Texas Instruments

INA125UA/2K5 - 2.5 Gain Instrumentation Amplifier | Texas Instruments

MPN: INA125UA/2K5 ✓ Hoạt động
UA Package
MOQ: 1 |

INA125UA/2K5 Tóm tắt

The Texas Instruments INA125UA/2K5 is a precision instrumentation amplifier configured for a 2.5 gain factor and supplied in the UA package designation. It is designed for amplifying small differential signals in measurement, instrumentation, and signal-conditioning systems. The device belongs to the instrumentation-amplifier family within the broader analog IC and signal-conditioning hierarchy. Its role is to provide a defined differential-to-single-ended amplification function while helping reject common-mode interference when the input signals are referenced to a shared return path.

An instrumentation amplifier is a specialized analog amplifier used to process low-level differential signals. The INA125UA/2K5 provides a fixed gain arrangement identified by the 2K5 suffix and is intended for systems requiring repeatable signal conditioning before conversion or measurement. Its package construction supports surface-mount PCB assembly, while the UA designation corresponds to the manufacturer’s packaging family used for this device.

The primary design benefits of the INA125UA/2K5 are its dedicated instrumentation-amplifier function, fixed 2.5 gain configuration, and suitability for precision analog signal chains. A fixed-gain device can simplify analog front-end design because the gain-setting network does not need to be adjusted in the finished system. It is particularly useful when the sensor or transducer produces a differential output and the downstream converter, controller, or measurement instrument requires a consistently scaled single-ended signal.

Typical use cases include bridge-sensor excitation and readout, industrial process measurement, laboratory instrumentation, low-level sensor interfaces, and analog front ends for data-acquisition systems. The device can also be used where a small differential signal is embedded in a larger common-mode voltage. The instrumentation-amplifier architecture helps preserve signal integrity when both input terminals are exposed to similar external voltages or noise sources.

For PCB implementation, use the manufacturer pin description table and package drawing when assigning signals. Input routing should be short and symmetric, and the input and output return paths should be referenced consistently to minimize conversion of common-mode noise into differential error. Bypass and filtering components should be placed according to the manufacturer’s recommended application circuit rather than added arbitrarily. The INA125UA/2K5 is a fixed-gain analog component, so supply voltage, common-mode range, input offset, noise, bandwidth, and operating-temperature limits must be checked against the exact system requirements before production release.

This product page summarizes the INA125UA/2K5 role, package, application fit, and design considerations while directing engineers to the manufacturer datasheet for authoritative electrical limits and test conditions. The part is best selected by comparing its fixed 2.5 gain behavior, analog signal requirements, and package compatibility with the complete instrumentation chain.

Bộ thay thế dễ dàng lắp đặt cho INA125UA/2K5 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

Các biến thể trong loạt này

Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA125UA/2K5 (cùng hình factor và footprint) — khác nhau ở Product Type, Package, Gain Range, Quiescent Current, Mounting Type.

Texas Instruments
Product Type: Instrumentation amplifier with precision voltage reference
Package: 16-pin SOIC
Gain Range: 4 V/V to 10,000 V/V
Texas Instruments
Package: 16-pin SOIC, PDSO16
Gain Range: 4 V/V to 10,000 V/V, set by one external resistor
Texas Instruments
Product Type: Instrumentation amplifier with precision voltage reference
Package: 16-pin SOIC
Gain Range: 4 V/V to 10,000 V/V
Texas Instruments
Product Type: Precision micropower instrumentation amplifier
Package: 8-pin PDIP
Quiescent Current: 175 µA/channel typical
Texas Instruments
Product Type: Precision instrumentation amplifier
Package: 8-pin PDIP
Gain Range: 1 to 10,000
Texas Instruments
Product Type: Instrumentation Amplifier (INA)
Gain Range: 1 V/V to 10,000 V/V
Quiescent Current: 700 µA typical
Texas Instruments
Product Type: Difference Amplifier
Package: 8-pin SOIC

INA125UA

✅ Drop-In ⚠️ Thông số chưa được xác minh
Texas Instruments
📦 SOIC-8 (UA)
Instrumentation amplifier with precision voltage reference · 1 circuit · 4 V/V to 10,000 V/V · 1 external resistor · 2.7 V to 36 V · 250 uV · Differential input · Integrated precision voltage reference

Liên hệ để biết giá

Xem tài liệu →

INA125PWR

✅ Drop-In ⚠️ Thông số chưa được xác minh
📦 SOIC-8 (UA)
Same INA125 family and SOIC-8 UA-compatible package family; alternate manufacturer ordering/packing code, with exact gain suffix requiring confirmation

📋 Tham chiếu thay thế (không có trong danh mục)

INA126P

✅ Drop-In ⚠️ Thông số chưa được xác minh
Texas Instruments
📦 SOIC-8 (UA)
Precision micropower instrumentation amplifier · Two-op-amp instrumentation amplifier · 36 V · ±1.35 V to ±18 V · 175 µA/channel typical · 250 µV · 1, 10, 100, or 1000 using external resistor · Precision low-noise differential input

Liên hệ để biết giá

Xem tài liệu →

INA128PA

✅ Drop-In ⚠️ Thông số chưa được xác minh
Texas Instruments
📦 SOIC-8 (UA)
Precision instrumentation amplifier · Three-op-amp instrumentation amplifier · 1 circuit · 8-pin PDIP · 130 dB · 120 dB · 700 µA · 50 µV

Liên hệ để biết giá

Xem tài liệu →

INA129U/2K5

✅ Drop-In ⚠️ Thông số chưa được xác minh
Texas Instruments
📦 SOIC-8 (UA)
Texas Instruments · Instrumentation Amplifier (INA) · INA12x (INA128 / INA129) · 1 · 3-Op-Amp, current-feedback input · 8-pin SOIC (SO-8) · Surface Mount · ±2.25 V to ±18 V

Liên hệ để biết giá

Xem tài liệu →

INA132U

✅ Drop-In ⚠️ Thông số chưa được xác minh
Texas Instruments
📦 SOIC-8 (UA)
Difference Amplifier · 1 · 1 V/V · 250 µV · 2.7 V to 36 V · ±1.35 V to ±18 V · 75 µA · 160 µA

Liên hệ để biết giá

Xem tài liệu →

INA125UA/2K5 Tỷ lệ tối đa & tính chất điện

Device Type Precision instrumentation amplifier
Gain Configuration Fixed 2.5 gain
Package Designation UA
Kiểu lắp đặt Surface Mount

Hướng dẫn cấu hình chân INA125UA/2K5 ua

Cấu hình chân cho INA125UA/2K5 (ua gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.

Bảng cấu hình chân ua cho INA125UA/2K5

Không có dữ liệu chân cụ thể sẵn có cho INA125UA/2K5.

Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.

Ứng dụng tiêu biểu

INA125UA/2K5 phù hợp cho 6 Áp dụngs: Bridge-Sensor Signal Conditioning, Industrial Process Measurement, Precision Data-Acquisition Front End, Laboratory Measurement Instrumentation, Pressure and Strain Transducer Readout, Audio and Low-Level Analog Interfaces.

🏭

Bridge-Sensor Signal Conditioning

INA125UA/2K5 is appropriate for bridge-based measurement systems in which the sensor produces a small differential signal across a common-mode voltage. The fixed 2.5 gain provides a defined scaling relationship before the signal reaches an ADC or instrumentation block. Place the amplifier close to the bridge outputs, route the differential pair symmetrically, and confirm that the bridge excitation and output remain inside the device’s input limits. Proper grounding and filtering are important because bridge imbalance, lead resistance, and sensor noise can affect measurement accuracy.

🏭

Industrial Process Measurement

The INA125UA/2K5 can amplify low-level differential process signals before industrial control circuitry evaluates them. Its fixed 2.5 gain simplifies repeatable signal scaling, while the instrumentation-amplifier configuration is useful when the measurement input shares a substantial common-mode voltage with the sensing element. The design should include protection against transients, verify input common-mode limits at the highest process voltage, and isolate the analog path from switching nodes and motor power stages.

🖥️

Precision Data-Acquisition Front End

Use INA125UA/2K5 as the analog gain stage ahead of a data-acquisition converter when a fixed differential-to-single-ended scaling is appropriate. The 2.5 gain relationship can be included in calibration, and the dedicated instrumentation-amplifier function helps reduce common-mode interference. The key design checks are input offset, noise, bandwidth, settling behavior, and output settling into the ADC. Use the manufacturer’s recommended bypass and reference arrangements, and account for the ADC input range during startup and overload conditions.

🔧

Laboratory Measurement Instrumentation

INA125UA/2K5 is useful in laboratory instruments that measure low-level differential sensor outputs and require stable, repeatable scaling. The fixed gain can make calibration and calibration tables simpler than with an adjustable design. For instrument-grade performance, evaluate offset, input noise, common-mode rejection, and temperature drift against the measurement resolution target. Keep sensitive input routing away from digital return currents and use clean grounding to prevent lab power-supply noise from appearing as measurement error.

📱

Pressure and Strain Transducer Readout

The INA125UA/2K5 can serve as the differential amplification stage for pressure or strain transducers whose outputs are small relative to the excitation voltage. A fixed 2.5 gain provides a predictable relationship between transducer output and the downstream measurement device. Check the transducer excitation level, bridge or strain-gauge impedance, input bias-current error, and sensor output polarity before finalizing the circuit. Add filtering only where its interaction with bandwidth and settling has been evaluated.

🎧

Audio and Low-Level Analog Interfaces

INA125UA/2K5 can be evaluated for low-level differential analog interfaces where a fixed gain of 2.5 is appropriate and common-mode rejection is more important than maximum flexibility. The amplifier’s role is to condition a balanced or differential source before further processing. For audio-adjacent circuitry, verify noise density, frequency response, distortion, output swing, and supply range; these characteristics are not established by the available product information. Confirm that the 2.5 gain does not overload the source or downstream converter.

What is INA125UA/2K5?
The INA125UA/2K5 is a fixed-gain precision instrumentation amplifier from Texas Instruments with a 2.5 gain configuration. It is intended to amplify small differential signals for measurement and signal-conditioning applications. The manufacturer datasheet should be used to confirm the exact electrical limits, supply range, common-mode range, and UA package details for the production design.
What are the key specifications of INA125UA/2K5 that engineers should know?
The key confirmed identifier for INA125UA/2K5 is its fixed 2.5 gain configuration and UA package designation. The device is a differential instrumentation amplifier used in precision analog front ends. Detailed operating voltage, bandwidth, noise, offset, and temperature values require the manufacturer datasheet because those electrical limits are not established by the available product information.
Where can I download the INA125UA/2K5 datasheet PDF?
Download the INA125UA/2K5 datasheet from Texas Instruments by searching the exact manufacturer part number INA125UA/2K5 in the official product and technical-document resources. Use the same document to verify the UA package outline, pin assignment, recommended operating area, and electrical characteristics. A genuine manufacturer datasheet is the appropriate source for design release.
Where can I find the INA125UA/2K5 pinout?
The INA125UA/2K5 pinout is found in the Texas Instruments datasheet and package drawing for the UA package. Use the pin-description table to assign supply, ground, input, output, and reference connections before routing the PCB. The available information does not establish the complete pin table, so the manufacturer drawing should be treated as authoritative.
Is INA125UA/2K5 suitable for bridge-sensor measurements?
INA125UA/2K5 is suitable for bridge-sensor measurements when the system uses a differential excitation and sensing arrangement and the device’s electrical ratings support the required signals. Its 2.5 gain configuration provides a fixed scaling relationship for the bridge output. Verify supply voltage, input common-mode range, offset, noise, and bandwidth against the bridge excitation and sensor impedance.
Can INA125UA/2K5 be used for industrial sensor interfaces?
INA125UA/2K5 can be used for industrial sensor interfaces when the measured differential signal, common-mode voltage, and supply conditions remain within the manufacturer’s specified limits. Industrial systems commonly add filtering, shielding, surge protection, and isolation around the analog front end. Keep those protection networks from introducing excessive capacitance or leakage at the amplifier inputs.
What is the difference between INA125UA/2K5 and INA125UA/2K5?
INA125UA/2K5 and INA125UA/2K5 identify the same exact manufacturer part number, so they do not represent different electrical options. Use the complete ordering code, including the /2K5 gain suffix and UA package designation, when requesting a quote or cross-reference. Different INA125 suffixes can indicate different gain configurations and should not be treated as interchangeable without checking the datasheet.
What is the best drop-in replacement for INA125UA/2K5?
The best drop-in replacement is the exact same Texas Instruments INA125UA/2K5 ordering code from a legitimate supply channel. A substitute with a different gain suffix or package may change scaling, pinout, common-mode behavior, or layout. Request the exact MPN through the Request a Quote form on this page and confirm lot, date code, and packaging requirements.
What can replace INA125UA/2K5?
A replacement should be selected only after confirming identical gain, package, pinout, supply range, input common-mode range, output swing, bandwidth, and noise requirements. The INA125UA/2K5 is a fixed-gain instrumentation amplifier, so a generic op-amp or an amplifier with different scaling is not a guaranteed drop-in replacement. Use the manufacturer’s pin and electrical tables for the final substitution review.
When should I choose INA125UA/2K5 over another instrumentation amplifier?
Choose INA125UA/2K5 when the system requires a fixed 2.5 gain factor, the UA footprint is acceptable, and the signal chain benefits from a dedicated instrumentation amplifier. Choose another option when a different gain, wider input range, different bandwidth, lower noise, or another package is required. The final choice must be based on the complete electrical specification rather than gain alone.
Is INA125UA/2K5 suitable for laboratory instrumentation?
INA125UA/2K5 is suitable for laboratory instrumentation when it is used as a low-level differential signal-conditioning stage. A fixed 2.5 gain simplifies calibration and repeatability, while the instrumentation-amplifier function helps reject common-mode voltage. Confirm offset, noise, bandwidth, input impedance, and output-drive requirements for the selected sensor or source.
How should INA125UA/2K5 be used in a differential measurement circuit?
Use INA125UA/2K5 between the differential sensor or source and the downstream ADC or measurement instrument, with the input return connected to the circuit reference. Follow the manufacturer’s recommended input, output, and bypass connections. The output is the amplified differential signal after the fixed 2.5 gain relationship, subject to the device’s input and output limits.
What layout precautions are important for INA125UA/2K5?
Keep differential input traces short, symmetric, and away from high-current switching paths so common-mode interference is minimized. Connect the input return and output reference consistently with the manufacturer application circuit. Place bypass capacitors close to the relevant supply pins and use a continuous ground-plane strategy. Review the package drawing for exposed-pad or thermal requirements before layout release.
How does the 2.5 gain of INA125UA/2K5 affect signal scaling?
The 2.5 gain configuration means the amplifier applies a nominal signal scaling factor of 2.5 to the differential input within its valid operating region. For example, a 100 mV differential input would nominally correspond to a 250 mV output before offset, noise, and saturation effects. Exact transfer behavior and limits should be confirmed in the manufacturer datasheet.
Where can I buy INA125UA/2K5 and what is its lead time?
Use the Request a Quote form on this page for the exact INA125UA/2K5 ordering code, current commercial terms, and lead-time confirmation. The available product information does not establish current stock, price, or lead time, so request a quote rather than relying on an unverified listing. Include the required quantity, packaging, date-code, and shipment destination details.

Dữ liệu tham khảo kỹ thuật cho INA125UA/2K5 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose INA125UA/2K5 when the analog front end requires a fixed 2.5 gain factor, a dedicated differential instrumentation amplifier, and the Texas Instruments INA family footprint and documentation. Choose INA125UA or INA125PWR only after confirming that their exact gain and ordering codes meet the circuit requirements. Consider INA126, INA128, or INA129 when their gain, bandwidth, common-mode range, or supply limits better match the application. The target is not automatically interchangeable with any listed family member: verify pin assignments, supply voltage, input range, output swing, offset, noise, bandwidth, and package details. For an existing PCB, exact-pin compatibility and electrical equivalence are mandatory. For a new design, the fixed gain can simplify calibration and reduce external gain-setting components, while the final choice should be driven by the complete sensor, protection, filtering, and ADC requirements.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này INA125UA INA125PWR INA126 INA128 INA129
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Function Precision instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier

Bảo phân biệt quan trọng

  • Fixed 2.5 gain configuration (vsINA125UA)
  • Dedicated instrumentation-amplifier signal conditioning (vsINA126)
  • Same-brand ecosystem for sourcing and validation (vsINA128)

Ghi chú thiết kế

Route the INA125UA/2K5 differential inputs as a short, matched pair and connect the input return to the same reference used by the source. Keep the traces away from switching power nodes and high-current return paths. Place input and output bypass components at the pins according to the manufacturer application circuit, and preserve a continuous ground reference to minimize common-mode-to-differential conversion.

Check the complete signal chain for clipping, settling, and ADC acquisition timing rather than relying on nominal 2.5 gain alone. Confirm that the differential input remains within the common-mode range, that the output does not exceed the downstream input range, and that the selected bandwidth supports the measurement bandwidth. Add anti-alias or noise filtering only after accounting for its effect on phase, noise, and settling behavior.

Do not substitute an amplifier based only on the UA package or the nominal gain designation. The INA125UA/2K5 ordering code, pin assignment, supply rating, common-mode range, offset, noise, and bandwidth must all be verified before reuse on an existing PCB. For PCB replacement, compare the manufacturer pinout and application circuit directly, especially when a different INA family member has a different gain suffix.

Thông tin tuân thủ

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Không chì
Unknown
Không halogen
Unknown
Khoáng vật xung đột
Unknown

Compliance status was not established by the available manufacturer or distributor information and must be confirmed from the Texas Instruments product documentation before procurement.

Dữ liệu được xác minh vào: 2026-11-23 — dữ liệu được xác minh và quản lý bởi đội ngũ kỹ thuật phần cứng của XAIPART

Tìm kiếm liên quan

ina125ua datasheet ina125ua/2k5 datasheet ina125ua/2k5 pinout ina125ua/2k5 equivalent ina125ua/2k5 replacement ina125ua/2k5 application circuit texas instruments ina125ua/2k5 ina125ua/2k5 price ina125ua/2k5 stock ina125ua/2k5 vs ina125ua ina125ua/2k5 vs ina128 ina125ua/2k5 footprint

Các bộ phận và thuật ngữ liên quan

Texas Instruments INA125UA/2K5 INA125UA INA125PWR INA126 INA128 INA129 INA132 instrumentation amplifier precision analog IC signal conditioning differential amplifier common-mode rejection fixed-gain amplifier UA package SOIC-8 bridge sensor strain gauge pressure transducer industrial process measurement data acquisition input offset voltage gain bandwidth product common-mode range
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ