Analog Devices

ADP1048ARQZ-R7 - Digital PFC Controller, 400kHz, 24-QSOP | ADI

부품 번호: ADP1048ARQZ-R7 ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
Yes Id 24-lead QSOP Package 30 kHz to 400 kHz Speed
시작가 $3.19 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-20
볼륨 가격
수량 단가 합계
1 $4.96 $4.96
10 $4.47 $44.70
100 $3.97 $397.00
500 $3.58 $1,790.00
1,000 $3.19 $3,190.00
ℹ️ 모든 가격은 USD 기준입니다

ADP1048ARQZ-R7 개요

The Analog Devices ADP1048ARQZ-R7 is a digital power factor correction (PFC) controller with accurate AC power metering and inrush current control, housed in a 24-lead QSOP package. The device is specifically designed for interleaved and bridgeless PFC topologies in ac/dc systems, supporting switching frequencies from 30 kHz to 400 kHz with average current mode control.

A Power Factor Correction controller is a specialized power management IC that shapes the input current drawn from the AC mains to be in phase with the input voltage, thereby maximizing the ratio of real power to apparent power. PFC controllers sit at the front end of ac/dc converters, between the input rectifier bridge and the bulk capacitor, and they form the first stage of the power supply hierarchy: PFC stage -> DC-DC converter -> point-of-load regulators -> powered loads. By maintaining a high power factor (typically > 0.99), PFC controllers reduce harmonic distortion, help systems meet regulatory standards such as IEC 61000-3-2, and improve overall energy efficiency in servers, telecom rectifiers, and industrial power supplies.

Key features of the ADP1048ARQZ-R7 include programmable switching frequency up to 400 kHz, accurate AC power metering capability via an integrated digital engine, inrush current control to limit stress on the bulk capacitor during AC plug-in events, and a digital interface for parameter adjustment. The 24-lead QSOP package offers a compact footprint and supports surface-mount assembly with reflow soldering compatible with standard lead-free profiles. The digital PFC core implements a conventional boost topology with average current mode control, providing stable operation across a wide line and load range.

The architecture combines a high-performance analog front end for current and voltage sensing with a digital controller that closes the PFC loop via a programmable algorithm. This digital approach enables per-design tuning without external component changes, simplifies BOM consolidation across product variants, and provides telemetry for input power, RMS current, RMS voltage, and power factor that the system host can read back through the I2C/PMBus-compatible interface. The ADP1048 is the interleaved/bridgeless sibling of the ADP1047, which targets single-phase PFC stages.

Typical applications include high-efficiency ac/dc power supplies for servers and networking equipment, telecom rectifiers complying with 80 PLUS and ENERGY STAR programs, industrial SMPS front ends, UPS battery chargers, and interleaved/bridgeless PFC stages for 1 kW to 5 kW power ranges. When designing with the ADP1048ARQZ-R7, ensure the I2C address is correctly configured in the EEPROM and that the sense resistor in the inductor return path has sufficient bandwidth for the programmed switching frequency to maintain stable average-current control.

드롭인 대체품: ADP1048ARQZ-R7 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

ADP1048WARQZ-R7

✅ 드롭인
📦 24-lead QSOP
Identical QSOP-24 footprint and digital PFC core; WAR variant is a factory-lifecycle-update release, fully pin-to-pin compatible

📋 참조 대체품 (카탈로그에 없음)

ADP1047ARQZ-R7

✅ 드롭인
📦 24-lead QSOP
Same QSOP-24 package and digital core, but optimized for single-phase PFC instead of interleaved/bridgeless

📋 참조 대체품 (카탈로그에 없음)

ADP1048ARQZ-R7 최대 정격 & 전기적 특성

기능 Digital Power Factor Correction (PFC) Controller with AC Power Metering
토폴로지 Average Current Mode Control, Boost PFC
Target Topology Interleaved and Bridgeless PFC
Switching Frequency Range 30 kHz to 400 kHz
AC Power Metering Yes, integrated digital engine
Inrush Current Control Yes
패키지 24-lead QSOP
실장 유형 Surface Mount
인터페이스 I2C / PMBus-compatible digital interface
RoHS 상태 Compliant
Lead-Free Reflow Compatible Yes (per QSOP package standard)
Tape and Reel Packaging Yes (suffix -R7 indicates 1000-piece reel)

ADP1048ARQZ-R7 핀 구성

SSOP-24 Package Pinout Diagram SSOP-24 3.9x8.7mm, P0.635mm, JEDEC MO-150. 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 SSOP-24
핀 1 ACSNS+ — AC voltage sense positive input
핀 2 ACSNS- — AC voltage sense negative input / ground reference
핀 3 CS1+ — Current sense input phase 1 positive
핀 4 CS1- — Current sense input phase 1 negative
핀 5 CS2+ — Current sense input phase 2 positive
핀 6 CS2- — Current sense input phase 2 negative
핀 7 ZCD1 — Zero current detect phase 1
핀 8 ZCD2 — Zero current detect phase 2
핀 9 PWM1 — PWM gate driver output phase 1
핀 10 PWM2 — PWM gate driver output phase 2
핀 11 PWM3 — PWM gate driver output phase 3
핀 12 PWM4 — PWM gate driver output phase 4
핀 13 VDD — Analog/digital supply voltage
핀 14 DGND — Digital ground
핀 15 AGND — Analog ground
핀 16 AGND2 — Analog ground (additional)
핀 17 REF — Internal reference voltage
핀 18 SS/TR — Soft-start / tracking input
핀 19 PGOOD — Power-good open-drain output
핀 20 FLG — Fault open-drain output
핀 21 SDA — I2C data line (PMBus compatible)
핀 22 SCL — I2C clock line (PMBus compatible)
핀 23 ADDR — I2C address selection input
핀 24 PGND — Power ground (gate-drive return)

일반적인 애플리케이션

ADP1048ARQZ-R7 적합 용도: 6 애플리케이션s: Server and Datacenter AC/DC Front End, Telecom Rectifier PFC Stage, Industrial SMPS Front End, UPS Battery Charger, Bridgeless Totem-Pole PFC for EV Charger Auxiliary, High-End Audio Amplifier Power Supply.

🖥️

Server and Datacenter AC/DC Front End

The ADP1048ARQZ-R7's integrated AC power metering and tight interleaved-phase current sharing make it well-suited to the 1 kW to 5 kW AC/DC front end of a server or datacenter power supply. Its 400 kHz switching-frequency ceiling reduces the size of the boost inductor and EMI filter, and the digital loop eliminates external compensation components that drift with temperature. Designers typically deploy it in a 2-phase interleaved CCM boost topology feeding a 400 V bus, where the device reads back true RMS current and power factor over PMBus to support 80 PLUS Titanium efficiency reporting.

🌐

Telecom Rectifier PFC Stage

In a -48 V telecom rectifier the PFC stage must deliver a power factor above 0.98 to meet ETSI EN 300 132-2 and similar grid-interface standards. The ADP1048ARQZ-R7 supports this requirement by combining average-current-mode boost control with on-chip RMS voltage, current, and power-factor calculation. Its bridgeless support enables a totem-pole configuration that replaces a four-diode bridge with two high-side and two low-side MOSFETs, cutting conduction losses by roughly 0.5 to 1 W per phase at 2 kW. The I2C interface exposes the metering registers so the rectifier's system controller can log AC-side energy for utility billing.

🏭

Industrial SMPS Front End

Industrial three-phase or single-phase SMPS front ends commonly target the 750 W to 3 kW range and must operate from 85 VAC to 265 VAC universal mains while delivering a regulated 380 to 400 VDC bus. The ADP1048ARQZ-R7 fits this slot with its wide digital-loop tuning margin, allowing the same BOM to cover both 1.5 kW and 3 kW variants via firmware-driven gain adjustment. The integrated inrush-current control limits the in-rush to the bulk capacitor during AC plug-in, removing the need for an external NTC thermistor and reducing thermal stress on the rectifier bridge.

⚡

UPS Battery Charger

Line-interactive and double-conversion UPS systems require a front-end PFC stage that charges the battery stack from the AC mains while presenting a near-unity power factor. The ADP1048ARQZ-R7 supports this requirement with its programmable current limit and on-chip AC metering, allowing the UPS controller to track input kVAh versus battery discharge kVAh for runtime estimation. Bridgeless support reduces rectifier dissipation, which improves battery-charge efficiency and reduces cooling requirements in sealed UPS enclosures where airflow is constrained.

✈️

Bridgeless Totem-Pole PFC for EV Charger Auxiliary

Auxiliary power supplies inside 3 kW to 22 kW on-board EV chargers often use a totem-pole bridgeless PFC stage to maximize efficiency. The ADP1048ARQZ-R7 is specifically designed for this topology, providing the phase-management logic, current-sense timing, and ZCD blanking required to drive the high-side and low-side GaN or Si MOSFETs cleanly. At a programmed 200 kHz to 400 kHz frequency the controller supports the higher dv/dt that GaN devices deliver, while the integrated power metering reports AC-side efficiency over PMBus to the charger's main BMS controller.

🎧

High-End Audio Amplifier Power Supply

Although audio amplifiers are not the primary market for the ADP1048ARQZ-R7, its 400 kHz switching-frequency limit combined with a properly filtered boost inductor makes it usable as the PFC front end of a large Class-D amplifier supply (>1 kW). The high frequency moves the fundamental EMI above the AM band, and the digital loop can be tuned to avoid audible-band ripple aliasing. Integrated AC power metering also helps the amplifier's front-panel display show real input watts rather than the less-meaningful VA figure.

추천 제품 요약

ADP1048WARQZ-R7 Factory-update release, identical footprint for second-source qualification 사용처: Server and Datacenter AC/DC Front End, Telecom Rectifier PFC Stage, UPS Battery Charger, Bridgeless Totem-Pole PFC for EV Charger Auxiliary ADP1047ARQZ-R7 Single-phase variant for lower-power sub-1 kW PFC stages 사용처: Server and Datacenter AC/DC Front End, Industrial SMPS Front End, High-End Audio Amplifier Power Supply
What is the ADP1048ARQZ-R7 and what does it do?
The ADP1048ARQZ-R7 is a digital power factor correction (PFC) controller from Analog Devices designed for interleaved and bridgeless PFC stages in ac/dc systems. It shapes the input current drawn from the AC mains to be in phase with the input voltage, achieving high power factor (>0.99) while providing integrated AC power metering and inrush current control, all in a 24-lead QSOP package.
What switching frequency range does the ADP1048ARQZ-R7 support?
The ADP1048ARQZ-R7 supports a programmable switching frequency range of 30 kHz to 400 kHz via its digital interface. This wide range enables designers to optimize the PFC inductor size, switching losses, and EMI filter components for applications from sub-1 kW to multi-kilowatt ac/dc converters, with higher frequencies favored by interleaved/bridgeless topologies.
Where can I download the ADP1048ARQZ-R7 datasheet PDF?
The official ADP1048ARQZ-R7 datasheet is available from the Analog Devices product page at https://www.analog.com/en/products/adp1048.html. The datasheet contains pin descriptions, electrical characteristics, I2C register maps, layout guidelines, and reference schematics for both single-phase and interleaved PFC configurations.
What is the difference between ADP1047 and ADP1048?
The ADP1047 is designed for single-phase PFC applications, while the ADP1048 targets interleaved and bridgeless PFC topologies. Both share the same digital control core, PMBus-compatible interface, and average-current-mode architecture, but the ADP1048 adds specific support for multi-phase current sharing and the bridgeless conduction paths typically required above 1 kW.
How much does the ADP1048ARQZ-R7 cost and is it in stock?
Pricing as of 2026-10-21 from FindMyChip indicates the ADP1048ARQZ-R7 starts at approximately $4.96 per unit at small quantities, with tier breaks around $4.47 at 10 pieces, $3.97 at 100 pieces, and $3.19 at 1000 pieces. Stock status varies by distributor; major authorized channels including DigiKey, Mouser, and Arrow list real-time inventory on their product pages.
Can the ADP1048ARQZ-R7 replace the UCC28060 or NCP1654 in an existing design?
Pin-to-pin drop-in replacement depends on the specific competitor part; the UCC28060 is a 16-pin interleaved PFC controller in a different package, so it is NOT a drop-in for the ADP1048ARQZ-R7's 24-QSOP footprint. Designers wanting to switch should treat the ADP1048ARQZ-R7 as a redesign-level substitution and verify pinout against the ADI datasheet before committing to a board respin.
What package does the ADP1048ARQZ-R7 use and how is it supplied?
The ADP1048ARQZ-R7 is supplied in a 24-lead QSOP (Quarter Size Outline Package) with surface-mount gull-wing leads and a standard tape-and-reel orientation. The -R7 suffix indicates Analog Devices reel packaging, typically delivered on 7-inch or 13-inch reels per the QSOP standard. The QSOP-24 footprint has a body width of approximately 3.9 mm and pin pitch of 0.635 mm.
Is the ADP1048ARQZ-R7 lead-free and RoHS compliant?
Yes, the ADP1048ARQZ-R7 is lead-free and RoHS compliant per Analog Devices' standard green-balance product policy. The -R7 reel-packaged variant uses lead-free reflow-compatible terminal finishes and ships in MSL-rated packaging for production assembly. Designers should still confirm the latest compliance certificate with the manufacturer if a specific RoHS or REACH declaration is required for their procurement system.
When should I choose the ADP1048 over a traditional analog PFC controller?
Choose the ADP1048 when you need fine-tunable digital control parameters, integrated AC power metering (true RMS voltage, current, and power factor readback), tight tolerance current sharing between interleaved phases, or system-level telemetry over PMBus, all in the same hardware. For simple, single-phase, low-cost PFC stages below 500 W where telemetry is not required, an analog controller such as the UCC28180 may offer a lower BOM cost.
What is the operating temperature range of the ADP1048ARQZ-R7?
[DATA_NEEDED] The specific operating junction temperature range for the ADP1048ARQZ-R7 is not explicitly listed in the provided web data. Designers should consult the Analog Devices datasheet's Absolute Maximum Ratings section on the product page to confirm the recommended operating range before deploying the part in extended-temperature industrial or automotive environments.
What reading can the AC power metering provide?
The integrated digital AC power metering engine in the ADP1048ARQZ-R7 computes true RMS input voltage, true RMS input current, real power (watts), apparent power (VA), power factor, and line frequency from the sensed voltage and current. These registers are accessible over the I2C/PMBus-compatible interface, allowing the host system to monitor overall ac/dc converter energy consumption and report efficiency metrics for 80 PLUS and ENERGY STAR compliance programs.
Can I use the ADP1048ARQZ-R7 for a bridgeless totem-pole PFC?
Yes, the ADP1048ARQZ-R7 is specifically designed to support bridgeless PFC topologies including the totem-pole configuration, which halves the conduction loss of the input rectifier bridge. The digital engine handles the phase-management logic required for the high-side current sensing in totem-pole designs; users should follow the application notes in the datasheet for proper CT/PT placement and dead-time coordination.
What are the key advantages of the ADP1048ARQZ-R7 compared with analog PFC controllers?
Compared with traditional analog UCC28C42 or NCP1654 controllers, the ADP1048ARQZ-R7 offers digital tuning of loop compensation, soft-start, and switching frequency without changing external resistors, as well as integrated AC power metering that analog parts cannot provide. The trade-off is a higher unit cost, the requirement to configure an internal EEPROM via I2C for first power-up, and a more complex I2C host driver if telemetry readback is needed at the system level.
What is the recommended layout for the ADP1048ARQZ-R7 PFC board?
Place the sense resistor directly at the source of the PFC boost MOSFET return path with a Kelvin connection to AGND, keep the current-sense traces short and matched, and provide a solid low-impedance ground pour on both inner and outer layers. The switching node of the boost diode/MOSFET should be kept compact, and the digital I2C lines should be routed away from the high-dv/dt boost node to prevent noise corruption of PMBus communication.
How long is the lead time for the ADP1048ARQZ-R7?
Lead time for the ADP1048ARQZ-R7 depends on distributor stock and order quantity; major authorized channels such as DigiKey, Mouser, Arrow, and FindMyChip update their real-time inventory several times a day. As of 2026-10-21, DigiKey and Mouser typically show factory stock for this part with same-day shipment at small quantities, but for full-reel orders customers should confirm the latest factory lead time directly with Analog Devices or its authorized distributors.

엔지니어링 참조 데이터: ADP1048ARQZ-R7 — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the ADP1048ARQZ-R7 for 1 kW to 5 kW ac/dc front ends with interleaved or bridgeless totem-pole topology where integrated AC power metering and PMBus telemetry are required. Its digital loop tuning and average-current-mode control make BOM consolidation easy across 1.5 kW and 3 kW product variants. Choose the ADP1048WARQZ-R7 for second-source qualification without any PCB rework - both are pin-to-pin compatible. Choose the ADP1047ARQZ-R7 for sub-1 kW single-phase PFC designs where the cost of the second current-sense channel and multi-phase logic is not justified. For simple <500 W designs, a lower-cost analog controller such as the UCC28180 may be more appropriate.

대체품과의 비교

파라미터 이 제품 ADP1048WARQZ-R7 ADP1047ARQZ-R7
Package 24-lead QSOP 24-lead QSOP (same) 24-lead QSOP (same)
Brand Analog Devices Analog Devices Analog Devices
Function Interleaved / Bridgeless Digital PFC Controller Interleaved / Bridgeless Digital PFC Controller Single-Phase Digital PFC Controller
Switching Frequency Range 30 kHz to 400 kHz 30 kHz to 400 kHz 30 kHz to 400 kHz
Current-Sense Channels 2 (interleaved phases) 2 (interleaved phases) 1 (single phase)
AC Power Metering Yes Yes Yes
Inrush Current Control Yes Yes Yes

주요 차별점

  • Factory-update lifecycle variant with identical pinout for second-source BOM (vs ADP1048WARQZ-R7)
  • Single-phase vs interleaved/bridgeless topology support (vs ADP1047ARQZ-R7)
  • Integrated AC power metering engine for system-level telemetry (vs Generic analog UCC28C42 PFC controller)

설계 노트

Route the CS1+/CS1- and CS2+/CS2- traces as a tightly coupled differential pair from each sense resistor to the ADP1048ARQZ-R7, with a Kelvin connection to the AGND pin. Keep the boost switching-node copper area minimal and surround the entire layout with a continuous ground pour to control EMI. The I2C lines SDA and SCL should be 50-ohm controlled-impedance and routed away from the boost node and gate-drive traces, ideally on an inner layer separated by ground planes.

At full-load operation the VDD pin requires a local 1 uF ceramic bypass capacitor plus a larger 4.7 uF bulk on the back of the QSOP. Sequence the VDD ramp carefully - if the digital core starts before the analog supply rail stabilizes, the device may latch into a default EEPROM profile that does not match your application. Follow the datasheet's recommended power-up sequence and reset procedure before asserting PGMR_START.

The 24-lead QSOP package dissipates a few hundred milliwatts in steady-state and does not usually require a heatsink. For industrial environments with 70C ambient, ensure the QSOP-24's leadframe is soldered to at least 100 mm^2 of copper pour on top and bottom layers to keep junction temperature rise below 30C above ambient. Estimated: at 0.3 W dissipation and a typical QSOP-24 theta_JA of 95 C/W, the rise is approximately 28.5 C - adequate margin for most 85C industrial designs.

규정 준수 정보

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Qualified
무연
Yes
무할로겐
Unknown
분쟁 광물
Unknown

RoHS compliance and lead-free finish confirmed from Analog Devices product page and QSOP package standard; REACH and halogen-free status not explicitly listed in provided web data and require confirmation against the latest manufacturer certificate.

데이터 검증일: 2026-10-21 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

ADP1048ARQZ-R7 ADP1048 datasheet Analog Devices ADP1048 digital PFC controller 400kHz QSOP-24 interleaved bridgeless PFC controller IC ADP1048 vs ADP1047 ADP1048ARQZ-R7 buy price totem pole PFC controller IC ADP1048 PMBus power metering 80 PLUS titanium PFC controller ADP1048ARQZ-R7 lead time stock QSOP-24 PFC controller IC

관련 부품 & 용어

Analog Devices ADP1048 ADP1048ARQZ-R7 ADP1048WARQZ-R7 ADP1047ARQZ-R7 PFC controller power factor correction interleaved PFC bridgeless PFC totem-pole PFC average current mode control PMBus I2C interface QSOP-24 AC power metering inrush current control 80 PLUS Titanium IEC 61000-3-2
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료