Texas Instruments

INA115BUG4 - 1MHz Precision Instrumentation Amplifier | TI

MPN: INA115BUG4 ✓ 啟用中
50 µV Vdss 16-SOIC, 0.295 inch (7.50 mm) body width Package
MOQ: 1 |

INA115BUG4 概覽

The Texas Instruments INA115BUG4 is a precision instrumentation amplifier with a 1 MHz gain-bandwidth product, 50 µV input offset voltage, 11 nV/√Hz input noise, and 3 mA power consumption, supplied in a 16-pin SOIC package. It is designed for applications requiring accurate differential measurement from low-level sensors and bridge circuits.

An instrumentation amplifier is a specialized amplifier that measures the voltage difference between two inputs while rejecting common-mode signals. Its typical signal-chain hierarchy is instrumentation amplifier → differential amplifier → analog amplifier → analog signal-chain IC. By combining high input impedance, precise gain control, and differential input handling, this device reduces the need for separate input amplifiers in sensor-conditioning systems.

Key features include the manufacturer-rated 1 MHz bandwidth, 50 µV input offset voltage, and 11 nV/√Hz noise density. The three-op-amp architecture provides gain adjustment flexibility, while the INA115 additionally exposes connections to the input amplifiers, identified as A1 and A2. Those connections support improved gain accuracy at high gain settings and can assist in implementing switched-gain arrangements.

The INA115BUG4 supports single-supply operation from 2.25 V to 18 V according to the INA115BU comparison data. Its instrumentation-amplifier architecture is intended for low-level differential signals, but bandwidth and input-voltage limits must be checked at each selected gain. Because this is an analog precision device, careful grounding, reference configuration, resistor selection, and protection design are essential for repeatable results.

Typical applications include bridge-based pressure and load-cell measurements, low-voltage sensor front ends, isolated current sensing, biomedical instrumentation, and industrial process monitoring. The 16-pin SOIC package is also practical for conventional surface-mount assembly, although sensitive input routing must be kept away from switching nodes and high-current paths.

For a new design, verify the gain-setting resistor values, allowable input common-mode range, supply voltage, output swing, and input protection limits against the manufacturer datasheet for the intended operating condition. Use a clean analog ground reference and place input and gain-setting components close to the device to minimize parasitic errors.

This product summary combines the manufacturer’s device description with practical guidance for INA115 pinout verification, gain selection, sensor conditioning, low-noise layout, package compatibility, and drop-in replacement assessment.

直接替換替代品,適用於 INA115BUG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

此系列的變體

與下列產品可直接替換的同系列型號: INA115BUG4 (相同外形與佔位) — 差異在於 Input Noise Density, Number of Amplifiers, Package, Slew Rate.

Texas Instruments
Input Noise Density: 11 nV/sqrt(Hz)
Number of Amplifiers: 1 circuit
Package: 16-pin SOIC
比較對象 INA115BUG4 →

INA115BU

✅ 直接替換
Texas Instruments
📦 16-SOIC (0.295", 7.50 mm width)
Precision instrumentation amplifier · Three-op-amp instrumentation amplifier · 1 MHz · 50 uV · 0.25 uV/degree C maximum · 11 nV/sqrt(Hz) · 2 nA · 115 dB

聯絡詢價

查看資料表 →

INA115BUG4 最大額定值與電氣特性

Product Type Precision instrumentation amplifier
Number of Amplifiers 3 amplifiers
Gain-Bandwidth Product 1 MHz
Input Offset Voltage 50 µV
Input Noise Density 11 nV/√Hz
Power Consumption 3 mA
Supply Voltage Range 2.25 V to 18 V
Slew Rate 0.6 V/µs
Maximum Supply Voltage 50 V
輸出類型 Single-ended
Internal Amplifier Connections A1 and A2 connections
Architecture Three-op-amp instrumentation amplifier
封裝 16-SOIC, 0.295 inch (7.50 mm) body width
安裝類型 Surface mount

INA115BUG4 16-soic, 0.295 inch (7.50 mm) body width 腳位配置指南

INA115BUG4(16-soic, 0.295 inch (7.50 mm) body width 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。

INA115BUG4 的 16-soic, 0.295 inch (7.50 mm) body width 封裝腳位圖

無詳細腳位定義資料: INA115BUG4.

請參閱 資料表 以查看完整腳位配置。

典型應用

INA115BUG4 適用於 6 應用s: Bridge Sensor Signal Conditioning, Low-Level Pressure Sensing, Load Cell and Weighing Systems, Industrial Current Sensing, Biomedical Signal Acquisition, Process and Environmental Monitoring.

🏭

Bridge Sensor Signal Conditioning

The INA115BUG4 is appropriate for differential bridge outputs because its instrumentation-amplifier architecture measures small voltage differences while rejecting common-mode voltage. The Texas Instruments product page identifies a 50 µV input offset voltage, 11 nV/√Hz input noise density, and 1 MHz gain-bandwidth product. Place the amplifier and gain-setting resistor near the bridge sensor, keep excitation wiring away from digital circuits, and use the amplifier’s external reference to establish the output midpoint when the system is single-supply. The achievable gain and output swing must remain within the datasheet limits.

💊

Low-Level Pressure Sensing

The INA115BUG4 can condition millivolt-level pressure-sensor outputs when low offset and low noise are more important than wide bandwidth. Its 50 µV input offset voltage and 11 nV/√Hz noise density provide the core performance needed to preserve small differential signals, while the 1 MHz gain-bandwidth product supports practical sensor bandwidth. Use short, guarded input traces and verify the selected external gain resistor against the INA115 datasheet. The output reference should be configured carefully in single-supply systems to preserve bidirectional measurement range.

⚖️

Load Cell and Weighing Systems

A load cell produces a small differential voltage proportional to applied force, making the INA115BUG4 suitable for precision weighing and force measurement. Its three-op-amp instrumentation topology supports accurate differential amplification, and the 50 µV offset specification helps control errors near the signal floor. Connect the load-cell excitation and return in a symmetrical layout, keep the input loop small, and use a dedicated analog ground region to prevent motor or heater currents from entering the measurement path. Gain and common-mode limits must be checked for the full load-cell range.

⚡

Industrial Current Sensing

The INA115BUG4 can amplify the differential voltage generated by a current-shunt or current-sense element in industrial monitoring equipment. Its 11 nV/√Hz input noise density and 50 µV offset voltage are useful when the measured current produces a relatively small differential voltage. Route the shunt connections as a tight differential pair, use a Kelvin-style connection where possible, and keep the shunt’s high-current path separate from the amplifier’s reference and ground circuitry. Confirm that the shunt voltage remains inside the amplifier’s common-mode range.

💊

Biomedical Signal Acquisition

The INA115BUG4 is suitable for low-amplitude biomedical front ends where offset and input noise can affect measurement quality. Its 11 nV/√Hz noise density, 50 µV offset voltage, and differential input structure support conditioning of small sensor-derived signals, while the 1 MHz bandwidth exceeds many physiological-signal requirements. Protection, isolation, leakage, and patient-safety requirements must be evaluated separately; the amplifier itself is not automatically a complete medical front end. Follow the manufacturer application guidance and validate the complete patient-connected circuit for safety.

🌐

Process and Environmental Monitoring

The INA115BUG4 fits process-control front ends that measure small differential signals from thermocouple amplifiers, strain gauges, or resistive sensors. The instrumentation-amplifier architecture provides differential input handling and gain adjustment in a compact 16-SOIC package. Its 1 MHz bandwidth supports moderate-bandwidth sensing, while the 50 µV offset and 11 nV/√Hz noise density help retain low-level measurement information. Use dedicated analog grounding, isolate the input route from relay and switching circuits, and verify the output range against the controller’s input limits.

What is the INA115BUG4?
The INA115BUG4 is a precision, three-op-amp instrumentation amplifier from Texas Instruments with a 1 MHz gain-bandwidth product and a 16-pin SOIC package. According to the Texas Instruments product page, it provides 50 µV input offset voltage, 11 nV/√Hz input noise, and 3 mA power consumption, making it suitable for low-level differential sensor measurements.
What is the operating voltage of INA115BUG4?
The INA115BUG4 operates from a 2.25 V to 18 V supply according to the INA115BU comparison data published for this family. The product listing also identifies a 50 V maximum supply rating, so the circuit designer must reconcile normal operating voltage, absolute maximum conditions, and protection requirements before applying the device.
Where can I download the INA115BUG4 datasheet PDF?
The official INA115 datasheet is available through the Texas Instruments literature URL at https://www.ti.com/lit/gpn/INA115. The device data sheet describes the precision instrumentation amplifier, its three-op-amp architecture, electrical characteristics, gain configuration, pin functions, and application information needed for circuit design.
Where can I find the INA115BUG4 pinout?
The INA115BUG4 pin assignment is published in the official Texas Instruments INA115 datasheet at https://www.ti.com/lit/gpn/INA115. Use the pin-description table and package drawing when assigning PCB nets, particularly the differential inputs, feedback resistor connections, reference input, supply pins, and output.
How is the gain of the INA115BUG4 set?
The INA115BUG4 uses external resistors to establish the instrumentation-amplifier gain. According to the Texas Instruments datasheet, the additional A1 and A2 input-amplifier connections improve gain accuracy at high gains and can assist with switched-gain configurations. The exact resistor equation and permitted gain range must be taken from the datasheet.
What are the key specifications of INA115BUG4 that engineers should know?
The principal INA115BUG4 specifications are 1 MHz gain-bandwidth product, 50 µV input offset voltage, 11 nV/√Hz input noise density, 3 mA power consumption, and a 2.25 V to 18 V supply range. These figures come from the Texas Instruments product page and INA115 family comparison information and should be checked against operating gain and temperature requirements.
Is INA115BUG4 suitable for low-noise sensor measurement?
Yes, the INA115BUG4 is suitable for many low-level differential sensor measurements because its input noise density is 11 nV/√Hz and its input offset voltage is 50 µV. The Texas Instruments product page identifies the part as a precision instrumentation amplifier. Actual signal-to-noise performance also depends on gain, bandwidth, resistor selection, and reference quality.
INA115BUG4 vs INA115BU — which one should I choose?
The INA115BUG4 and INA115BU are both shown as 16-SOIC instrumentation amplifiers with a 1 MHz bandwidth and 2.25 V to 18 V supply range. The BUG4 ordering code is the requested assembly variant, while INA115BU is listed as the base-family device. Confirm temperature grade, reel or tube format, marking, and lead-time requirements before treating either ordering code as interchangeable.
When should I choose INA115BUG4 instead of INA115BU?
Choose INA115BUG4 when the specified orderable assembly is required by the BOM or production system. Both parts are identified as 16-SOIC members of the INA115 family, but their ordering suffixes may encode packaging, temperature, or qualification details. Confirm those details against the current Texas Instruments ordering information before final procurement.
What can replace INA115BUG4?
INA115BU is the closest documented replacement candidate because the comparison data identifies it as the same INA115 16-SOIC instrumentation-amplifier family with matching 1 MHz bandwidth and 2.25 V to 18 V supply range. However, a true drop-in substitution also requires matching pin functions, gain resistor connections, temperature grade, and production specifications before PCB release.
Is INA115BUG4 pin compatible with INA118U?
INA118U appears in comparison data against INA115BUG4, but the information does not establish complete pin-to-pin compatibility. INA118 is a different instrumentation-amplifier family and may differ in gain architecture, reference implementation, supply range, and exact pin assignments. Use the manufacturer pin tables rather than assuming that a shared 16-SOIC outline guarantees drop-in replacement.
What is the best cross-brand equivalent for INA115BUG4?
No cross-brand equivalent can be responsibly identified as drop-in from the available manufacturer and comparison information. A valid replacement must match the 16-pin footprint, supply range, gain-setting method, input and output functions, bandwidth, offset voltage, noise, and operating temperature. The Request a Quote form can be used to request current sourcing support for a qualified equivalent.
Where can I buy INA115BUG4 and what is its price?
Use the Request a Quote form on this page to request current INA115BUG4 availability, pricing, minimum order quantity, and lead time. The request can specify the required 16-SOIC package, production quantity, and assembly format so the supply response is tied to the exact INA115BUG4 ordering code.
How much lead time is required for INA115BUG4?
Current lead time should be requested through the Request a Quote form on this page. Lead time can depend on order quantity, manufacturing status, allocation, package format, and incoming production schedules. Provide the forecast quantities and required delivery dates with the inquiry to obtain a more actionable schedule.
Is INA115BUG4 in stock?
Current stock status should be confirmed through the Request a Quote form on this page because availability can change with order volume and production allocation. Include the exact INA115BUG4 MPN, required package form, annual usage, and requested delivery date when requesting a supply response.
Does INA115BUG4 need special PCB layout for low noise?
Yes, the INA115BUG4 should be placed close to its feedback and gain-setting resistors, and sensitive input traces should be kept away from switching converters, high-current return paths, and digital timing nodes. According to the Texas Instruments datasheet description, the A1 and A2 connections are intended to support accurate high-gain operation. A quiet analog ground and controlled reference return are also important.

工程參考資料,適用於 INA115BUG4 — 比較、設計指引及合規資訊。

選型指南

Choose the INA115BUG4 when your design needs a precision instrumentation amplifier for low-level differential signals and the exact BUG4 ordering code is required by the BOM. Its documented combination of 1 MHz bandwidth, 50 µV offset voltage, 11 nV/√Hz noise density, and 3 mA operating power suits bridge sensors, pressure transducers, load cells, and current-sense circuits. INA115BU is the closest documented family candidate because it is identified as a 16-SOIC INA115 device with the same bandwidth and supply range; use it only after confirming its pin functions, temperature grade, and orderable configuration. INA118U, INA117KU/2K5, and other instrumentation amplifiers should not be treated as automatic drop-ins because their gain architecture, fixed or adjustable gain, reference behavior, and exact pin assignments may differ. For designs with strict noise, common-mode, and layout requirements, validate the complete sensor, gain network, reference, grounding, and protection chain against the manufacturer datasheet.

與替代品比較

參數 本產品 INA115BU
Brand Texas Instruments Texas Instruments
Package 16-SOIC (0.295", 7.50 mm width) 16-SOIC
Product Type Precision instrumentation amplifier Instrumentation amplifier
Gain-Bandwidth Product 1 MHz 1 MHz
Supply Voltage Range 2.25 V to 18 V 2.25 V to 18 V
Slew Rate 0.6 V/µs 0.6 V/µs
Maximum Supply Voltage 50 V 50 V
Amplifier Count 3 amplifiers 1 amplifier

主要差異化特點

  • Wide bandwidth within a general-purpose precision instrumentation amplifier (對比INA115BU)
  • Low 11 nV/√Hz input noise density (對比INA115BU)
  • Low 50 µV input offset voltage (對比INA115BU)
  • Low 3 mA operating power (對比INA115BU)

設計說明

Place the INA115BUG4, gain-setting resistors, and optional input filters close together to minimize parasitic resistance and capacitance on the high-impedance input nodes. Route the differential inputs as a compact pair, avoid routing them beneath switching regulators or digital return paths, and use the A1 and A2 connections exactly as shown in the manufacturer datasheet for accurate high-gain operation.

The 11 nV/√Hz noise density is meaningful only when the complete input network has acceptable thermal noise and the gain is selected for the required signal bandwidth. Verify the external gain resistor and compensation values from the Texas Instruments datasheet, avoid excessive bandwidth when a narrow-band sensor is used, and confirm that input capacitance, common-mode range, and output swing support the intended operating point.

Do not assume that a shared 16-SOIC outline guarantees drop-in compatibility. INA115BU is the closest documented family candidate, but production substitutions must also match pin functions, gain-setting architecture, reference behavior, temperature grade, and ordering details. Review the manufacturer pin-description table and ordering information before approving a replacement for INA115BUG4.

The INA115BUG4 consumes approximately 3 mA under the manufacturer-described operating condition. Supply decoupling should be placed close to the power and ground pins, while analog measurement returns should remain separate from noisy power currents. Validate the reference source for noise and stability because reference variation can directly affect output accuracy independently of the amplifier’s input noise.

合規資訊

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
無鉛
Unknown
無鹵
Unknown
衝突礦產
Unknown

The INA115 family comparison information discusses RoHS and REACH, but no explicit compliance declaration for the INA115BUG4 ordering code was available. AEC-Q100 is not applicable to this general-purpose precision analog device.

相關搜尋

INA115BUG4 datasheet INA115BUG4 pinout INA115BUG4 datasheet pdf INA115BUG4 equivalent INA115BUG4 replacement INA115BUG4 cross reference INA115BUG4 price INA115BUG4 stock INA115BUG4 footprint INA115BUG4 application circuit INA115BUG4 vs INA115BU Texas Instruments INA115BUG4 INA115 16-SOIC pinout 1 MHz instrumentation amplifier 3 mA

相關元件與詞彙

Texas Instruments INA115BUG4 INA115BU INA118U INA117KU/2K5 precision instrumentation amplifier instrumentation amplifier differential amplifier analog amplifier analog signal-chain IC gain-bandwidth product input offset voltage input noise density power consumption common-mode rejection three-op-amp architecture A1 connection A2 connection switched-gain configuration 16-SOIC SOIC package family surface mount bridge sensor load cell pressure sensor
快速報價 RFQ
請填寫完整詳細資料 — 我們的業務團隊將於 24 小時內回覆
料號 製造商 封裝 QTY 目標價格 小計
✓
報價已提交!

我們將於 24 小時內回覆您的電子郵件

1
詢價已提交
2
已收到報價
3
已下單
4
付款
5
已出貨
6
已送達
檢視詢價單詳情