V375A48E600BN3 - 600W 48V Maxi Series Isolated DC-DC | Vicor
部品番号: V375A48E600BN3 ✓ 生産中| 数量 | 単価 | 小計 |
|---|---|---|
| 1 | $448.67 | $448.67 |
| 10 | $425 | $4,250.00 |
| 50 | $405 | $20,250.00 |
| 100 | $385 | $38,500.00 |
| 250 | $365 | $91,250.00 |
V375A48E600BN3 概要
A DC-DC converter module is a self-contained switched-mode power building block that converts one DC voltage to another, typically providing galvanic isolation between source and load. Within the broader taxonomy, this part is an intermediate-bus or distributed-bus converter (brick converter) within the power management IC and module family, optimized for 380V nominal rectified industrial bus rails. Its role is to step down high-voltage DC while delivering a regulated, isolated, low-voltage rail to downstream point-of-load converters or directly to system loads.
Key features include an input surge withstand rating of 500V for 100 ms, an output programmable from 10% to 110% of nominal (4.8V to 52.8V), regulation of ±0.25% from no load to full load, and a maximum output power of 600W. The module supports a wide operating temperature range of -10C to +100C at the baseplate. Its 425V-rated isolated topology provides reinforced safety isolation between the high-voltage input bus and the user-accessible low-voltage output.
Technically, the V375A48E600BN3 uses a proprietary zero-current-switching / zero-voltage-switching topology with Vicor's planar magnetic structure, achieving high efficiency and low EMI in a brick-format footprint. The E-grade variant denotes an enhanced-baseplate/through-hole package option designed for chassis-mount and conduction-cooled applications, with a 9-pin terminal layout for input, output, sense, trim, and enable functions.
Typical applications include industrial 380V rectified-bus power systems, factory automation, motor drives, high-voltage LED lighting, and railway/traction auxiliary power. The wide input range also makes it suitable for 400V-class EV traction auxiliary rails and renewable-energy inverter auxiliary supplies.
When designing with this module, ensure the source bus provides the inrush energy expected by the input capacitor bank and respect the baseplate temperature limits. Use Vicor's recommended input fuse, hold-up, and Pi-filter networks to meet surge-withstand and conducted EMI requirements.
This page synthesizes distributor pricing, drop-in Vicor Maxi-series alternatives, and practical design notes not consolidated in the manufacturer datasheet, giving engineers a faster path to part selection, sourcing, and EMC-ready layout.
ドロップイン代替品: V375A48E600BN3 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
クイック比較ツール — 並列比較する代替部品を選択:
V375A48C600B
✅ ドロップイン📋 参考代替品(カタログ未掲載)
V375A48C600BL
✅ ドロップイン📋 参考代替品(カタログ未掲載)
V375A48E600BL
✅ ドロップイン📋 参考代替品(カタログ未掲載)
V375A48T600BG
✅ ドロップイン📋 参考代替品(カタログ未掲載)
V375A48H600BG
✅ ドロップイン📋 参考代替品(カタログ未掲載)
V375A48M600BF
✅ ドロップイン📋 参考代替品(カタログ未掲載)
V375A48E600BN3 最大定格&電気的特性
| トポロジー | Isolated DC-DC converter module (Maxi brick) |
| 入力電圧範囲 | 250 V to 425 V DC |
| Input Surge Withstand | 500 V for 100 ms |
| Nominal Output Voltage | 48 V |
| 出力電圧範囲 | 4.8 V to 52.8 V (programmable 10% to 110%) |
| 最大出力電流 | 12.5 A |
| Maximum Output Power | 600 W |
| Output Power (Datasheet Alternate) | 400 W |
| Line/Load Regulation | +/-0.25% no load to full load |
| 動作温度 | -10 C to +100 C (baseplate) |
| パッケージ | Vicor Maxi brick, through-hole (9-pin, E-grade) |
| 実装タイプ | Through Hole |
V375A48E600BN3 vicor maxi brick, through-hole (9-pin, e-grade) ピン配置ガイド
V375A48E600BN3 (vicor maxi brick, through-hole (9-pin, e-grade) パッケージ) のピン配置。 このパワーデバイスは、ゲート、ドレイン、ソース端子を備えています。非極性パッケージの場合、正確なピン1の向きとフットプリントの詳細については、メーカーのデータシートを参照してください。主な用途には、電源設計、モータ駆動、負荷スイッチングがあります。
詳細なピン配置データはありません: V375A48E600BN3.
詳細は データシート をご参照ください。
主な用途
V375A48E600BN3 の用途: 7 件s: Industrial 380V Rectified-Bus Power System, Traction Auxiliary Power (Railway/EV), Renewable Inverter Auxiliary Supply, High-Voltage LED Lighting Driver Backbone, Medical Imaging Auxiliary Rail, Robotics and CNC Servo Drive Backplane, Server / Datacom 380V DC Distribution.
Industrial 380V Rectified-Bus Power System
The V375A48E600BN3 fits directly onto a 380V three-phase rectified DC bus (250-425 V) and converts to an isolated 48 V/12.5 A/600 W rail for downstream PLCs, industrial PCs, and motor-drive auxiliary supplies. Its 500 V/100 ms surge withstand absorbs capacitor re-charge transients and inductive bus ringing typical of long factory feeders. Compared with a discrete 600W switcher, this single Maxi brick delivers a 9-pin through-hole module with characterized EMC, simplifying UL/IEC 61800-3 compliance for industrial control cabinets.
おすすめ
Traction Auxiliary Power (Railway/EV)
In railway auxiliary converters and 400V-class EV traction auxiliary rails, the V375A48E600BN3's 250-425 V input window covers rectified catenary or HV battery feeds. It delivers an isolated 48 V rail for control electronics, lighting, and HVAC blowers at up to 600 W. The Maxi brick's reinforced isolation and -10 C to +100 C baseplate temperature range are characteristic of rolling-stock and e-mobility environments. Designers typically parallel two bricks for N+1 redundancy and to ride through brief input dropouts on catenary sections.
おすすめ
Renewable Inverter Auxiliary Supply
Solar inverters and wind converters use a 600-800 V DC intermediate bus from the MPPT stage; the V375A48E600BN3 takes that bus down to an isolated 48 V/12.5 A rail for gate drivers, fans, and SCADA communications. Its 600 W power class is well-matched to residential and small-commercial inverter auxiliary loads. The Maxi brick's 500 V transient withstand tolerates the inverter's switch-node ringing, and its 9-pin through-hole package simplifies chassis-mount thermal integration onto the inverter heatsink.
おすすめ
High-Voltage LED Lighting Driver Backbone
Architectural and horticultural LED fixtures that run from 380 V rectified mains benefit from a centralized 600 W DC-DC step-down brick driving a 48 V constant-voltage trunk to multiple LED drivers along the fixture. The V375A48E600BN3's 250-425 V input matches the rectified mains range exactly, and the 48 V trunk is the de-facto standard for constant-current LED drivers downstream. A single Maxi brick replaces a bulky 600 W discrete flyback with a 9-pin chassis-mount module, freeing design time for thermal and photometric optimization.
おすすめ
Medical Imaging Auxiliary Rail
MRI gradient amplifiers and CT scanner auxiliaries need an isolated, low-noise 48 V rail derived from a 380 V DC bus. The V375A48E600BN3 provides reinforced isolation between the high-voltage bus and the SELV user side, with +/-0.25% regulation supporting sensitive analog front-ends. Its 600 W capacity covers the auxiliary power budget of a single gradient or detector module. Engineers typically add external common-mode chokes and Pi-filters per Vicor's EMI reference to meet IEC 60601-1 system-level requirements.
おすすめ
Robotics and CNC Servo Drive Backplane
High-power CNC machines and 6-axis robots commonly run from a 600-700 V DC bus derived from rectified 3-phase mains. The V375A48E600BN3 converts this bus to an isolated 48 V/12.5 A rail for controller backplanes, I/O, and brake-release circuits. Its Maxi brick through-hole package simplifies chassis mounting into the machine's existing heat-sink structure, and 600 W covers the full auxiliary budget without paralleling. Industrial control designers value the brick's characterized EMC and surge performance for CE/UL industrial machinery compliance.
おすすめ
Server / Datacom 380V DC Distribution
Emerging 380V DC datacom distribution architectures (Open Compute, EU Code of Conduct) use the V375A48E600BN3 to step down a 380 V DC bus to an isolated 48 V/12.5 A feed for individual server sleds or PoE midspans. The brick's 425 V upper input covers the rectified 3-phase feed and the 250 V lower bound accommodates battery hold-up dips. Compared to AC-fed alternatives, a 380 V DC distribution with a Maxi brick eliminates one AC/DC stage per sled and improves end-to-end efficiency by 4-8%.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: V375A48E600BN3 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | V375A48C600B | V375A48C600BL | V375A48E600BL | V375A48T600BG | V375A48H600BG | V375A48M600BF |
|---|---|---|---|---|---|---|---|
| Brand | Vicor | Vicor | Vicor | Vicor | Vicor | Vicor | Vicor |
| Package | Vicor Maxi brick, through-hole (9-pin, E-grade) | Vicor Maxi brick, through-hole (9-pin) - same | Vicor Maxi brick, through-hole (9-pin) - same | Vicor Maxi brick, through-hole (9-pin) - same | Vicor Maxi brick, board-mount (9-pin) - close | Vicor Maxi brick, through-hole (9-pin) - same | Vicor Maxi brick, through-hole (9-pin) - same |
| Input Voltage Range | 250 V to 425 V | 250 V to 425 V | 250 V to 425 V | 250 V to 425 V | 250 V to 425 V | 250 V to 425 V | 250 V to 425 V |
| Nominal Output Voltage | 48 V | 48 V | 48 V | 48 V | 48 V | 48 V | 48 V |
| Output Current | 12.5 A | 12.5 A | 12.5 A | 12.5 A | 12.5 A | 12.5 A | 12.5 A |
| Maximum Output Power | 600 W | 600 W | 600 W | 600 W | 600 W | 600 W | 600 W |
| Mounting / Grade | Through-hole, E-grade | Through-hole, C-grade | Through-hole, C-grade long-lead | Through-hole, E-grade long-lead | Board-mount, T-grade | Through-hole, H-grade | Through-hole, M-grade |
| Operating Temperature (baseplate) | -10 C to +100 C | -10 C to +100 C | -10 C to +100 C | -10 C to +100 C | -10 C to +100 C | -10 C to +100 C | -10 C to +100 C |
主な差別化要因
- Single 9-pin Maxi brick replaces discrete 600W switcher + transformer + EMC circuit (vs V48A48E500BG3)
- Reinforced isolation and 500V/100ms surge withstand for hazardous-voltage buses (vs V24A12E300B)
- Programmable output 10% to 110% (4.8V to 52.8V) from a single module (vs V375A48C600B)
設計ノート
Estimated: At 600 W output and ~90% typical Vicor Maxi efficiency, internal dissipation is approximately 60-70 W. Mount the V375A48E600BN3 to a chassis or heatsink with sufficient thermal mass to keep the baseplate below +100 C under worst-case ambient. For convection-only designs, derate to 400-450 W; for forced-air or conduction-cooled chassis, full rated power is achievable. Apply a thin, uniform thermal interface material between baseplate and chassis for repeatable thermal resistance.
Use the Vicor-recommended PCB land pattern for the 9-pin Maxi brick (input/output pins on one side, sense/trim/enable on the other). Provide wide copper pours on input and output traces to carry 12.5 A continuous with less than 10 C rise, and keep input return and output return separated to minimize common-mode noise coupling. Place input fuse and Pi-filter components within 25 mm of the input pins to suppress the 500 V/100 ms surge event and conducted EMI from the switching stage.
Do not exceed the 425 V continuous or 500 V/100 ms surge input ratings - over-voltage on a Maxi brick is non-recoverable and not field-serviceable. Always wire +Sense/-Sense at the load, not at the brick's output pins, to remove distribution losses from the regulation loop. Use the Trim pin only within the documented 10-110% range and never float the Enable pin (tie high or low as appropriate). Verify that the upstream source can supply the brick's inrush current without tripping upstream protection.
Although the brick itself is characterized for EMC, the system-level EMI result depends on the input Pi-filter, output capacitance, and chassis grounding. Use Vicor's reference design Pi-filter (common-mode choke + X/Y capacitors) on the input to meet EN 55011/CISPR 11 Class A for industrial equipment and EN 55022 Class A for datacom. Place the input fuse after the Pi-filter to keep its inductance out of the filter's noise path. For Class B, add a second filter stage or shielding.
コンプライアンス情報
Explicit RoHS/REACH/AEC-Q100 status was not present in the verified distributor snippets; engineer should request the Vicor RoHS/REACH declaration letter directly for RoHS-restricted or automotive programs. AEC-Q100 is not applicable - Maxi bricks are industrial-grade modules not qualified to automotive reliability standards.