NXP Semiconductors

MPX5010D - 10kPa Differential Pressure Sensor | NXP Semiconductors

部品番号: MPX5010D ✓ 生産中
在庫あり 1〜3営業日以内に発送
0.2 V to 4.7 V Vdss 6-SIP Module (Case 867-08) Package
開始価格 $8.25 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $12.5 $12.50
10 $11.4 $114.00
100 $10.2 $1,020.00
500 $9.1 $4,550.00
1,000 $8.25 $8,250.00
ℹ️ すべての価格はUSDです

MPX5010D 概要

The NXP Semiconductors MPX5010D is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation and calibration, providing a linear analog output proportional to applied differential pressure from 0 kPa to 10 kPa (0 to 1.45 PSI) in a 6-pin SIP Module (Case 867-08).

A piezoresistive transducer is a solid-state sensor that converts applied mechanical pressure into a proportional change in resistance of diffused silicon strain gauges arranged in a Wheatstone bridge. The MPX5010D belongs to the pressure-sensor / transducer family in the broader Sensors hierarchy, which itself sits within MEMS (Micro-Electro-Mechanical Systems). The integration of signal conditioning, temperature compensation and calibration directly on-chip distinguishes this part from raw Wheatstone-bridge sensing elements that require external amplifiers and trimming.

Key features include a 0.2 V to 4.7 V ratiometric analog output proportional to 5 V supply, a 4.75 V to 5.25 V supply range, a typical full-scale span of 4.5 V at 10 kPa, and a measured accuracy suitable for medical, industrial and consumer flow or level sensing applications. The device is engineered to interface directly with microcontrollers or microprocessors equipped with A/D inputs, eliminating the need for additional front-end analog circuitry in most designs.

At the architecture level the sensor combines advanced surface micromachining, thin-film metallization for the strain-gauge network, and bipolar signal-conditioning circuitry fabricated on the same silicon die. Temperature compensation and span calibration are laser-trimmed at the wafer level, so each part delivers a closely-matched transfer function across the 0C to +85C operating range. The differential pressure port geometry routes positive pressure to the top side of the diaphragm and reference pressure to the underside.

Typical applications include HVAC duct airflow measurement, medical respirator and ventilator flow paths, liquid level detection in non-corrosive reservoirs, industrial process control loops, barometric baseline correction in altimetry modules, and appliance water-level feedback. The differential configuration enables bidirectional flow sensing across an orifice or venturi element.

When designing with the MPX5010D, place a 0.1 uF decoupling capacitor within a few millimeters of the supply pin and use a stable 5 V reference for the ADC if absolute pressure accuracy beyond the ratiometric spec is required. Avoid exposure to harsh media - the silicon diaphragm is exposed through the port and should be protected with a compatible media-isolating cap in liquid applications.

This page synthesizes distributor pricing, drop-in alternatives and practical design notes beyond the manufacturer datasheet, organized for AEO citation. Pricing references are stated as of 2026-10-15.

ドロップイン代替品: MPX5010D — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPX5010D (同一形状・フットプリント) — 相違点: Mounting Type, Operating Temperature, Package, Technology, Output Type.

NXP Semiconductors
Mounting Type: Through-hole (SIP)
Operating Temperature: 0 C to +85 C (compensated)
Package: 6-SIP Module
比較対象 MPX5010D →
NXP Semiconductors
Mounting Type: Through-Hole (SIP)
Operating Temperature: -40 °C to +125 °C
Package: 6-SIP Module (Unibody)
比較対象 MPX5010D →
NXP Semiconductors
Mounting Type: Surface Mount
Package: 8-pin SOP (Small Outline Package), SMD Gull Wing
Technology: Piezoresistive, monolithic silicon
比較対象 MPX5010D →

クイック比較ツール — 並列比較する代替部品を選択:

MPX5010DP

✅ ドロップイン
NXP Semiconductors
📦 6-SIP Module (Case 867B)
Differential · 0 kPa to 10 kPa (0 to 1.45 PSI) · 450 mV/kPa (typical) · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · ±1.5% VFSS (typical, 0-85 C)

✓ 在庫あり

$9.6 / 個

データシートを見る →

MPXV5010GC6U

✅ ドロップイン
NXP Semiconductors
📦 6-SIP Module (Case 1735)
Pressure Sensor, Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · Top port, male 0.13 inch (3.17 mm) tube · 8-pin SOP (Small Outline Package), SMD Gull Wing

✓ 在庫あり

$8.2 / 個

データシートを見る →

MPX5010GC6U

✅ ドロップイン
📦 6-SIP Module (Case 482)
same die, gauge pressure version with single top port, equivalent electrical output, only port differs

📋 参考代替品(カタログ未掲載)

MPX5010D 最大定格&電気的特性

Manufacturer NXP Semiconductors
Pressure Type Differential
Operating Pressure 1.45 PSI (10 kPa) max
出力タイプ Analog Voltage
出力電圧範囲 0.2 V to 4.7 V
電源電圧 4.75 V to 5.25 V
Port Size Dual axial port (Differential)
動作温度 0C to +85C (industrial-grade derivative supported to 40C to +125C)
パッケージ / ケース 6-SIP Module (Case 867-08)
実装タイプ Through-hole module
Sensor Technology Piezoresistive MEMS
Signal Conditioning On-chip, temperature compensated and calibrated
Media Compatibility Dry non-corrosive gases (air-referenced diaphragm)

MPX5010D ピン構成

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
ピン 1 VCC — 5 V supply (4.75 V to 5.25 V), ratiometric reference for the output
ピン 2 GND — Common ground return for supply and signal chain
ピン 3 Vout — Analog voltage output, 0.2 V to 4.7 V proportional to applied differential pressure
ピン 4 NC — Not connected externally (factory trim network)
ピン 5 NC — Not connected externally (factory trim network)
ピン 6 NC — Not connected externally (factory trim network)

主な用途

MPX5010D の用途: 6 件s: HVAC Duct Airflow Measurement, Medical Respirator Flow Path, Liquid Level Detection in Reservoirs, Industrial Process Control Loops, Barometric Reference for Altimetry, Appliance Water-Level Feedback.

🏭

HVAC Duct Airflow Measurement

The MPX5010D's 0 to 10 kPa differential range matches the pressure drop produced by a small orifice or pitot tube in HVAC ducts, while its calibrated 0.2 V to 4.7 V ratiometric output can be sampled by a microcontroller ADC without additional analog front-end circuitry. Placing the sensor across a known restriction allows the host MCU to compute flow using the standard Q proportional to sqrt(DeltaP) relationship; the on-chip temperature compensation holds accuracy across the 0C to +85C supply-air range with no external drift trim, though bypass capacitance should be placed within a few millimeters of the supply pin to suppress ADC noise coupling.

💊

Medical Respirator Flow Path

For medical ventilator and CPAP flow paths the MPX5010D provides a low-noise, conditioned analog signal that is normally summed with reference-side pressure to derive patient flow. The silicon diaphragm is air-referenced and dry-media compatible, simplifying the pneumatic isolation stack; the 4.5 V full-scale span over 10 kPa yields a 4.5 mV/Pa resolution on a 12-bit ADC, sufficient for breath-shape analysis. Designers must add media-isolation and sterilization interfaces suitable for the clinical deployment because the silicon diaphragm is exposed through the port.

💧

Liquid Level Detection in Reservoirs

The MPX5010D works as a non-corrosive liquid level sensor when the high-pressure port is connected via an air column to the bottom of the tank, while the low-pressure port vents to atmosphere. The hydrostatic pressure scales linearly with liquid height, so a 10 kPa full-scale range corresponds to about 1 meter of water column at typical system factors; the ratiometric 0 to 4.7 V output feeds a 12-bit ADC for continuous level telemetry. Confirm media compatibility because the die is exposed and the part is intended for dry-gas pressure coupling only.

🏭

Industrial Process Control Loops

In industrial 4 mA to 20 mA loops and PLC analog inputs, the MPX5010D delivers a 0.2 V to 4.7 V conditioned signal that pairs naturally with industrial-grade A/D front-ends scaled to a 5 V reference. The differential measurement rejects common-mode disturbances common on long cable runs near motor drives and switching contactors. Apply a 0.1 uF decoupling capacitor and protective TVS clamps at the connector to handle ESD and inductive transients in cabinet installations.

✈️

Barometric Reference for Altimetry

Although primarily differential, the MPX5010D can be wired with the low-pressure port sealed against a known reference and the high-pressure port exposed, turning it into a high-accuracy barometric altimeter with 10 kPa headroom. ADC sampling at 1 Hz and software low-pass filtering yields altitude readings comparable to low-end altimeter modules and GPS augmentation. Use a sealed reference chamber to keep the differential baseline stable against environmental drift.

🧩

Appliance Water-Level Feedback

Washing machines, dishwashers and coffee appliances exploit the MPX5010D's 0 to 10 kPa range to detect water-column height without dipping any electronics into the fluid, simply by routing an air tube to the bottom of the sump. The conditioned 0 to 4.7 V signal feeds the appliance MCU directly, replacing legacy mechanical float switches with a quiet, reliable solid-state sensor. Add a water trap and lint guard at the air-tube pickup because the sensor's port is sized for clean air only.

What is the operating pressure range of the MPX5010D?
The MPX5010D measures differential pressure from 0 kPa to 10 kPa (0 to 1.45 PSI) and produces a ratiometric analog output of 0.2 V to 4.7 V from a 5 V supply. The output is linear with applied differential pressure according to the datasheet transfer function, making the sensor suitable for clean gas-flow and level-sensing applications up to its full-scale range.
Where can I buy the MPX5010D online?
The MPX5010D is stocked and shipped from authorized distributors including DigiKey (part 951808), Mouser and Octopart-listed resellers, as of 2026-10-15. Distributor inventory on these channels typically supports same-day shipment for cut-tape or tray quantities and is the most reliable supply path for production volumes.
What is the typical lead time for the MPX5010D?
Based on DigiKey and Mouser listings as of 2026-10-15, the MPX5010D typically ships within 2 to 4 weeks from distributor stock, with limited historical shortages affecting the broader MPxx5010 family. For higher-volume orders above 1000 units, requested lead times of 6 to 8 weeks are common from franchise distributors.
What is the price of the MPX5010D in 100-piece quantity?
At a 100-piece quantity break the MPX5010D unit price is approximately 10.20 USD based on aggregated distributor pricing as of 2026-10-15. Price at qty-1 is approximately 12.50 USD and reduces toward roughly 8.25 USD at 1000 pieces, reflecting standard MPxx5010-series distributor volume curves.
What is the output voltage range of the MPX5010D?
The MPX5010D ratiometric analog output spans 0.2 V at zero differential pressure to 4.7 V at the full 10 kPa differential pressure, when excited with a 5.0 V supply. Because the output scales linearly with VCC, designers should drive the sensor from the same 5 V rail that supplies the reference input of the ADC to retain absolute accuracy.
MPX5010D vs MPX5010DP - what is the difference?
The MPX5010DP is the dual-port axial variant of the same die offering identical 0.2 V to 4.7 V output over 0 to 10 kPa differential, whereas the MPX5010D is the through-hole SIP with two side-by-side port stubs. Functionally the sensing element is equivalent; the difference is purely mechanical port orientation - choose DP for inline tubing, D for manifold-style mounting.
Can the MPX5010DP replace the MPX5010D?
The MPX5010DP is functionally equivalent but NOT a pin-for-pin drop-in for the MPX5010D because the port stubs project from the opposite face of the package (Case 867B vs Case 867-08). Confirm port orientation and PCB cutout availability before substituting the DP variant for the D variant on an existing manifold - air-path mechanical compatibility differs even when the electrical transfer function is identical.
When should I choose the MPX5010D over the MPX5010DP?
Choose the MPX5010D for designs that need side-by-side dual-port geometry on a through-hole SIP footprint, with both ports accessible from the same face of the module. Choose the MPX5010DP instead when your tubing enters and exits from opposite faces of the device, a typical configuration for inline flow elements.
What is the best drop-in replacement for the MPX5010D?
There is no widely accepted 100% pin-compatible drop-in replacement for the MPX5010D 6-SIP Case 867-08 form factor. The closest NXP alternatives are the case-style variants MPX5010DP, MPX5010GC6U and MPXV5010GC6U, which share the same silicon die and 0 to 10 kPa range but differ in port orientation. Cross-brand 10 kPa differential pressure sensors from Honeywell or TE Connectivity typically require PCB rework.
Is the MPX5010D the same as the Honeywell 24PC series?
No - the MPX5010D and Honeywell 24PC series are functionally similar 0 to 10 psi-class differential pressure sensors with on-chip conditioning, but they use different package geometries, port orientations and pin assignments. Verify footprint and pinout against your PCB land pattern before substituting; in most cases PCB rework is required to migrate between NXP and Honeywell small-package pressure sensors.
Where can I download the MPX5010D datasheet PDF?
The MPX5010D datasheet is hosted on the NXP product page at https://www.nxp.com/docs/en/data-sheet/MPX5010.pdf and is mirrored on third-party archive sites including alldatasheet.com and digchips.com. The PDF includes the transfer function plot, port geometry, typical application circuit and absolute maximum ratings needed for design review.
Where do I find the MPX5010D pinout?
The MPX5010D pinout for the 6-SIP Case 867-08 module follows the standard MPxx5010 family assignment: pin 1 VCC, pin 2 GND, pin 3 Vout, and the three remaining pins tied to internal sensing/trim networks per the datasheet. Always recheck against the latest manufacturer datasheet because the unused pins are reserved for factory trim and should remain as documented.
What is the operating temperature range of the MPX5010D?
The MPX5010D is specified for operation from 0C to +85C and storage from -40C to +125C, per the NXP datasheet family characterization. For applications requiring extended industrial exposure outside this range, consult NXP application notes on thermal derating or migrate to the higher-temperature rated part variants from the same MPxx5010 family.
What interface circuit do I need for the MPX5010D with a microcontroller?
The MPX5010D can be connected directly to a microcontroller ADC channel: route the 5 V supply through a 0.1 uF decoupling capacitor to pin 1, ground pin 2, and feed pin 3 output into an ADC input referenced to the same 5 V rail for ratiometric accuracy. No external op-amp is required because the on-chip signal conditioning delivers a buffered 0.2 V to 4.7 V swing ready for 10-bit to 12-bit ADCs.
Is the MPX5010D RoHS compliant?
RoHS compliance status for the MPX5010D should be confirmed against the latest NXP product page or certificate of conformance because the part has been manufactured across multiple decades from Motorola, Freescale and NXP ownership transitions. Refer to the manufacturer part ordering information section of the datasheet for the current lead-free / RoHS-compliant part-number suffix.

エンジニアリング参考データ: MPX5010D — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPX5010D when the design needs a 0 to 10 kPa differential pressure measurement in a through-hole 6-SIP with side-by-side ports for manifold-style mounting, with a 5 V ratiometric analog output and on-chip conditioning ready to feed a 12-bit ADC. Pick the MPX5010DP instead when your plumbing uses inline tubing with opposed axial ports. Choose the MPXV5010GC6U or MPX5010GC6U for gauge-only sensing or for surface-mount / compact PCB form factors; the trade-off vs MPX5010D is loss of differential capability. All four parts use the same silicon piezoresistive transducer family with 0 to 10 kPa full-scale and similar electrical transfer functions.

代替品との比較

パラメータ この製品 MPX5010DP MPXV5010GC6U MPX5010GC6U
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 6-SIP Module (Case 867-08) 6-SIP Module (Case 867B) 6-SIP Module (Case 1735) 6-SIP Module (Case 482)
Pressure Type Differential Differential Gauge Gauge
Operating Pressure 10 kPa (1.45 PSI) 10 kPa (1.45 PSI) 10 kPa (1.45 PSI) 10 kPa (1.45 PSI)
Output Voltage Range 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Port Configuration Dual side-by-side axial ports Dual opposed axial ports Single top-side gauge port Single top-side gauge port
Silicon Die MPX5010 family die MPX5010 family die (same) MPXV5010 family die MPX5010 family die (same)

主な差別化要因

  • Differential pressure with on-chip signal conditioning (vs MPXV5010GC6U)
  • Same NXP MPX5010 die as DP variant (vs MPX5010DP)
  • Calibrated and temperature compensated on-chip (vs Raw Wheatstone-bridge pressure sensors)

設計ノート

The MPX5010D is ratiometric - its output scales with supply - so power it from the same clean 5 V rail that supplies the ADC reference to retain absolute pressure accuracy across the 0.2 V to 4.7 V output span. Place a 0.1 uF ceramic bypass capacitor within a few millimeters of the VCC pin to suppress digital switching noise; the part draws only a few milliamps so no bulk capacitor is needed, but the supply must stay within 4.75 V to 5.25 V to keep the calibration intact.

Avoid exposing the silicon diaphragm directly to liquid, dust or corrosive media because the sensing element is exposed through the port. Use a compatible media-isolating diaphragm or hydrophobic filter at the pneumatic pickup point. Leaving pins 4-6 floating is correct - they tie to factory trim networks and must not be grounded externally; ignoring this can disturb the calibrated transfer function.

Route the analog output (pin 3) away from switching converter inductors and high-current traces to prevent switching-noise coupling into the ADC input. A small RC low-pass on the output (10 kHz typical) is usually sufficient because the sensor bandwidth is intrinsically limited; higher software oversampling can be used to further improve effective resolution on top of any low-pass filter.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Qualified
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

RoHS, lead-free and REACH status should be verified against the current NXP product page or certificate of conformance because the part has been manufactured across Motorola, Freescale and NXP ownership transitions. The MPX5010D is not AEC-Q100 qualified; consult the automotive MP3V5010 / MPXV5010 line for vehicle applications.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPX5010D datasheet MPX5010D NXP differential pressure sensor MPX5010D 10kPa 0-4.7V analog output MPX5010D 6-SIP Case 867-08 pinout MPX5010D HVAC airflow sensor MPX5010D vs MPX5010DP MPX5010D drop-in replacement buy MPX5010D online what is the operating pressure of MPX5010D MPX5010D MCU ADC interface circuit MPX5010D medical ventilator flow sensor MPX5010D water level sensor

関連部品&用語

NXP Semiconductors MPX5010D MPX5010DP MPXV5010GC6U MPX5010GC6U piezoresistive transducer differential pressure sensor Wheatstone bridge MEMS ratiometric analog output 6-SIP Module Case 867-08 through-hole mount RoHS AEC-Q100 signal conditioning temperature compensation on-chip calibration HVAC airflow measurement medical ventilator liquid level detection industrial process control barometric altimetry appliance water level Freescale Semiconductor Motorola
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示