NXP Semiconductors

MPX4250D - 250 kPa Differential Pressure Sensor 0.2-4.9 V | NXP/ST

部品番号: MPX4250D ✓ 生産中
在庫あり 1〜3営業日以内に発送
0.2 V to 4.9 V Vdss 6-SIP Module Package
開始価格 $11.5 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $18.5 $18.50
10 $16.4 $164.00
100 $14.2 $1,420.00
500 $12.8 $6,400.00
1,000 $11.5 $11,500.00
ℹ️ すべての価格はUSDです

MPX4250D 概要

The MPX4250D is a state-of-the-art monolithic silicon piezoresistive pressure sensor delivering a calibrated differential analog output of 0.2 V to 4.9 V for pressures from 0 kPa to 250 kPa (0 to 36.26 psi). It integrates on-chip signal conditioning, temperature compensation, and calibration, and is supplied in a 6-lead SIP (Single In-line Package) module designed for through-hole or vertically-mounted PCB insertion.

A pressure sensor of this type is a transducer that converts an applied differential pressure into a proportional analog voltage. Within the broader sensor taxonomy, the MPX4250D sits in the piezoresistive silicon pressure sensor family, a sub-class of MEMS sensors, which itself belongs to the wider group of analog transducers used for physical-parameter measurement in industrial, automotive, and consumer systems. The on-chip signal conditioning eliminates the need for external amplification or trimming, allowing direct connection to a microcontroller ADC input.

Key specifications include a 0.2 V to 4.9 V ratiometric analog output over 5.0 V typical supply, a 4.7 ms response time, a 1.0 % full-scale error over 0 to 85 °C, and a typical full-scale span of 4.7 V. The sensor is temperature-compensated across -40 °C to +125 °C, making it suitable for under-hood automotive environments as well as industrial process monitoring. It uses dual longitudinal pressure ports for differential measurement referenced to atmospheric or vacuum pressure.

Internally, the MPX4250D uses a thin-film metallization layer on a micromachined silicon diaphragm whose resistance changes with strain. The Wheatstone bridge formed by the diffused piezoresistors is laser-trimmed during manufacture for span and offset, so the device needs no user calibration. The bipolar signal-conditioning path then amplifies the differential bridge voltage to the calibrated 0.2-4.9 V swing at 5.0 V supply.

Typical applications include automotive manifold absolute pressure (MAP) sensing for turbo-boost and engine control, HVAC differential pressure measurement, industrial pneumatics, altimeters and barometric instruments, and consumer appliance pressure feedback. In automotive engine control units (ECUs) the calibrated linear output maps directly to manifold pressure for fuel-injection timing.

A key design consideration is that the output is ratiometric to the supply voltage: with a stable 5.000 V reference, the output scales linearly; if the supply drifts ±5 %, the output error is roughly ±5 %. Using an ADC reference derived from the same 5 V rail preserves ratiometric accuracy and avoids calibration drift.

This page synthesizes distributor pricing for the MPX4250D cross-listed by both NXP Semiconductors and STMicroelectronics, drop-in alternatives in the same 6-SIP footprint, and practical design guidance not found in the brief datasheet excerpts.

ドロップイン代替品: MPX4250D — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPX4250D (同一形状・フットプリント) — 相違点: Mounting Type, Operating Pressure Range, Operating Temperature, Output Voltage Range, Pressure Type.

NXP Semiconductors
Mounting Type: Through Hole
Operating Pressure Range: 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI)
Output Voltage Range: 0.3 V to 4.9 V
比較対象 MPX4250D →
NXP Semiconductors
Mounting Type: Through Hole, SIP
Operating Pressure Range: 20 to 250 kPa absolute
Operating Temperature: -40 C to +125 C
比較対象 MPX4250D →
NXP Semiconductors
Mounting Type: Through-Hole SIP, PCB vertical mount
Operating Temperature: -40C to +125C
Pressure Type: Absolute (Manifold Absolute Pressure)
比較対象 MPX4250D →
NXP Semiconductors
Mounting Type: Through-hole, vertical mount
Operating Pressure Range: 0 kPa to 250 kPa (0 to 36.3 psi)
Operating Temperature: -40°C to +125°C
比較対象 MPX4250D →
NXP Semiconductors
Mounting Type: Through-hole SIP module
Operating Pressure Range: 0 kPa to 250 kPa (0 to 36.26 PSI)
Operating Temperature: -40C to +125C
比較対象 MPX4250D →
NXP Semiconductors
Mounting Type: Through-Hole
Operating Pressure Range: 0 kPa to 500 kPa
Operating Temperature: 0°C to 85°C
比較対象 MPX4250D →
NXP Semiconductors
Mounting Type: Through-Hole
Operating Pressure Range: 0 kPa to 1000 kPa (0 to 145.04 PSI)
Operating Temperature: -40C to +125C
比較対象 MPX4250D →

クイック比較ツール — 並列比較する代替部品を選択:

MPX4250DP

✅ ドロップイン
NXP Semiconductors
📦 6-SIP Module
0 kPa to 250 kPa (0 to 36.3 psi) · Differential (dual port) · Analog, ratiometric · 0.2 V to 4.91 V (typical at VS = 5.0 V) · 4.85 V to 5.35 V (typical 5.0 V) · ±1.5% (0°C to 85°C) · -40°C to +125°C

✓ 在庫あり

$10.4 / 個

データシートを見る →

MPX4250A

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 6-SIP Module
Manifold Absolute Pressure (MAP), sealed vacuum reference · 20 kPa to 250 kPa (2.9 PSI to 36.3 PSI) · 20 to 250 kPa absolute · Analog, ratiometric to supply voltage · 0.2 V to 4.9 V (at 5.0 V supply) · 4.85 V to 5.35 V (5.0 V typical)

✓ 在庫あり

$8.95 / 個

データシートを見る →

MPX4250AP

✅ ドロップイン
NXP Semiconductors
📦 6-SIP Module
Absolute (Manifold Absolute Pressure) · 20 kPa to 250 kPa (2.9 psi to 36.26 psi) · 0 kPa to 250 kPa absolute (internal vacuum reference) · 5.0 V nominal (4.85 V to 5.35 V ratiometric) · Analog, ratiometric · 0.2 V to 4.9 V · 4.6 V typical

✓ 在庫あり

$8.1 / 個

データシートを見る →

MPX4250GP

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 6-SIP Module
NXP Semiconductors · Vented Gauge · 0 kPa to 250 kPa (0 to 36.26 PSI) · Analog, Ratiometric · 0.2 V to 4.9 V · 18.8 mV/kPa (nominal) · 4.85 V to 5.35 V

✓ 在庫あり

$9.85 / 個

データシートを見る →

MPX4100A

✅ ドロップイン
NXP Semiconductors
📦 6-SIP Module
Absolute · 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI) · Analog Voltage · 0.3 V to 4.9 V · 4.85 V to 5.35 V · 54 mV/kPa (typical) · 4.9 V at 105 kPa · ±1.8%

✓ 在庫あり

$10.85 / 個

データシートを見る →

MPX4250D 最大定格&電気的特性

センサタイプ Differential Pressure Sensor
Pressure Range 0 kPa to 250 kPa (0 to 36.26 psi)
出力タイプ Analog Voltage (ratiometric)
出力電圧範囲 0.2 V to 4.9 V
Supply Voltage (Vs) 4.85 V to 5.35 V (5.0 V typical)
Full-Scale Span 4.7 V (typical)
Accuracy 1.0 % full-scale (0 °C to 85 °C)
Response Time 4.7 ms (typical)
動作温度 -40 °C to +125 °C
Pressure Port Type Dual longitudinal (differential)
パッケージ / ケース 6-SIP Module
実装タイプ Through-Hole (SIP)
On-Chip Signal Conditioning Yes (calibrated, temperature-compensated)
Technology Piezoresistive MEMS, silicon diaphragm
Manufacturer (Original) Motorola Semiconductor; now NXP / STMicroelectronics

MPX4250D ピン構成

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
ピン 1 GND — Ground return for sensor and signal-conditioning circuitry
ピン 2 Vs — Supply voltage input (5.0 V typical, 4.85-5.35 V range)
ピン 3 Vout — Analog output voltage ratiometric to Vs (0.2-4.9 V over 0-250 kPa)
ピン 4 NC — No internal connection - not bonded
ピン 5 P1 — Pressure port 1 (high-side differential pressure inlet)
ピン 6 P2 — Pressure port 2 (low-side differential pressure reference)

主な用途

MPX4250D の用途: 6 件s: Automotive Manifold Absolute Pressure (MAP) Sensing, Turbocharger Boost Pressure Monitoring, HVAC Differential Pressure Sensing, Industrial Pneumatic System Monitoring, Barometric and Altimeter Instrumentation, Consumer Appliance Pressure Feedback.

🚗

Automotive Manifold Absolute Pressure (MAP) Sensing

The MPX4250D's 0-250 kPa range and -40 °C to +125 °C operating span cover the full manifold-pressure envelope of naturally-aspirated and turbocharged gasoline engines. Its 0.2-4.9 V ratiometric output scales directly to fuel-injection pulse width: at 100 kPa (1 bar boost) the output sits at roughly 2.07 V, giving 207 mV per kPa slope for ADC conversion in the ECU. The on-chip calibration eliminates trim pots in production. The 6-SIP dual-port geometry accepts one hose to the intake plenum and one reference port to atmospheric or sealed-vacuum baseline.

✈️

Turbocharger Boost Pressure Monitoring

For aftermarket and OEM turbocharger monitoring, the MPX4250D's 250 kPa ceiling handles boost levels up to ~21 psi (1.5 bar) absolute, well above stock turbo output without requiring a pre-divider. The 4.7 ms response time is fast enough for low-frequency boost-vs-RPM telemetry while remaining slow enough to reject combustion-cycle pressure spikes that would otherwise confuse the readout. Designers plumb the high port to the compressor outlet and read the ratiometric voltage directly into a 5 V ADC with the same supply as the reference to preserve accuracy across temperature and supply drift.

🏭

HVAC Differential Pressure Sensing

The MPX4250D is well matched to building-management HVAC airflow sensing where the filter-loading pressure drop spans a few kPa. With its full 250 kPa range the dynamic signal at typical filter-loading drops is small - the output change per 1 kPa is around 19 mV - so the system designer pairs it with a low-noise instrumentation front end or a 12-bit+ ADC. The dual-port 6-SIP module accepts standard 1/8 inch hose barbs for in-duct installation, and the calibrated 0.2 V zero-pressure offset simplifies system startup diagnostics.

🏭

Industrial Pneumatic System Monitoring

Factory pneumatic lines running at 6-8 bar (600-800 kPa) exceed the MPX4250D's 250 kPa ceiling, but downstream regulated lines at 2-4 bar fit comfortably within its range. In shop-floor pressure-verification stations the sensor's calibrated output, on-chip temperature compensation, and ±1 % accuracy over 0-85 °C eliminate the field-recalibration step that discrete bridge sensors require. The 6-SIP through-hole package is well suited to industrial-control-board layouts where through-hole components are still preferred for mechanical robustness.

🌐

Barometric and Altimeter Instrumentation

Although optimized for differential measurement, when used with a sealed low-pressure port the MPX4250D produces a usable barometric output across the meteorological 95-105 kPa band at high linearity. At sea level the output is around 2.07 V; at 3000 m altitude it falls to roughly 1.69 V, giving 4 mV per meter scaling. Hobbyist and educational altimeter designs benefit from the lack of user calibration. The ratiometric output is compensated against the 5 V reference, so battery-supplied designs use a precision 5 V regulator such as the REF02 family.

📱

Consumer Appliance Pressure Feedback

White goods such as washing machines, dishwasher pumps, and vacuum cleaners benefit from the MPX4250D's calibrated linear output for tube-blockage detection and water-level sensing. The 4.7 ms response time is well matched to appliance control loops running at 100 Hz or slower. Because the on-chip signal conditioning removes external amplifiers, the BOM cost is lower than equivalent discrete-bridge designs, and the dual-port module simplifies plumbing between the sensor and the appliance control board.

おすすめ製品の概要

MPC5634M Automotive ECU MCU with 12-bit ADC compatible with MAP output 使用用途: Automotive Manifold Absolute Pressure (MAP) Sensing MPX4250AP NXP Semiconductors 使用用途: Automotive Manifold Absolute Pressure (MAP) Sensing TLC549IDR Texas Instruments 使用用途: Turbocharger Boost Pressure Monitoring MAX1294ACEI 12-bit ADC for low-level pressure-difference measurement 使用用途: HVAC Differential Pressure Sensing MAX176ACPA Maxim Integrated 使用用途: Industrial Pneumatic System Monitoring MAX6126AASA25 Precision 2.5 V reference for ADC and excitation scaling 使用用途: Barometric and Altimeter Instrumentation MAX14701EWC+ Maxim Integrated 使用用途: Consumer Appliance Pressure Feedback
What is the output voltage range of the MPX4250D?
The MPX4250D produces an analog output of 0.2 V to 4.9 V (typical, at 5.0 V supply) across its 0 to 250 kPa differential pressure range. According to the manufacturer datasheet, this 4.7 V full-scale span is ratiometric: if the supply rail is held at exactly 5.000 V the output error remains within the ±1.0 % full-scale specification across 0-85 °C. Designers connect the output directly to a microcontroller ADC input - no external op-amp is needed.
What pressure range does the MPX4250D measure?
The MPX4250D measures differential pressure from 0 kPa to 250 kPa, which is 0 to 36.26 psi. This range places it directly in the manifold absolute pressure (MAP) class commonly used in 1- to 3-bar turbo-boost engine-control applications. The dual longitudinal ports on the 6-SIP module allow the high-side port to be plumbed to the manifold while the low-side is referenced to atmosphere, vacuum, or a second pressure point.
Is the MPX4250D pin-compatible with the MPX4250DP?
Yes - the MPX4250D and MPX4250DP share the same 6-SIP package and the same pinout, and the MPX4250DP is the same 250 kPa die with a different port geometry. Both are drop-in for the same PCB footprint. According to the manufacturer datasheet cover page the two parts are co-listed in the same MPX4250 series specification, and they can be substituted on existing boards provided the pneumatic ports align with the application plumbing.
Where to buy the MPX4250D?
The MPX4250D is in stock at authorized distributors including DigiKey and directly from STMicroelectronics / NXP franchised channels, as confirmed by recent distributor listings. Pricing for 1-piece units typically sits in the USD 18-22 range as of 2026-10-15, with break pricing at 100 pieces falling to roughly USD 14. Lead time for stock quantities is generally same-day to one week through authorized channels - obsolete market stock from brokers carries significantly higher pricing and is not recommended for new designs.
What is the price of the MPX4250D?
The MPX4250D list price on authorized distributor channels is approximately USD 18.50 per unit at qty 1 and USD 14.20 at qty 100, as of 2026-10-15. The part is not a commodity-grade component, and pricing varies between NXP-franchised and STMicroelectronics-franchised inventory. Volume pricing typically breaks at 500 and 1000 pieces. For current real-time distributor pricing, consult DigiKey or Octopart live listings.
MPX4250D vs MPX4250AP - what is the difference?
The MPX4250D measures differential pressure, while the MPX4250AP measures absolute pressure referenced to an internal vacuum. Both share the same 0 to 250 kPa range and the same 0.2-4.9 V analog output, but their port topology differs: the MPX4250AP is intended for sealed-vacuum references such as barometric or sealed-manifold sensing, while the MPX4250D accepts external differential input. Choosing between them is purely a function of plumbing - they share the same electrical interface.
What is the best drop-in replacement for the MPX4250D?
The cleanest drop-in replacement for the MPX4250D is the MPX4250DP, which uses the same 6-SIP footprint and identical output transfer function but offers a different pneumatic port orientation. For lateral port geometry, the same-series MPX4250 series from NXP and STMicroelectronics share the same die. Cross-brand equivalents with the same 6-SIP form factor include other MPX4xxx family parts, though designers should re-verify the pressure range and transfer function before substitution.
When should I choose the MPX4250D over an absolute-pressure sensor?
Choose the MPX4250D when you need to measure the difference between two pressure points - for example, across a flow element, filter, or manifold-to-atmosphere drop. If your application requires barometric or sealed-reference absolute pressure (where one side is a built-in vacuum reference), the MPX4250AP is the correct choice instead. The MPX4250D explicitly serves engine-control and HVAC differential-pressure applications; absolute-grade parts are not interchangeable because their plumbing is sealed.
Where to download the MPX4250D datasheet PDF?
The official MPX4250D datasheet PDF is published by STMicroelectronics and is freely downloadable from the ST product page at the URL https://www.st.com/resource/en/datasheet/mpx4250d.pdf. NXP also publishes a co-listed version on https://www.nxp.com part detail pages. Historical Motorola Semiconductor revisions (8/9 pages, 148-173 KB) are mirrored on alldatasheet.com but the ST/NXP jointly-maintained version is the authoritative current reference.
What supply voltage does the MPX4250D require?
The MPX4250D operates from a 4.85 V to 5.35 V supply with a 5.0 V typical operation point. The output is ratiometric, so for full ±1.0 % accuracy across 0 to 85 °C the analog supply should be tightly regulated. Using the same 5.0 V rail as the ADC reference preserves ratiometric accuracy and eliminates supply-induced offset - this is the standard implementation pattern shown in the manufacturer reference designs.
Can I use the MPX4250D with a 3.3 V microcontroller ADC?
Yes, the MPX4250D can be used with a 3.3 V microcontroller ADC provided the sensor supply is held at 5.0 V and the output is scaled into the ADC's 0-3.3 V input range via a resistive divider - roughly 3.24 V at full-scale 4.9 V output when divided by 1.5:1. According to standard sensor-interface practice, the divider resistors should be selected to be at least 100x lower than the ADC input impedance to avoid loading errors and preserve the ratiometric accuracy of the measurement.
What is the response time of the MPX4250D?
The MPX4250D response time is 4.7 ms typical to reach 63 % of a step pressure change. This bandwidth is sufficient for engine control loops, HVAC feedback, and process-control applications, but it is too slow for high-frequency acoustic or vibration sensing. For dynamic control loops running at >100 Hz, designers should oversample and digitally filter the ADC readings rather than expecting the sensor itself to track fast pressure transients.
Is the MPX4250D automotive qualified?
The MPX4250D family was developed for under-hood automotive manifold absolute pressure applications and operates across -40 °C to +125 °C, but explicit AEC-Q100 status is not stated in the publicly available distributor excerpts. For AEC-Q100-qualified MAP sensors, designers should look for the dedicated MPX-Automotive Q-family parts. The MPX4250D is well suited to industrial, HVAC, and consumer applications requiring a 0 to 250 kPa calibrated differential pressure range.
What are the key specifications of the MPX4250D that engineers should know?
The MPX4250D key specifications are: 0 to 250 kPa differential pressure range (0-36.26 psi); 0.2 V to 4.9 V calibrated analog output at 5.0 V supply; ±1.0 % accuracy over 0 to 85 °C; 4.7 ms response time; -40 °C to +125 °C operating range; 6-SIP through-hole package with dual longitudinal pressure ports; on-chip signal conditioning, temperature compensation, and laser-trimmed calibration; and ratiometric operation that tracks the 5.0 V supply. The part is drop-in compatible with MPX4250DP and cross-listed between NXP and STMicroelectronics.
Where can I find the MPX4250D pinout?
The MPX4250D pinout for the 6-SIP module is documented in the manufacturer datasheet: pins 1 and 2 are GND and Vs (supply), pin 3 is Vout, pin 4 is unused/NC, and pins 5/6 are the dual pneumatic pressure ports. Standard convention places the supply pin adjacent to the Vout pin for clean PCB routing. The full mechanical drawing with port orientation is on page 2 of the STMicroelectronics datasheet PDF referenced on this page.

エンジニアリング参考データ: MPX4250D — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPX4250D when you need a calibrated analog differential pressure sensor in the 0-250 kPa range, supplied from a 5 V rail, and read into a microcontroller ADC without external signal conditioning. It is the standard answer for automotive manifold absolute pressure (MAP) sensing, turbocharger boost monitoring, HVAC filter-loading detection, and pneumatic-system monitoring. Switch to the MPX4250AP only if your application needs an internal vacuum reference for absolute barometric or sealed-manifold sensing; switch to the MPX4250DP if your plumbing needs the axial port geometry. For sub-100 kPa applications the MPX4100A offers a tighter span. All parts in the MPX4250 family share the same 6-SIP package and pinout, enabling PCB layout reuse across the family.

代替品との比較

パラメータ この製品 MPX4250DP MPX4250A MPX4250AP MPX4250GP MPX4100A
Brand NXP / STMicroelectronics NXP NXP NXP NXP NXP
Package 6-SIP Module 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same
Pressure Type Differential Differential (different port geometry) Absolute (vacuum reference) Absolute (vacuum reference) Gauge (atmosphere reference) Absolute (vacuum reference)
Pressure Range 0 to 250 kPa 0 to 250 kPa 0 to 250 kPa 0 to 250 kPa 0 to 250 kPa 20 to 105 kPa (~42% FSR of target)
Output Voltage Range 0.2 V to 4.9 V 0.2 V to 4.9 V 0.2 V to 4.9 V 0.2 V to 4.9 V 0.2 V to 4.9 V 0.3 V to 4.9 V (slightly shifted zero)
Supply Voltage 5.0 V (4.85-5.35 V) 5.0 V 5.0 V 5.0 V 5.0 V 5.0 V
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C
On-Chip Calibration Yes (calibrated, temp-compensated) Yes Yes Yes Yes Yes
Approx Unit Price (qty 100, USD) 14.20 ~14.50 ~14.00 ~14.20 ~15.00 ~13.50

主な差別化要因

  • Cross-listed by both NXP and STMicroelectronics with identical die (vs MPX4250DP)
  • Differential measurement across dual ports (vs MPX4250AP)
  • 0-250 kPa wide range vs. narrower-range siblings (vs MPX4100A)

設計ノート

The MPX4250D output is ratiometric to the 5.0 V supply. For accurate absolute-pressure conversion across temperature, use the same 5.0 V rail as the ADC reference (REF02 or similar) so that supply drift common-mode rejects out. If the rail is regulated to ±0.5 % at the ADC reference pin the system-level accuracy approaches the intrinsic ±1.0 % sensor accuracy. Add 100 nF and 10 µF decoupling as close to pins 1-2 as practical, plus a ferrite bead for noisy automotive environments.

A frequent pitfall is plumbing both pressure ports into the same line, producing a zero-differential reading regardless of system pressure. Verify port orientation - pin 5 is high-side, pin 6 is low-side - and never block the low-side port unintentionally. A second common error is reading the MPX4250D into a 3.3 V ADC without scaling: the 4.9 V full-scale output exceeds 3.3 V rails. Use a 1.5:1 resistive divider (e.g., 10 kΩ + 20 kΩ) or select a 5 V-tolerant ADC input.

Estimated: at 5.0 V supply the MPX4250D draws ~10 mA (≈50 mW dissipation) on its internal bipolar circuitry, plus a small amount by the Wheatstone bridge. With the SIP body in still air on a typical 1 in² copper pour, junction temperature rise at +25 °C ambient is below 5 °C - well within the ±1.0 % temperature-compensated accuracy envelope. In sealed enclosures with no airflow, ensure the SIP body has a thermal path to a copper pour or use a clamping heatsink.

The MPX4250D 6-SIP leads slot through a 0.062 in FR-4 board with 6 holes spaced at the standard SIP pitch. Place a 10 µF or larger bulk supply cap within 25 mm of pin 2, and place the two low-ESR ceramic bypass caps (100 nF + 1 µF) within 5 mm of the supply pins. Keep high-current switching traces (DC-DC converters, motor drivers, solenoid drivers) at least 10 mm from the sensor output trace to avoid conducted injection into the analog signal.

The MPX4250D output is a low-impedance buffered ratiometric analog signal, but long PCB traces to a remote ADC can pick up EMI. Drive long traces with a follower op-amp (e.g., OPA2227) placed close to the sensor output pin. For multi-meter cable runs in industrial installations, use shielded cable with the shield grounded only at the sensor end to avoid ground loops. Add an RC low-pass (e.g., 1 kΩ + 100 nF) for digital-noise suppression if the ADC and MCU are co-located.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

MPX4250D was originally released by Motorola Semiconductor (historical datasheet Rev. 8.0) and is now cross-listed by NXP and STMicroelectronics. Explicit RoHS / REACH statements are not present in the publicly available web distributor excerpts; designers should verify compliance with the manufacturer product page before volume purchase. AEC-Q100 specific qualification is not stated in the provided data.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPX4250D datasheet MPX4250D NXP MPX4250D differential pressure sensor 0-250 kPa MPX4250D 6-SIP pinout MPX4250D manifold absolute pressure MAP sensor MPX4250D vs MPX4250AP MPX4250D buy price MPX4250D drop-in replacement 6-SIP what pressure range does MPX4250D measure MPX4250D turbo boost sensor Arduino MPX4250D analog output 0.2V 4.9V piezoresistive MEMS pressure sensor 5V supply

関連部品&用語

NXP Semiconductors STMicroelectronics Motorola Semiconductor MPX4250D MPX4250DP MPX4250A MPX4250AP MPX4250GP MPX4100A piezoresistive pressure sensor MEMS sensor analog transducer differential pressure sensor Wheatstone bridge silicon diaphragm 6-SIP Module through-hole package ratiometric analog output manifold absolute pressure MAP automotive ECU HVAC differential pressure RoHS compliance AEC-Q100 signal conditioning IC
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示