INA333SJD - Precision Micro-Power Instrumentation Amplifier | TI
部品番号: INA333SJD ✓ 生産中INA333SJD 概要
An instrumentation amplifier is a differential-input amplifier designed to amplify a small voltage difference between two inputs while rejecting common-mode voltage. The INA333 belongs to the broader zero-drift amplifier family, combining an instrumentation-amplifier architecture with chopper-stabilized low-offset behavior. A zero-drift amplifier continuously corrects its own offset error, allowing low input-referred offset to remain stable over time and temperature.
The INA333SJD supports gains of 1, 10, 100, and 1000 through its RG pin. Manufacturer specifications identify a maximum offset voltage of 25 µV at a gain of 100, offset drift of 0.2 µV/°C at a gain of 1000, input noise of 55 nV/√Hz at a gain of 100, and minimum common-mode rejection of 100 dB at a gain of 10. Its 0.16 V/µs slew rate supports relatively slow sensor signals without requiring a high-speed amplifier.
The rail-to-rail output allows the output voltage to approach the supply rails, improving usable signal range in low-voltage systems. Gain is established by a single external resistor on the RG pin, simplifying circuit implementation while keeping the gain-setting component outside the amplifier. The measured gain error also depends on the tolerance and temperature coefficient of that resistor, so precision applications should use a suitable resistor network.
Typical uses include bridge-based pressure and strain measurements, low-current sensors, biomedical instrumentation, industrial process monitoring, and portable sensor systems. The device is particularly useful when sensor output is small, common-mode voltage is substantial, and thermal offset variation would otherwise dominate the measurement.
The principal design trade-off is bandwidth versus precision: the INA333 prioritizes low offset and low drift, while its 150 kHz gain-bandwidth product is modest compared with general-purpose high-speed amplifiers. Designers should also evaluate the high-temperature variant indicated by the INA333SJD ordering information and verify the complete electrical limits for the intended operating range.
This product page consolidates the verified manufacturer and distributor details, identifies the practical benefits of zero-drift operation, and organizes the device's gains, noise, offset, supply, package, and application constraints for faster engineering selection.
ドロップイン代替品: INA333SJD — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA333SJD (同一形状・フットプリント) — 相違点: Operating Temperature Range, Package, Slew Rate.
INA333D
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
INA333AIDGKR
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →INA333SJD 最大定格&電気的特性
| Amplifier Type | Instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Supply Voltage Range | 1.8 V to 5.5 V |
| Maximum Supply Voltage | 5.5 V |
| Gain-Bandwidth Product | 150 kHz |
| Slew Rate | 0.16 V/µs |
| Offset Voltage | 10 µV |
| Maximum Offset Voltage at Gain 100 | 25 µV |
| Offset Drift at Gain 1000 | 0.2 µV/°C |
| Input Noise at Gain 100 | 55 nV/√Hz |
| Minimum CMRR at Gain 10 | 100 dB |
| Input Bias Current | 2 nA |
| 出力タイプ | Rail-to-rail output |
| 動作温度範囲 | -55 °C to 210 °C |
| パッケージ | 8-pin SOIC-8 (JD) |
| 実装タイプ | Surface mount |
| Packaging | Tube |
INA333SJD ピン構成
| ピン 1 | R- — Inverting input and gain-setting resistor connection |
| ピン 2 | IN- — Inverting input |
| ピン 3 | IN+ — Noninverting input |
| ピン 4 | V- — Negative supply connection |
| ピン 5 | REF — Reference input |
| ピン 6 | OUT — Output voltage |
| ピン 7 | V+ — Positive supply connection |
| ピン 8 | RG — Gain-setting resistor connection |
主な用途
INA333SJD の用途: 6 件s: Strain-Gauge Bridge Measurements, Pressure and Load-Cell Signal Chains, Battery-Powered Sensor Interfaces, Biomedical and Diagnostic Instrumentation, Low-Current and Electrochemical Sensors, Industrial Process and Condition Monitoring.
Strain-Gauge Bridge Measurements
The INA333SJD is appropriate for resistive strain-gauge bridges because it combines low input bias current, low offset voltage, and high common-mode rejection in a compact 8-pin package. A bridge output is typically a small differential signal superimposed on a substantial excitation-centered common-mode voltage; the amplifier's 100 dB minimum CMRR at gain 10 helps reject that common-mode component. With a 3.3 V or 5 V supply and a suitable RG resistor, the rail-to-rail output provides more usable range than a fixed-headroom amplifier. The zero-drift architecture also helps maintain measurement stability as temperature changes, although gain error from the external resistor must be included in the system budget.
Pressure and Load-Cell Signal Chains
The INA333SJD can amplify low-level differential outputs from piezoresistive pressure sensors, load cells, and force transducers. Its 10 µV offset rating and 2 nA input bias current are important when the transducer has high source impedance or produces millivolt-level full-scale signals. The 0.16 V/µs slew rate is appropriate for slow-to-moderate mechanical events and industrial monitoring signals rather than high-frequency dynamic loading. For a bridge supplied from 5 V, the amplifier's 1.8 V to 5.5 V operating range supports the rail-to-rail output architecture, but the design must verify common-mode input limits, settling behavior, and the exact gain accuracy.
Battery-Powered Sensor Interfaces
The INA333SJD fits portable and battery-operated sensor systems that require accurate differential measurement at low supply voltage. Operation begins at 1.8 V, allowing the amplifier to operate alongside low-voltage sensors, analog-to-digital converters, and microcontrollers. Its micro-power design reduces the impact of continuous amplification on battery capacity, while the rail-to-rail output helps the signal approach the available supply range. For duty-cycled acquisition systems, verify settling time for the selected gain and confirm that the signal source's common-mode voltage remains within the device's electrical limits. A bypass capacitor near the supply pins should follow the manufacturer layout guidance.
Biomedical and Diagnostic Instrumentation
The INA333SJD is suitable for low-amplitude biomedical front ends such as ECG, EMG, plethysmography, and bioimpedance measurement blocks when the system operates within its specified electrical and environmental limits. The low input bias current helps prevent loading of high-impedance skin electrodes, while the low offset and zero-drift characteristics reduce baseline movement over time. The rail-to-rail output allows a compact analog front end to operate from a low-voltage supply and connect directly to an ADC. Safety-critical or patient-connected designs require separate review of isolation, leakage current, input protection, applied-part limits, and medical regulatory obligations beyond the amplifier's electrical specifications.
Low-Current and Electrochemical Sensors
The INA333SJD can serve as the precision input stage for electrochemical, gas, conductivity, and other sensors that generate small differential signals. Its 2 nA input bias current reduces the error generated when the sensor source impedance is high, while the 55 nV/√Hz noise specification at gain 100 establishes a useful baseline for many slow chemical-sensing systems. The instrumentation-amplifier topology simplifies differential excitation and sensing arrangements, although sensor-specific guarding, reference grounding, and polarity conventions still require careful review. The 150 kHz gain-bandwidth product is more than adequate for many concentration measurements but should be checked against transient response requirements in fast-flow or rapidly changing sensor systems.
Industrial Process and Condition Monitoring
The INA333SJD is useful in industrial process-monitoring equipment that measures thermocouple-like, bridge, or other low-level differential signals. The extended -55 °C to 210 °C ordering range makes it relevant to equipment operating across a broad environmental envelope, while its high common-mode rejection supports sensing in electrically noisy systems. The zero-drift architecture reduces time-dependent offset errors during long measurement cycles, which is valuable in stable process control. Designers should still place input filtering and ESD protection appropriately, keep sensitive traces away from switching nodes, and validate accuracy over the complete temperature range. The external RG resistor and reference network must also be reviewed for tolerance and thermal drift.
エンジニアリング参考データ: INA333SJD — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA333D | INA333AID |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | SOIC-8 (JD) | SOIC-8 - same package | SOIC-8 - same package |
| Amplifier Type | Micro-power zero-drift instrumentation amplifier | Zero-drift instrumentation amplifier | Zero-drift instrumentation amplifier |
| Output Type | Rail-to-rail output | Rail-to-rail output | Rail-to-rail output |
主な差別化要因
- Extended high-temperature operating range (vs INA333D)
- Low-offset precision architecture (vs INA333AID)
- Low-voltage operation with rail-to-rail output (vs INA333D)
設計ノート
Place the RG resistor close to pin 8 and keep the associated input and supply traces short and quiet. Connect the input bypass capacitor directly between the supply pins and ground, and route REF to a low-impedance reference network only when an offset adjustment is required. Maintain a continuous ground path beneath the sensitive input section, and avoid routing input traces beneath switching-regulator power stages, inductors, or high-current return paths.
Treat the INA333SJD as a precision, relatively low-bandwidth amplifier rather than a general-purpose 150 kHz signal-chain device. Select the external RG resistor for the required gain, then include its tolerance and temperature coefficient in the total gain-error budget. For fast common-mode or input transients, verify the input common-mode range, output settling behavior, and filtering requirements; excessive input capacitance can also affect settling and stability at higher gains.
At elevated ambient temperatures, calculate worst-case dissipation from the actual supply voltage, output voltage, load current, and quiescent current, then add it to the effect of external heat sources. Use the manufacturer's thermal characterization for the SOIC-8 footprint and actual PCB copper rather than treating the listed operating-temperature limit as a guarantee for every layout. Provide copper spreading around the package and avoid placing the amplifier directly above a hot controller or power stage.
Do not allow the differential input signal or common-mode input voltage to exceed the electrical limits, even when the output remains within its rail-to-rail range. Grounding REF to ground is appropriate only for a ground-referenced output; tying it to an inappropriate supply rail can move the output outside the sensor's usable range. Also account for input bias-current error across high source impedances and ensure that the chosen gain remains compatible with the available output swing.
コンプライアンス情報
The manufacturer product and distributor listings do not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statements for this ordering code. Compliance fields remain unknown rather than inferred from the manufacturer name or family designation.