Analog Devices

AD53508JP - Dual-Channel 15.75V PMU IC | Analog Devices

부품 번호: AD53508JP ✓ 활성
4.75 V to 15.75 V Vdss Supported programmable mode Id 44-pin PLCC Package
MOQ: 1 |

AD53508JP 개요

The Analog Devices AD53508JP is a dual-channel parametric measurement unit (PMU) integrated circuit designed for semiconductor automatic test equipment. It combines two independently programmable measurement channels, a 4.75 V to 15.75 V supply range, and a 44-pin PLCC package measuring approximately 16.59 mm by 16.59 mm. Each channel can force a voltage while measuring current, force a current while measuring voltage, or integrate and hold a current value.

A parametric measurement unit is a specialized interface IC that connects an automated test system with a device under test. Within the test-system hierarchy, it sits between the tester controller and the DUT pin, converting force commands into analog outputs and returning measured current or voltage as feedback. The AD53508JP therefore functions as an interface circuit, measurement circuit, and precision driver within automatic test equipment.

Two measurement channels allow a tester to control or monitor two DUT pins in parallel. The device supports direct measurement of higher currents, while integration provides low-noise, high-accuracy measurement for very small currents. Programmable operating modes let the same channel perform force-and-measure functions, integrate a current value, or hold a measured result, reducing the need for separate external instrumentation paths.

The AD53508JP includes remote force and sense capability, allowing the measurement function to operate at the tester pin rather than only at the instrument connection point. This arrangement helps compensate for voltage drops in force and sense wiring, improving measurement accuracy where long test leads, socket contacts, or tester-board routing create meaningful resistance.

Typical uses include semiconductor ATE pin-parameter characterization, parametric process monitoring, leakage-current tests, force-and-measure bias applications, and board-level semiconductor validation. The dual-channel architecture is particularly useful for parallel measurements and controlled power-delivery tests where each DUT pin requires independently programmed forcing and sensing.

The primary design consideration is low-noise force-and-measure performance. Keep force and sense routing separated, use a low-noise analog ground strategy, and follow the manufacturer’s recommended bypass and layout practices. Confirm pin functions and the 44-pin PLCC footprint against the AD53508 datasheet before making PCB or fixture assignments.

This product page combines the manufacturer’s device description with package details, sourcing guidance, application analysis, and a strict assessment of replacement options. It distinguishes electrically equivalent same-family variants from mere packaging references so engineers can make board-level replacement decisions without assuming that a similar-looking catalog entry is automatically drop-in compatible.

드롭인 대체품: AD53508JP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

AD53508JS

✅ 드롭인
📦 44-pin PLCC
Same AD53508 family and 44-pin PLCC package; supply range remains 4.75 V to 15.75 V with 0 V difference, while exact temperature-grade differences require manufacturer-ordering-table confirmation

📋 참조 대체품 (카탈로그에 없음)

AD53508JP 사양

Product Type Dual-channel parametric measurement unit (PMU) interface IC
Number of Channels 2 channels
Supply Voltage Range 4.75 V to 15.75 V
Nominal Supply Voltage 5 V
패키지 44-pin PLCC
Package Dimensions 16.59 mm x 16.59 mm
Number of Terminals 44 terminals
Lead Pitch 1.27 mm
Terminal Form J-lead
Package Shape Square
동작 온도 범위 +25°C to +70°C
Moisture Sensitivity Level MSL 5
Force Voltage and Measure Current Supported programmable mode
Force Current and Measure Voltage Supported programmable mode
Current Integration Supported integration-and-hold mode
Remote Force and Sense Supported
Higher-Current Measurement Direct measurement supported
Very-Low-Current Measurement Integration method for low noise and high accuracy
실장 유형 Surface mount
RoHS Compliance Unknown
REACH Compliance Unknown

AD53508JP square 핀 구성 가이드

AD53508JP(square 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.

AD53508JP의 square 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: AD53508JP.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

AD53508JP 적합 용도: 6 애플리케이션s: Semiconductor Automatic Test Equipment, Semiconductor Leakage-Current Testing, Parametric Process Monitoring, Power-Delivery Characterization, Board-Level Semiconductor Validation, Analog and Mixed-Signal IC Test.

🏭

Semiconductor Automatic Test Equipment

The AD53508JP fits semiconductor ATE pin-parameter modules because it combines two programmable PMU channels with voltage-force/current-measure and current-force/voltage-measure modes. Each channel can be assigned to a separate DUT pin, allowing a tester to bias and observe two nodes during one parametric test sequence. Its 4.75 V to 15.75 V supply range supports conventional 5 V tester backplanes. Remote force and sense improves accuracy at the tester pin by reducing the effect of drops across wiring, sockets, and load-board traces.

🔬

Semiconductor Leakage-Current Testing

The AD53508JP is useful for leakage and low-current characterization because its programmable modes support integration for low-noise, high-accuracy measurement. A channel can integrate the current associated with a forced voltage and hold the resulting value for the test system, while higher-current conditions can use direct measurement. This dual approach lets one device cover a broader current range than a single measurement method. Settling time, integration interval, leakage floor, and fixture behavior should be characterized together for each resistance level.

📊

Parametric Process Monitoring

The AD53508JP can serve as the interface between a process-monitoring controller and a semiconductor structure under test. Programmable voltage or current forcing permits controlled bias conditions, while complementary current or voltage measurement observes the resulting response. Two channels enable simultaneous monitoring of related structures or sequential measurements without changing the force-and-measure architecture. The 44-pin PLCC format supports compact tester-channel layouts, but socket contact resistance and thermal conditions must be included when correlating results with process parameters.

⚡

Power-Delivery Characterization

The AD53508JP is appropriate for characterizing voltage-drop and current-delivery behavior in semiconductor packages and boards. Its voltage-force/current-measure mode applies a defined bias and determines the current response, while current-force/voltage-measure mode supports complementary tests. Remote force and sense is particularly valuable when the intended measurement point is the DUT pin and resistive paths lie between the tester channel and that pin. Calibration should include fixture parasitics and establish which portion of the measured drop belongs to the device versus the test path.

🖥️

Board-Level Semiconductor Validation

The AD53508JP can support board-level validation by providing programmable parametric access to semiconductor pins under functional test conditions. A tester can force a voltage and observe current, force current and observe voltage, or integrate and hold a low-current result. The dual-channel organization allows two DUT pins to be controlled or monitored in parallel, reducing fixture duplication. Because the package uses J-leaded PLCC construction, designers should verify socket availability, contact repeatability, handling procedures, and whether production testing will use sockets or direct soldering.

🎛️

Analog and Mixed-Signal IC Test

The AD53508JP is relevant to parametric testing of analog and mixed-signal integrated circuits where individual pins require controlled bias and current observation. The voltage-force/current-measure mode can evaluate input impedance and bias-dependent current, while current-force/voltage-measure can support output-impedance and compliance measurements. Integrating a current measurement can improve the signal-to-noise ratio for small values. The tester software should account for channel settling, integration time, relay timing, and the remote force/sense path when establishing production measurement limits.

추천 제품 요약

AD53508JS Same-family 44-pin PLCC parametric measurement device 사용처: Semiconductor Automatic Test Equipment, Semiconductor Leakage-Current Testing, Parametric Process Monitoring, Power-Delivery Characterization, Board-Level Semiconductor Validation, Analog and Mixed-Signal IC Test
What is the AD53508JP?
The AD53508JP is a dual-channel parametric measurement unit designed for semiconductor automatic test equipment. According to the Analog Devices product page, each channel can force voltage and measure current, force current and measure voltage, or integrate and hold a current value. The IC combines two measurement channels, remote force and sense, direct higher-current measurement, and integration-based low-current measurement in a 44-pin PLCC package.
What is the supply voltage range of AD53508JP?
The AD53508JP operates from 4.75 V to 15.75 V. The Analog Devices product documentation identifies the device as a dual-channel parametric measurement circuit for semiconductor automatic test equipment, while the AD53508JP catalog description identifies a nominal 5 V supply. Both channels operate within the same device-level supply range, allowing the PMU to support common ATE power architectures.
Where can I download the AD53508JP datasheet PDF?
The official AD53508 datasheet and product information are available from Analog Devices at the AD53508 product page. Use the manufacturer’s pin-description table and electrical-characteristics section when assigning the 44 PLCC terminals, selecting bypass capacitors, or designing the surrounding force-and-measure circuitry. The AD53508JP ordering suffix identifies the specific package configuration, so confirm that suffix before releasing a PCB layout.
Where can I find the AD53508JP pinout?
The AD53508JP pinout is documented in the Analog Devices AD53508 datasheet. The device uses a 44-pin J-lead PLCC package with a 1.27 mm lead pitch and an approximately 16.59 mm by 16.59 mm body. Assign each force, sense, measurement, reference, control, supply, and ground connection from the manufacturer’s pin-description table rather than inferring positions from a distributor category image.
How does the AD53508JP perform force-and-measure testing?
The AD53508JP can force a selected voltage and measure the resulting current, or force a current and measure the resulting voltage. According to the Analog Devices product page, programmable modes also allow a channel to integrate and hold a current value. This flexibility lets one PMU channel perform different parametric tests while direct measurement handles higher currents and integration improves accuracy for very low currents.
Why is remote force and sense important in an ATE PMU?
Remote force and sense improves accuracy by placing the measurement reference at the DUT pin rather than only at the instrument connection. Voltage drops in tester wiring, sockets, and board traces can otherwise appear as part of the DUT voltage. According to the Analog Devices AD53508 product description, the remote force/sense capability helps ensure accuracy at the tester pin during programmed parametric measurements.
What are the main AD53508JP specifications?
The AD53508JP is a 2-channel parametric measurement IC with a 4.75 V to 15.75 V supply range and a 44-pin PLCC package. Its key functions include voltage-force/current-measure, current-force/voltage-measure, current integration and hold, direct higher-current measurement, and remote force and sense. The package measures approximately 16.59 mm by 16.59 mm and uses J-leads on a 1.27 mm pitch.
Is AD53508JP suitable for semiconductor leakage-current testing?
The AD53508JP is suitable for low-current parametric testing because its programmable integration mode is intended to obtain low noise and high accuracy. The Analog Devices product page states that higher currents can be measured directly while very low currents use integration. The appropriate operating mode, integration interval, settling time, and external circuit configuration should be selected together for the leakage range under evaluation.
What is the AD53508JP package and mounting style?
The AD53508JP is packaged in a 44-pin PLCC with J-leads, a 1.27 mm lead pitch, and an approximately 16.59 mm by 16.59 mm body. The catalog description identifies it as a surface-mount package. Although PLCC is a leaded surface-mount format, the J-leads must be inspected for coplanarity, cleaning, and handling before the device is inserted into a test socket or soldered.
What is the best drop-in replacement for AD53508JP?
AD53508JS is the closest identified same-family option for evaluating as a drop-in replacement for AD53508JP. Both belong to the AD53508 dual-channel PMU family and use the 44-lead PLCC platform. The manufacturer datasheet should still be checked for temperature grade, ordering suffix, pin-function revisions, and production configuration before substitution is approved. Packaging-only reel or tape variants are not treated as distinct engineering alternatives.
Can AD53508JS replace AD53508JP on the same PCB?
AD53508JS can be considered for a same-footprint replacement review because it is identified as a related AD53508 family member in the 44-lead PLCC ecosystem. A final drop-in decision requires checking the pin table, electrical limits, temperature grade, and ordering options in the Analog Devices datasheet. Do not approve the substitution solely from the shared package family or from a distributor’s similarity label.
AD53508JP vs AD53508JS: which one should I choose?
Choose AD53508JP when the specified AD53508JP ordering configuration has been validated for the target tester platform and production environment. Consider AD53508JS when its exact temperature grade, lifecycle status, and electrical limits match the required ATE application. Both are associated with the same dual-channel 44-pin PLCC family, but a final comparison must use the manufacturer’s ordering table rather than package similarity alone.
When should I choose AD53508JP instead of a generic ATE interface IC?
Choose AD53508JP when the test system needs an integrated dual-channel PMU that can force and measure both voltage and current. Its programmable modes, integration-and-hold operation, direct higher-current measurement, and remote force/sense architecture address instrument-level measurement functions within one specialized interface IC. A generic interface IC may be appropriate for simpler signal routing, but it does not inherently provide these parametric measurement modes.
Is AD53508JP suitable for ATE and automated semiconductor test?
The AD53508JP is specifically designed for semiconductor automatic test equipment. Its two programmable channels can force voltage or current and measure the complementary electrical quantity, while remote force and sense supports accuracy at the tester pin. This makes the device well matched to parametric pin tests, leakage measurements, controlled bias checks, and validation systems that require programmable DUT-interface functions.
Where can I buy AD53508JP and what is its lead time?
Use the Request a Quote form on this page to ask for AD53508JP availability, current unit pricing, minimum order quantity, and production lead time. The form allows the request to be matched to the exact AD53508JP ordering suffix and package rather than a broader AD53508 family listing. Confirm packaging, date-code requirements, and traceability when submitting the sourcing request.
What is the price of AD53508JP and is it in stock?
The current AD53508JP price and stock status should be confirmed through the Request a Quote form on this page. The form accepts the exact manufacturer part number, so the response can account for the 44-pin PLCC configuration and required delivery quantity. Use the same form to request volume pricing, scheduled deliveries, and documentation appropriate for your production program.
Which AD53508 equivalent should engineers evaluate for a drop-in redesign?
AD53508JS is the principal Analog Devices same-family candidate to evaluate because it is identified with the 44-lead PLCC AD53508 family. No distinct cross-brand equivalent was identified for the exact 44-pin force-and-measure pinout. Engineers should therefore compare AD53508JS against the manufacturer ordering information and verify the complete pin, temperature, and lifecycle requirements before approving it as a drop-in replacement.

엔지니어링 참조 데이터: AD53508JP — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose AD53508JP when the ATE channel design specifically calls for the AD53508 dual-channel PMU in a 44-pin PLCC package. Its programmable voltage-force/current-measure modes, current-force/voltage-measure modes, integration-and-hold operation, and remote force/sense architecture make it suitable for leakage, bias, impedance, and power-delivery characterization. Consider AD53508JS when its exact ordering configuration, temperature grade, and lifecycle status satisfy the production requirement; its shared family and package make it the primary same-family replacement candidate. Confirm the complete pin table and electrical limits before substitution. A generic interface IC is appropriate only when the design does not require integrated PMU functionality, because it may require separate force sources, measurement converters, relays, and external control logic.

대체품과의 비교

파라미터 이 제품 AD53508JS
Brand Analog Devices Analog Devices
Package 44-pin PLCC 44-pin PLCC
Product Type Dual-channel parametric measurement unit AD53508-family dual-channel parametric measurement device
Number of Channels 2 channels 2 channels
Supply Voltage Range 4.75 V to 15.75 V 4.75 V to 15.75 V
Voltage Force and Current Measure Supported Supported
Current Force and Voltage Measure Supported Supported
Current Integration and Hold Supported Supported
Remote Force and Sense Supported Supported

주요 차별점

  • Two programmable channels in one PMU package (vs AD53508JS)
  • Voltage and current force-measure modes in the same channel (vs AD53508JS)
  • Remote force and sense accuracy support (vs AD53508JS)

설계 노트

Route force and sense conductors as separate paths from the AD53508JP to the DUT pin. Keep the sense return close to the force output and minimize shared copper resistance so remote force/sense can correct for voltage drops in the fixture and load board. Use a single ground reference for the analog measurement return, and inspect the manufacturer’s force-and-sense connection diagram before assigning tester connectors.

Do not treat the AD53508JP as a general-purpose precision ADC or regulator. Each channel is intended for programmed parametric force-and-measure operation, and the test software must coordinate the force value, measurement mode, integration interval, settling delay, and range. Allowing an unsupported state or measuring before the channel settles can create readings that reflect timing or overload behavior rather than the DUT.

The 44-pin PLCC package can conduct heat through its leads and socket contacts, but the tester fixture still determines the effective thermal environment. Keep forced current and dissipation within the manufacturer’s operating limits, verify socket contact resistance, and avoid placing the package adjacent to a high-temperature source without airflow. Monitor junction and board temperatures during long force-measure sequences rather than relying on ambient temperature alone.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

The AD53508 is an industrial test-equipment interface IC; no explicit automotive qualification is listed. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer’s compliance documentation.

관련 검색

AD53508JP datasheet AD53508JP pinout AD53508JP datasheet pdf AD53508JP schematic AD53508JP equivalent AD53508JP replacement AD53508JP cross reference AD53508JP vs AD53508JS AD53508JP 44 pin PLCC AD53508JP parametric measurement unit Analog Devices AD53508JP AD53508JP price AD53508JP stock AD53508JP ATE application AD53508JP remote force sense

관련 부품 & 용어

Analog Devices AD53508JP AD53508JS AD53508 dual-channel parametric measurement unit PMU parametric measurement circuit semiconductor automatic test equipment ATE device under test DUT voltage force current force current integration remote force and sense leakage-current measurement power-delivery characterization 44-pin PLCC J-lead 1.27 mm lead pitch Analog signal conditioning Interface ICs surface-mount package process monitoring
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기