AD621BRZ-R7 - Low-Power Instrumentation Amplifier | Analog Devices
부품 번호: AD621BRZ-R7 ✓ 활성AD621BRZ-R7 개요
An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals superimposed on a large common-mode voltage. Its internal signal path amplifies the difference between two inputs while rejecting common-mode noise. The AD621 belongs to the instrumentation-amplifier hierarchy within amplifier ICs and analog signal-chain devices, with the fixed gain of 1 making it particularly useful as a precision front end where subsequent stages perform the primary gain function.
The AD621BRZ-R7 combines an 800 kHz 3 dB bandwidth with a 1.2 V/µs slew rate. Its specified common-mode rejection ratio is 110 dB, while the input bias current is 500 pA. The AD621BNZ comparison identifies 120 dB CMRR and 1 nA input bias current for that variant, creating a clear distinction between the original AD621BRZ-R7 and the higher-CMRR grade. The original device is also identified as a low-cost, low-power, high-accuracy instrumentation amplifier.
Internally, the AD621 provides a fixed gain of 1 and uses resistor-based gain setting to control offset and gain drift. This architecture avoids the need for an external feedback network while maintaining the noise, common-mode rejection, and bias characteristics required by precision measurement systems. The 8-pin SOIC package also makes the device practical for conventional surface-mount assembly and compact analog boards.
Typical applications include Wheatstone bridge sensing, pressure and load-cell signal conditioning, low-level differential measurement, biomedical instrumentation, and precision industrial acquisition. The combination of low power, low drift, 110 dB CMRR, and 800 kHz bandwidth is useful when the sensor signal is small and the surrounding system contains switching noise or substantial common-mode voltage.
For a new design, verify the exact gain configuration, supply polarity, common-mode range, output swing, and input/output reference arrangement against the manufacturer datasheet. Place input and reference resistors close to the device, provide normal input-bias-current paths for source-impedance balance, and use a quiet reference arrangement when gain accuracy is important.
This page combines manufacturer-device identification, package and performance details, drop-in replacement analysis, comparison parameters, and practical design guidance for engineers evaluating the AD621BRZ-R7 in precision signal-chain applications.
드롭인 대체품: AD621BRZ-R7 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: AD621BRZ-R7 (동일 폼 팩터 및 풋프린트) — 차이점: Package, Common-Mode Rejection Ratio, Gain, Slew Rate, Product Type.
AD621BNZ
✅ 드롭인가격 문의
데이터시트 보기 →AD621AR
✅ 드롭인가격 문의
데이터시트 보기 →AD627BRZ
✅ 드롭인가격 문의
데이터시트 보기 →AD628ARZ
✅ 드롭인가격 문의
데이터시트 보기 →AD629BRZ
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →AD821BRZ
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
AD621BRZ-R7 최대 정격 & 전기적 특성
| Product Type | Single-channel instrumentation amplifier |
| Gain | 1 V/V |
| Number of Circuits | 1 circuit |
| 패키지 | 8-pin SOIC |
| 공급 전압 | ±18 V |
| 3 dB Bandwidth | 800 kHz |
| Slew Rate | 1.2 V/µs |
| Common-Mode Rejection Ratio | 110 dB |
| Input Bias Current | 500 pA |
| 실장 유형 | Surface mount |
| ESD Protection | Yes |
| RoHS 상태 | Compliant |
AD621BRZ-R7 8-pin soic 핀 구성 가이드
AD621BRZ-R7(8-pin soic 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: AD621BRZ-R7.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
AD621BRZ-R7 적합 용도: 6 애플리케이션s: Wheatstone Bridge Sensor Interface, Biomedical Signal Conditioning, Precision Load-Cell Measurement, Current-Shunt Amplification, Industrial Pressure Transmitter, Test and Measurement Front End.
Wheatstone Bridge Sensor Interface
The AD621BRZ-R7 fits a Wheatstone bridge front end where the wanted signal is the small differential voltage created by resistance changes while a larger voltage appears across the bridge. Its fixed gain of 1 V/V preserves that differential signal for subsequent amplification, while the documented 110 dB CMRR helps reject common-mode voltage and coupled noise. The 800 kHz bandwidth supports pressure, load-cell, and position-sensing systems without requiring a high-speed amplifier. Designers should calculate the bridge excitation, allowable input common-mode voltage, reference configuration, and downstream gain before finalizing the circuit.
추천
Biomedical Signal Conditioning
The AD621BRZ-R7 can serve as the first differential stage for low-level biomedical electrodes when electrode offset is small but common-mode voltage is significant. Its 500 pA input bias current limits disturbance of high-impedance sources, and its 110 dB CMRR improves rejection of mains-coupled and physiologically induced common-mode signals. The fixed gain of 1 keeps the stage suitable for controlled amplification and filtering downstream. A medical design must still validate input protection, patient leakage limits, electrode DC offsets, noise requirements, and applicable safety rules beyond the component datasheet.
추천
Precision Load-Cell Measurement
The AD621BRZ-R7 is appropriate for load-cell and force-transducer measurements that benefit from low gain drift and high common-mode rejection. With a gain of 1 V/V, the device can preserve the bridge differential while providing the initial common-mode rejection and signal conditioning needed before amplification or conversion. Its 800 kHz bandwidth is ample for many static and moderately dynamic weighing systems, and its 1.2 V/µs slew rate supports the resulting signal path. Designers should confirm bridge excitation limits, output range, reference behavior, and thermal drift in the complete measurement chain.
추천
Current-Shunt Amplification
The AD621BRZ-R7 can provide differential current measurement when a shunt produces a small voltage across a common-mode supply rail. Its 110 dB CMRR reduces the effect of supply variation on the measured differential, while 500 pA input bias current is favorable for higher-impedance sensing arrangements. The fixed unity gain makes it useful when later stages require the original shunt signal. Before implementation, verify the shunt placement, input common-mode range, output swing around the system reference, amplifier stability with source impedance, and whether a dedicated current-sense amplifier would provide a simpler solution.
추천
Industrial Pressure Transmitter
The AD621BRZ-R7 is suitable for the input stage of an industrial pressure transmitter where a bridge or resistive sensor produces a small differential signal. The 800 kHz bandwidth allows the stage to accommodate practical sensor dynamics, and the 110 dB CMRR helps reject noise found on long industrial wiring. Because the AD621BRZ-R7 has a fixed gain of 1 V/V, system scaling is handled by later stages that can also provide calibration and output conversion. Engineering validation should include surge and transient protection, sensor excitation noise, reference accuracy, and the permitted input common-mode range.
추천
Test and Measurement Front End
The AD621BRZ-R7 can serve as the differential input stage of a precision test and measurement system when a small sensor signal must be extracted from an elevated common-mode voltage. Its 500 pA input bias current minimizes loading on high-impedance probes, and its 110 dB CMRR improves rejection of common-mode interference. The 800 kHz bandwidth supports general-purpose instrumentation rather than only static measurements. For bench and factory equipment, engineers should account for connector protection, input-referred noise, reference stability, channel isolation, settling time, and calibration drift across the complete measurement path.
추천
추천 제품 요약
엔지니어링 참조 데이터: AD621BRZ-R7 — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | AD621BNZ | AD621AR | AD627BRZ | AD628ARZ | AD629BRZ |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
주요 차별점
- Lower input bias current than the higher-CMRR AD621BNZ (vs AD621BNZ)
- Same published dynamic performance as AD621AR (vs AD621AR)
- Fixed gain of 1 supports signal-preserving front-end architecture (vs AD627BRZ)
설계 노트
Use the manufacturer pin-description table to assign the 8-pin SOIC connections and preserve the documented input, output, reference, and supply topology. Place the device close to the sensor or bridge so that differential input traces remain short and matched. Route the two inputs as a pair, keep reference routing symmetrical, and avoid placing high-current or switching paths beneath the sensitive input nodes.
Do not assume that every 8-pin SOIC instrumentation amplifier is pin-compatible with the AD621BRZ-R7. Gain-setting resistors, reference pins, input polarity, and supply pins can differ among AD621, AD627, AD628, AD629, and AD821 devices. Before substituting an alternative, compare every pin name and function, then verify gain, common-mode range, output swing, and stability in the exact application circuit.
The documented 800 kHz bandwidth makes the AD621BRZ-R7 suitable for many sensor signals, but the complete front end must preserve low-noise behavior. Use short input traces, appropriate source impedances, and stable reference connections. If a higher-RMS-gain stage follows the unity-gain device, calculate the combined noise and bandwidth rather than assuming that the instrumentation amplifier provides the final system gain.
Confirm the actual power-supply voltage, output swing, and reference arrangement against the AD621 datasheet before enabling the circuit. The ±18 V comparison value identifies the published supply range, not guaranteed output headroom. Add local bypass capacitance close to the supply pins, maintain a low-impedance ground return, and prevent output saturation by checking the expected signal range before power-up.
규정 준수 정보
RoHS-compliant status is associated with the AD621 instrumentation-amplifier listing. No specific REACH, lead-free, halogen-free, conflict-minerals, or automotive-qualification statement was identified for the exact MPN.