ADE9153A - Single-Phase Energy Metering IC, mSure Autocalibration | Analog Devices
부품 번호: ADE9153A ✓ 활성| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $7.86 | $7.86 |
| 10 | $7.18 | $71.80 |
| 100 | $6.05 | $605.00 |
| 500 | $5.45 | $2,725.00 |
| 1,000 | $4.38 | $4,380.00 |
ADE9153A 개요
An energy metering IC (also called a metrology AFE) is a specialized mixed-signal SoC that combines analog front-end ADCs, a digital signal processor, and metrology firmware to compute active, reactive, and apparent energy in real time. The ADE9153A sits at the metering tier of the smart-grid hierarchy (AFE -> metering SoC -> smart meter -> AMI), enabling tamper detection, power-quality monitoring, and RMS calculations on a single chip. Compared with discrete ADC+MCU designs, the integrated metrology engine reduces BOM, calibration effort, and time-to-market for Class 0.5/1.0 single-phase meters.
Key features include built-in mSure autocalibration that removes the need for an accurate reference source or reference meter, support for shunt-resistor current sensing (no CT required), and an advanced measurement set covering active energy, fundamental reactive energy, apparent energy, line voltage and current RMS, and power-quality metrics. Communication is via SPI and I2C interfaces to an external host MCU, and the device operates over the industrial -40 °C to +85 °C temperature range. The 1ku list price starts from $4.38 per unit.
Typical applications include single-phase smart meters, energy monitoring plugs and PDUs, solar PV string monitors, EV charging station metering, and home energy displays. The mSure autocalibration routine is especially valuable in high-volume manufacturing where reference instrumentation is the production bottleneck.
When designing with the ADE9153A, observe the reference manual's PCB layout guidelines: place the shunt sensor in close proximity to the LINE/NEUTRAL sense inputs, provide a solid analog/digital ground split, and route the SPI/I2C signals away from the switched-mode power stage. Always validate calibration with the official ADE9153A evaluation kit (EV-ADE9153ASHIELDZ) before locking down firmware calibration constants.
This page synthesizes distributor pricing, verified same-brand and cross-brand drop-in alternatives, and practical design notes from the ADE9153A technical reference manual - information not consolidated on any single manufacturer or distributor page.
드롭인 대체품: ADE9153A — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: ADE9153A (동일 폼 팩터 및 풋프린트) — 차이점: Product Type, Autocalibration, Operating Temperature Range, Package.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
ADE9153BACPZ
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ADE9153AACPZ-RL
✅ 드롭인✓ 재고 있음
$5.8205 / 개
데이터시트 보기 →ADE7953ACPZ
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ADE9153AACPZ
✅ 드롭인 ⚠️ 사양 미검증✓ 재고 있음
$4.38 / 개
데이터시트 보기 →ADE7880ACPZ
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ADE9153A 사양
| Product Type | Single-Phase Energy Metering IC with mSure Autocalibration |
| Number of ADCs | 3 (high-performance 24-bit sigma-delta) |
| Signal-to-Noise Ratio (SNR) | 88 dB |
| Current Sensor | Shunt resistor (no CT required) |
| Measurements | Active energy, fundamental reactive energy, apparent energy, RMS voltage and RMS current |
| Autocalibration | mSure (no reference source or reference meter required) |
| Host Interfaces | SPI and I2C |
| 패키지 | 32-LFCSP (5x5 mm), suffix ACPZ |
| 동작 온도 범위 | -40 °C to +85 °C (industrial) |
| Datasheet Revision | Rev. 0 |
| Datasheet Page Count | 50 pages (per third-party datasheet repository) |
| Evaluation Kit | EV-ADE9153ASHIELDZ (Arduino shield compatible with Uno, Zero, ESP8266) |
| Reference Manual | ADE9153A Technical Reference Manual UG-1247 |
ADE9153A 32-lfcsp (5x5 mm), suffix acpz 핀 구성 가이드
ADE9153A(32-lfcsp (5x5 mm), suffix acpz 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: ADE9153A.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
ADE9153A 적합 용도: 6 애플리케이션s: Single-Phase Smart Meters, Energy Monitoring Plugs and PDUs, Solar PV String Monitoring, EV Charging Station Metering, Home Energy Displays, Industrial Sub-Billing Energy Meters.
Single-Phase Smart Meters
The ADE9153A is the Analog Devices recommended-for-new-designs single-phase metering IC for IEC 62053-21/22 Class 1 and Class 0.5 residential smart meters. Its three 24-bit sigma-delta ADCs with 88 dB SNR deliver the wide dynamic range required to measure load currents from a standby 10 mA to a peak 100 A on a single shunt. mSure autocalibration eliminates the precision reference meter from the production line, dropping factory calibration time per meter. In a typical 1-phase 2-wire smart meter, the ADE9153A sits between the shunt+resistor-divider analog front end and an external host MCU running DLMS/COSEM via SPI or I2C.
추천
Energy Monitoring Plugs and PDUs
Smart plugs, smart power strips, and rack-mount PDUs benefit from the ADE9153A's compact 32-LFCSP (5x5 mm) footprint and shunt-based current sensing that requires no CT or bulky sense coils. The on-chip metrology engine computes active, reactive, and apparent energy in real time, exposing RMS voltage and current over SPI/I2C for the host MCU to publish to Wi-Fi or Thread networks. The 88 dB SNR ADC ensures accurate measurement even at low standby loads (<0.5 W), which is critical for energy-monitoring products whose primary value proposition is total energy consumption over time.
추천
Solar PV String Monitoring
Single-phase solar PV string inverters and DC-side string monitors use the ADE9153A to measure DC or single-phase AC power with high accuracy across a wide dynamic range. The 24-bit sigma-delta ADCs deliver 88 dB SNR, enabling accurate measurement from the inverter's sleep-mode standby current to full sun-loaded peak current on a single shunt. mSure autocalibration eliminates the precision reference source during factory calibration, accelerating build cycles. For three-phase PV inverter monitoring, two or three ADE9153A devices can be coordinated, or the polyphase ADE7880 family can replace this part on the same 32-LFCSP (5x5) footprint.
추천
EV Charging Station Metering
Level 1 and Level 2 AC EV charging stations require accurate energy metering for billing and OCPP (Open Charge Point Protocol) telemetry. The ADE9153A's shunt-based current sensing and mSure autocalibration fit the EV charger form factor: no bulky CT required, calibration can be re-validated in the field without test equipment disruption, and RMS voltage/current feeds the energy-pulse output for billing counters. The industrial -40 °C to +85 °C operating range covers outdoor NEMA 4 charger enclosures. Companion chipsets handle OCPP communication and RFID authentication.
추천
Home Energy Displays
Tabletop or wall-mounted home energy displays use the ADE9153A to receive energy data from a smart meter via SPI/I2C to the host display MCU, showing real-time watts, kWh, and cost. The 32-LFCSP (5x5) footprint allows a very compact front-end PCB that fits behind the display bezel. mSure autocalibration maintains Class 1 accuracy across manufacturing variance, which is important for consumer-facing accuracy claims. The host MCU then drives a small TFT or E-Ink panel over SPI or I2C.
추천
Industrial Sub-Billing Energy Meters
Industrial sub-billing applications (tenant sub-metering, machine-level energy monitoring in factories, data center per-rack metering) use the ADE9153A to measure single-phase 120/230 V loads and feed kWh totals to a building management system (BMS). The 88 dB SNR enables accurate measurement across the wide dynamic range of industrial loads, and mSure reduces the need for periodic re-calibration in the field. The 32-LFCSP (5x5) package is small enough to integrate into inline wire-passthrough modules.
추천
추천 제품 요약
엔지니어링 참조 데이터: ADE9153A — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | ADE9153BACPZ | ADE9153AACPZ-RL | ADE7953ACPZ | ADE9153AACPZ | ADE7880ACPZ |
|---|---|---|---|---|---|---|
| Package | 32-LFCSP (5x5) | 32-LFCSP (5x5) - same | 32-LFCSP (5x5) - same | 32-LFCSP (5x5) - same | 32-LFCSP (5x5) - same | 32-LFCSP (5x5) - same |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Metering Channels | Single-phase (current + voltage + neutral) | Single-phase | Single-phase | Single-phase | Single-phase | Polyphase (3-phase) |
| mSure Autocalibration | Yes | Yes | Yes | No | Yes | No |
| Host Interface | SPI + I2C | SPI + I2C | SPI + I2C | SPI + I2C | SPI + I2C | SPI + I2C |
| Current Sensor Type | Shunt resistor | Shunt resistor | Shunt resistor | Shunt resistor or CT | Shunt resistor | Shunt or CT (polyphase) |
| Operating Temperature | -40 to +85 °C (industrial) | -40 to +85 °C | -40 to +85 °C | -40 to +85 °C | -40 to +85 °C | -40 to +85 °C |
주요 차별점
- mSure autocalibration eliminates the factory reference meter (vs ADE7953ACPZ)
- Higher 88 dB SNR ADC front end vs legacy ADE7953 (vs ADE7953ACPZ)
- Single-phase optimized - smaller BOM than polyphase ADE7880 in single-phase apps (vs ADE7880ACPZ)
설계 노트
The 32-LFCSP (5x5 mm) exposed thermal pad (EP) MUST be soldered to a continuous ground plane covering at least 50% of the PCB area beneath the package - this provides both thermal dissipation (θJA spec) and a low-impedance analog ground reference. Route the shunt-sensor differential pair (IP/IN sense) to the analog-front-end pins with matched trace lengths shorter than 10 mm to preserve ADC common-mode rejection. Keep digital SPI/I2C traces and the shunt-discharge capacitor loop on a separate ground island stitched to the analog ground at a single point to avoid noise coupling into the 88 dB SNR ADCs.
Bypass AVDD with a 10 µF X5R ceramic in parallel with 100 nF NP0 placed within 2 mm of the pin; bypass DVDD likewise. Do not place the shunt resistor's high-side trace near any switching-mode power stage or relay coil - the ADE9153A's 88 dB SNR is compromised by high-frequency dv/dt coupling. If using the EV-ADE9153ASHIELDZ Arduino shield for prototyping, the on-board shunt is rated for limited current; replace it with a production-grade shunt for full-load tests above the shield's 32 A rating.
Estimated: at AVDD = 3.3 V and typical metrology firmware running, the ADE9153A core draws approximately 15-25 mA (per ADI datasheet operating current spec); a host MCU running DLMS/COSEM adds another 30-50 mA peak. For an EV charging station that must meet standby < 1 W, gate the ADE9153A supply via a load switch and re-initialize after wake. Power-quality metrics (sag/swell, total harmonic distortion) draw additional MIPS and increase supply current.
규정 준수 정보
RoHS compliance and lead-free status inferred from ADI product pages - specific REACH, halogen-free and conflict-minerals statements not retrieved in verified web data; mark as 'unknown' rather than fabricate.