ADE9153A 概述

The Analog Devices ADE9153A is a highly accurate single-phase energy metering IC with built-in mSure autocalibration, packaged in a 32-lead LFCSP (5x5 mm) and targeting shunt-based residential and industrial metering applications. The device integrates three high-performance 24-bit sigma-delta ADCs delivering 88 dB signal-to-noise ratio (SNR) for accurate line voltage and current sensing across a wide dynamic range. It is recommended for new designs and replaces the earlier ADE7953 as the flagship single-phase metering platform in the ADI energy family.

An energy metering IC (also called a metrology AFE) is a specialized mixed-signal SoC that combines analog front-end ADCs, a digital signal processor, and metrology firmware to compute active, reactive, and apparent energy in real time. The ADE9153A sits at the metering tier of the smart-grid hierarchy (AFE -> metering SoC -> smart meter -> AMI), enabling tamper detection, power-quality monitoring, and RMS calculations on a single chip. Compared with discrete ADC+MCU designs, the integrated metrology engine reduces BOM, calibration effort, and time-to-market for Class 0.5/1.0 single-phase meters.

Key features include built-in mSure autocalibration that removes the need for an accurate reference source or reference meter, support for shunt-resistor current sensing (no CT required), and an advanced measurement set covering active energy, fundamental reactive energy, apparent energy, line voltage and current RMS, and power-quality metrics. Communication is via SPI and I2C interfaces to an external host MCU, and the device operates over the industrial -40 °C to +85 °C temperature range. The 1ku list price starts from $4.38 per unit.

Typical applications include single-phase smart meters, energy monitoring plugs and PDUs, solar PV string monitors, EV charging station metering, and home energy displays. The mSure autocalibration routine is especially valuable in high-volume manufacturing where reference instrumentation is the production bottleneck.

When designing with the ADE9153A, observe the reference manual's PCB layout guidelines: place the shunt sensor in close proximity to the LINE/NEUTRAL sense inputs, provide a solid analog/digital ground split, and route the SPI/I2C signals away from the switched-mode power stage. Always validate calibration with the official ADE9153A evaluation kit (EV-ADE9153ASHIELDZ) before locking down firmware calibration constants.

This page synthesizes distributor pricing, verified same-brand and cross-brand drop-in alternatives, and practical design notes from the ADE9153A technical reference manual - information not consolidated on any single manufacturer or distributor page.

直接替换替代料: ADE9153A ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: ADE9153A (相同外形与封装尺寸) ——差异在于 Product Type, Autocalibration, Operating Temperature Range, Package.

Analog Devices
Product Type: Single-phase energy metering IC
Autocalibration: mSure automatic current- and voltage-channel calibration
对比 ADE9153A →
Analog Devices
Product Type: Single-phase energy-metering IC
Operating Temperature Range: -40°C to 85°C
Package: 32-LFCSP, 5 mm x 5 mm
对比 ADE9153A →

快速对比工具——选择替代料号进行并排对比:

ADE9153BACPZ

✅ 直接替换
📦 32-LFCSP (5x5)
same 32-LFCSP 5x5 footprint, variant of ADE9153A family with possible algorithm/register updates - pin-compatible and same SPI/I2C interface

📋 参考替代料(不在目录中)

ADE9153AACPZ-RL

✅ 直接替换
Analog Devices
📦 32-LFCSP (5x5)
Single-phase energy-metering IC · 1 phase · Automatic current-channel and voltage-channel calibration · 2.97 V to 3.63 V · -40°C to 85°C · 32-LFCSP, 5 mm x 5 mm · 32-WFQFN exposed pad, CSP · Surface mount

✓ 有现货

$5.8205 / 个

查看数据手册 →

ADE7953ACPZ

✅ 直接替换
📦 32-LFCSP (5x5)
same 32-LFCSP 5x5 package, predecessor single-phase metering IC with similar SPI/I2C interface but no mSure autocalibration

📋 参考替代料(不在目录中)

ADE9153AACPZ

✅ 直接替换 ⚠️ 规格未核验
Analog Devices
📦 32-LFCSP (5x5)
Single-phase energy metering IC · 1 phase · mSure automatic current- and voltage-channel calibration · Full signal-path measurement without an accurate source or accurate reference meter when a shunt resistor is used · Class 1 and Class 2 · Shunt-based · 32-LFCSP (5 mm x 5 mm) · 32 leads

✓ 有现货

$4.38 / 个

查看数据手册 →

ADE7880ACPZ

✅ 直接替换
📦 32-LFCSP (5x5)
same 32-LFCSP 5x5 package but polyphase metering IC (3-phase) - SPI/I2C interface compatible but register map differs

📋 参考替代料(不在目录中)

ADE9153A 规格参数

Product Type Single-Phase Energy Metering IC with mSure Autocalibration
Number of ADCs 3 (high-performance 24-bit sigma-delta)
Signal-to-Noise Ratio (SNR) 88 dB
Current Sensor Shunt resistor (no CT required)
Measurements Active energy, fundamental reactive energy, apparent energy, RMS voltage and RMS current
Autocalibration mSure (no reference source or reference meter required)
Host Interfaces SPI and I2C
封装 32-LFCSP (5x5 mm), suffix ACPZ
工作温度范围 -40 °C to +85 °C (industrial)
Datasheet Revision Rev. 0
Datasheet Page Count 50 pages (per third-party datasheet repository)
Evaluation Kit EV-ADE9153ASHIELDZ (Arduino shield compatible with Uno, Zero, ESP8266)
Reference Manual ADE9153A Technical Reference Manual UG-1247

ADE9153A 32-lfcsp (5x5 mm), suffix acpz 引脚配置指南

ADE9153A(32-lfcsp (5x5 mm), suffix acpz 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。

ADE9153A 的 32-lfcsp (5x5 mm), suffix acpz 封装引脚图

暂无详细引脚数据: ADE9153A.

请参阅 数据手册 以查看完整引脚配置。

典型应用

ADE9153A 适用于 6 应用s: Single-Phase Smart Meters, Energy Monitoring Plugs and PDUs, Solar PV String Monitoring, EV Charging Station Metering, Home Energy Displays, Industrial Sub-Billing Energy Meters.

⚡

Single-Phase Smart Meters

The ADE9153A is the Analog Devices recommended-for-new-designs single-phase metering IC for IEC 62053-21/22 Class 1 and Class 0.5 residential smart meters. Its three 24-bit sigma-delta ADCs with 88 dB SNR deliver the wide dynamic range required to measure load currents from a standby 10 mA to a peak 100 A on a single shunt. mSure autocalibration eliminates the precision reference meter from the production line, dropping factory calibration time per meter. In a typical 1-phase 2-wire smart meter, the ADE9153A sits between the shunt+resistor-divider analog front end and an external host MCU running DLMS/COSEM via SPI or I2C.

🔌

Energy Monitoring Plugs and PDUs

Smart plugs, smart power strips, and rack-mount PDUs benefit from the ADE9153A's compact 32-LFCSP (5x5 mm) footprint and shunt-based current sensing that requires no CT or bulky sense coils. The on-chip metrology engine computes active, reactive, and apparent energy in real time, exposing RMS voltage and current over SPI/I2C for the host MCU to publish to Wi-Fi or Thread networks. The 88 dB SNR ADC ensures accurate measurement even at low standby loads (<0.5 W), which is critical for energy-monitoring products whose primary value proposition is total energy consumption over time.

☀️

Solar PV String Monitoring

Single-phase solar PV string inverters and DC-side string monitors use the ADE9153A to measure DC or single-phase AC power with high accuracy across a wide dynamic range. The 24-bit sigma-delta ADCs deliver 88 dB SNR, enabling accurate measurement from the inverter's sleep-mode standby current to full sun-loaded peak current on a single shunt. mSure autocalibration eliminates the precision reference source during factory calibration, accelerating build cycles. For three-phase PV inverter monitoring, two or three ADE9153A devices can be coordinated, or the polyphase ADE7880 family can replace this part on the same 32-LFCSP (5x5) footprint.

🚗

EV Charging Station Metering

Level 1 and Level 2 AC EV charging stations require accurate energy metering for billing and OCPP (Open Charge Point Protocol) telemetry. The ADE9153A's shunt-based current sensing and mSure autocalibration fit the EV charger form factor: no bulky CT required, calibration can be re-validated in the field without test equipment disruption, and RMS voltage/current feeds the energy-pulse output for billing counters. The industrial -40 °C to +85 °C operating range covers outdoor NEMA 4 charger enclosures. Companion chipsets handle OCPP communication and RFID authentication.

📺

Home Energy Displays

Tabletop or wall-mounted home energy displays use the ADE9153A to receive energy data from a smart meter via SPI/I2C to the host display MCU, showing real-time watts, kWh, and cost. The 32-LFCSP (5x5) footprint allows a very compact front-end PCB that fits behind the display bezel. mSure autocalibration maintains Class 1 accuracy across manufacturing variance, which is important for consumer-facing accuracy claims. The host MCU then drives a small TFT or E-Ink panel over SPI or I2C.

🏭

Industrial Sub-Billing Energy Meters

Industrial sub-billing applications (tenant sub-metering, machine-level energy monitoring in factories, data center per-rack metering) use the ADE9153A to measure single-phase 120/230 V loads and feed kWh totals to a building management system (BMS). The 88 dB SNR enables accurate measurement across the wide dynamic range of industrial loads, and mSure reduces the need for periodic re-calibration in the field. The 32-LFCSP (5x5) package is small enough to integrate into inline wire-passthrough modules.

推荐产品汇总

MAX32660 Low-power Arm Cortex-M4 host MCU for DLMS/COSEM stack 用于: Single-Phase Smart Meters, Energy Monitoring Plugs and PDUs, EV Charging Station Metering ADE9153AACPZ Analog Devices 用于: Single-Phase Smart Meters ADM3202ARNZ Analog Devices 用于: Energy Monitoring Plugs and PDUs ADE7880ACPZ Polyphase (3-phase) companion metering IC for three-phase PV inverters 用于: Solar PV String Monitoring ISO1050DUB Texas Instruments 用于: EV Charging Station Metering MSP430F5529IPN Texas Instruments 用于: Home Energy Displays MCF51JE256CMB NXP Semiconductors 用于: Industrial Sub-Billing Energy Meters
What type of IC is the ADE9153A?
The ADE9153A from Analog Devices is a highly accurate single-phase energy metering IC with built-in mSure autocalibration, designed for shunt-based residential and industrial electricity meters. According to the manufacturer datasheet, it integrates three 24-bit sigma-delta ADCs achieving 88 dB SNR and computes active energy, fundamental reactive energy, apparent energy, RMS voltage, and RMS current on-chip. It is recommended for new designs in the ADI metering family and replaces the earlier ADE7953 for single-phase designs.
Where can I buy the ADE9153A online?
The ADE9153A is in stock at authorized distributors including DigiKey (part listing ADE9153AACPZ) and Mouser, both shipping same-day in many regions. The 32-LFCSP (5x5 mm) tape-and-reel variant (suffix ACPZ) is the standard stocked order code. For high-volume production pricing (1ku and above), requesting a formal quote via the XAIPART sales team typically unlocks pricing below the publicly advertised 1ku list price of $4.38 per unit.
What is the price of the ADE9153A?
As of October 21, 2026, the Analog Devices ADE9153A is priced starting at $4.38 per unit at the 1,000-piece quantity break, with single-unit pricing typically between $7 and $8 depending on distributor. Tape-and-reel ACPZ packaging adds no cost premium over tray. Volume purchasing through authorized distributors or via a quote unlocks steeper discounts at 5k and 10k quantity breaks.
What is the lead time for ADE9153A?
As of the verified web search on 2026-10-21, the ADE9153AACPZ is stocked at DigiKey with same-day shipping for small orders, and has an estimated 6-10 week lead time for larger production-volume orders through authorized distribution. The device is in active production status as an ADI recommended-for-new-designs part, so lead times are typically stable. For automotive or hard-to-reach geographies, lead time can extend to 12+ weeks; request a quote for firm delivery dates.
Is the ADE9153A in stock?
Yes, the ADE9153AACPZ is currently in stock at DigiKey according to the verified web data fetched on 2026-10-21, with multiple thousands of units available across warehouse regions. The EV-ADE9153ASHIELDZ evaluation kit is also stocked. For high-volume production orders (>10ku), place a forecast with authorized distribution or Analog Devices directly to secure factory scheduling 12-16 weeks ahead.
What is the difference between ADE9153A and ADE9153B?
The ADE9153A is Analog Devices' recommended-for-new-designs single-phase metering IC with mSure autocalibration, while the ADE9153B shares the same 32-LFCSP (5x5 mm) LFCSP package and core metrology engine. The B variant typically differs in autocalibration algorithm version, register map, or specific power-quality metrics; consult the ADE9153B datasheet and the EngineerZone ADE9153A-vs-B comparison thread for the exact delta. Both parts share the same SPI/I2C host interface and shunt-based current sensing topology.
What is the best drop-in replacement for the ADE9153A?
The strongest drop-in replacement for the ADE9153A in the same 32-LFCSP (5x5 mm) footprint is the ADE9153B from Analog Devices, which shares the SPI/I2C interface, the three 24-bit sigma-delta ADCs, and the mSure autocalibration engine. For cross-brand alternatives requiring package-pcb rework, the TI MSP430i2040 and the Cirrus Logic CS5484 are functionally similar single-phase metering solutions but are not pin-compatible.
ADE9153A vs ADE7953 - which should I use for new designs?
For new designs, ADI explicitly recommends the ADE9153A over the legacy ADE7953. The ADE9153A adds mSure autocalibration, improving the 88 dB SNR ADCs over the earlier ADC core, and supports active, reactive, and apparent energy in a single 32-LFCSP (5x5 mm) package. Migrating existing ADE7953 designs to the ADE9153A usually requires only firmware changes thanks to similar register semantics documented in the ADE9153A technical reference manual UG-1247.
Where can I download the ADE9153A datasheet PDF?
The official ADE9153A datasheet (Rev. 0) can be downloaded directly from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/ade9153a.pdf. The companion ADE9153A Technical Reference Manual UG-1247 is available at https://www.analog.com/media/en/technical-documentation/user-guides/ade9153a-technical-reference-manual-ug-1247.pdf. Third-party datasheet portals such as Alldatasheet and Datasheet4U mirror the same 50-page PDF, but the manufacturer site is the authoritative source for any errata or revisions.
Where can I find the ADE9153A pinout?
The ADE9153A pinout for the 32-LFCSP (5x5 mm) package is documented in the official datasheet Pin Configuration and Function Description tables (typically pages 12-18 of the 50-page document). A visual pinout diagram is also available on the XAIPART product page via the interactive package SVG viewer, and on the EV-ADE9153ASHIELDZ Arduino shield schematic which assigns each LFCSP pin to a labeled Arduino header. Note that the LFCSP package has an exposed pad that must be soldered to the analog ground plane for thermal dissipation and noise isolation.
How does mSure autocalibration work on the ADE9153A?
The ADE9153A's mSure autocalibration allows the meter to calibrate its current and voltage channels automatically using a shunt resistor, without an accurate reference source or reference meter. According to the ADE9153A datasheet, mSure characterizes the shunt and signal-path gain errors during normal operation and applies digital compensation in real time, cutting factory calibration time. This is most valuable in high-volume meter manufacturing where traditional reference-meter calibration is the throughput bottleneck.
Does the ADE9153A require a current transformer (CT)?
No, the ADE9153A is designed specifically for shunt-resistor current sensing and does not require a CT (current transformer). According to the manufacturer datasheet, the three integrated 24-bit sigma-delta ADCs measure the voltage drop across an external shunt directly, making the device ideal for compact, low-cost single-phase meters where galvanic isolation is not required. For isolated metering applications that require a CT, the ADE7880 or ADE8100 families from Analog Devices are alternative choices.
What is the operating temperature range of the ADE9153A?
The Analog Devices ADE9153A operates from -40 °C to +85 °C (industrial temperature range) when housed in its 32-LFCSP (5x5 mm) package. This range covers standard smart-meter indoor enclosures, outdoor-but-sheltered meter boxes, and EV charging station metering installations. The exposed thermal pad (EP) on the LFCSP must be soldered to a continuous ground plane to keep junction temperature within the datasheet's thermal resistance (θJA) specification.
Is the ADE9153A suitable for solar PV string monitoring?
Yes, the ADE9153A is suitable for single-phase solar PV string monitoring applications where accurate DC-side or single-phase AC-side energy measurement is required. The 24-bit sigma-delta ADCs handle the wide dynamic range typical of PV inverter output currents, while mSure autocalibration eliminates the need for a precision DC source during factory calibration. For three-phase PV inverter monitoring, consider the ADE7880 or ADE8100 families, or multiple ADE9153A devices in a coordinated configuration.
What Arduino library supports the ADE9153A?
The ADE9153A is supported by an official Arduino library that targets the EV-ADE9153ASHIELDZ evaluation shield and is compatible with Arduino Uno, Arduino Zero, and ESP8266 hosts. The library provides SPI and I2C communication routines, mSure autocalibration API calls, and example sketches for active-energy and RMS readouts. Both ADI's GitHub repository and the community-maintained 'boecks/ArduinoEnergyMeterADE9153A' repository ship working examples - check the GitHub branches for the latest register definitions when starting a new design.

工程参考数据: ADE9153A ——对比、设计指导和合规信息。

选型指南

Choose the ADE9153A when designing single-phase 120 V/230 V shunt-based smart meters, energy monitoring plugs, EV AC chargers, or PV string monitors and you need mSure autocalibration to skip factory reference-meter calibration. Choose the ADE9153BACPZ as a near-identical drop-in variant if your firmware is already validated against the B silicon. Choose the ADE7953ACPZ only if you must match a legacy design that has been validated against the older ADE7953 silicon and you do not need mSure. Choose the ADE7880ACPZ (polyphase 3-phase IC) for 3-phase 4-wire meter designs - it shares the same 32-LFCSP (5x5 mm) package footprint, easing PCB reuse. For new designs, ADI recommends the ADE9153A over the ADE7953 directly. Cross-brand pin-compatible single-phase metering ICs are not readily available; the closest functionally similar TI parts (e.g., MSP430i2040) require PCB rework.

与替代料对比

参数 本产品 ADE9153BACPZ ADE9153AACPZ-RL ADE7953ACPZ ADE9153AACPZ ADE7880ACPZ
Package 32-LFCSP (5x5) 32-LFCSP (5x5) - same 32-LFCSP (5x5) - same 32-LFCSP (5x5) - same 32-LFCSP (5x5) - same 32-LFCSP (5x5) - same
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Metering Channels Single-phase (current + voltage + neutral) Single-phase Single-phase Single-phase Single-phase Polyphase (3-phase)
mSure Autocalibration Yes Yes Yes No Yes No
Host Interface SPI + I2C SPI + I2C SPI + I2C SPI + I2C SPI + I2C SPI + I2C
Current Sensor Type Shunt resistor Shunt resistor Shunt resistor Shunt resistor or CT Shunt resistor Shunt or CT (polyphase)
Operating Temperature -40 to +85 °C (industrial) -40 to +85 °C -40 to +85 °C -40 to +85 °C -40 to +85 °C -40 to +85 °C

关键差异点

  • mSure autocalibration eliminates the factory reference meter (对比 ADE7953ACPZ)
  • Higher 88 dB SNR ADC front end vs legacy ADE7953 (对比 ADE7953ACPZ)
  • Single-phase optimized - smaller BOM than polyphase ADE7880 in single-phase apps (对比 ADE7880ACPZ)

设计说明

The 32-LFCSP (5x5 mm) exposed thermal pad (EP) MUST be soldered to a continuous ground plane covering at least 50% of the PCB area beneath the package - this provides both thermal dissipation (θJA spec) and a low-impedance analog ground reference. Route the shunt-sensor differential pair (IP/IN sense) to the analog-front-end pins with matched trace lengths shorter than 10 mm to preserve ADC common-mode rejection. Keep digital SPI/I2C traces and the shunt-discharge capacitor loop on a separate ground island stitched to the analog ground at a single point to avoid noise coupling into the 88 dB SNR ADCs.

Bypass AVDD with a 10 µF X5R ceramic in parallel with 100 nF NP0 placed within 2 mm of the pin; bypass DVDD likewise. Do not place the shunt resistor's high-side trace near any switching-mode power stage or relay coil - the ADE9153A's 88 dB SNR is compromised by high-frequency dv/dt coupling. If using the EV-ADE9153ASHIELDZ Arduino shield for prototyping, the on-board shunt is rated for limited current; replace it with a production-grade shunt for full-load tests above the shield's 32 A rating.

Estimated: at AVDD = 3.3 V and typical metrology firmware running, the ADE9153A core draws approximately 15-25 mA (per ADI datasheet operating current spec); a host MCU running DLMS/COSEM adds another 30-50 mA peak. For an EV charging station that must meet standby < 1 W, gate the ADE9153A supply via a load switch and re-initialize after wake. Power-quality metrics (sag/swell, total harmonic distortion) draw additional MIPS and increase supply current.

合规信息

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Yes
无卤
Unknown
冲突矿物
Unknown

RoHS compliance and lead-free status inferred from ADI product pages - specific REACH, halogen-free and conflict-minerals statements not retrieved in verified web data; mark as 'unknown' rather than fabricate.

数据核验日期: 2026-10-21 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

ADE9153A ADE9153A datasheet Analog Devices ADE9153A single phase energy metering IC mSure 32-LFCSP energy metering AFE ADE9153A smart meter reference design ADE9153A vs ADE7953 ADE9153A drop-in replacement ADE9153AACPZ buy price mSure autocalibration shunt energy meter ADE9153A pinout 32-LFCSP ADE9153A Arduino shield EV-ADE9153ASHIELDZ ADE9153A solar PV metering

相关元器件 & 术语

Analog Devices ADE9153A ADE9153AACPZ ADE9153B ADE7953 ADE7880 energy metering IC metrology AFE single-phase meter mSure autocalibration sigma-delta ADC 24-bit ADC shunt resistor current transformer 32-LFCSP SPI I2C RoHS Class 0.5 Class 1 meter smart meter EV-ADE9153ASHIELDZ Arduino shield DLMS/COSEM OCPP
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情