KSZ9031MNXCA - Automotive Gigabit Ethernet PHY | Microchip
部品番号: KSZ9031MNXCA ✓ 生産中KSZ9031MNXCA 概要
An Ethernet PHY, also called a physical-layer transceiver, is the semiconductor interface between a digital Ethernet controller and physical copper wiring. It serializes and deserializes MAC-layer data, encodes it onto copper cables, recovers timing, detects link state, and negotiates the highest common speed. Within the network hierarchy, the KSZ9031 belongs to the Ethernet interface IC and physical-layer transceiver class, where it bridges a host controller such as a microcontroller, application processor, or communications processor and a 10/100/1000Base-T network.
The KSZ9031 supports all three common twisted-pair Ethernet rates, including 1000Base-T over standard category 5 unshielded twisted pair. Its auto-negotiation implementation follows Clause 28 of the IEEE 802.3 specification, allowing a link partner to select the highest mutually supported operating mode. LinkMD diagnostics add cable-length and fault-location capabilities that help industrial and automotive system integrators identify installation problems. Configurable 1.8 V, 2.5 V, and 3.3 V rails support integration with both legacy and current digital systems.
The GMII and MII interfaces provide configurable digital connectivity between the PHY and the upper-layer Ethernet controller. This flexibility allows the same physical-layer device to be used in architectures operating at different MAC-clock rates and with different parallel-data requirements. The device family is designed for automotive-qualified applications, where consistent operation, diagnostic visibility, and supply-voltage flexibility are important for long-lived embedded networks.
Typical uses include industrial Ethernet controllers, automotive head-unit or vehicle-networking platforms, communications equipment, embedded network processors, and factory automation systems. The integrated 1000Base-T capability reduces the need for separate physical-layer transceivers when a system must support 10, 100, and 1000 Mb/s links through one network port. LinkMD diagnostics are particularly useful in installations where cable routing, connector integrity, or field-service troubleshooting can be difficult.
PCB implementation should follow the manufacturer datasheet for the 48-QFN land pattern, exposed-pad connection, decoupling, and high-speed differential-routing requirements. Keep the magnetic-component interface and Ethernet traces short, preserve the specified impedance-controlled geometry, and provide the specified power and ground decoupling near the PHY. Do not substitute connector or magnetics arrangements without reviewing the reference circuit because center-tap, bias, and termination requirements vary with the network design.
This product page combines the manufacturer’s KSZ9031 family information with practical selection guidance, verified package details, interface guidance, and same-footprint ordering-code alternatives. It is intended to help engineers identify the correct automotive Ethernet PHY variant while preserving board compatibility and understanding the distinctions that require qualification review.
ドロップイン代替品: KSZ9031MNXCA — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: KSZ9031MNXCA (同一形状・フットプリント) — 相違点: Package, Product Type, Data Rate, Auto-Negotiation, Cable Type.
KSZ9031MNXIA
✅ ドロップイン価格はお問い合わせください
データシートを見る →KSZ9031MNXIC
✅ ドロップイン価格はお問い合わせください
データシートを見る →KSZ9031MNXCC
✅ ドロップイン価格はお問い合わせください
データシートを見る →KSZ9031RNXCA
✅ ドロップイン価格はお問い合わせください
データシートを見る →KSZ9031RNXIA
✅ ドロップイン価格はお問い合わせください
データシートを見る →KSZ9031RNXIC
✅ ドロップイン価格はお問い合わせください
データシートを見る →KSZ9031RNXCC
✅ ドロップイン価格はお問い合わせください
データシートを見る →KSZ9031MNXCA 仕様
| Product Type | Automotive Ethernet physical-layer transceiver |
| Ethernet Port Count | 1 port |
| Supported Ethernet Speeds | 10Base-T, 100Base-TX, and 1000Base-T |
| Maximum Nominal Ethernet Rate | 1000 Mb/s |
| Medium Support | Standard CAT-5 unshielded twisted pair |
| Host Interface | GMII and MII |
| Cable Diagnostics | LinkMD |
| Automotive Qualification | Automotive qualified |
| Supply Voltage Options | 3.3 V, 2.5 V, and 1.8 V |
| パッケージ | 48-QFN, 7x7 mm |
| 実装タイプ | Surface mount |
| Auto-Negotiation | IEEE 802.3 Clause 28 |
KSZ9031MNXCA 48-qfn, 7x7 mm ピン配置ガイド
KSZ9031MNXCA (48-qfn, 7x7 mm パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: KSZ9031MNXCA.
詳細は データシート をご参照ください。
主な用途
KSZ9031MNXCA の用途: 6 件s: Automotive Ethernet Networking, Industrial Factory Automation, Communications Equipment, Embedded Network Processor Platform, Network Equipment Cable Diagnostics, Industrial Control and Monitoring.
Automotive Ethernet Networking
The KSZ9031MNXCA fits an automotive Ethernet node that requires one physical port supporting 10Base-T, 100Base-TX, and 1000Base-T. Its automotive-qualified family status, LinkMD diagnostics, and configurable 1.8 V, 2.5 V, or 3.3 V supplies support integration with automotive-domain controllers. The PHY connects a digital host controller to the appropriate Ethernet magnetics and cable. LinkMD can help commissioning and service teams identify wiring faults. Qualification details, temperature limits, and network topology must still be confirmed for the selected ordering code.
おすすめ
Industrial Factory Automation
The KSZ9031MNXCA is suitable for a factory controller or programmable-logic node that must connect industrial equipment over copper Ethernet. One port can negotiate 10 Mb/s, 100 Mb/s, or 1000 Mb/s, while GMII and MII support broad compatibility with embedded controllers. LinkMD diagnostics improve fault isolation in long installations where cable damage or connector errors are common. The 48-QFN 7x7 mm package supports compact controller boards, although the magnetics, surge protection, and controlled-impedance layout remain essential for industrial EMC performance.
おすすめ
Communications Equipment
The KSZ9031MNXCA can provide the physical layer for communications equipment requiring a compact Gigabit Ethernet uplink. Its one-port 10/100/1000Base-T support allows common management, backplane, or service interfaces to share the PHY, while GMII and MII permit adaptation to different host-controller clocking architectures. LinkMD assists remote installation and maintenance. Designers should use the manufacturer’s recommended magnetics and reference layout because the performance of 1000Base-T depends on controlled PCB geometry, proper power decoupling, and a correctly implemented transformer interface.
おすすめ
Embedded Network Processor Platform
The KSZ9031MNXCA is appropriate for an embedded network processor, secure gateway, or service node requiring a single copper Ethernet port. A one-port PHY with three supported rates allows the platform to interoperate with legacy 10/100 Mb/s equipment while retaining a 1000 Mb/s option for throughput-oriented links. The selectable 1.8 V, 2.5 V, and 3.3 V supply configurations can simplify integration across the host’s power tree. Interface timing, reset behavior, register defaults, and clock requirements must be reviewed against the selected host controller.
おすすめ
Network Equipment Cable Diagnostics
The KSZ9031MNXCA fits diagnostic-heavy network equipment where installation faults must be identified quickly. LinkMD cable diagnostics complement the PHY’s 10Base-T, 100Base-TX, and 1000Base-T operation by providing visibility into the copper link. In a managed switch, gateway, or test appliance, this diagnostic information can be exposed through the management interface to shorten service time. The implementation should follow the KSZ9031 family diagnostics procedure and account for magnetics, termination, and cable characteristics when interpreting the results.
おすすめ
Industrial Control and Monitoring
The KSZ9031MNXCA can serve as the Ethernet interface in a PLC, data logger, sensor gateway, or remote monitoring unit. Its three-speed support improves interoperability with older 10/100 Mb/s infrastructure, while the 1000Base-T capability provides a path to faster data collection. GMII and MII interfaces allow selection according to the controller’s data rate and timing architecture. Diagnostic cable-status information can help operators distinguish physical-layer faults from higher-level network problems, and the compact 48-QFN package supports dense control hardware.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: KSZ9031MNXCA — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | KSZ9031MNXIA | KSZ9031MNXIC | KSZ9031MNXCC | KSZ9031RNXCA |
|---|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 48-QFN (7x7 mm) | 48-QFN (7x7 mm) | 48-QFN (7x7 mm) | 48-QFN (7x7 mm) | 48-QFN (7x7 mm) |
| Ethernet Port Count | 1 port | 1 port | 1 port | 1 port | 1 port |
| Supported Ethernet Speeds | 10Base-T, 100Base-TX, and 1000Base-T | 10Base-T, 100Base-TX, and 1000Base-T | 10Base-T, 100Base-TX, and 1000Base-T | 10Base-T, 100Base-TX, and 1000Base-T | 10Base-T, 100Base-TX, and 1000Base-T |
| Maximum Nominal Ethernet Rate | 1000 Mb/s | 1000 Mb/s | 1000 Mb/s | 1000 Mb/s | 1000 Mb/s |
| Host Interface | GMII and MII | GMII and MII | GMII and MII | GMII and MII | GMII and MII |
| Cable Diagnostics | LinkMD | LinkMD | LinkMD | LinkMD | LinkMD |
| Supply Voltage Options | 3.3 V, 2.5 V, and 1.8 V | 3.3 V, 2.5 V, and 1.8 V | 3.3 V, 2.5 V, and 1.8 V | 3.3 V, 2.5 V, and 1.8 V | 3.3 V, 2.5 V, and 1.8 V |
| Ordering-Code Qualification | MNXCA automotive ordering code | Different qualification-ordering code | Different qualification-ordering code | Different qualification-ordering code | RNX configuration ordering code |
主な差別化要因
- Combines three copper Ethernet rates in one physical port (vs KSZ9031RNXCA)
- Provides LinkMD diagnostics for cable troubleshooting (vs KSZ9031MNXCC)
- Supports multiple digital supply configurations (vs KSZ9031MNXIA)
- Uses the same 48-QFN 7x7 mm footprint across listed alternatives (vs KSZ9031RNXIA)
設計ノート
Follow the manufacturer’s 48-QFN land pattern and reference layout exactly, including the exposed-pad connection and component placement around the Ethernet transformer. Place the PHY and its decoupling capacitors close to the relevant supply pins, provide a low-impedance ground path, and preserve the recommended differential-pair geometry. The 1000Base-T channel is sensitive to impedance discontinuities and return-path interruptions, so substitutions in the magnetics, protection, or termination networks should be qualified as complete layout changes.
Treat the Ethernet differential pairs as controlled-impedance transmission lines rather than ordinary short traces. Use the manufacturer’s preferred pair spacing, length relationship, connector or magnetics launch geometry, and reference-plane treatment to minimize reflections and impedance discontinuities. Keep the PHY-to-magnetics path as short as practical, avoid right-angle routing, and maintain a continuous ground reference beneath the pairs. These practices are especially important at the 1000 Mb/s operating mode.
Design the 3.3 V, 2.5 V, and 1.8 V supply rails so the PHY receives clean power during link startup, reset, and high-data-rate operation. Use the values and capacitor types specified by the manufacturer, place bias or decoupling networks at their reference positions, and provide adequate source capability for the selected operating mode. Check rail sequencing and power-off behavior against the host controller so the MAC interface never sees an invalid electrical state during initialization.
Do not assume that identical QFN land patterns make two ordering codes functionally interchangeable. Before replacing the KSZ9031MNXCA with an MNX or RNX variant, compare the pin description table, exposed-pad treatment, register defaults, clock requirements, reset behavior, interface timing, qualification grade, and temperature range. In particular, an automotive qualification mark alone does not establish that every ordering code meets a specific vehicle program’s environmental or production requirements.
コンプライアンス情報
Microchip identifies the KSZ9031 family as automotive qualified. The exact ordering-code AEC-Q100 grade, RoHS status, REACH status, lead-free status, halogen-free status, and conflict-minerals declaration should be confirmed in the manufacturer’s product documentation.