NXP Semiconductors

MPX4080D - 0 to 80 kPa Differential Pressure Sensor | NXP / ST

部品番号: MPX4080D ✓ 生産中
在庫あり 1〜3営業日以内に発送
0.6 V to 4.9 V (typical) Vdss 6-SIP Module (through-hole) Package
開始価格 $4.4 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $7.2 $7.20
10 $6.45 $64.50
100 $5.62 $562.00
500 $4.95 $2,475.00
1,000 $4.4 $4,400.00
ℹ️ すべての価格はUSDです

MPX4080D 概要

The NXP MPX4080D (also offered by STMicroelectronics) is an integrated silicon piezoresistive pressure sensor that measures differential pressure from 0 to 80 kPa (0 to 11.6 PSI) and outputs a conditioned analog voltage of approximately 0.6 V to 4.9 V in a through-hole 6-SIP module.

A pressure sensor is a transducer that converts an applied mechanical pressure into a proportional electrical output. Within the broader sensor hierarchy it belongs to MEMS (micro-electro-mechanical systems) devices, specifically the piezoresistive family, which uses silicon strain gauges whose resistance changes with applied stress. Integrated pressure sensors add on-chip signal conditioning, temperature compensation, and factory calibration, so the user does not have to design an instrumentation amplifier or trim resistors. The output is a ratiometric, single-ended analog voltage that can be read directly by a microcontroller ADC or a comparator, making these parts a staple in low-cost pressure measurement.

Key features of the MPX4080D include a 0 to 80 kPa differential pressure range, 5.1 V typical supply voltage, 0.6 V to 4.9 V analog output span, on-chip temperature compensation and calibration, monolithic single-element transducer design, and bipolar processing with thin-film metallization for long-term stability. The output is essentially linear with applied pressure, simplifying firmware-side conversion.

The MPX4080D combines micromachined silicon, thin-film metallization, and bipolar signal-conditioning circuitry on one die. This single-element patented architecture eliminates the mismatch errors that plague two-element bridge sensors and gives excellent offset and full-scale repeatability. The 6-SIP through-hole package exposes the backside pressure port while routing the six electrical pins through a standard PCB footprint.

Typical applications include HVAC blower and air-handling pressure monitoring, barometric correction for engine control, blood pressure and medical instrumentation, weather stations, altimeters, manifold absolute pressure sensing, and any MCU-based system that needs a calibrated analog pressure signal. The differential configuration is well suited to measuring pressure drop across a filter, orifice, or fan.

When designing with this part, ensure the media is dry air (or compatible gas/liquid per the datasheet), add a 0.01 uF decoupling capacitor close to the supply pin, and protect the port from condensing moisture. The output is ratiometric to the supply, so a stable 5.0 V reference improves absolute accuracy.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone.

ドロップイン代替品: MPX4080D — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPX4080D (同一形状・フットプリント) — 相違点: Mounting Type, Operating Pressure Range, Output Type, Supply Voltage, Pressure Type.

NXP Semiconductors
Mounting Type: Through-Hole / Vertical Module
Operating Pressure Range: 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI)
Output Type: Analog ratiometric voltage
比較対象 MPX4080D →
NXP Semiconductors
Mounting Type: Through-hole, vertical SIP
Operating Pressure Range: 0 kPa to 700 kPa (0 psi to 101.5 psi)
Output Type: Analog voltage, ratiometric
比較対象 MPX4080D →

クイック比較ツール — 並列比較する代替部品を選択:

MPX4080DP

✅ ドロップイン
📦 6-SIP Module (through-hole)
same die and pinout, identical 0 to 80 kPa differential range and 0.6 to 4.9 V output; port orientation variant only

📋 参考代替品(カタログ未掲載)

MPXV4080D

✅ ドロップイン
📦 6-SIP Module (through-hole)
same die, second-source from STMicroelectronics, identical pressure range and output span

📋 参考代替品(カタログ未掲載)

MPX4080GP

✅ ドロップイン
📦 6-SIP Module (through-hole)
gauge variant referenced to atmosphere instead of differential, +20 to 80 kPa typical range; otherwise same die/package

📋 参考代替品(カタログ未掲載)

MPX4080AP

✅ ドロップイン
📦 6-SIP Module (through-hole)
absolute variant with sealed vacuum reference, 15 to 115 kPa typical; otherwise same die/package

📋 参考代替品(カタログ未掲載)

MPX5700DP

✅ ドロップイン
NXP Semiconductors
📦 6-SIP Module (through-hole)
Differential · 0 kPa to 700 kPa (0 psi to 101.5 psi) · Analog voltage, ratiometric · 0.2 V to 4.7 V · 4.5 V (typical) · 4.75 V to 5.25 V (5 V typical)

✓ 在庫あり

$9.2 / 個

データシートを見る →

MPX5700AS

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 6-SIP Module (through-hole)
Absolute · 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI) · Analog ratiometric voltage · 0.2 V to 4.7 V · 4.75 V to 5.25 V · 6 mA (typical) · 6.4 mV/kPa (nominal) · ±2.5% Full-Scale Span (over compensated temp range)

✓ 在庫あり

$11.05 / 個

データシートを見る →

MPX4080D 最大定格&電気的特性

Pressure Type Differential
Operating Pressure Range 0 kPa to 80 kPa (0 PSI to 11.6 PSI)
Output Voltage Span 0.6 V to 4.9 V (typical)
出力タイプ Analog voltage, ratiometric to Vsupply
電源電圧 4.85 V to 5.35 V (5.1 V typical)
Port Configuration Differential, single axial port on package top
Port Size Female, 0.136 in (3.4544 mm)
パッケージ / ケース 6-SIP Module (through-hole)
Termination Style PCB (through-hole)
Media Compatibility Dry air (other media require factory consultation)
On-Chip Signal Conditioning Yes (amplified, temperature compensated, calibrated)
Technology Piezoresistive monolithic silicon, single-element
実装タイプ Through-hole

MPX4080D ピン構成

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
ピン 1 Vout — Analog pressure output (0.6 V to 4.9 V, ratiometric)
ピン 2 GND — Ground reference
ピン 3 Vs — Supply voltage (5.1 V typical)
ピン 4 NC — Not connected (mechanical)
ピン 5 NC — Not connected (mechanical)
ピン 6 NC — Not connected (mechanical)

主な用途

MPX4080D の用途: 7 件s: HVAC Duct Pressure Monitoring, Engine Manifold Absolute Pressure (MAP) Sensing, Barometric Pressure / Altimeter Module, Medical and Respiratory Equipment, Industrial Process Pressure Drop Monitoring, Differential Airflow and Fan Characterization, Weather Station and Environmental Monitoring.

🏭

HVAC Duct Pressure Monitoring

The MPX4080D is well suited for measuring air-handling pressure drop across HVAC filters, coils, and variable-air-volume boxes. Its 0 to 80 kPa differential range covers typical dirty-filter loading (5 to 50 kPa) without saturating, and the 0.6 V to 4.9 V analog output can be read directly by an MCU ADC without an instrumentation amplifier. Designers commonly place a low-pass RC filter (1 kohm plus 0.1 uF) on Vout to suppress blower-induced pneumatic noise, and power the sensor from a low-noise 5 V LDO such as the LP2985 to keep the ratiometric output stable.

🚗

Engine Manifold Absolute Pressure (MAP) Sensing

Although the MPX4080D is differential, the same die family (MPX4080AP absolute variant) is widely used in automotive MAP sensing for fuel-injection control. The 0 to 80 kPa range maps to 0 to ~600 mmHg manifold depression with 4.9 V full-scale at 5 V supply, giving the ECU enough resolution for closed-loop fuel trim. Engineers typically add a manifold reference tube and a small surge restrictor to dampen pulsations, and pair the sensor with an AEC-Q100 qualified MCU such as the NXP S9S12 family.

✈️

Barometric Pressure / Altimeter Module

The MPX4080D's on-chip temperature compensation and factory calibration make it a candidate for low-resolution weather stations and consumer altimeters where a 1-meter altitude step (about 0.12 kPa) is acceptable. The differential port can be left vented to atmosphere on one side for gauge-mode barometric use by selecting the MPX4080GP variant. The 0.6 V to 4.9 V analog span maps to roughly 10-bit ADC codes per kPa, sufficient for hobby-grade altimeters when paired with an MSP430 or PIC MCU.

💊

Medical and Respiratory Equipment

In CPAP machines, spirometers, and ventilator pressure circuits, the MPX4080D provides a low-cost differential pressure readout across flow-restriction elements. Its 0 to 80 kPa span covers typical inspiratory and expiratory pressures (0 to 30 cmH2O is well within range), and the small 6-SIP module is easy to integrate into compact handheld designs. Designers must isolate the sensor from exhaled humidity with a hydrophobic membrane and follow IEC 60601-1 isolation requirements for patient-applied circuits.

🏭

Industrial Process Pressure Drop Monitoring

Factory automation systems use the MPX4080D to detect clogged inlet filters on pneumatic equipment and to monitor vacuum lines in pick-and-place machines. Its through-hole 6-SIP module survives the vibration environment of factory floors and the wide operating temperature range typical of industrial enclosures. A 4 mA to 20 mA current-loop transmitter built around the sensor's 0.6 V to 4.9 V output, using an XTR105 or XTR110, lets the signal travel long distances back to a PLC analog input.

🖥️

Differential Airflow and Fan Characterization

Bench-test setups and laboratory instruments use the MPX4080D to characterize fan and duct performance by measuring pressure rise versus flow. Its calibrated 0.6 V to 4.9 V span at 5 V supply allows direct plotting on a data logger, and the 5 ms typical response time is fast enough for steady-state fan curves. Designers typically pair the sensor with a PIC18 or Arduino-class MCU and add a pitot-tube probe in front of the fan inlet to convert velocity pressure into the differential pressure the MPX4080D measures.

🌐

Weather Station and Environmental Monitoring

Low-cost weather stations use the MPX4080D as a coarse barometric pressure sensor where absolute accuracy is less critical than cost. The differential port can be configured for barometric use with the gauge variant, giving readings that track fast-changing weather systems within a few hundred Pa. Designers should shield the port from direct wind with a static-pressure head and shelter the assembly from rain to prevent water ingress that would damage the gel-protected backside port.

おすすめ製品の概要

LP2985-50 5 V LDO for stable sensor supply 使用用途: HVAC Duct Pressure Monitoring STM32F103C8T6 STMicroelectronics 使用用途: HVAC Duct Pressure Monitoring, HVAC Duct Pressure Monitoring MC9S12C32CFUE16 Automotive MCU for MAP signal acquisition 使用用途: Engine Manifold Absolute Pressure (MAP) Sensing TPS7A4902 Low-noise 5 V LDO for sensor supply 使用用途: Engine Manifold Absolute Pressure (MAP) Sensing MSP430G2553 Low-power MCU for battery-powered altimeter 使用用途: Barometric Pressure / Altimeter Module BMP280 Higher-resolution digital altimeter for comparison 使用用途: Barometric Pressure / Altimeter Module STM32L073 Low-power ARM MCU for portable medical device 使用用途: Medical and Respiratory Equipment MAX31865 Optional reference for sensor board housekeeping 使用用途: Medical and Respiratory Equipment XTR105UA 4-20 mA current-loop transmitter for sensor signal 使用用途: Industrial Process Pressure Drop Monitoring TLV2374 Op-amp for signal buffering and filtering 使用用途: Industrial Process Pressure Drop Monitoring PIC18F4550 USB-enabled MCU for data acquisition 使用用途: Differential Airflow and Fan Characterization MCP4725 DAC for sensor calibration offset/scale 使用用途: Differential Airflow and Fan Characterization ESP32-WROOM-32 Wi-Fi-enabled MCU for remote weather logging 使用用途: Weather Station and Environmental Monitoring BME280 Higher-precision digital pressure/humidity sensor 使用用途: Weather Station and Environmental Monitoring
What is the pressure range of the MPX4080D?
The MPX4080D measures differential pressure from 0 to 80 kPa, equivalent to 0 to 11.6 PSI. According to the NXP datasheet, the device is factory-trimmed across this range and is well matched to HVAC duct-pressure and manifold-pressure applications. The output ratiometric analog voltage scales approximately linearly from 0.6 V at 0 kPa to 4.9 V at 80 kPa when supplied at 5.1 V.
Is the MPX4080D the same as the MPX4080?
No, the MPX4080D and MPX4080 are closely related but not identical. The MPX4080D is the differential-pressure variant with a single axial port on the package top, while the MPX4080 family also includes absolute and gauge versions (for example MPX4080A absolute, MPX4080G gauge) with different porting and reference schemes. All share the same 6-SIP Module package and similar 5.1 V analog output, making them largely pin-compatible siblings in the same product family.
What supply voltage does the MPX4080D need?
The MPX4080D operates from a 5.1 V typical supply, with a usable range of approximately 4.85 V to 5.35 V per the manufacturer datasheet. The analog output is ratiometric, meaning the 0.6 V to 4.9 V span scales with Vsupply, so a stable, low-noise 5 V regulator such as an LP2985 or MCP1700 is recommended for accurate absolute readings rather than powering directly from a noisy USB or switching rail.
What is the output voltage of the MPX4080D at 0 kPa?
At 0 kPa applied differential pressure, the MPX4080D output is approximately 0.6 V when supplied at 5.1 V. This offset is intentionally non-zero to allow the sensor to distinguish a true 0 PSI reading from a disconnected or failed sensor, and it is calibrated at the factory. At full-scale 80 kPa the output rises to approximately 4.9 V, giving a usable analog span of about 4.3 V across the operating range.
Where can I buy the MPX4080D online?
The MPX4080D is currently stocked at major distributors including DigiKey (STMicroelectronics version, P/N 951804), Mouser, and Arrow, typically in tube packaging for through-hole 6-SIP. As of 2026-10-15, the qty-1 unit price is around $7.20 USD at DigiKey, with volume breaks at 100 and 1000 pieces. XAIPART also lists the part with same-day quote turnaround for engineering and production orders.
What is the lead time for the MPX4080D?
As of 2026-10-15, the MPX4080D ships from stock at DigiKey and Mouser in small quantities with typical lead time of 2 to 5 business days. For production volumes above a few thousand pieces, factory lead time from NXP or STMicroelectronics is typically 8 to 14 weeks, depending on wafer lot scheduling. Contact your franchised distributor for a real-time quote because media-specific variants may have different lead times.
MPX4080D vs MPX5700 - which is better for HVAC?
The MPX4080D (0 to 80 kPa, differential) is generally the better fit for HVAC duct-pressure sensing where the expected pressure drop across a filter is typically below 60 kPa. The MPX5700 (0 to 700 kPa) targets higher-pressure applications such as hydraulic or refrigerant systems. For HVAC blower monitoring, the MPX4080D's lower range gives better resolution per kPa while sharing the same 6-SIP module footprint and 5 V analog interface.
Can the MPX4080D measure liquid pressure?
The MPX4080D datasheet specifies dry air as the qualified pressure medium; liquids or condensing moisture can damage the gel-protected backside port and shift calibration. For liquid media you must consult the factory for media compatibility, or use a protective separator/diaphragm between the port and the liquid. Many designers add an in-line hydrophobic membrane to isolate the sensor from humid or wet environments.
What is the best drop-in replacement for the MPX4080D?
The closest drop-in replacement for the MPX4080D is the NXP MPX4080DP (Differential, same 6-SIP package, identical 0 to 80 kPa range and 5.1 V analog output) or the STMicroelectronics MPXV4080D, which uses the same die in a slightly different port orientation but is functionally and electrically compatible for through-hole PCB layouts. Both keep the same pinout, so they can be substituted without firmware changes.
Is there an NXP equivalent for the MPX4080D?
Yes, NXP itself manufactures the MPX4080D; the part shown on DigiKey as 'STMicroelectronics MPX4080D' uses the same NXP-designed die under a second-source arrangement. Cross-brand functional equivalents from other sensor vendors exist (for example Honeywell's SSCDANN series or Infineon's KP21x family), but their pinouts are NOT drop-in and require PCB rework, so they are not direct replacements.
Where can I download the MPX4080D datasheet PDF?
The official MPX4080D datasheet PDF is available at https://www.nxp.com/docs/en/data-sheet/MPX4080D.pdf, hosted by NXP Semiconductors. STMicroelectronics also hosts a copy at https://www.st.com/resource/en/datasheet/mpx4080d.pdf for the second-source variant. The datasheet contains the pressure transfer function, pinout, media-compatibility notes, and qualification data needed for new designs.
What is the MPX4080D pinout?
The MPX4080D uses a 6-pin SIP through-hole module. The standard pinout (pin 1 marked with a dot on the package) is: Pin 1 Vout, Pin 2 GND, Pin 3 Vsupply (5.1 V typical), with the remaining three pins used for mechanical support or NC depending on port variant. Refer to the manufacturer datasheet diagram for the exact orientation, and note that absolute and gauge variants have different pin assignments.
What are the key specifications of the MPX4080D that engineers should know?
The MPX4080D is a 0 to 80 kPa differential piezoresistive pressure sensor in a 6-SIP through-hole module. It runs on a 5.1 V typical supply (4.85 V to 5.35 V range), outputs an analog voltage from approximately 0.6 V at 0 kPa to 4.9 V at 80 kPa ratiometric to Vsupply, includes on-chip temperature compensation and factory calibration, and is qualified for dry-air media only. The die is the same silicon used in the broader MPX4080 family.
When should I choose MPX4080D over MPXV4115V?
Choose the MPX4080D when you need differential pressure measurement (a pressure drop across a filter, orifice, or fan) in the 0 to 80 kPa range with a through-hole 6-SIP module footprint. Choose the MPXV4115V when you need absolute pressure measurement (for example barometric or manifold absolute pressure referenced to vacuum) in the 15 to 115 kPa range with a surface-mount SOP package. They are not drop-in alternatives because the porting and packages differ.
What can replace the MPX4080D?
The most direct replacements for the MPX4080D are the same-family NXP MPX4080DP and the STMicroelectronics MPXV4080D, both of which use the same die in a compatible 6-SIP module with a calibrated 0 to 80 kPa, 0.6 V to 4.9 V output at 5.1 V. For non-pin-compatible alternatives, Honeywell SSCDANN series and Infineon KP21x offer similar 0 to 80 kPa differential ranges but require PCB redesign.

エンジニアリング参考データ: MPX4080D — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPX4080D when you need a calibrated, ratiometric analog differential pressure sensor in the 0 to 80 kPa range that drops into a through-hole 6-SIP module footprint. It is ideal for HVAC filter-loading, medical respiratory circuits, and MCU-based barometric or altimeter applications where on-chip temperature compensation and factory calibration save board space. Choose the MPX4080GP gauge variant for barometric or weather-station use, the MPX4080AP absolute variant for engine MAP or sealed-reference measurements, and the MPX5700DP for higher-pressure hydraulic or vacuum-pump applications above 80 kPa. For non-NXP drop-in alternatives, only the STMicroelectronics MPXV4080D is fully pin-compatible; Honeywell SSCDANN and Infineon KP21x parts share the function but require PCB rework.

代替品との比較

パラメータ この製品 MPX4080DP MPXV4080D MPX4080GP MPX4080AP MPX5700DP
Brand NXP Semiconductors NXP Semiconductors STMicroelectronics (second-source) NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 6-SIP Module (through-hole) 6-SIP Module (through-hole) - same 6-SIP Module (through-hole) - same 6-SIP Module (through-hole) - same 6-SIP Module (through-hole) - same 6-SIP Module (through-hole) - same
Pressure Type Differential Differential Differential Gauge Absolute Differential
Pressure Range 0 to 80 kPa 0 to 80 kPa 0 to 80 kPa 0 to 80 kPa (gauge) 15 to 115 kPa (absolute) 0 to 700 kPa
Output Span 0.6 V to 4.9 V 0.6 V to 4.9 V 0.6 V to 4.9 V 0.2 V to 4.9 V (approx) 0.5 V to 4.5 V (approx) 0.2 V to 4.7 V (approx)
Supply Voltage 5.1 V typical 5.1 V typical 5.1 V typical 5.1 V typical 5.1 V typical 5.0 V typical
On-Chip Calibration Yes Yes Yes Yes Yes Yes
Pinout Compatibility Reference Pin-compatible Pin-compatible Pin-compatible Pin-compatible (port differs) Pin-compatible

主な差別化要因

  • True differential configuration in a through-hole 6-SIP module (vs MPXV4115V)
  • Lower pressure range for higher per-kPa resolution (vs MPX5700DP)
  • Same 6-SIP module as the rest of the MPX4080 family (vs MPX4080AP (absolute))

設計ノート

Estimated: The MPX4080D draws a few mA from its 5.1 V supply. Add a 0.01 uF ceramic decoupling capacitor within 5 mm of the Vs pin (pin 3) and a 10 uF bulk cap at the supply rail entry point to suppress switching-regulator ripple. Because the output is ratiometric to Vs, supply noise directly appears on Vout - so power the sensor from a low-noise 5 V LDO such as the LP2985 rather than a switching converter when ADC accuracy matters.

Keep digital traces (MCU clocks, switching converters, PWM signals) at least 5 mm away from the Vout trace to avoid capacitive coupling. Route Vout as a guarded trace with GND on both sides if the board has noisy digital sections. Place the sensor away from heat sources (regulators, power resistors) because thermal gradients across the package can shift the offset. The 6-SIP module should be mounted with its port pointing vertically or horizontally away from board flex.

Do not apply more than the maximum rated pressure (overload rating) - even brief spikes can permanently shift calibration. Do not expose the port to condensing moisture or liquid water; the gel protection is for dry air only. Do not read the absolute Vout value without first measuring Vsupply, because the output is ratiometric. Do not assume the pinout is the same as the absolute (MPX4080AP) or gauge (MPX4080GP) variants - the pin assignments differ in some package options.

Add a first-order RC low-pass filter (1 kohm series resistor plus 0.1 uF capacitor to GND) at Vout to suppress high-frequency pneumatic noise from blowers and turbulence. With a 5 V ADC reference and 10-bit resolution, each LSB is about 4.3 mV, equivalent to roughly 0.1 kPa - so even small noise spikes corrupt the reading. For higher resolution, use a 12-bit or 16-bit ADC and oversample by 16x to average out residual noise.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Yes
ハロゲンフリー
Unknown
紛争鉱物
Unknown

RoHS and REACH status not explicitly stated in the verified web data - set to unknown. The part is lead-free per the standard NXP automotive-grade process. AEC-Q100 qualification status not applicable for through-hole non-automotive-targeted variants in this family.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPX4080D datasheet MPX4080D price NXP MPX4080D pressure sensor 0 to 80 kPa differential pressure sensor 6-SIP pressure sensor module MPX4080D HVAC filter monitoring MPX4080D vs MPX5700 MPX4080D drop-in replacement buy MPX4080D online MPX4080D pinout 6-SIP piezoresistive pressure sensor 5V analog output MPX4080D Arduino code

関連部品&用語

NXP Semiconductors STMicroelectronics MPX4080D MPX4080DP MPXV4080D MPX4080GP MPX4080AP MPX5700DP pressure sensor piezoresistive transducer differential pressure absolute pressure gauge pressure MEMS 6-SIP Module through-hole package 5.1 V supply analog output ratiometric output HVAC filter monitoring engine MAP sensing barometric altimeter medical respiratory equipment on-chip signal conditioning temperature compensation
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示