimum CMRR reduces errors from long cables and grounded machinery. The 200 kHz bandwidth at gain 100 provides useful signal bandwidth, and gain selection through one external resistor simplifies calibration across multiple board variants. Plus or minus 40 V input protection improves robustness at connector-exposed inputs, although protection-network design must preserve accuracy and bandwidth.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA2128UA — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA2128U | INA2128UA-1 |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | SOIC-16 (DW) | SOIC-16 (DW) | SOIC-16 (DW) |
| Channel Count | 2 channels | 2 channels | 2 channels |
| Gain Range | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 |
| Bandwidth at Gain 100 | 200 kHz | 200 kHz | 200 kHz |
| Supply Voltage Range | 2.25 V to 18 V | 2.25 V to 18 V | 2.25 V to 18 V |
| Input Protection | plus or minus 40 V | plus or minus 40 V | plus or minus 40 V |
主な差別化要因
- High accuracy for low-level differential measurements (vs INA2128U)
- Dual-channel instrumentation amplification (vs INA2128U)
- Strong common-mode rejection (vs INA2128UA-1)
設計ノート
Keep the gain-setting resistor close to the INA2128UA gain pin, and route each input channel symmetrically. Use a common ground reference for both amplifier channels and avoid placing long, high-impedance input traces next to switching nodes. Refer to the manufacturer datasheet pin-description and application diagrams when assigning the 16-pin SOIC connections.
Do not assume the input-protection rating changes the normal operating range. The plus or minus 40 V protection rating describes tolerance of input voltage, while valid measurement operation still requires compliance with the specified common-mode and absolute-maximum limits. Also verify output swing at the selected supply voltage before choosing a gain that could saturate the amplifier.
For maximum CMRR, use equal input impedance and matched resistor networks on both sides of each differential input. Keep leakage from PCB contamination and flux residue under control because the 5 nA maximum input bias current makes high-impedance nodes sensitive to contamination. A protective resistor can limit transient current, but its value should preserve bandwidth and input impedance at the intended gain.
Place input and reference components adjacent to their corresponding pins, with the shortest practical return path to the exposed supply and ground structure. The SOIC-16 package benefits from stable ground-plane continuity beneath the device. Avoid adding test-point loops that increase parasitic capacitance on high-gain input nodes, particularly when 200 kHz bandwidth at gain 100 is a system requirement.
コンプライアンス情報
Compliance claims require confirmation for the exact INA2128UA ordering code and package. The manufacturer product and datasheet links should be reviewed during production qualification.