MAX232CEAWE+T - 2/2 RS-232 Transceiver | Analog Devices
部品番号: MAX232CEAWE+T ✓ 生産中MAX232CEAWE+T 概要
An RS-232 transceiver is an interface IC that combines drivers and receivers for serial data communication. The driver converts a logic-level input into the bipolar voltage signaling used by RS-232, while the receiver converts a bipolar RS-232 input into a logic-level output. As a full-duplex 2/2 device, the MAX232CEAWE+T supports two transmit channels and two receive channels in one package.
Its principal features include two RS-232 drivers, two RS-232 receivers, operation from a +5 V supply, and operation from -40°C to +125°C. The extended temperature range makes the device suitable for industrial equipment, control systems, instrumentation, and communications equipment that must operate across a broad environmental range. The 16-SOIC package supports conventional surface-mount PCB assembly.
The MAX232 family combines a dual RS-232 driver and dual receiver with charge-pump voltage generation, allowing the interface to produce RS-232 levels from a single positive supply. Because this is an integrated transceiver, a system can use fewer discrete interface components than a design composed of separate drivers, receivers, and level-shifting circuits. Charge-pump capacitors and supply-decoupling components remain external to the IC.
Typical uses include serial service ports, industrial controllers, data-acquisition equipment, test and measurement instruments, and embedded systems that communicate with RS-232 equipment. The two-driver and two-receiver arrangement is useful for point-to-point links where both ends can transmit and receive. A transceiver does not define the serial baud rate or protocol framing; those functions are handled by the host UART and application firmware.
For PCB implementation, place the required charge-pump and bypass capacitors close to their associated pins, route the RS-232 driver outputs as impedance-controlled interfaces, and keep switching or high-current paths away from receiver inputs. Confirm the logic levels of the attached UART before connecting the transceiver because RS-232 voltage levels are not directly compatible with TTL or CMOS logic.
This product guide combines the exact MAX232CEAWE+T device information with application guidance, engineering considerations, and clearly qualified drop-in comparison options. It also organizes sourcing, datasheet, replacement, and pinout questions so engineers can evaluate the interface quickly without overlooking temperature-range, package, or supply requirements.
ドロップイン代替品: MAX232CEAWE+T — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MAX232CEAWE+T (同一形状・フットプリント) — 相違点: Package, Supply Voltage, AEC-Q100 Qualification, Data Rate, Function.
MAX232ESE+T
✅ ドロップイン価格はお問い合わせください
データシートを見る →MAX232CSE+T
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →MAX232ASE+T
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX232AESE+T
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX232ACSE+T
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →MAX232CEAWE+T 仕様
| Product Type | 2/2 full RS-232 transceiver |
| Transmitter Configuration | 2 transmitters |
| Receiver Configuration | 2 receivers |
| Interface Standard | RS-232 |
| 電源電圧 | +5 V |
| 動作温度範囲 | -40°C to +125°C |
| パッケージ | 16-SOIC |
| ピン数 | 16 pins |
| 実装タイプ | Surface mount |
| Channel Direction | Full duplex |
| Driver and Receiver Count | 2 drivers and 2 receivers |
| RoHS ステータス | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | unknown |
MAX232CEAWE+T 16-soic ピン配置ガイド
MAX232CEAWE+T (16-soic パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: MAX232CEAWE+T.
詳細は データシート をご参照ください。
主な用途
MAX232CEAWE+T の用途: 6 件s: Industrial Serial Control Interfaces, Data Acquisition Equipment, Test and Measurement Instruments, Serial Service and Configuration Ports, Networking and Communications Equipment, Embedded System Debug Interfaces.
Industrial Serial Control Interfaces
The MAX232CEAWE+T fits industrial controllers that require a compact, temperature-tolerant RS-232 interface. Its two drivers and two receivers support bidirectional point-to-point communication, while the -40°C to +125°C operating range suits equipment deployed across factory, process, and environmental-control environments. The +5 V supply and 16-SOIC package simplify integration into surface-mount control hardware. Connect the transceiver between the host UART and an external RS-232 connector, and place the manufacturer's recommended charge-pump and bypass capacitors close to their pins. Validate the UART logic levels, data rate, grounding, and protection requirements before releasing the PCB.
おすすめ
Data Acquisition Equipment
The MAX232CEAWE+T can provide a standard serial control channel between a data-acquisition instrument and a host computer. The integrated 2/2 arrangement allows the instrument to transmit commands and status while receiving configuration data over one RS-232 link. Its broad -40°C to +125°C range supports laboratory and industrial instrumentation, and the 16-SOIC package leaves more board area than larger discrete driver-receiver implementations. Use the manufacturer reference circuit for charge-pump capacitance and supply bypassing, and add the connector-level transient protection required by the installation environment.
おすすめ
Test and Measurement Instruments
For test and measurement instruments, the MAX232CEAWE+T offers a compact way to add a full-duplex RS-232 management port. Two transmitter channels can carry commands, calibration data, and results, while two receiver channels support host configuration and remote control traffic. The -40°C to +125°C range covers demanding industrial test environments, while +5 V operation simplifies power architecture. Keep sensitive analog and measurement sections separated from the RS-232 driver return currents, and verify whether the end product requires galvanic isolation, shield termination, or additional surge protection.
おすすめ
Serial Service and Configuration Ports
The MAX232CEAWE+T is well suited to service, configuration, and diagnostic ports on embedded and industrial equipment. A host can transmit setup commands and receive status messages through the two bidirectional channels, while the 16-SOIC package supports automated PCB assembly. Its extended -40°C to +125°C range allows use in equipment exposed to varied ambient conditions. The design must include the manufacturer-specified charge-pump capacitors and local supply decoupling, and the cable connector should receive ESD or surge protection appropriate to the exposed environment.
おすすめ
Networking and Communications Equipment
The MAX232CEAWE+T can be used for legacy RS-232 service channels in communications equipment where a full-duplex control link is required. Its two drivers and two receivers provide multiple serial paths without using separate driver and receiver packages, and its +5 V operation is compatible with conventional embedded logic. The -40°C to +125°C range supports industrial networking equipment. Preserve the separation between the RS-232 domain and other communications domains, observe recommended capacitor placement, and apply connector-level protection because the external cable can introduce transient voltage beyond the transceiver's operating limits.
おすすめ
Embedded System Debug Interfaces
The MAX232CEAWE+T can serve as a legacy debug or service interface on embedded control boards. Its full-duplex 2/2 arrangement allows a debugger to download commands and receive diagnostic responses through a standardized RS-232 connection. The 16-SOIC footprint is easy to route in a compact design, and operation over -40°C to +125°C supports industrial embedded products. Route driver outputs away from sensitive receiver traces, use a solid ground reference, and confirm the host UART's logic levels. External protection is particularly important when the RS-232 connector is connected to long or unprotected field cables.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MAX232CEAWE+T — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MAX232ESE+T | MAX232CSE+T | MAX232ASE+T | MAX232AESE+T | MAX232ACSE+T |
|---|---|---|---|---|---|---|
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Transceiver Configuration | 2/2 full RS-232 transceiver | 2/2 full RS-232 transceiver | 2/2 full RS-232 transceiver | 2/2 full RS-232 transceiver | 2/2 full RS-232 transceiver | 2/2 full RS-232 transceiver |
| Driver Count | 2 | 2 | 2 | 2 | 2 | 2 |
| Receiver Count | 2 | 2 | 2 | 2 | 2 | 2 |
| Supply Voltage | +5 V | +5 V | +5 V | +5 V | +5 V | +5 V |
| Surface-Mount Footprint | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Special Features | Integrated dual driver and dual receiver | Integrated dual driver and dual receiver | Integrated dual driver and dual receiver | Integrated dual driver and dual receiver | Integrated dual driver and dual receiver | Integrated dual driver and dual receiver |
主な差別化要因
- Exact +T ordering code with extended-temperature operation (vs MAX232ESE+T)
- Two transmitters and two receivers in one 16-SOIC package (vs MAX232CSE+T)
- Single-package integration reduces separate driver and receiver count (vs MC1489NE4)
設計ノート
Place the charge-pump capacitors and local supply-decoupling capacitor close to their associated MAX232 pins using the manufacturer layout and capacitance recommendations. Keep the driver output paths away from receiver inputs and sensitive analog circuitry. Route the two RS-232 channels as impedance-controlled interfaces, use a continuous ground reference, and place any connector protection close to the connector entry point.
Do not assume that the UART logic pins can directly connect to an external RS-232 connector; the MAX232 performs the required level translation. Verify input thresholds, output levels, polarity, timing, and data rate against the attached UART. Also confirm that the ordering suffix supplies the required temperature grade and that every PCB connection follows the exact pin-description diagram for the selected MPN.
Treat each RS-232 channel as a balanced, bipolar interface rather than a low-voltage single-ended signal. Terminate the cable and shield according to the connector and system grounding strategy, avoid long unprotected board traces, and use ESD or surge protection at exposed connectors. Keep ground current from external cables out of sensitive measurement paths to prevent common-mode disturbance.
The MAX232CEAWE+T is specified for -40°C to +125°C, but board temperature, copper area, airflow, and nearby heat sources must be checked against the manufacturer's maximum operating and package-temperature limits. Use the exact electrical characteristics for the selected suffix rather than assuming that every grade has identical limits across temperature.
コンプライアンス情報
Compliance declarations were not identified in the exact-part records and must be confirmed using the manufacturer's current declaration or product documentation.