LM2903PS-MAND - Dual Open-Collector Comparator | Texas Instruments
部品番号: LM2903PS-MAND ✓ 生産中LM2903PS-MAND 概要
A comparator is an analog integrated circuit that compares two input voltages and produces a logic-level result indicating which input is higher. Within the semiconductor hierarchy, a comparator belongs to the broader operational-amplifier and signal-conditioning family, with the LM2903 providing two independently usable channels in one monolithic package. This integration reduces the component count and package footprint in threshold detection, sensing, and control circuits.
The primary features of the LM2903PS-MAND are its dual-channel configuration, open-collector outputs, ground-referenced input capability, and ability to operate from either a single or split supply. Open-collector outputs are useful when the output must pull up to a system-specific voltage, interface with TTL or CMOS logic, or support wired-AND behavior. Each channel may also be used independently, allowing one device to compare two different signal pairs.
In practical signal-path terms, the comparator evaluates a voltage present at its inverting or non-inverting input against a reference or threshold established by the other input. Its wide common-mode capability allows direct sensing of low-level signals referenced to ground. Designers should account for input and output timing, pull-up requirements, supply behavior, and the transition characteristics listed in the manufacturer datasheet when setting switching thresholds or driving downstream circuitry.
Typical applications include battery threshold monitoring, sensor signal conditioning, window comparators, overvoltage detection, industrial control interfaces, and general-purpose digital decision logic. The two channels are particularly useful when a design needs two related comparisons, such as monitoring both a rising threshold and a falling threshold, or detecting upper and lower limits around a nominal operating point.
For implementation, connect an appropriate pull-up resistor to each open-collector output and account for the resulting rise time when operating speed matters. Keep input and output routing compact to reduce sensitivity to interference, and confirm the device's operating-temperature, supply-voltage, and input-voltage limits against the requirements of the target application before releasing the PCB design.
This product overview combines the device's core functionality with practical guidance on open-collector interfaces, dual-channel usage, threshold detection, and drop-in alternatives. It also provides comparison-focused engineering information intended to make component selection and PCB reuse faster than a distributor specification summary alone.
ドロップイン代替品: LM2903PS-MAND — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: LM2903PS-MAND (同一形状・フットプリント) — 相違点: Package, Supply Current, Comparator Type, Output Type, Input Bias Current.
LM2903PS
✅ ドロップイン📋 参考代替品(カタログ未掲載)
LM2903YDT
✅ ドロップイン価格はお問い合わせください
データシートを見る →LM2903DG4
✅ ドロップイン価格はお問い合わせください
データシートを見る →LM2903M
✅ ドロップイン価格はお問い合わせください
データシートを見る →LM2903BIDR
✅ ドロップイン価格はお問い合わせください
データシートを見る →LM2903PS-MAND 最大定格&電気的特性
| Comparator Type | Dual differential comparator |
| Number of Channels | 2 channels |
| Output Architecture | Open collector |
| Package Type | 8-pin small-outline package |
| ピン数 | 8 pins |
| 実装タイプ | Surface mount |
| Supply Configuration | Single supply or split supply |
| Input Common-Mode Range | Includes ground |
| Logic Interface | TTL and CMOS compatible |
LM2903PS-MAND 8-pin small-outline package ピン配置ガイド
LM2903PS-MAND (8-pin small-outline package パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: LM2903PS-MAND.
詳細は データシート をご参照ください。
主な用途
LM2903PS-MAND の用途: 6 件s: Battery Threshold Monitoring, Industrial Sensor Conditioning, Overvoltage and Undervoltage Detection, Window Comparator Control, TTL and CMOS Logic Interfacing, Embedded Control Decision Logic.
Battery Threshold Monitoring
The LM2903PS-MAND fits battery systems that need ground-referenced threshold detection because its LM2903 family supports single-supply operation and an input common-mode range that includes ground. Two independent comparator channels can monitor rising and falling thresholds without adding a second package. Each channel compares a battery-derived voltage against a reference and switches its open-collector output when the threshold is crossed. Add pull-up resistors to the required logic rail, and verify that the battery voltage, reference levels, temperature range, and fault conditions remain within the datasheet limits.
おすすめ
Industrial Sensor Conditioning
The LM2903PS-MAND is useful when a low-level sensor signal must become a logic decision close to the sensing location. Its 2 differential channels can compare a sensor-derived voltage with an adjustable upper or lower threshold, reducing the need to send weak analog information across longer board traces. The ground-inclusive common-mode range supports sensors referenced to the lower supply rail, while the open-collector output can pull up to the voltage used by the downstream industrial logic. Choose pull-up values that balance current consumption against switching speed.
おすすめ
Overvoltage and Undervoltage Detection
The LM2903PS-MAND can implement a two-channel voltage supervisor for systems that need both an upper and a lower operating limit. One comparator handles an overvoltage event while the second handles an undervoltage event, reducing discrete logic overhead. Differential inputs support a reference-versus-signal comparison, and the open-collector outputs can be pulled up to the supervisor's logic rail or combined for a common fault indication. Confirm propagation delay, input thresholds, output sink current, and the system's permissible fault response time before using the comparator as a protection device.
おすすめ
Window Comparator Control
The 2 independent channels in the LM2903PS-MAND make it a natural fit for a window comparator that detects whether a monitored voltage is below a lower limit, within an acceptable range, or above an upper limit. One channel can reference the lower threshold and the other the upper threshold, with their outputs interpreted by control logic. The differential input arrangement permits threshold comparisons around a shared reference voltage. Because the outputs are open collector, pull-ups to the chosen control voltage provide the desired active state and avoid tying the device to a fixed logic level.
おすすめ
TTL and CMOS Logic Interfacing
The LM2903PS-MAND can bridge an analog decision to TTL or CMOS logic because the LM2903 family is described as compatible with both interface families. Its open-collector output sinks current from an external pull-up resistor, allowing the output voltage to be set independently of the comparator supply. This arrangement is useful when a controller uses a different logic voltage from the analog section. Size the pull-up for the required fan-out and transition speed, and check absolute maximum input and output conditions in the manufacturer documentation.
おすすめ
Embedded Control Decision Logic
The LM2903PS-MAND can perform fast local decisions in embedded equipment where a controller should not be burdened with continuously evaluating a slowly changing analog condition. One channel can indicate that a signal has crossed a reference, while the second can monitor a complementary condition or a second sensor. The 8-pin surface-mount package supports compact layouts, and open-collector outputs permit wired fault signaling with suitable pull-ups. Ensure the comparator's timing, common-mode range, supply range, and temperature limits match the enclosure and operating environment.
おすすめ
エンジニアリング参考データ: LM2903PS-MAND — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | LM2903PS | LM2903YDT | LM2903DG | LM2903M | LM2903 |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | onsemi | 3PEAK |
| Package | 8-pin SO small-outline package | 8-pin SO small-outline package | 8-pin SO small-outline package | 8-pin SO small-outline package | 8-pin SO small-outline package | 8-pin SO small-outline package |
| Comparator Channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
主な差別化要因
- Dual independent comparator channels in one package (vs LM2903PS)
- Single-supply and split-supply operating capability (vs LM2903M)
- Ground-inclusive input common-mode operation (vs LM2903)
- Open-collector outputs for flexible logic interfacing (vs LM2903YDT)
設計ノート
Do not treat an open-collector output as a push-pull logic output. It can sink current, but it requires an external pull-up resistor to establish a high voltage. Select the pull-up voltage from the receiving logic system, verify that the comparator can sink the resulting current, and account for the resistor-capacitance rise time when the downstream circuit requires fast transitions.
Place each pull-up resistor close to the corresponding output and keep the open-collector node compact. Long traces can increase capacitance and slow the rising edge created by the pull-up. Route sensitive comparison inputs away from switching nodes, pull-up current paths, and other high-current conductors to reduce false threshold transitions and maintain predictable comparator behavior.
The two comparator channels may not be interchangeable with respect to unused-channel behavior. Review the manufacturer guidance for an unused input and output before leaving one channel unused, and do not allow an unused input to float. Confirm the permitted input and supply ranges for the actual operating temperature rather than relying only on the nominal family description.
Set reference thresholds with attention to input offset voltage and signal noise. If a slow sensor signal crosses a threshold repeatedly, add hysteresis with positive feedback around the relevant channel, while ensuring the feedback network does not disturb the intended common-mode range. Use the propagation-delay information in the datasheet when filtering or debouncing around the decision point.
コンプライアンス情報
The manufacturer family and distributor descriptions do not provide explicit compliance statements for the MAND ordering code. AEC-Q100 status is not applicable because this is a general-purpose comparator rather than an automotive-qualified ordering option.