INA125UA/2K5 - 2.5 Gain Instrumentation Amplifier | Texas Instruments
部品番号: INA125UA/2K5 ✓ 生産中INA125UA/2K5 概要
An instrumentation amplifier is a specialized analog amplifier used to process low-level differential signals. The INA125UA/2K5 provides a fixed gain arrangement identified by the 2K5 suffix and is intended for systems requiring repeatable signal conditioning before conversion or measurement. Its package construction supports surface-mount PCB assembly, while the UA designation corresponds to the manufacturer’s packaging family used for this device.
The primary design benefits of the INA125UA/2K5 are its dedicated instrumentation-amplifier function, fixed 2.5 gain configuration, and suitability for precision analog signal chains. A fixed-gain device can simplify analog front-end design because the gain-setting network does not need to be adjusted in the finished system. It is particularly useful when the sensor or transducer produces a differential output and the downstream converter, controller, or measurement instrument requires a consistently scaled single-ended signal.
Typical use cases include bridge-sensor excitation and readout, industrial process measurement, laboratory instrumentation, low-level sensor interfaces, and analog front ends for data-acquisition systems. The device can also be used where a small differential signal is embedded in a larger common-mode voltage. The instrumentation-amplifier architecture helps preserve signal integrity when both input terminals are exposed to similar external voltages or noise sources.
For PCB implementation, use the manufacturer pin description table and package drawing when assigning signals. Input routing should be short and symmetric, and the input and output return paths should be referenced consistently to minimize conversion of common-mode noise into differential error. Bypass and filtering components should be placed according to the manufacturer’s recommended application circuit rather than added arbitrarily. The INA125UA/2K5 is a fixed-gain analog component, so supply voltage, common-mode range, input offset, noise, bandwidth, and operating-temperature limits must be checked against the exact system requirements before production release.
This product page summarizes the INA125UA/2K5 role, package, application fit, and design considerations while directing engineers to the manufacturer datasheet for authoritative electrical limits and test conditions. The part is best selected by comparing its fixed 2.5 gain behavior, analog signal requirements, and package compatibility with the complete instrumentation chain.
ドロップイン代替品: INA125UA/2K5 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA125UA/2K5 (同一形状・フットプリント) — 相違点: Product Type, Package, Gain Range, Quiescent Current, Mounting Type.
INA125UA
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →INA125PWR
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
INA126P
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →INA128PA
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →INA129U/2K5
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →INA132U
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →INA125UA/2K5 最大定格&電気的特性
| Device Type | Precision instrumentation amplifier |
| Gain Configuration | Fixed 2.5 gain |
| Package Designation | UA |
| 実装タイプ | Surface Mount |
INA125UA/2K5 ua ピン配置ガイド
INA125UA/2K5 (ua パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: INA125UA/2K5.
詳細は データシート をご参照ください。
主な用途
INA125UA/2K5 の用途: 6 件s: Bridge-Sensor Signal Conditioning, Industrial Process Measurement, Precision Data-Acquisition Front End, Laboratory Measurement Instrumentation, Pressure and Strain Transducer Readout, Audio and Low-Level Analog Interfaces.
Bridge-Sensor Signal Conditioning
INA125UA/2K5 is appropriate for bridge-based measurement systems in which the sensor produces a small differential signal across a common-mode voltage. The fixed 2.5 gain provides a defined scaling relationship before the signal reaches an ADC or instrumentation block. Place the amplifier close to the bridge outputs, route the differential pair symmetrically, and confirm that the bridge excitation and output remain inside the device’s input limits. Proper grounding and filtering are important because bridge imbalance, lead resistance, and sensor noise can affect measurement accuracy.
おすすめ
Industrial Process Measurement
The INA125UA/2K5 can amplify low-level differential process signals before industrial control circuitry evaluates them. Its fixed 2.5 gain simplifies repeatable signal scaling, while the instrumentation-amplifier configuration is useful when the measurement input shares a substantial common-mode voltage with the sensing element. The design should include protection against transients, verify input common-mode limits at the highest process voltage, and isolate the analog path from switching nodes and motor power stages.
おすすめ
Precision Data-Acquisition Front End
Use INA125UA/2K5 as the analog gain stage ahead of a data-acquisition converter when a fixed differential-to-single-ended scaling is appropriate. The 2.5 gain relationship can be included in calibration, and the dedicated instrumentation-amplifier function helps reduce common-mode interference. The key design checks are input offset, noise, bandwidth, settling behavior, and output settling into the ADC. Use the manufacturer’s recommended bypass and reference arrangements, and account for the ADC input range during startup and overload conditions.
おすすめ
Laboratory Measurement Instrumentation
INA125UA/2K5 is useful in laboratory instruments that measure low-level differential sensor outputs and require stable, repeatable scaling. The fixed gain can make calibration and calibration tables simpler than with an adjustable design. For instrument-grade performance, evaluate offset, input noise, common-mode rejection, and temperature drift against the measurement resolution target. Keep sensitive input routing away from digital return currents and use clean grounding to prevent lab power-supply noise from appearing as measurement error.
おすすめ
Pressure and Strain Transducer Readout
The INA125UA/2K5 can serve as the differential amplification stage for pressure or strain transducers whose outputs are small relative to the excitation voltage. A fixed 2.5 gain provides a predictable relationship between transducer output and the downstream measurement device. Check the transducer excitation level, bridge or strain-gauge impedance, input bias-current error, and sensor output polarity before finalizing the circuit. Add filtering only where its interaction with bandwidth and settling has been evaluated.
おすすめ
Audio and Low-Level Analog Interfaces
INA125UA/2K5 can be evaluated for low-level differential analog interfaces where a fixed gain of 2.5 is appropriate and common-mode rejection is more important than maximum flexibility. The amplifier’s role is to condition a balanced or differential source before further processing. For audio-adjacent circuitry, verify noise density, frequency response, distortion, output swing, and supply range; these characteristics are not established by the available product information. Confirm that the 2.5 gain does not overload the source or downstream converter.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA125UA/2K5 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA125UA | INA125PWR | INA126 | INA128 | INA129 |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Function | Precision instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier |
主な差別化要因
- Fixed 2.5 gain configuration (vs INA125UA)
- Dedicated instrumentation-amplifier signal conditioning (vs INA126)
- Same-brand ecosystem for sourcing and validation (vs INA128)
設計ノート
Route the INA125UA/2K5 differential inputs as a short, matched pair and connect the input return to the same reference used by the source. Keep the traces away from switching power nodes and high-current return paths. Place input and output bypass components at the pins according to the manufacturer application circuit, and preserve a continuous ground reference to minimize common-mode-to-differential conversion.
Check the complete signal chain for clipping, settling, and ADC acquisition timing rather than relying on nominal 2.5 gain alone. Confirm that the differential input remains within the common-mode range, that the output does not exceed the downstream input range, and that the selected bandwidth supports the measurement bandwidth. Add anti-alias or noise filtering only after accounting for its effect on phase, noise, and settling behavior.
Do not substitute an amplifier based only on the UA package or the nominal gain designation. The INA125UA/2K5 ordering code, pin assignment, supply rating, common-mode range, offset, noise, and bandwidth must all be verified before reuse on an existing PCB. For PCB replacement, compare the manufacturer pinout and application circuit directly, especially when a different INA family member has a different gain suffix.