SN65HVD07DR - 1 Mbps RS-485 Transceiver | Texas Instruments (Tape & Reel)
部品番号: SN65HVD07DR ✓ 生産中SN65HVD07DR 概要
An RS-485 transceiver is an interface IC that bridges a logic-level controller and a balanced, differential physical bus. The driver converts a single-ended digital signal into differential A and Y outputs, while the receiver converts differential bus voltage into a single-ended logic signal. As a half-duplex transceiver, it supports one physical communication path that can transmit or receive, but not both simultaneously. The SN65HVD07DR belongs to the broader transceiver and interface-IC hierarchy used for industrial automation, building controls, instrumentation, and other robust wired-data systems.
Key features include a 1 Mbps data rate, a fourth-eighth unit-load option, and support for as many as 256 nodes on the bus. Bus-pin electrostatic-discharge protection exceeds 16 kV using the human-body model. The driver includes controlled output slew rate, which limits the rate of differential voltage change and helps reduce unwanted bus transients. The three-state driver output can be disabled when the bus is not being driven, allowing multiple transmitters to share the same differential pair.
The high-output driver is the principal technical distinction within the SN65HVD family. Its differential output is designed to exceed the minimum output voltage required by ANSI TIA/EIA-485-A and ISO 8482E devices. This supports reliable communication when the bus presents a substantial load or when cable and termination arrangements reduce signal amplitude. The receiver operates from the same differential pair and includes receiver-side fail-safe behavior for open-circuit, short-circuit, and idle-bus conditions as described for the device family.
Typical applications include industrial RS-485 links, programmable-logic-controller equipment, building-automation controllers, factory-floor sensors, data-acquisition systems, and remote monitoring devices. The device can also be used in half-duplex multidrop networks where each node must disconnect its driver while the bus is idle. Designers should maintain compatible logic levels, provide correct bus termination, and verify the selected transceiver against the cable length, data rate, node count, and grounding arrangement.
A key design consideration is the shared A and Y bus conductors in half-duplex operation. The enable and receive-enable controls must be managed so that the local driver is enabled only while transmitting. Place the transceiver close to the bus connector and route the balanced pair as a differential pair to minimize common-mode noise and impedance discontinuities. The device supports operation from 4.5 V to 5.5 V, so system-level supply tolerance and transient requirements must be checked separately.
This page combines the manufacturer interface description with same-footprint family comparisons, application-specific design guidance, and a parameter-by-parameter evaluation of candidate transceivers. The comparisons are intended to accelerate initial device selection while making the remaining electrical and mechanical checks explicit for engineering review.
ドロップイン代替品: SN65HVD07DR — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: SN65HVD07DR (同一形状・フットプリント) — 相違点: Package, Operating Temperature, Product Type, Supply Voltage, Communication Mode.
SN65HVD05D
✅ ドロップイン価格はお問い合わせください
データシートを見る →SN75HVD07D
✅ ドロップイン📋 参考代替品(カタログ未掲載)
SN65HVD22D
✅ ドロップイン価格はお問い合わせください
データシートを見る →SN65HVD82D
✅ ドロップイン価格はお問い合わせください
データシートを見る →SN65LBC176DR
✅ ドロップイン✓ 在庫あり
$1.2727 / 個
データシートを見る →SN65HVD07DR 仕様
| Product Type | RS-485 half-duplex transceiver |
| Transceiver Configuration | 1 transmitter / 1 receiver |
| Maximum Data Rate | 1 Mbps |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Nominal Supply Voltage | 5 V |
| Communication Mode | Half duplex |
| Supported Standards | ANSI TIA/EIA-485-A and ISO 8482E |
| Driver Output State | Three-state differential output |
| Receiver Input | Differential input |
| Unit Load | 1/8 unit load |
| Maximum Bus Nodes | 256 nodes |
| Bus-Pin ESD Protection | Exceeds 16 kV HBM |
| Output Slew Rate | Controlled |
| 動作温度範囲 | -40 °C to 85 °C |
| パッケージ | 8-pin SOIC (D) |
| 実装タイプ | Surface mount |
SN65HVD07DR 8-pin soic (d) ピン配置ガイド
SN65HVD07DR (8-pin soic (d) パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: SN65HVD07DR.
詳細は データシート をご参照ください。
主な用途
SN65HVD07DR の用途: 6 件s: Industrial PLC and Controller Networks, Building Automation and HVAC Control, Factory Sensors and Remote Monitoring, Data-Acquisition and Test Equipment, Programmable Logic Controller Peripherals, General-Purpose Balanced Data Links.
Industrial PLC and Controller Networks
The SN65HVD07DR fits half-duplex RS-485 links between programmable-logic controllers, remote I/O modules, and factory-floor controllers because it supports data rates up to 1 Mbps from a 4.5 V to 5.5 V supply. Its high-output differential driver is intended for balanced buses operating under ANSI TIA/EIA-485-A and ISO 8482E system rules. The eighth-unit-load option supports as many as 256 nodes, which is useful for dense equipment buses. Controlled output slew rate helps limit fast bus transitions. Designers should still verify cable length, node loading, termination, grounding, and protection at each connector.
おすすめ
Building Automation and HVAC Control
The SN65HVD07DR is appropriate for building-control units, HVAC controllers, and room equipment that communicate over a shared balanced bus. The 1 Mbps capability provides margin for short, high-speed links, while the high-output driver supports reliable signaling across installed cable and termination networks. Its -40 °C to 85 °C operating range suits many industrial environments. Because multiple building controllers may share one A/Y pair, the three-state output must be disabled whenever a node is not transmitting. Validate the grounding strategy, cable routing, surge protection, and maximum node count before installation.
おすすめ
Factory Sensors and Remote Monitoring
The SN65HVD07DR can connect remote sensors, condition-monitoring units, and data-acquisition equipment to a controller over an RS-485 bus. The one-eighth unit-load characteristic allows up to 256 nodes, making it useful where numerous compact sensing devices share a multidrop network. Its differential receiver and driver improve noise immunity on balanced wiring, while controlled slew rate reduces fast output transitions. For long cable runs, keep the A and Y conductors as a close pair, place termination appropriately, and confirm that transceiver loading remains within the supported node count.
おすすめ
Data-Acquisition and Test Equipment
The SN65HVD07DR is suitable for laboratory and test equipment that must exchange commands or measurements with remote fixtures over a balanced bus. A 1 Mbps rate supports efficient transfer of short commands and data blocks, and the 8-pin SOIC package simplifies implementation on compact controller boards. The high-output driver can maintain usable differential amplitude in installed systems with suitable termination. Keep sensitive analog and reference circuitry away from the bus route, provide a stable interface ground, and use controlled driver enable timing to prevent multiple nodes from driving the bus simultaneously.
おすすめ
Programmable Logic Controller Peripherals
The SN65HVD07DR can provide the physical RS-485 layer beneath a programmable-logic-controller communication port. Its half-duplex architecture matches controllers that share one differential pair for command and response traffic. The three-state output allows the controller board to participate in a multidrop network without continuously driving the bus, while the high-output driver supports reliable communication over installed wiring. The interface must match the controller's 5 V logic levels, and the firmware must enforce directional control so the receiver remains usable while the driver is disabled.
おすすめ
General-Purpose Balanced Data Links
The SN65HVD07DR can be used in custom balanced data links whenever the endpoints require differential signaling and a shared half-duplex channel. Its 1 Mbps maximum rate, 5 V supply range, and high-output driver suit equipment that exchanges serialized control or status information. Unlike a single-ended interface, the differential A/Y connection provides a more robust path in electrically noisy installations when implemented with controlled impedance and proper grounding. Before designing a proprietary bus, verify receiver thresholds, fail-safe behavior, bus capacitance, termination, cable length, and interoperability with every connected equipment type.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: SN65HVD07DR — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | SN65HVD05D | SN75HVD07D | SN65HVD22D | SN65HVD82D | SN65LBC176D |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) |
主な差別化要因
- High-output differential driver (vs SN65LBC176D)
- One-eighth unit-load bus support (vs SN65HVD22D)
- 1 Mbps operation with controlled slew rate (vs SN65HVD82D)
- Dedicated high-output family placement (vs SN65HVD05D)
設計ノート
Place the SN65HVD07DR close to the bus connector and route A and Y as a controlled-impedance differential pair. Keep the pair over a continuous ground plane, minimize stubs to test points, and avoid sharing the route with switching-power or high-current traces. Put termination and common-mode components near the connector where practical, because long unmatched branches can increase reflections and common-mode noise.
Manage the three-state driver direction correctly in half-duplex operation. The driver must be disabled whenever the node is receiving or the bus is idle; otherwise, multiple connected nodes may contend and produce an invalid differential voltage. Use the enable and receive-enable inputs in the logic design so transitions cannot place the transmitter and receiver in conflicting states.
Provide the supply decoupling and grounding arrangement required by the manufacturer application guidance. Keep the 5 V return path short, place decoupling capacitance close to the device, and maintain a low-impedance connection between the transceiver ground and the interface reference ground. A solid ground reference is especially important when long cables expose the bus to common-mode voltage above the transceiver's local supply rails.
Use the controlled output slew rate to reduce fast differential transitions, but still verify radiated and conducted emissions because edge energy depends on cable length, load, termination, and layout. Avoid adding large snubber capacitors directly across the bus unless their effect on data integrity has been checked. External protection devices should be positioned near the connector and selected so they do not distort the receiver thresholds.
コンプライアンス情報
The operating temperature range is stated as -40 °C to 85 °C. RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive-qualification statements are not identified in the cited product information.