NXP Semiconductors

MPX5500D - 500 kPa Differential Pressure Sensor | NXP

部品番号: MPX5500D ✓ 生産中
在庫あり 1〜3営業日以内に発送
0.2 V to 4.7 V Vdss 6-SIP Module Package
開始価格 $12.4 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $18.5 $18.50
10 $16.8 $168.00
100 $15.2 $1,520.00
500 $13.75 $6,875.00
1,000 $12.4 $12,400.00
ℹ️ すべての価格はUSDです

MPX5500D 概要

The NXP MPX5500D is a 500 kPa differential piezoresistive silicon pressure sensor with on-chip signal conditioning and temperature compensation, housed in a 6-pin SIP (Single In-line Package) module. It provides an analog output of 0.2 V to 4.7 V ratiometric to a 5 V supply, corresponding to 0 kPa to 500 kPa differential pressure across its two ports.

An integrated silicon pressure sensor is a monolithic semiconductor device in which a micromachined diaphragm deflects under applied pressure, changing embedded piezoresistive elements in a Wheatstone bridge. The MPX5500D belongs to the pressure sensor hierarchy: pressure transducer -> pressure sensor -> sensor IC -> signal conditioning IC -> semiconductor. Compared to resistive or ceramic capacitive sensors, monolithic silicon pressure sensors integrate amplification, calibration, and temperature compensation on the same die, eliminating external compensation circuitry and delivering near-direct ADC compatibility for microcontrollers.

Key features of the MPX5500D include a 0.2 V to 4.7 V analog output (0.5 V to 4.5 V typical usable span), 9 mV/kPa nominal sensitivity, 1 ms response time, ±1.5% accuracy over 0°C to 85°C, and ratiometric output operation from a single 4.75 V to 5.25 V supply. The on-chip ASIC performs laser-trimmed offset and span calibration, ensuring part-to-part interchangeability without external trim potentiometers. The device is also EMC-protected and qualified to typical industrial pressure-sensor environmental standards.

Typical applications include industrial process control, HVAC blower monitoring, water pressure monitoring, gas metering, and pneumatic system feedback in factory automation. Its differential (not gauge or absolute) reference makes it well-suited to measuring pressure drop across orifices, filters, or pumps in flow-derived systems. The 5 V ratiometric output connects directly to the ADC input of 5 V microcontrollers.

When designing with this device, decouple the Vs pin with a 100 nF ceramic capacitor placed within 5 mm of the lead. Apply pressure only via the silicone gel-protected side ports to avoid damaging the diaphragm, and avoid PCB stress on the SIP body that could couple mechanical strain into the sensor element.

ドロップイン代替品: MPX5500D — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPX5500D (同一形状・フットプリント) — 相違点: Output Type, Package, Operating Temperature, Supply Voltage, Accuracy.

NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Operating Temperature: -40 °C to +125 °C
Accuracy: 1.0 % full-scale (0 °C to 85 °C)
比較対象 MPX5500D →
NXP Semiconductors
Output Type: Analog, Ratiometric
Package: 6-SIP Module (Unibody)
Operating Temperature: -40 °C to +125 °C
比較対象 MPX5500D →
NXP Semiconductors
Output Type: Analog Voltage, Ratiometric
Package: 6-SIP Module (Case 867)
Operating Temperature: -40 °C to +125 °C
比較対象 MPX5500D →
STMicroelectronics
Operating Temperature: -40C to +125C (per ST datasheet family)
Supply Voltage: 5 V (typical)
比較対象 MPX5500D →
NXP Semiconductors
Output Type: Ratiometric analog voltage
Package: 6-SIP Module (Case 867-08, through-hole, ported)
比較対象 MPX5500D →
NXP Semiconductors
Output Type: Analog voltage (ratiometric)
Package: 6-SIP Module (6-Sensor)
Operating Temperature: -40C to +125C
比較対象 MPX5500D →

クイック比較ツール — 並列比較する代替部品を選択:

MPX5500DP

✅ ドロップイン ⚠️ 仕様未検証
STMicroelectronics
📦 6-SIP Module (dual-port housing)
Differential (Dual Port) · 500 kPa (72.52 PSI) · 0 kPa · Analog Voltage · 0.2 V to 4.7 V · 5 V (typical)

✓ 在庫あり

$4.86 / 個

データシートを見る →

MPX5050D

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 6-SIP Module
Differential Pressure Sensor · 0 kPa to 50 kPa (0 to 7.25 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · 7 mA (typical) · ±1.5% (over 0 to 50 kPa) · 1 ms (typical)

✓ 在庫あり

$9.85 / 個

データシートを見る →

MPX5100D

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 6-SIP Module
Piezoresistive Pressure Sensor (Differential) · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · Differential · 4.75 V to 5.25 V · 45 mV/kPa typical · Analog Voltage, Ratiometric · 0.2 V (zero pressure) to 4.7 V (full-scale)

✓ 在庫あり

$10.75 / 個

データシートを見る →

MPX4250D

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 6-SIP Module
Differential Pressure Sensor · 0 kPa to 250 kPa (0 to 36.26 psi) · Analog Voltage (ratiometric) · 0.2 V to 4.9 V · 4.85 V to 5.35 V (5.0 V typical) · 4.7 V (typical) · 1.0 % full-scale (0 °C to 85 °C) · 4.7 ms (typical)

✓ 在庫あり

$11.5 / 個

データシートを見る →

MPX5700D

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 6-SIP Module
Differential · 0 kPa to 700 kPa (0 to 101.53 PSI) · 4.8 V to 5.2 V (nominal 5.0 V) · 0.2 V to 4.7 V · Ratiometric analog voltage · ±2.5% (0 °C to 85 °C)

✓ 在庫あり

$12.03 / 個

データシートを見る →

MPX5999D

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 6-SIP Module
Integrated Silicon Pressure Sensor · Differential · 0 kPa to 1000 kPa (0 to 145.04 PSI) · 5 V · 0.2 V to 4.7 V · 2.5% (per NXP product page) · -40C to +125C

✓ 在庫あり

$7.95 / 個

データシートを見る →

MPX5500D 最大定格&電気的特性

Pressure Type Differential
Operating Pressure Range 0 kPa to 500 kPa
出力タイプ Analog Voltage
出力電圧範囲 0.2 V to 4.7 V
電源電圧 4.75 V to 5.25 V
Sensitivity 9 mV/kPa (nominal)
Accuracy ±1.5% (0°C to 85°C)
Response Time 1 ms
動作温度 0°C to 85°C
Storage Temperature -40°C to 125°C
パッケージ 6-SIP Module
実装タイプ Through-Hole
ピン数 6

MPX5500D ピン構成

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
ピン 1 Vcc — Supply voltage (5 V nominal)
ピン 2 GND — Ground
ピン 3 Vout — Analog output (0.2 V to 4.7 V)
ピン 4 NC — Not connected (per datasheet package layout)
ピン 5 NC — Not connected (per datasheet package layout)
ピン 6 NC — Not connected (per datasheet package layout)

主な用途

MPX5500D の用途: 6 件s: Industrial Pneumatic System Pressure Monitoring, HVAC Duct and Filter Pressure Drop Sensing, Water and Gas Pressure Monitoring, Medical and Laboratory Instrument Pressure Sensing, Engine and Vehicle System Pressure Monitoring, Portable Compressor and Pump Control.

🏭

Industrial Pneumatic System Pressure Monitoring

The MPX5500D's 0-500 kPa range and 9 mV/kPa sensitivity align precisely with industrial compressed air pressures typically regulated at 600-800 kPa (87-116 psi), allowing direct monitoring of regulated shop-air rails without mechanical pressure scaling. Placed in the supply manifold it feeds a 5 V microcontroller ADC ratiometric to the same rail, giving 0.2 V at no load and 4.7 V at full-scale pressure; the 1 ms response time tracks regulator dynamics faster than typical pneumatic actuators, while ±1.5% accuracy over 0°C to 85°C covers factory-floor temperature variation. Unlike gauge mechanical gauges, the on-chip conditioned output eliminates bourdon-tube drift and the silicone-gel isolation lets non-corrosive dry air contact the diaphragm directly, simplifying the pneumatic interface.

🔧

HVAC Duct and Filter Pressure Drop Sensing

Building HVAC systems need continuous filter-loading monitoring to schedule maintenance, and the MPX5500D measures differential pressure across a filter or fan coil in the typical 50-500 kPa working span with comfortable margin. Mounted across the filter, its two ports see ambient and post-filter pressures; the 0.2-4.7 V ratiometric swing connects to a 5 V HVAC controller ADC, where the 9 mV/kPa scale resolves small differential rises that signal filter clogging. The integrated temperature compensation ensures the reading does not drift with duct air temperature, and unlike a manometer the electronics pack into a control-board enclosure. Estimated: a 0-500 kPa unit at 10% filter loading produces roughly 0.5 V, at 50% loading about 2.4 V, and at alarm threshold about 3.6 V.

⚡

Water and Gas Pressure Monitoring

Municipal and process water systems typically operate at 100-700 kPa line pressure, squarely inside the MPX5500D's 0-500 kPa differential range, making it suitable for booster pump feedback and leak detection on non-aggressive liquid lines. Plumbed with the high-pressure port at the process side and the low-pressure port at atmosphere through a small reference tube, the sensor outputs a linear 0.2-4.7 V signal for direct ADC sampling. Compared with ceramic capacitive sensors, the silicon piezoresistive die delivers faster 1 ms response, better repeatability, and integrated temperature compensation without external EEPROM; designers should still add a media isolation diaphragm where water quality is uncertain, as the bare silicon is not corrosion-isolated.

💊

Medical and Laboratory Instrument Pressure Sensing

Bench-top autoclaves, sterilizers, and analytical instruments need reliable 0-500 kPa pressure feedback for cycle validation, and the MPX5500D's ±1.5% accuracy meets laboratory instrumentation needs over 0°C to 85°C. Located inside the pressure chamber, the SIP module is mounted with one port vented to atmosphere and the other exposed to the chamber, allowing direct differential measurement of gauge pressure during the sterilization cycle. The 1 ms response time captures pressure ramps, and the integrated ASIC removes the calibration burden per device. Estimated: a 200 kPa readback yields roughly 2.0 V on a 5 V supply, well inside the linear transfer region so instrument designers can subtract the offset in firmware.

🚗

Engine and Vehicle System Pressure Monitoring

Engine intake and oil gallery monitoring demands temperature-stable analog pressure transduction, and the MPX5500D's 0-500 kPa range covers boost pressures, transmission line pressure, and hydraulic accumulator pressures in light commercial equipment. Wired to a 5 V ECU ADC with ratiometric reference, the sensor's 9 mV/kPa slope translates boost fluctuations directly to engine-management firmware without external amplification. The integrated temperature compensation retains accuracy across engine bay thermal cycling, and the gel-protected front ports tolerate non-corrosive fluids and air. Estimated: a 250 kPa boost reading produces about 2.45 V, providing the resolution needed for closed-loop boost control algorithms in turbocharged engine conversions.

⚡

Portable Compressor and Pump Control

Portable air compressors and hydraulic pumps benefit from analog 0-500 kPa pressure feedback into 5 V battery-powered microcontrollers, and the MPX5500D's integrated signal conditioning eliminates the op-amp front end that discrete bridge sensors require. Power-cycled by a load switch, the sensor's typical 10 mA draw can be gated off in standby to extend battery life on cordless compressor units; the 1 ms response time is fast enough to detect tank-fill completion by watching the slope change as the regulator cuts in. Compared with electromechanical pressure switches, the ratiometric analog output provides variable hysteresis in firmware rather than a single fixed cut-out point.

What is the operating pressure range of MPX5500D?
The MPX5500D measures differential pressure from 0 kPa to 500 kPa, equivalent to approximately 0 to 72.5 psi. According to the NXP MPX5500 datasheet, this corresponds to an analog output swing of 0.2 V to 4.7 V on a 5 V ratiometric supply, making it suitable for medium-pressure industrial monitoring tasks such as pneumatic controls, water pressure, and HVAC filter monitoring.
What is the output voltage of MPX5500D at 250 kPa?
At half-scale pressure of 250 kPa the MPX5500D outputs approximately 2.45 V on a 5 V ratiometric supply, computed from the nominal 9 mV/kPa sensitivity and 0.2 V zero-pressure offset. The NXP datasheet confirms a typical linear transfer curve, but actual readings should be calibrated at zero and full scale per application notes to remove part-to-part error.
Is the MPX5500D ratiometric to supply voltage?
Yes, the MPX5500D output is ratiometric to its 5 V supply, meaning both zero-pressure output and full-scale output scale linearly with Vcc. According to the NXP datasheet, the nominal swing is specified for a 5.0 V supply; designers using 4.75 V or 5.25 V supply rails must divide the readings by Vcc to recover the absolute pressure reading, otherwise an A/D reference should be derived from the same 5 V rail.
What is the difference between MPX5500D and MPX5500DP?
The MPX5500D is the standard single-port differential SIP module, while the MPX5500DP adds a dual-port housing with two side pressure ports for inline plumbing connections. According to the FindIC comparison page, both share the same 0 kPa to 500 kPa range and 0.2 V to 4.7 V output, but the DP variant trades the basic SIP body for a plumbing-friendly enclosure at slightly higher cost.
Can MPX5500D be used to measure water pressure?
Yes, the MPX5500D is suitable for non-corrosive liquid pressure monitoring up to 500 kPa when used with compatible media-compatible fittings. Per the NXP datasheet, the sensor's gel-protected front side is rated for water, air, and non-aggressive fluids; however it should not be exposed to highly corrosive chemicals without a protective media isolation barrier, as the silicon die is not isolated.
Where can I download the MPX5500D datasheet PDF?
The official NXP MPX5500 datasheet PDF is available at https://www.nxp.com/docs/en/data-sheet/MPX5500.pdf. According to the manufacturer product page at https://www.nxp.com/products/MPX5500D, the datasheet contains electrical characteristics, typical transfer curves, mechanical drawings, and application guidance. Mirror copies are also indexed on alldatasheet.com and digchip.com as referenced in the verified web data.
How fast is the MPX5500D response time?
The MPX5500D response time is 1 ms, allowing reliable capture of dynamic pressure events such as pump transients and valve closures. According to the NXP MPX5500 datasheet, this 1 kHz mechanical response suits HVAC damper feedback and pneumatic control loops but is not fast enough for high-frequency combustion or detonation pressure measurement, where dedicated high-bandwidth transducers are required.
What is the accuracy of MPX5500D?
The MPX5500D is specified at ±1.5% accuracy over 0°C to 85°C, with the percentage referenced to the full-scale output. According to the NXP datasheet, this accuracy figure includes non-linearity, pressure hysteresis, and temperature errors combined; for tighter precision, a user calibration using a known reference pressure is recommended at commissioning.
What is the best drop-in replacement for MPX5500D?
The closest drop-in replacements for the MPX5500D are other members of the NXP MPX5500 series, including the MPX5500DP dual-port variant and the lower-range MPX5050D / MPX5100D, all sharing the same 6-SIP package pinout and ratiometric analog output. According to the verified web data, cross-brand alternatives in the same 6-SIP package are limited; most competitors use different mechanical form factors, so series-internal NXP variants are the safest substitutes.
How do I connect the MPX5500D to a microcontroller ADC?
Connect the MPX5500D output pin directly to the microcontroller's analog input and power Vs from a clean 5 V supply with a 100 nF decoupling capacitor placed within 5 mm of the SIP leads. According to the NXP datasheet, the three remaining pins are tied to ground; using the same 5 V rail as the ADC reference preserves ratiometric accuracy, allowing the ADC reading to be converted directly to pressure via the documented transfer function.
Is the MPX5500D RoHS compliant?
RoHS compliance status for the MPX5500D is not confirmed in the verified web data excerpt, so engineers should verify on the NXP product page or request the latest material declaration before designing in for the EU market. Per industry standards, most NXP SIP pressure sensors ship in lead-free terminal finishes, but the official RoHS certificate should be obtained for production documentation.
Can I use MPX5500D for absolute pressure measurement?
No, the MPX5500D is a differential sensor that measures the difference between two ports and does not provide a sealed absolute vacuum reference. According to the NXP datasheet, for absolute pressure measurements (e.g., sealed barometric systems) use the MPX4115A or MPXA6115A variants instead, both of which have an internal vacuum reference behind the diaphragm.
What is the supply current of MPX5500D?
The MPX5500D supply current is typically 10 mA from a 5 V supply under normal operation. According to the NXP datasheet, this current supplies the on-chip signal-conditioning ASIC and the bridge excitation; in battery-powered applications a load switch or regulator with shutdown control should be used to drop the quiescent draw to zero during standby.
What is a good second-source alternative for MPX5500D?
A second-source alternative in the same 6-SIP package and 0 kPa to 500 kPa range is limited in the verified web data, but the CFSensor XGZP6873A is documented as functionally equivalent at 5 V analog output for non-corrosive gas or air. According to the cfsensor.com listing, the XGZP6873A supports multiple pressure ranges including 0 kPa to 1000 kPa, but its port geometry and pinout may differ from the NXP 6-SIP layout, requiring PCB rework.
What are the key specifications of MPX5500D that engineers should know?
The MPX5500D delivers 0 kPa to 500 kPa differential pressure measurement with 9 mV/kPa nominal sensitivity, 0.2 V to 4.7 V ratiometric output, ±1.5% accuracy over 0°C to 85°C, 1 ms response time, and a 5 V single-supply interface in a 6-SIP through-hole package. According to the NXP datasheet, the integrated ASIC handles amplification and temperature compensation, allowing direct connection to a 5 V microcontroller ADC without external trim circuitry.

エンジニアリング参考データ: MPX5500D — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPX5500D when your system needs differential pressure measurement in the 0 kPa to 500 kPa range with ratiometric 5 V analog output and a simple 6-SIP through-hole package. Choose the MPX5500DP if your plumbing requires dual-port fittings for inline mounting on tubing. Choose the MPX5050D or MPX5100D when your pressure stays below 100 kPa (e.g., air-flow or vacuum monitoring) and you want higher mV/kPa sensitivity. Choose MPX4250D for sub-250 kPa spans, MPX5700D for up to 700 kPa, or MPX5999D for up to 1000 kPa where higher pressure capability is needed. All variants share the 6-SIP pinout, allowing PCB reuse across the MPX family as long as the analog front-end gain is matched to the chosen span.

代替品との比較

パラメータ この製品 MPX5500DP MPX5050D MPX5100D MPX4250D MPX5700D MPX5999D
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 6-SIP Module 6-SIP Module (dual-port) 6-SIP Module 6-SIP Module 6-SIP Module 6-SIP Module 6-SIP Module
Pressure Range 0-500 kPa 0-500 kPa 0-50 kPa 0-100 kPa 0-250 kPa 0-700 kPa 0-1000 kPa
Output Voltage 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Sensitivity 9 mV/kPa 9 mV/kPa 90 mV/kPa 45 mV/kPa 18 mV/kPa 6.4 mV/kPa 4.5 mV/kPa
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Response Time 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms
Operating Temperature 0°C to 85°C 0°C to 85°C 0°C to 85°C 0°C to 85°C 0°C to 85°C 0°C to 85°C 0°C to 85°C
Pressure Type Differential Differential Differential Differential Differential Differential Differential

主な差別化要因

  • Mid-range 0-500 kPa full-scale for general industrial pressure (vs MPX5100D)
  • 特長
  • Standard single-port 6-SIP body vs dual-port variant (vs MPX5500DP)
  • 5x more full-scale than MPX5050D (vs MPX5050D)

設計ノート

Estimated: decoupling the Vcc pin with a 100 nF ceramic capacitor placed within 5 mm of the MPX5500D SIP leads suppresses supply noise and stabilizes the ratiometric output. The sensor draws approximately 10 mA typical, so a low-dropout regulator with adequate headroom (e.g., 5.0 V LDO from a 7 V+ source) is preferred over a switching regulator whose ripple would alias into the pressure reading without adequate LC filtering at the sensor pin.

Do not apply pressure to the back-side or any non-port surface of the MPX5500D; only the silicone-gel-protected front ports should see media or air pressure, otherwise the glass bond can crack. Solder stress relief on the through-hole leads is also critical: avoid rigid PCB strain on the SIP body, as the package transfers mechanical strain directly into the silicon die and corrupts the reading; use a cable-tied strain relief or a rubber boot if the sensor is connected via tubing.

For best ADC accuracy, derive the analog reference of the microcontroller ADC from the same 5 V rail that powers the MPX5500D so the conversion is ratiometric to Vcc and cancels supply noise. Estimated: with a 10-bit ADC over a 5 V range, each LSB is about 4.9 mV, or roughly 0.54 kPa at the 9 mV/kPa slope; a 12-bit ADC raises that to roughly 0.13 kPa resolution, sufficient for industrial pneumatic and HVAC monitoring without external amplification.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

RoHS/lead-free status for MPX5500D not present in the verified web data. Designers should consult the NXP product page for the latest material declarations. AEC-Q100 is not specified; select an automotive-qualified NXP pressure sensor variant if required for vehicle applications.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPX5500D MPX5500D datasheet NXP MPX5500D pressure sensor 500 kPa differential pressure sensor 5V 6-SIP pressure sensor module MPX5500D pneumatic pressure monitoring MPX5500D vs MPX5500DP MPX5500D drop-in replacement MPX5500D buy price what is the output voltage of MPX5500D MPX5500D pinout 6-SIP analog ratiometric pressure transducer 5V

関連部品&用語

NXP Semiconductors MPX5500D MPX5500DP MPX5050D MPX5100D MPX4250D MPX5700D MPX5999D integrated silicon pressure sensor piezoresistive transducer monolithic silicon pressure sensor Wheatstone bridge pressure transducer pressure sensor sensor IC signal conditioning IC semiconductor differential pressure sensor ratiometric output HVAC pressure pneumatic system sensor RoHS AEC-Q100 6-SIP module
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示