NXP Semiconductors

MPX5010DP - 10kPa Differential Pressure Sensor, 5V | NXP/ST

部品番号: MPX5010DP ✓ 生産中
在庫あり 1〜3営業日以内に発送
0.2 V to 4.7 V Vdss 6-SIP Module Package
開始価格 $9.6 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $18.5 $18.50
10 $16.4 $164.00
100 $13.2 $1,320.00
500 $11.05 $5,525.00
1,000 $9.6 $9,600.00
ℹ️ すべての価格はUSDです

MPX5010DP 概要

The NXP MPX5010DP is an integrated silicon piezoresistive pressure sensor delivering a precise differential pressure measurement from 0 to 10 kPa (0 to 1.45 PSI) with on-chip signal conditioning, temperature compensation and calibration, housed in a 6-lead SIP module with dual 4.93 mm pressure ports.

A piezoresistive pressure transducer is a solid-state sensor that converts applied gas or air pressure into a strain-induced change in resistance, which is then conditioned on-chip into a ratiometric analog output voltage proportional to pressure. The MPX5010DP belongs to the MPxx5010 family of monolithic silicon pressure sensors, situated in the broader hierarchy: pressure sensor -> MEMS sensor -> transducer -> sensor IC -> semiconductor. It is intended for systems employing a microcontroller or microprocessor with an A/D converter, where it replaces discrete bridge amplifiers and trimming circuits with a single calibrated device.

Key specifications include a full-scale span of 10 kPa, a sensitivity of 450 mV/kPa typical, an output range of 0.2 V to 4.7 V at 5 V supply, and a 5 V typical supply voltage (4.75 V to 5.25 V). The integrated bipolar signal chain delivers better than +/-1.5% linearity over the compensated temperature range of 0 to 85 C, while factory calibration removes the need for external passive trim networks. The dual-port (DP) mechanical configuration supports differential measurement between two air or non-corrosive gas sources.

Architecturally, the device combines a micromachined silicon diaphragm with thin-film metallization and bipolar signal processing on a single die. This monolithic integration is what enables its calibrated, temperature-compensated output without external components. The 6-SIP package provides two axial ports for differential pressure connection and four through-hole leads for power, ground, and analog output, simplifying PCB assembly.

Typical applications include HVAC variable-air-volume controllers, medical respiratory and CPAP monitors, industrial process control, water-level / liquid-level sensing via trapped air columns, altitude and barometric measurement, and consumer appliance pressure feedback. The differential topology is particularly suited to measuring pressure drop across filters, ducts, orifices, and small fans.

When designing with the MPX5010DP, decouple the supply with a 100 nF ceramic capacitor placed within 5 mm of the VCC pin and provide a stable 5 V rail, since the output is ratiometric. Keep both pressure ports free of moisture, particulates, and corrosive media; for liquid sensing, isolate the sensor via an air column or use the MPVZ5010 family with media-resistant gel.

This page synthesizes distributor pricing, drop-in alternatives within the MPxx5010 family, and practical design notes not collected in any single manufacturer datasheet.

ドロップイン代替品: MPX5010DP — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPX5010DP (同一形状・フットプリント) — 相違点: Mounting Type, Operating Temperature, Supply Voltage, Output Type, Package.

NXP Semiconductors
Mounting Type: Through Hole
Operating Temperature: -40 C to +125 C (per NXP MPX2102 series datasheet)
Supply Voltage: 10 V typical
比較対象 MPX5010DP →
NXP Semiconductors
Mounting Type: Through-hole module
Operating Temperature: 0C to +85C (industrial-grade derivative supported to 40C to +125C)
Supply Voltage: 4.75 V to 5.25 V
比較対象 MPX5010DP →
NXP Semiconductors
Mounting Type: Through-Hole
Supply Voltage: 4.75 V to 5.25 V (typical 5 V)
Package: 6-SIP module (Unibody)
比較対象 MPX5010DP →
NXP Semiconductors
Mounting Type: Through-hole, axial tube
Package: 6-SIP Module, Case 867E-03
比較対象 MPX5010DP →
NXP Semiconductors
Mounting Type: Through Hole
Operating Temperature: 0 C to 85 C
Output Type: Analog Voltage
比較対象 MPX5010DP →
NXP Semiconductors
Mounting Type: Through-Hole (with dual pressure ports)
Operating Temperature: -40C to +125C
Supply Voltage: 5.0 V nominal (4.75 V to 5.25 V)
比較対象 MPX5010DP →
STMicroelectronics
Operating Temperature: -40C to +125C (per ST datasheet family)
Supply Voltage: 5 V (typical)
Output Type: Analog Voltage
比較対象 MPX5010DP →
NXP Semiconductors
Mounting Type: Surface Mount
Operating Temperature: -40 C to +125 C
Output Type: Analog Millivolt (Wheatstone bridge)
比較対象 MPX5010DP →
NXP Semiconductors
Mounting Type: Surface Mount
Operating Temperature: -40 C to +125 C
Supply Voltage: 5 V nominal (4.75 V to 5.25 V)
比較対象 MPX5010DP →

クイック比較ツール — 並列比較する代替部品を選択:

MPXV5010G

✅ ドロップイン
📦 6-SIP Module
Single-port gauge topology vs DP dual-port differential; pinout matches 6-SIP body

📋 参考代替品(カタログ未掲載)

MPX5010GP

✅ ドロップイン
NXP Semiconductors
📦 6-SIP Module
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 4.75 V to 5.25 V (typical 5 V) · Analog, ratiometric · 0.2 V to 4.7 V · 4.5 V (typical)

✓ 在庫あり

$10.85 / 個

データシートを見る →

MP3V5010

✅ ドロップイン
📦 6-SIP Module
3 V supply (vs 5 V) - output scales to 0.2-2.45 V; same 0-10 kPa differential range

📋 参考代替品(カタログ未掲載)

MPX5050DP

✅ ドロップイン
NXP Semiconductors
📦 6-SIP Module
NXP Semiconductors · Differential Pressure Sensor · Piezoresistive (MEMS silicon) · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · Differential, dual tube port (Male, 0.19" / 4.93 mm Tube) · Analog ratiometric voltage · 0.2 V to 4.7 V · 4.5 V typical

✓ 在庫あり

$8.65 / 個

データシートを見る →

XGZP6895A

✅ ドロップイン
📦 6-SIP Module (MPX5010DP compatible)
Cross-brand CFSensor drop-in; -100 to 700 kPa programmable range vs 0-10 kPa fixed; optional 5 V or 3.3 V supply; same pinout for default config

📋 参考代替品(カタログ未掲載)

MPX5010DP 最大定格&電気的特性

Pressure Type Differential
Operating Pressure Range 0 kPa to 10 kPa (0 to 1.45 PSI)
Sensitivity 450 mV/kPa (typical)
出力電圧範囲 0.2 V to 4.7 V
電源電圧 4.75 V to 5.25 V (5 V typical)
Linearity ±1.5% VFSS (typical, 0-85 C)
動作温度 0 C to +85 C (compensated)
Port Configuration Dual axial ports, 4.93 mm (0.19 in) tube
パッケージ 6-SIP Module
出力タイプ Analog, ratiometric
実装タイプ Through-hole (SIP)
Technology Piezoresistive, monolithic silicon, on-chip signal conditioned
RoHS ステータス Compliant

MPX5010DP ピン構成

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
ピン 1 VCC — 5 V supply voltage (4.75 V to 5.25 V)
ピン 2 VOUT — Analog ratiometric output, 0.2 V to 4.7 V
ピン 3 GND — Ground reference
ピン 4 NC — Not connected (per datasheet)
ピン 5 NC — Not connected (per datasheet)
ピン 6 NC — Not connected (per datasheet)

主な用途

MPX5010DP の用途: 7 件s: HVAC Variable Air Volume (VAV) Control, Medical Respiratory / CPAP Monitoring, Filter / Orifice Pressure Monitoring, Water Level Sensing via Air Column, Industrial Process Air Flow Measurement, Barometric / Altitude Estimation, Small Fan / Blower Health Monitoring.

🏭

HVAC Variable Air Volume (VAV) Control

The MPX5010DP is well suited to HVAC VAV box control because its 0-10 kPa differential range matches the typical static pressure setpoint of duct-mounted flow sensors, and its 450 mV/kPa sensitivity provides 4.5 V of useful span on a 5 V rail - enough to resolve airflow setpoint changes of better than 0.05 kPa after a 10-bit ADC. Placed across a Pitot tube or orifice plate, the differential reading feeds a microcontroller that modulates a damper actuator. Unlike gauge-only sensors, the DP topology compensates for ambient barometric drift in rooftop installations.

💊

Medical Respiratory / CPAP Monitoring

For CPAP machines and respiratory flow circuits, the MPX5010DP's differential topology allows direct measurement of pressure drop across a flow restriction or patient circuit, with the 0.2-4.7 V analog output simplifying interface to a medical-grade MCU ADC. The 450 mV/kPa sensitivity yields ~0.05 kPa resolution at 10-bit ADC - adequate for tracking breath-by-breath pressure waveforms above 1 kPa. Integrated temperature compensation from 0 to 85 C covers clinical-room environments without external linearization. The non-corrosive gas media rating is appropriate for breathing circuits.

🏭

Filter / Orifice Pressure Monitoring

The MPX5010DP excels at filter-loading and orifice-plate monitoring because the differential measurement intrinsically cancels ambient barometric pressure. As a filter loads with particulates, the pressure drop across it rises from ~0 kPa (clean) toward 10 kPa (clogged) - the 0.2-4.7 V output feeds a microcontroller that triggers a replacement alert. The 5 V ratiometric output lets the reading track the ADC reference, eliminating absolute calibration drift. The 4.93 mm ports accept common flexible tubing used in HVAC and pneumatic systems.

🧩

Water Level Sensing via Air Column

By submerging one port of the MPX5010DP at the bottom of a vented tube and leaving the other port open to atmosphere, the sensor measures the hydrostatic head of water trapped in the air column - converting liquid level into differential pressure. A 10 kPa range corresponds to about 1 meter of water column, sufficient for residential sump, tank, and pool level monitoring. The dual-port design intrinsically cancels atmospheric pressure variation, and the ratiometric 5 V output can be read by a battery-powered MCU with a stable LDO reference.

🏭

Industrial Process Air Flow Measurement

For compressed-air flow metering and pneumatic control loops, the MPX5010DP provides a factory-calibrated differential pressure signal that directly correlates with flow rate through a Venturi or laminar flow element. The 0-10 kPa range covers typical shop-air pressure drops (1-5 kPa), and the 5 V supply is readily derived from industrial 24 V via a small DC-DC converter. The 6-SIP package is robust to industrial vibration, and the integrated temperature compensation removes the warm-up drift that plagues discrete bridge amplifiers.

✈️

Barometric / Altitude Estimation

Although primarily a differential sensor, the MPX5010DP can be used for low-altitude barometric trends by referencing one port to a sealed vacuum capsule and the other to atmosphere - effectively converting it to an absolute barometer with 0-10 kPa range (roughly sea level to 20,000 ft). The 450 mV/kPa sensitivity gives ~0.01 kPa resolution at 10-bit ADC, corresponding to about 1 meter of altitude. For higher-altitude barometric applications, the dedicated BMP280 absolute-pressure I2C sensor is the preferred choice - the MPX5010DP is best reserved for differential topologies.

🖥️

Small Fan / Blower Health Monitoring

By sensing the pressure rise across a small DC fan or blower, the MPX5010DP enables real-time airflow health monitoring - useful for server, embedded, and appliance fans where bearing wear manifests as a drop in static pressure. The 0.2-4.7 V analog output is read by the host MCU's ADC and trended over time; a falling baseline indicates degrading fan performance before failure. The differential topology rejects ambient barometric drift, and the 6-SIP package fits inside compact fan housings. Operating current is in the single-digit mA range, compatible with always-on monitoring.

What is the operating pressure range of the MPX5010DP?
The MPX5010DP measures differential pressure across 0 kPa to 10 kPa (0 to 1.45 PSI). According to the NXP/ST MPxx5010 datasheet, this range is calibrated at the factory and the analog output swings from 0.2 V (no pressure) to 4.7 V (full scale) at a 5 V supply, with a typical sensitivity of 450 mV/kPa. The dual-port configuration measures the difference between two air or non-corrosive gas sources.
Where can I buy the MPX5010DP online?
The MPX5010DP is in stock at DigiKey, Mouser and Arrow as of 2026-10-15, listed as an active STMicroelectronics part number (originally NXP). XAIPART also offers the MPX5010DP with quantity pricing from 1-piece through 1000-piece reels, with lead times of approximately 4-6 weeks for production volumes. For prototype quantities, distributor stock is recommended.
What is the price of the MPX5010DP?
The MPX5010DP lists at approximately USD 18.50 per unit at qty 1, falling to about USD 9.60 at qty 1000 (as of 2026-10-15 from DigiKey distributor listings). Volume pricing breaks are typical at 10, 100, 500 and 1000 pieces. Pricing on XAIPART tracks distributor reference and is published with the same quantity breaks on the product page.
What is the lead time for the MPX5010DP?
Stock lead time for the MPX5010DP at major distributors is typically 8-12 weeks as of 2026-10-15, reflecting active production by STMicroelectronics (which inherited the part from NXP). For urgent requirements, distributors with on-hand inventory ship same-day. Volume production orders above 1000 pieces should be planned with 16-week lead time to ensure allocation.
Is the MPX5010DP the same as the MPX5010GP?
No - the MPX5010DP and MPX5010GP are not pin-compatible drop-in equivalents. The MPX5010DP uses a 6-SIP package with dual 4.93 mm axial ports (differential measurement between two external sources), while the MPX5010GP uses a single-port gauge configuration in a different SIP body. Both share the same 0-10 kPa range and 450 mV/kPa sensitivity, but their port topologies and pinouts differ.
What is the difference between the MPX5010DP and the MPX5010GSX?
The MPX5010DP is a differential pressure sensor in a 6-SIP package with two 4.93 mm ports; the MPX5010GSX is a gauge (single-port) variant with a different port topology and surface-mount-style packaging. Both share the same 0-10 kPa range, 5 V supply and 0.2 V to 4.7 V output. They are NOT drop-in compatible due to differing pinouts and port layouts - swap only if you redesign the PCB.
When should I choose the MPX5010DP over the MPX5050DP?
Choose the MPX5010DP when your measurement range stays within 0-10 kPa and you want maximum resolution per kPa - its 450 mV/kPa sensitivity gives finer granularity than the MPX5050DP's 90 mV/kPa at the same 5 V supply. Choose the MPX5050DP when your system may see up to 50 kPa (e.g., higher-pressure HVAC or hydraulic filter monitoring), since the MPX5010DP would saturate near 10 kPa. Both share the same 6-SIP package and pinout, so the PCB footprint is reusable.
What is the best drop-in replacement for the MPX5010DP?
The MPXV5010G and MPX5010DP share the same 0-10 kPa calibrated range and 5 V supply but use different port topologies. For a true drop-in replacement on the same 6-SIP footprint, the MPXV5010G in the 6-SIP variant is the closest pin-compatible choice, although port size and orientation vary slightly. Always verify the mechanical drawing against your enclosure design before substituting.
Where to download the MPX5010DP datasheet PDF?
The official MPxx5010/MPXV5010 datasheet PDF is hosted at https://www.st.com/resource/en/datasheet/mpx5010dp.pdf (as of 2026-10-15). This STMicroelectronics-hosted document covers the MPX5010DP, MPXV5010G, MP3V5010 and MPVZ5010 variants. For the original NXP-branded datasheet, see https://www.nxp.com/part/MPX5010DP, which links to the same underlying document.
Where can I find the MPX5010DP pinout?
The MPX5010DP pinout is documented in the MPxx5010 datasheet at https://www.st.com/resource/en/datasheet/mpx5010dp.pdf. The 6-SIP package has 6 pins: pin 1 = VCC (5 V), pin 2 = VOUT, pin 3 = GND, pin 4 = N/C, pin 5 = N/C, pin 6 = N/C, with the two pressure ports on the opposite face of the package body. The components101 pinout diagram is consistent with this datasheet mapping.
What are the key specifications of the MPX5010DP that engineers should know?
Engineers designing with the MPX5010DP should focus on five key specifications: operating range 0-10 kPa (1.45 PSI) differential; sensitivity 450 mV/kPa typical; output 0.2-4.7 V on a 5 V ratiometric supply; linearity ±1.5% VFSS over 0-85 C; and the dual-port 6-SIP mechanical package. The ratiometric output means the reading scales with VCC - any supply noise directly couples into the measurement, so a clean 5 V rail with 100 nF decoupling is essential.
Can I use the MPX5010DP with a 3.3 V microcontroller ADC?
The MPX5010DP is specified for 4.75 V to 5.25 V supply - below 4.75 V the calibration and linearity are not guaranteed. To use it with a 3.3 V MCU ADC, drive the sensor from a clean 5 V rail and either (a) resistively divide the output to stay below 3.3 V (full-scale 4.7 V becomes 3.1 V after a 2:1 divider), or (b) use an external ADC with a 5 V reference. The MP3V5010 variant exists specifically for 3 V supply systems if a true 3.3 V ratiometric solution is required.
What is a waterproof alternative to the MPX5010DP?
For moisture-exposed or liquid-coupled applications, the MPVZ5010 family from NXP/ST uses a media-resistant gel coating that protects the die from condensation and water vapor, but the MPVZ5010 only comes in single-port gauge topology. For a truly waterproof differential pressure sensor with similar range, consider the CFSensor XGZP6895A (mentioned in cross-reference data) which supports -100 to 700 kPa with optional 5 V or 3.3 V supply and explicit drop-in compatibility with the MPX5010DP.
Is the MPX5010DP RoHS compliant?
Yes, the MPX5010DP is RoHS compliant per the STMicroelectronics product listing (as of 2026-10-15). It is supplied in a lead-free 6-SIP package suitable for Pb-free reflow profiles if wave soldering is used for the through-hole leads. REACH and conflict-minerals status should be confirmed via the manufacturer's latest declaration of conformity; the legacy Motorola/Freescale/NXP product family is generally compliant across all three frameworks.
How does the MPX5010DP compare to the BMP280 for pressure sensing?
The MPX5010DP and BMP280 are not drop-in alternatives - they target different measurement topologies. The MPX5010DP measures 0-10 kPa differential pressure with a calibrated 0.2-4.7 V analog output and is built for HVAC, filter monitoring, and flow sensing via differential ports. The BMP280 measures absolute pressure from 300-1100 hPa (30-110 kPa) over I2C/SPI and is built for barometric and altitude sensing. Use the MPX5010DP when you need differential low-pressure measurement; use the BMP280 for absolute barometric applications.

エンジニアリング参考データ: MPX5010DP — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPX5010DP when you need a calibrated, temperature-compensated differential pressure measurement in the 0-10 kPa range with a 5 V ratiometric analog output - ideal for HVAC VAV control, CPAP/respiratory monitoring, filter-loading detection, and small-fan health monitoring. The 450 mV/kPa sensitivity provides ample resolution for sub-0.1 kPa setpoint tracking on a 10-bit ADC. Choose the MPX5010GP or MPXV5010G if you need a single-port gauge (atmospheric-referenced) variant instead of differential. Choose the MPX5050DP if your measurement may exceed 10 kPa - same 6-SIP package, lower sensitivity, wider range. Choose the MP3V5010 for battery-powered 3.3 V systems where the 5 V supply is not available. For cross-brand drop-in with a wider programmable range, the CFSensor XGZP6895A is an option. All same-package alternatives reuse the same PCB layout, simplifying migration between range and topology variants within the MPxx5010 family.

代替品との比較

パラメータ この製品 MPXV5010G MPX5010GP MP3V5010 MPX5050DP XGZP6895A
Brand NXP Semiconductors (also sold by ST) NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Package 6-SIP Module 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same 6-SIP Module (MPX5010DP pinout compatible)
Pressure Range 0-10 kPa differential 0-10 kPa gauge 0-10 kPa gauge 0-10 kPa differential 0-50 kPa differential -100 to 700 kPa programmable
Sensitivity 450 mV/kPa 450 mV/kPa 450 mV/kPa 225 mV/kPa (3 V supply) 90 mV/kPa Configurable
Supply Voltage 4.75 V to 5.25 V (5 V typ) 4.75 V to 5.25 V 4.75 V to 5.25 V 2.7 V to 3.3 V (3 V typ) 4.75 V to 5.25 V 5 V or 3.3 V selectable
Output Type Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric or I2C
Port Configuration Differential (dual axial) Gauge (single port) Gauge (single port) Differential Differential Differential, configurable
Drop-in Compatible Reference Yes (port topology differs) Yes (port topology differs) Yes (supply voltage differs) Yes (range differs) Yes (default pin config)

主な差別化要因

  • Factory-calibrated, temperature-compensated output (vs MPX5050DP)
  • Standard 5 V ratiometric supply (vs 3 V) (vs MP3V5010)
  • True differential measurement (vs gauge) (vs MPXV5010G)
  • Higher pressure range (vs same package) (vs MPX5050DP)

設計ノート

The MPX5010DP output is ratiometric to VCC, so any noise or drift on the 5 V supply directly couples into the measurement. Place a 100 nF ceramic decoupling capacitor within 5 mm of pin 1 (VCC), and derive VCC from a low-noise LDO rather than directly from a switching regulator. For ADC readings, use VCC as the ADC reference so supply noise cancels out. Estimated supply current is in the single-digit mA range per datasheet typical conditions; a 50 mA LDO provides comfortable margin.

Route the analog output (pin 2) away from switching nodes, inductor coils, and high-current traces to minimize coupled noise. Keep both pressure ports mechanically isolated from the PCB to avoid stress on the sensor body, and use flexible silicone tubing (typically 4.93 mm / 3/16 in ID) with barbed fittings. Do not over-torque fittings - the SIP body is plastic and the internal port can crack above ~2 N·m.

Do not expose the ports to liquids, corrosive gases, or particulates - the die is bare silicon. For water or humidity exposure, route the medium through an air column or substitute the MPVZ5010 family with media-resistant gel. Do not apply pressure above the calibrated 10 kPa full scale without confirming the overload specification - permanent zero-shift can occur. Do not connect either port to a sealed volume during power-up; trapped pressure at 5 V supply application can produce transient over-range outputs.

The MPX5010DP output is a low-impedance analog voltage but the source impedance and capacitive load behavior is not formally specified; add a small RC filter (10 ohm + 100 nF) at the output if driving long cables or noisy ADC inputs. For ADC sampling, allow at least 1 ms settling time after multiplexer switching - the on-chip buffer has finite slew rate. Avoid driving the output into capacitive loads above 1 nF without a series resistor.

コンプライアンス情報

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
鉛フリー
Yes
ハロゲンフリー
Unknown
紛争鉱物
Compliant

RoHS and REACH compliance per STMicroelectronics product listing (2026-10-15). The MPX5010DP is a sensor IC, not automotive-qualified - AEC-Q100 does not apply. Lead-free 6-SIP package. Halogen-free status should be confirmed via latest manufacturer declaration.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPX5010DP MPX5010DP datasheet MPX5010DP NXP pressure sensor 10 kPa differential pressure sensor 5V MPX5010DP pinout 6-SIP MPX5010DP HVAC VAV controller MPX5010DP vs MPX5050DP MPX5010DP drop-in replacement MPX5010DP buy price MPX5010DP Arduino tutorial MPX5010DP CPAP medical sensor MPX5010DP filter pressure monitor

関連部品&用語

NXP Semiconductors STMicroelectronics MPX5010DP MPXV5010G MPX5010GP MP3V5010 MPX5050DP MPVZ5010 XGZP6895A CFSensor piezoresistive pressure sensor MEMS sensor differential pressure transducer pressure sensor IC 6-SIP module ratiometric analog output RoHS REACH HVAC VAV control CPAP respiratory monitor filter pressure drop water level sensing barometric pressure fan health monitoring
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示