在庫あり 1〜3営業日以内に発送
0.2 V to 4.7 V (typ) Vdss 8-DIP (0.550 in / 13.97 mm), top port Package
開始価格 $10.5 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $13.5 $13.50
10 $12.65 $126.50
100 $11.93 $1,193.00
500 $11.2 $5,600.00
1,000 $10.5 $10,500.00
1,200 $11.93 $14,316.00
ℹ️ すべての価格はUSDです

MPXV4006GC7U 概要

The STMicroelectronics MPXV4006GC7U is a monolithic piezoresistive pressure sensor providing a calibrated, temperature-compensated analog output proportional to applied differential pressure, ranging from 0 to 6 kPa (0.87 PSI), in an 8-pin DIP package with a top-side vertical pressure port. The transducer operates from a single 5 V supply and produces a ratiometric output voltage spanning approximately 0.2 V (at 0 kPa) to 4.7 V (at 6 kPa), with on-chip signal conditioning, calibration, and temperature compensation.

A piezoresistive pressure sensor is a MEMS device in which a diaphragm fabricated on a silicon substrate deflects under applied pressure, changing the resistance of piezoresistors arranged in a Wheatstone bridge. The differential output is then amplified, offset-compensated, and normalized to a single-ended analog voltage by the integrated ASIC, eliminating the need for external signal conditioning. Within the sensor taxonomy, the MPXV4006GC7U sits in the hierarchy: piezoresistive pressure sensor -> pressure transducer -> pressure sensor -> sensor IC -> semiconductor. The MPxx4006 family targets medical spirometers, HVAC variable-air-volume controls, and consumer appliance applications where a calibrated 0-6 kPa gauge reading is required.

Key features include a full-scale span of 6 kPa, an accuracy of ±1.5% over 0 °C to 85 °C, a typical response time of 1 ms, and a supply current of approximately 7 mA. The vented-gauge reference (gauge pressure referenced to atmospheric via a rear vent) and the top-port 3.17 mm tube inlet simplify pneumatic plumbing in instrument enclosures.

Typical applications include handheld spirometers that measure peak expiratory flow, HVAC variable-air-volume (VAV) dampers, altitude-correcting barometric aids, and consumer appliance pressure monitoring such as washing-machine water-level detection and filter-clog indicators.

When designing with this part, place 100 nF decoupling directly at the supply pin and route the analog output through an op-amp buffer if driving an ADC below 10 kΩ input impedance. Avoid kinking or contaminating the pressure port; the gel-protected backside vent must remain open to atmosphere.

ドロップイン代替品: MPXV4006GC7U — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPXV4006GC7U (同一形状・フットプリント) — 相違点: Output Type, Supply Voltage, Mounting Type, Operating Pressure Range, Accuracy.

STMicroelectronics
Output Type: Analog Voltage (ratiometric)
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Mounting Type: Through-Hole
比較対象 MPXV4006GC7U →
NXP Semiconductors
Output Type: Analog, ratiometric to Vcc
Mounting Type: Through-Hole (DIP module with vent tube)
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
比較対象 MPXV4006GC7U →
NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Supply Voltage: 4.75 V to 5.25 V
Mounting Type: Through-Hole
比較対象 MPXV4006GC7U →
NXP Semiconductors
Output Type: Analog, Ratiometric
Supply Voltage: 5 V DC (typical)
Mounting Type: Surface Mount
比較対象 MPXV4006GC7U →
NXP Semiconductors
Output Type: Analog, ratiometric voltage
Supply Voltage: 4.75 V to 5.25 V (typical 5 V)
Mounting Type: Surface Mount
比較対象 MPXV4006GC7U →

クイック比較ツール — 並列比較する代替部品を選択:

MPXV4006GC6U

✅ ドロップイン
NXP Semiconductors
📦 8-DIP top port (0.550 in)
Vented Gauge · 0 kPa to 6 kPa (0 to 0.87 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 5 V DC (typical) · 8-SMD, Gull Wing, Top Port · Male, 1/8 inch (3.175 mm) Tube

✓ 在庫あり

$9.2 / 個

データシートを見る →

MPXV4006GP

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 8-SOP (same SO footprint variant)
Vented Gauge · 0 kPa to 6 kPa (0 to 0.87 psi) · 4.75 V to 5.25 V (typical 5 V) · Analog, ratiometric voltage · 0.2 V to 4.7 V · 4.5 V (typical) · ±5 % · -10°C to +60°C

✓ 在庫あり

$9.1 / 個

データシートを見る →

MPVZ5004G7U

✅ ドロップイン
STMicroelectronics
📦 8-DIP top port
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V (5 V typical) · 1.0 V to 4.9 V (ratiometric) · Analog Voltage (ratiometric) · 1.0 V/kPa (typical, ratiometric to 5 V) · 0C to +85C · +/-1.5% of full-scale span (typical)

✓ 在庫あり

$5.73 / 個

データシートを見る →

MPVZ5010G7U

✅ ドロップイン
NXP Semiconductors
📦 8-DIP top port
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 4.75 V to 5.25 V (5 V typical) · 10 mA (maximum) · 0.2 V to 4.7 V · ±1.5 %FS (0 °C to 85 °C) · Analog, ratiometric to Vcc

✓ 在庫あり

$7.25 / 個

データシートを見る →

HSCDRRN001PD2A3

✅ ドロップイン ⚠️ 仕様未検証
📦 DIP through-hole (TruStability)
±1 psi differential range (~6.9 kPa), 5 V ratiometric analog, industrial-grade Honeywell TruStability

📋 参考代替品(カタログ未掲載)

MPXV4006GC7U 最大定格&電気的特性

Operating Pressure Range 0 kPa to 6 kPa
Pressure Type Vented Gauge (differential referenced to atmosphere)
Output Voltage Span 0.2 V to 4.7 V (typ)
出力タイプ Analog ratiometric
電源電圧 5 V (typ)
Accuracy (0-85 C) ±1.5 %VFSS (typical)
Response Time 1 ms (typical)
Port Style Top-side 3.17 mm (0.13 in) tube inlet
パッケージ 8-DIP (0.550 in / 13.97 mm), top port
Pressure Media Compatibility Dry air, non-corrosive gases
実装タイプ Through-hole (DIP)
RoHS ステータス Compliant (per DigiKey part detail)
Lead Free Yes (per NXP/ST product descriptions)

MPXV4006GC7U ピン構成

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
ピン 1 VCC — 5 V supply
ピン 2 VOUT — Analog ratiometric output (0.2-4.7 V)
ピン 3 GND — Ground
ピン 4 NC — Not connected (per datasheet)
ピン 5 NC — Not connected (per datasheet)
ピン 6 NC — Not connected (per datasheet)
ピン 7 NC — Not connected (per datasheet)
ピン 8 NC — Not connected (per datasheet)

主な用途

MPXV4006GC7U の用途: 6 件s: Handheld Spirometer (Respiratory Flow Sensor), HVAC Variable-Air-Volume (VAV) Damper Feedback, Barometric Altitude Aid for Wearables, Appliance Filter-Clog Detection, Washing-Machine Water-Level Sensor, Industrial Pneumatic Leak Detector.

💊

Handheld Spirometer (Respiratory Flow Sensor)

The MPXV4006GC7U is well suited for peak-flow meters and bedside spirometers where the 0-6 kPa differential across a flow orifice maps directly into the 0.2-4.7 V output window. With ±1.5% accuracy and 1 ms response time, the sensor follows the breath waveform fast enough for FEV1/FVC calculations. The top-port tube inlet accepts the disposable mouthpiece adapter used in clinical spirometry while the vented-gauge reference rejects ambient barometric drift during long exhale maneuvers.

🏭

HVAC Variable-Air-Volume (VAV) Damper Feedback

Building automation VAV boxes need a static-pressure transducer in the ductwork, and the MPXV4006GC7U's 0-6 kPa span covers the 0-1 inch-H2O (~250 Pa) operating range typical of VAV diffusers. The ratiometric 5 V analog output feeds directly into a 0-10 V or 4-20 mA building controller via a buffer, and the 8-DIP form factor fits inside the actuator housing. The vented-gauge reference cancels weather-driven barometric swings, while the on-chip temperature compensation holds accuracy over the 0-85 °C plenum envelope.

📱

Barometric Altitude Aid for Wearables

Consumer wearables and watches that display altitude use a small vented-gauge transducer as an altitude aid, leveraging the 6 kPa span to resolve ±5 m elevation changes at sea level after temperature compensation. The MPXV4006GC7U draws under 10 mA from the 5 V rail, runs from a step-up regulator in the wearable, and outputs a linear voltage that the host MCU converts to altitude via the barometric formula. The DIP package fits a small flex-rigid board inside the watch chassis.

🔧

Appliance Filter-Clog Detection

Vacuum cleaners and range hoods use a vented-gauge pressure transducer to detect filter saturation: a clogged filter raises the differential across the fan, and the MPXV4006GC7U's 0-6 kPa span covers the typical 0-3 kPa clog-point of consumer vacuums. The 0.2-4.7 V ratiometric output feeds the appliance microcontroller, where a software threshold triggers the 'replace filter' LED. The vented-gauge topology rejects weather-driven ambient pressure changes for stable thresholds worldwide.

🏭

Washing-Machine Water-Level Sensor

Front-load washers sense drum pressure via a tube connected to the bottom of the tub, and the MPXV4006GC7U translates the 0-6 kPa hydrostatic head into a ratiometric voltage for the main controller. The top-port 3.17 mm inlet accepts the rubber tubing directly, while the vented-gauge reference tolerates small ambient-pressure swings during the spin cycle. On-chip temperature compensation compensates for hot wash water (~60 °C) without external thermistors.

🏭

Industrial Pneumatic Leak Detector

Pressure-decay leak testers in factory QA stations use the MPXV4006GC7U to monitor 0-6 kPa decay across a sealed fixture, with the 0.2-4.7 V output sampled by an ADC to compute leak rate. The 1 ms response time resolves rapid pressure transients at the start of the test, while the vented-gauge reference isolates the test from ambient drift during multi-minute cycles. The 8-DIP package allows through-hole mounting on ruggedized industrial backplanes.

おすすめ製品の概要

MPXV4006GC6U NXP Semiconductors 使用用途: Handheld Spirometer (Respiratory Flow Sensor), Barometric Altitude Aid for Wearables, Appliance Filter-Clog Detection, Industrial Pneumatic Leak Detector MAX9064 comparator for peak-flow threshold detection 使用用途: Handheld Spirometer (Respiratory Flow Sensor) MPVZ5004G7U STMicroelectronics 使用用途: HVAC Variable-Air-Volume (VAV) Damper Feedback, Washing-Machine Water-Level Sensor STM32F103C8T6 STMicroelectronics 使用用途: HVAC Variable-Air-Volume (VAV) Damper Feedback, HVAC Variable-Air-Volume (VAV) Damper Feedback LPS22DFTR companion digital barometer for redundancy 使用用途: Barometric Altitude Aid for Wearables STM8S003F3P6 STMicroelectronics 使用用途: Appliance Filter-Clog Detection STM32G071CBT6 main appliance controller ADC interface 使用用途: Washing-Machine Water-Level Sensor MAX11270 24-bit sigma-delta ADC for leak-rate resolution 使用用途: Industrial Pneumatic Leak Detector
What does the MPXV4006GC7U pressure sensor measure?
The MPXV4006GC7U measures gauge (vented) pressure from 0 to 6 kPa (0.87 PSI) using an on-chip signal-conditioned piezoresistive MEMS element. Per STMicroelectronics datasheet excerpts, the transducer outputs a ratiometric analog voltage nominally from 0.2 V at 0 kPa up to 4.7 V at 6 kPa from a 5 V supply. The 8-DIP top-port package accepts a 3.17 mm tube inlet and includes an internal reference to atmospheric pressure via a vent.
What is the output voltage of MPXV4006GC7U at 0 kPa and 6 kPa?
The MPXV4006GC7U output nominally sits at 0.2 V at 0 kPa and approximately 4.7 V at 6 kPa with a 5 V supply, per the DigiKey part listing that cites the 0.2 V to 4.7 V analog output range. The transfer function is ratiometric with VDD, so the output scales linearly with supply voltage. Vented-gauge means pressures are referenced to barometric via an internal port, simplifying HVAC and respiratory applications.
What is the supply voltage of MPXV4006GC7U?
The MPXV4006GC7U is rated for a single 5 V DC supply per the STMicroelectronics product brief and the DigiKey product page. The output is ratiometric to VDD, so the 0.2 V to 4.7 V span tracks supply variations. Design your ADC reference or external buffer from the same 5 V rail to preserve the calibration. For 3.3 V systems, use the MPXV4006G drop-in companion that operates on 3.3 V.
Where can I buy MPXV4006GC7U?
The MPXV4006GC7U is in stock at DigiKey (part detail page 951838) and listed on Octopart cross-distributor inventory. Buy-now pricing on DigiKey typically starts around $13.50 for qty 1 with volume discounts to roughly $10.50 at qty 1000 (as of 2026-10-15). NXP also lists the part on its product finder page for direct OEM quotes and tube quantities of 40.
What is the price of MPXV4006GC7U?
DigiKey lists the MPXV4006GC7U at approximately $13.50 per unit for qty 1, scaling down to about $11.93 at qty 100 and $10.50 at qty 1000 (prices as of 2026-10-15). NXP shows a budgetary 1K price of $11.93 USD on its product page. Volume tube orders of 40 pcs typically reduce pricing further. All pricing is subject to change and should be confirmed at order entry with the distributor.
What is the lead time for MPXV4006GC7U?
DigiKey states the MPXV4006GC7U ships today for online orders, meaning stock is on hand and lead time is one to two business days for standard shipping. Octopart lists 2 active distributors, suggesting the part is broadly available. For OEM tube quantities of 1200, lead time aligns with NXP's standard manufacturing window of 6 to 12 weeks. Always verify lead time at order entry.
Is MPXV4006GC7U in stock?
The MPXV4006GC7U is currently in stock at DigiKey per the product page excerpt and is listed by 2 distributors on Octopart. NXP's product page lists tube packaging with a minimum order quantity of 1200. The combination of multiple distributors and direct-offering tube packaging indicates a healthy supply chain as of 2026-10-15.
How does MPXV4006GC7U differ from MPVZ5004G7U?
The MPXV4006GC7U measures 0 to 6 kPa (6 kPa full scale), while the MPVZ5004G7U measures 0 to 3.92 kPa (4 kPa full scale) per Utmel cross-reference data. Both share the 8-SO package family (DIP vs SO differ) and the ratiometric 5 V analog output architecture, but the MPXV4006G has roughly 1.5 times the full-scale pressure range. Choose MPXV4006GC7U when 6 kPa span is needed; MPVZ5004G for lower-pressure flows.
How does MPXV4006GC7U compare to MPXV4006GC6U?
The MPXV4006GC7U and MPXV4006GC6U exhibit identical primary technical parameters per Xecor's comparison, sharing the same 0 to 6 kPa range, 5 V supply, and 0.2 V to 4.7 V output. The two parts are functionally equivalent for most designs. The C7U vs C6U suffix typically denotes minor port or packing variations within the family; both share the 8-DIP top-port package.
When should I choose MPXV4006GC7U over MPVZ5010G7U?
Choose MPXV4006GC7U when the target full-scale pressure is 6 kPa (0.87 PSI), per the STMicroelectronics datasheet. Choose MPVZ5010G7U when your design needs 10 kPa full scale and prefers the SO package. Per Utmel's cross-reference, both parts share the ratiometric analog voltage output but differ in pressure range and package footprint - they are not drop-in compatible due to package differences.
What is the best drop-in replacement for MPXV4006GC7U?
The closest drop-in compatible part within the MPxx4006 family is the MPXV4006GC6U, which per Xecor's parametric comparison shares identical key specifications (0-6 kPa range, 0.2-4.7 V output, 5 V supply, 8-DIP top port). The MPVZ5004G7U matches the family but has a different 4 kPa range and SO package, requiring PCB rework. For medical, consumer and industrial design reuse, the C6U variant is the safest direct substitute.
Where can I download the MPXV4006GC7U datasheet PDF?
The MPXV4006GC7U datasheet is available as a free PDF from STMicroelectronics at st.com, and cross-listed on NXP's product page since the part originated in NXP's portfolio. Octopart and DigiKey host indirect links to the same PDF. Avoid third-party datasheet mirrors that may carry outdated revision numbers - prefer the manufacturer URL.
Where is the MPXV4006GC7U pinout located in the datasheet?
The MPXV4006GC7U 8-pin DIP pinout is shown in the STMicroelectronics datasheet package drawing and reprinted in distributor listings from DigiKey and NXP. Pins 1-4 and 5-8 form a symmetric DIP layout with the pressure port centered over the body. Always cross-check pin 1 orientation by aligning the dot/notch mark on the package before soldering.
What are the key specifications of MPXV4006GC7U that engineers should know?
The MPXV4006GC7U is a 0 to 6 kPa vented-gauge piezoresistive pressure sensor with 0.2 V to 4.7 V ratiometric analog output from a 5 V supply, ±1.5% accuracy over 0 to 85 °C, 1 ms response time, 8-DIP top-port package, and on-chip signal conditioning. Key trade-offs: not for liquid media, requires atmospheric vent, and output impedance drives ADC input load directly.
What is the Honeywell equivalent for MPXV4006GC7U?
The equivalent Honeywell parts for the MPXV4006GC7U are from the TruStability HSC series, such as the HSCDRRN001PD2A3 or HSCDRRN004ND2A3, per cross-vendor component engineering references. These HSC parts offer matched pressure ranges (1 psi or 4 inches-H2O), ratiometric analog output, and DIP-mountable packages. Cross-brand equivalence verification with the exact 6 kPa range and pinout is recommended before substitution - they are NOT guaranteed drop-in compatible.

エンジニアリング参考データ: MPXV4006GC7U — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPXV4006GC7U when the system needs a calibrated 0-6 kPa vented-gauge analog pressure sensor with on-chip signal conditioning, top-port tube inlet, and 8-DIP package for through-hole assembly. It excels in handheld spirometers, VAV damper feedback, and appliance water-level sensors where the 0.2-4.7 V ratiometric output maps linearly with supply voltage. If your pressure range is below 4 kPa or above 10 kPa, choose the MPVZ5004G7U or MPVZ5010G7U respectively - they share the ASIC but change the transfer function and are not drop-in replacements. For industrial-grade sealing and ±0.25% accuracy at higher cost, consider the Honeywell TruStability HSC series, validating the pinout against the MPXV4006G footprint.

代替品との比較

パラメータ この製品 MPXV4006GC6U MPVZ5004G7U MPVZ5010G7U HSCDRRN001PD2A3
Package 8-DIP top port (0.550 in) 8-DIP top port (same) 8-SOP small outline 8-SOP small outline DIP through-hole (TruStability)
Brand STMicroelectronics STMicroelectronics STMicroelectronics / NXP STMicroelectronics / NXP Honeywell
Pressure Range (kPa) 0 to 6 0 to 6 0 to 4 0 to 10 0 to ±6.9 (±1 psi)
Output Span (V) 0.2 to 4.7 0.2 to 4.7 0.2 to 4.7 (1 V/kPa transfer) 0.2 to 4.7 (0.5 V/kPa transfer) ratiometric, varies with calibration
Supply Voltage (V) 5 5 5 5 3.3 or 5 (configurable)
Accuracy ±1.5 %VFSS (0-85 C) ±1.5 %VFSS (0-85 C) ±1.5 %VFSS ±2.5 %VFSS ±0.25 %FSS (higher precision)
Pressure Type Vented Gauge Vented Gauge Gauge Gauge Differential (configurable)

主な差別化要因

  • On-chip signal conditioning eliminates external op-amps (vs Honeywell HSCDRRN001PD2A3)
  • Top-port tube inlet matches medical spirometry plumbing (vs MPVZ5004G7U)
  • Industry-standard 0-6 kPa span matches 0-1 inch H2O (vs MPVZ5010G7U)

設計ノート

Decouple the VCC pin (pin 1) with a 100 nF ceramic capacitor placed within 5 mm of the package lead. The MPXV4006GC7U draws roughly 7 mA from 5 V and the on-chip ASIC is sensitive to supply ripple; a ferrule bead plus the 100 nF cap typically keeps noise below 5 mV on the analog output. Estimated: based on the typical 7 mA supply figure cited in the family datasheet. Avoid tying the analog return to a high-current digital ground to preserve ratiometric accuracy.

The MPXV4006GC7U is specified for dry, non-corrosive gases only. Never connect it directly to water, oils, or aggressive vapors - use a pneumatic isolator or hydrophobic filter membrane if your media is wet. The vented-gauge reference relies on the rear-vent opening; do not conformal-coat or pot the rear of the package, or the gauge will read incorrectly under barometric changes. Estimated: the rear-vent requirement is a documented family-level design rule.

Route the analog output (pin 2) through a low-impedance buffer (op-amp follower with input bias <1 nA) if the downstream ADC has input impedance below 100 kΩ. The sensor's output impedance can sag the reading on heavy ADC loads. Keep analog traces short and away from switching converter nodes; the ratiometric calibration assumes a clean 5 V rail. Place the part with the tube inlet pointing up to prevent condensation collection in the sensor cavity.

コンプライアンス情報

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
鉛フリー
Yes
ハロゲンフリー
Unknown
紛争鉱物
Compliant

RoHS and lead-free status confirmed via DigiKey product detail and NXP product page. Halogen-free status not explicitly listed; set to unknown. Not AEC-Q100 qualified; this is an industrial/consumer part.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPXV4006GC7U MPXV4006GC7U datasheet STMicroelectronics MPXV4006GC7U 0-6 kPa pressure sensor 5V analog vented gauge pressure sensor 8-DIP MPXV4006GC7U spirometer application MPXV4006GC7U vs MPVZ5004G7U MPXV4006GC7U drop-in replacement buy MPXV4006GC7U online MPXV4006GC7U pinout 8-DIP low pressure sensor HVAC variable air volume Honeywell TruStability equivalent for MPXV4006GC7U

関連部品&用語

STMicroelectronics NXP Semiconductors Honeywell MPXV4006GC7U MPXV4006GC6U MPVZ5004G7U MPVZ5010G7U HSCDRRN001PD2A3 piezoresistive pressure sensor pressure transducer vented gauge differential pressure MEMS sensor Wheatstone bridge ratiometric analog output DIP-8 package RoHS compliance VAV damper spirometer barometric pressure altitude sensor filter-clog detection on-chip signal conditioning temperature compensation
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示