INA115BUG4 - 1MHz Precision Instrumentation Amplifier | TI
部品番号: INA115BUG4 ✓ 生産中INA115BUG4 概要
An instrumentation amplifier is a specialized amplifier that measures the voltage difference between two inputs while rejecting common-mode signals. Its typical signal-chain hierarchy is instrumentation amplifier → differential amplifier → analog amplifier → analog signal-chain IC. By combining high input impedance, precise gain control, and differential input handling, this device reduces the need for separate input amplifiers in sensor-conditioning systems.
Key features include the manufacturer-rated 1 MHz bandwidth, 50 µV input offset voltage, and 11 nV/√Hz noise density. The three-op-amp architecture provides gain adjustment flexibility, while the INA115 additionally exposes connections to the input amplifiers, identified as A1 and A2. Those connections support improved gain accuracy at high gain settings and can assist in implementing switched-gain arrangements.
The INA115BUG4 supports single-supply operation from 2.25 V to 18 V according to the INA115BU comparison data. Its instrumentation-amplifier architecture is intended for low-level differential signals, but bandwidth and input-voltage limits must be checked at each selected gain. Because this is an analog precision device, careful grounding, reference configuration, resistor selection, and protection design are essential for repeatable results.
Typical applications include bridge-based pressure and load-cell measurements, low-voltage sensor front ends, isolated current sensing, biomedical instrumentation, and industrial process monitoring. The 16-pin SOIC package is also practical for conventional surface-mount assembly, although sensitive input routing must be kept away from switching nodes and high-current paths.
For a new design, verify the gain-setting resistor values, allowable input common-mode range, supply voltage, output swing, and input protection limits against the manufacturer datasheet for the intended operating condition. Use a clean analog ground reference and place input and gain-setting components close to the device to minimize parasitic errors.
This product summary combines the manufacturer’s device description with practical guidance for INA115 pinout verification, gain selection, sensor conditioning, low-noise layout, package compatibility, and drop-in replacement assessment.
ドロップイン代替品: INA115BUG4 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA115BUG4 (同一形状・フットプリント) — 相違点: Input Noise Density, Number of Amplifiers, Package, Slew Rate.
INA115BU
✅ ドロップイン価格はお問い合わせください
データシートを見る →INA115BUG4 最大定格&電気的特性
| Product Type | Precision instrumentation amplifier |
| Number of Amplifiers | 3 amplifiers |
| Gain-Bandwidth Product | 1 MHz |
| Input Offset Voltage | 50 µV |
| Input Noise Density | 11 nV/√Hz |
| Power Consumption | 3 mA |
| Supply Voltage Range | 2.25 V to 18 V |
| Slew Rate | 0.6 V/µs |
| Maximum Supply Voltage | 50 V |
| 出力タイプ | Single-ended |
| Internal Amplifier Connections | A1 and A2 connections |
| Architecture | Three-op-amp instrumentation amplifier |
| パッケージ | 16-SOIC, 0.295 inch (7.50 mm) body width |
| 実装タイプ | Surface mount |
INA115BUG4 16-soic, 0.295 inch (7.50 mm) body width ピン配置ガイド
INA115BUG4 (16-soic, 0.295 inch (7.50 mm) body width パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: INA115BUG4.
詳細は データシート をご参照ください。
主な用途
INA115BUG4 の用途: 6 件s: Bridge Sensor Signal Conditioning, Low-Level Pressure Sensing, Load Cell and Weighing Systems, Industrial Current Sensing, Biomedical Signal Acquisition, Process and Environmental Monitoring.
Bridge Sensor Signal Conditioning
The INA115BUG4 is appropriate for differential bridge outputs because its instrumentation-amplifier architecture measures small voltage differences while rejecting common-mode voltage. The Texas Instruments product page identifies a 50 µV input offset voltage, 11 nV/√Hz input noise density, and 1 MHz gain-bandwidth product. Place the amplifier and gain-setting resistor near the bridge sensor, keep excitation wiring away from digital circuits, and use the amplifier’s external reference to establish the output midpoint when the system is single-supply. The achievable gain and output swing must remain within the datasheet limits.
おすすめ
Low-Level Pressure Sensing
The INA115BUG4 can condition millivolt-level pressure-sensor outputs when low offset and low noise are more important than wide bandwidth. Its 50 µV input offset voltage and 11 nV/√Hz noise density provide the core performance needed to preserve small differential signals, while the 1 MHz gain-bandwidth product supports practical sensor bandwidth. Use short, guarded input traces and verify the selected external gain resistor against the INA115 datasheet. The output reference should be configured carefully in single-supply systems to preserve bidirectional measurement range.
おすすめ
Load Cell and Weighing Systems
A load cell produces a small differential voltage proportional to applied force, making the INA115BUG4 suitable for precision weighing and force measurement. Its three-op-amp instrumentation topology supports accurate differential amplification, and the 50 µV offset specification helps control errors near the signal floor. Connect the load-cell excitation and return in a symmetrical layout, keep the input loop small, and use a dedicated analog ground region to prevent motor or heater currents from entering the measurement path. Gain and common-mode limits must be checked for the full load-cell range.
おすすめ
Industrial Current Sensing
The INA115BUG4 can amplify the differential voltage generated by a current-shunt or current-sense element in industrial monitoring equipment. Its 11 nV/√Hz input noise density and 50 µV offset voltage are useful when the measured current produces a relatively small differential voltage. Route the shunt connections as a tight differential pair, use a Kelvin-style connection where possible, and keep the shunt’s high-current path separate from the amplifier’s reference and ground circuitry. Confirm that the shunt voltage remains inside the amplifier’s common-mode range.
おすすめ
Biomedical Signal Acquisition
The INA115BUG4 is suitable for low-amplitude biomedical front ends where offset and input noise can affect measurement quality. Its 11 nV/√Hz noise density, 50 µV offset voltage, and differential input structure support conditioning of small sensor-derived signals, while the 1 MHz bandwidth exceeds many physiological-signal requirements. Protection, isolation, leakage, and patient-safety requirements must be evaluated separately; the amplifier itself is not automatically a complete medical front end. Follow the manufacturer application guidance and validate the complete patient-connected circuit for safety.
おすすめ
Process and Environmental Monitoring
The INA115BUG4 fits process-control front ends that measure small differential signals from thermocouple amplifiers, strain gauges, or resistive sensors. The instrumentation-amplifier architecture provides differential input handling and gain adjustment in a compact 16-SOIC package. Its 1 MHz bandwidth supports moderate-bandwidth sensing, while the 50 µV offset and 11 nV/√Hz noise density help retain low-level measurement information. Use dedicated analog grounding, isolate the input route from relay and switching circuits, and verify the output range against the controller’s input limits.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA115BUG4 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA115BU |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 16-SOIC (0.295", 7.50 mm width) | 16-SOIC |
| Product Type | Precision instrumentation amplifier | Instrumentation amplifier |
| Gain-Bandwidth Product | 1 MHz | 1 MHz |
| Supply Voltage Range | 2.25 V to 18 V | 2.25 V to 18 V |
| Slew Rate | 0.6 V/µs | 0.6 V/µs |
| Maximum Supply Voltage | 50 V | 50 V |
| Amplifier Count | 3 amplifiers | 1 amplifier |
主な差別化要因
- Wide bandwidth within a general-purpose precision instrumentation amplifier (vs INA115BU)
- Low 11 nV/√Hz input noise density (vs INA115BU)
- Low 50 µV input offset voltage (vs INA115BU)
- Low 3 mA operating power (vs INA115BU)
設計ノート
Place the INA115BUG4, gain-setting resistors, and optional input filters close together to minimize parasitic resistance and capacitance on the high-impedance input nodes. Route the differential inputs as a compact pair, avoid routing them beneath switching regulators or digital return paths, and use the A1 and A2 connections exactly as shown in the manufacturer datasheet for accurate high-gain operation.
The 11 nV/√Hz noise density is meaningful only when the complete input network has acceptable thermal noise and the gain is selected for the required signal bandwidth. Verify the external gain resistor and compensation values from the Texas Instruments datasheet, avoid excessive bandwidth when a narrow-band sensor is used, and confirm that input capacitance, common-mode range, and output swing support the intended operating point.
Do not assume that a shared 16-SOIC outline guarantees drop-in compatibility. INA115BU is the closest documented family candidate, but production substitutions must also match pin functions, gain-setting architecture, reference behavior, temperature grade, and ordering details. Review the manufacturer pin-description table and ordering information before approving a replacement for INA115BUG4.
The INA115BUG4 consumes approximately 3 mA under the manufacturer-described operating condition. Supply decoupling should be placed close to the power and ground pins, while analog measurement returns should remain separate from noisy power currents. Validate the reference source for noise and stability because reference variation can directly affect output accuracy independently of the amplifier’s input noise.
コンプライアンス情報
The INA115 family comparison information discusses RoHS and REACH, but no explicit compliance declaration for the INA115BUG4 ordering code was available. AEC-Q100 is not applicable to this general-purpose precision analog device.