INA326EA/2K5 - Precision Instrumentation Amplifier | TI
部品番号: INA326EA/2K5 ✓ 生産中INA326EA/2K5 概要
An instrumentation amplifier is a differential analog amplifier optimized for measuring small signals while rejecting common-mode interference. Its internal architecture provides high input impedance, accurate differential gain, and controlled output behavior, making it more suitable for bridge sensors, biopotential signals, and current-shunt measurements than a general-purpose operational amplifier. The INA326 belongs to the instrumentation amplifier, analog IC, and semiconductor hierarchy.
The INA326EA/2K5 combines a 0.1 V/V to 1000 V/V programmable gain range across the device family with a typical input offset voltage of 100 µV and input noise density of 33 nV/√Hz at 1 kHz. Rail-to-rail inputs increase usable signal range on low-voltage supplies, while the rail-to-rail output supports direct interface to low-voltage analog converters and control circuitry.
The amplifier uses a precision, low-drift CMOS implementation to improve DC accuracy over temperature and time. At its fixed gain of 25 V/V, the 1 kHz gain-bandwidth product limits the usable closed-loop bandwidth to approximately 40 kHz. This bandwidth-versus-precision balance favors stable sensing channels operating at low or moderate frequencies rather than high-speed waveform acquisition.
Typical uses include bridge-based pressure and strain measurements, ECG and biometric sensing, battery-current monitoring, industrial process-control instrumentation, and precision sensor interfaces. The 8-pin VSSOP package makes the device suitable for compact mixed-signal boards, while the single-supply operation simplifies portable and industrial equipment power architecture.
Designers should verify gain-bandwidth behavior, settling time, input common-mode range, and output swing against the signal bandwidth and supply voltage. Input filtering and proper grounding are important when the source has substantial differential impedance or when common-mode voltage approaches either supply rail.
This page combines the manufacturer ordering information, confirmed package and electrical characteristics, practical application guidance, and engineering-focused comparisons. It also distinguishes package-compatible family options from a verified drop-in replacement, helping engineers make a board-level decision without relying on packaging-only variants.
ドロップイン代替品: INA326EA/2K5 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
INA326EA/10K5
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
INA326EA/25K5
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
INA326EA/100K5
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
INA326EA/1K5
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
INA326EA/2K5 最大定格&電気的特性
| Device Type | Precision low-drift CMOS instrumentation amplifier |
| Number of Amplifiers | 1 amplifier |
| Fixed Gain | 25 V/V |
| Family Gain Range | 0.1 V/V to 1000 V/V |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Input Offset Voltage | ±100 µV maximum |
| Input Noise Density | 33 nV/√Hz typical at 1 kHz |
| Gain-Bandwidth Product | 1 MHz for the device family |
| Typical Closed-Loop Bandwidth at 25 V/V | 40 kHz |
| Input Topology | Rail-to-rail differential input |
| Output Topology | Rail-to-rail output |
| 動作温度範囲 | -40 °C to +85 °C |
| パッケージ | 8-pin VSSOP (DGK) |
| 実装タイプ | Surface mount |
| Supply Type | Single supply |
| RoHS ステータス | Compliant |
INA326EA/2K5 ピン構成
| ピン 1 | RG — Gain-setting resistor connection |
| ピン 2 | IN− — Inverting input |
| ピン 3 | IN+ — Noninverting input |
| ピン 4 | GND — Ground connection |
| ピン 5 | REF — Reference input |
| ピン 6 | OUT — Amplified output |
| ピン 7 | VS — Positive supply connection |
| ピン 8 | RG — Gain-setting resistor connection |
主な用途
INA326EA/2K5 の用途: 6 件s: Strain Gauge and Load Cell Acquisition, ECG and Biopotential Signal Conditioning, Battery Current and Power Monitoring, Industrial Process Sensor Interface, Portable Wearable Sensor Hub, Precision Analog-to-Digital Front End.
Strain Gauge and Load Cell Acquisition
The INA326EA/2K5 suits resistive strain gauges and load cells because its differential instrumentation-amplifier input measures the small bridge imbalance while rejecting much of the excitation-related common-mode voltage. A fixed gain of 25 V/V increases sensitivity without requiring an external gain network. Operating from 2.7 V to 5.5 V supports compact industrial and portable measurement equipment. Confirm the bridge excitation level, allowable common-mode range, and output swing so neither the input nor output saturates. The approximately 40 kHz bandwidth at 25 V/V is appropriate for static force measurements and low-frequency mechanical transients rather than high-frequency dynamic strain.
おすすめ
ECG and Biopotential Signal Conditioning
The INA326EA/2K5 can condition low-level biopotential signals because its instrumentation-amplifier topology provides high input impedance and differential sensing, while the 33 nV/√Hz typical input noise density at 1 kHz supports low-noise acquisition. The 25 V/V gain amplifies millivolt-scale signals before conversion, and the 2.7 V to 5.5 V operating range suits battery-powered wearables and portable medical equipment. System designers must still add electrode protection, input bias-current analysis, filtering, isolation where required, and a suitably low-noise reference. Its estimated 40 kHz bandwidth is more than adequate for typical ECG bandwidth while avoiding unnecessary wideband noise.
おすすめ
Battery Current and Power Monitoring
The INA326EA/2K5 is appropriate for measuring the voltage drop across a low-value current-sense resistor when the signal is differential and the common-mode voltage remains within the amplifier's operating limits. The fixed 25 V/V gain provides useful scaling for a shunt whose differential output is only a few millivolts. Rail-to-rail inputs help maximize usable signal range on low-voltage systems, while operation from 2.7 V to 5.5 V fits battery-powered equipment. Confirm common-mode limits at the highest load, shunt tolerance, Kelvin routing, and ADC input range. The low drift and ±100 µV maximum offset specification support repeatable current measurements after calibration.
おすすめ
Industrial Process Sensor Interface
The INA326EA/2K5 can serve as the analog front end for a process-control sensor producing a small differential output over a larger common-mode voltage. Its 25 V/V gain minimizes the required downstream ADC range, and the instrumentation-amplifier configuration simplifies input balancing compared with a discrete differential amplifier. The single 2.7 V to 5.5 V supply supports controller-compatible analog rails, while the 8-pin VSSOP (DGK) package supports compact analog front ends. Engineers should check sensor excitation, isolation boundaries, input filtering, common-mode range, and the 40 kHz estimated bandwidth. For very slow measurements, the INA326 family can pair naturally with a low-power delta-sigma ADC.
おすすめ
Portable Wearable Sensor Hub
The INA326EA/2K5 supports compact wearable and connected-sensor designs that need differential signal conditioning under a 2.7 V to 5.5 V supply. Rail-to-rail inputs increase usable headroom, while the 8-pin VSSOP package leaves board area for sensing, processing, and wireless functions. The fixed 25 V/V gain is useful for resistive or biopotential sensors whose outputs are too small for direct ADC acquisition. Because the device is a precision amplifier rather than a complete analog front end, the system still needs sensor excitation, filtering, ADC conversion, and suitable low-power sequencing. Use the rail-to-rail output only after verifying output-current demand and capacitive-load stability.
おすすめ
Precision Analog-to-Digital Front End
The INA326EA/2K5 provides the analog gain stage for a precision ADC front end when a small differential sensor signal must be scaled before conversion. Its fixed 25 V/V gain increases the ADC's effective input sensitivity, while the 1 MHz gain-bandwidth product provides an estimated 40 kHz signal bandwidth at that gain. This balance is suitable for temperature, pressure, force, and industrial transducer channels that do not require high-speed sampling. Use REF only as directed by the datasheet and evaluate offset, drift, and noise during calibration. A delta-sigma ADC is generally preferable when the signal bandwidth is low and the design needs excellent DC resolution rather than high sample rate.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA326EA/2K5 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA326EA/10K5 | INA326EA/25K5 | INA326EA/100K5 | INA326EA/1K5 |
|---|---|---|---|---|---|
| Package | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Fixed Gain | 25 V/V | 10 V/V | 25 V/V | 100 V/V | 1 V/V |
| Estimated Bandwidth at Fixed Gain | 40 kHz at 25 V/V | 100 kHz at 10 V/V | 40 kHz at 25 V/V | 10 kHz at 100 V/V | 1 MHz at 1 V/V |
| Supply Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V |
| Pricing Tier | Request a Quote | Request a Quote | Request a Quote | Request a Quote | Request a Quote |
主な差別化要因
- Balanced gain and bandwidth for precision sensing (vs INA326EA/100K5)
- Higher bandwidth than the 10 V/V option for the same class of signals (vs INA326EA/10K5)
- Instrumentation-amplifier signal conditioning rather than a single-ended current monitor (vs INA250A1PWR)
- Lower fixed-gain error sensitivity than a 1 V/V configuration (vs INA326EA/1K5)
設計ノート
Route IN+ and IN− as a closely matched differential pair away from switching nodes and high-current traces. If the source impedance is significant, compare the resistors connected to each input and account for amplifier input-current errors. Place optional input RC filters close to the amplifier pins, with matching components on both inputs, so differential noise and phase shift remain low.
Connect the supply bypass capacitor close to VS and provide a low-impedance ground return from GND. Keep the RG gain-setting components close to their pins and avoid sharing narrow return paths with motor, relay, or switching-converter currents. For the 8-pin VSSOP (DGK), verify pad dimensions, exposed thermal-pad requirements, solder mask, and paste pattern against the current Texas Instruments package drawing before releasing artwork.
Do not assume that any same-package instrumentation amplifier is a drop-in replacement. Verify the fixed gain, RG configuration, REF behavior, supply limits, input common-mode range, output swing, offset, noise, bandwidth, and exposed-pad requirements. Also confirm that the INA326EA/2K5 operating range of -40 °C to +85 °C matches the product's environmental requirements. A pin-compatible footprint alone does not guarantee equivalent measurement performance.
Use the REF pin only in configurations allowed by the Texas Instruments datasheet, because its bias and stability requirements affect output headroom. Decouple VS locally and provide a clean ground reference. For low-power systems, estimate quiescent-current consumption from the complete INA326 family documentation and confirm that the downstream ADC can be sequenced safely relative to the amplifier output. Avoid operating near an output or input limit where offset, noise, or recovery behavior becomes nonlinear.
コンプライアンス情報
RoHS-compliant status is listed by Mouser for the INA326 family. The industrial-temperature INA326EA/2K5 is not identified as an AEC-Q100-qualified automotive device.