ADS1213U/1K - 22-Bit 4-Channel Delta-Sigma ADC | Texas Instruments
부품 번호: ADS1213U/1K ✓ 활성ADS1213U/1K 개요
A delta-sigma ADC is a type of analog-to-digital converter that uses oversampling, digital filtering, and noise shaping to convert analog voltages into high-resolution digital data. The ADS1213 belongs to the ADC hierarchy that includes precision converters, serial-interface ADCs, and data-converter integrated circuits. Its four-input multiplexer allows one conversion system to monitor multiple analog nodes while retaining the resolution and low-speed measurement focus associated with high-performance delta-sigma conversion.
Key features include 22-bit resolution, four single-ended analog inputs, a 6.25-kSPS conversion rate, an internal reference, and a programmable gain amplifier. The flexible synchronous serial interface is SPI compatible and also supports a two-wire control mode for lower-cost isolation. The industrial-grade -40 °C to +85 °C range supports factory automation, process control, instrumentation, and embedded measurement systems where a small number of slowly changing analog signals must be digitized accurately.
The converter architecture emphasizes resolution rather than high-throughput sampling. Its 4-channel input structure reduces the number of separate converters needed when several sensors share a measurement system. An internal reference and PGA simplify analog front-end design by reducing external reference and gain-control requirements, although the final input range still depends on the selected gain and reference configuration. The serial interface permits compact PCB routing and straightforward connection to microcontrollers, DSPs, and industrial controllers.
Typical uses include pressure and temperature sensor acquisition, process-line monitoring, laboratory measurement equipment, factory automation, low-speed energy metering, and industrial data loggers. The ADS1213U/1K is especially appropriate when high resolution, multiple analog channels, and a compact 24-SOIC footprint matter more than thousands of conversions per second. It is less suitable for waveform capture, communications receivers, or other applications requiring wide bandwidth and very high sample rates.
Designers should determine the actual input range, digital filter behavior, data rate, and reference accuracy from the manufacturer datasheet before setting the analog front end. Input protection, source impedance, grounding, and serial-interface timing also need validation. Keep analog and digital return paths controlled, provide local supply bypassing, and account for the acquisition settling time of the delta-sigma conversion stage.
This page organizes the ADS1213U/1K specifications, verified source links, ordering information, drop-in substitution limits, comparison parameters, and application-focused design guidance. It highlights where the 22-bit resolution and four-channel multiplexing add value while preserving an explicit distinction between confirmed ordering variants and functionally similar devices that require redesign.
드롭인 대체품: ADS1213U/1K — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: ADS1213U/1K (동일 폼 팩터 및 풋프린트) — 차이점: Input Multiplexer, Programmable Gain Amplifier, Resolution, Analog Input Channels, Architecture.
ADS1213U/1KG4
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ADS1213U/1K 최대 정격 & 전기적 특성
| 분해능 | 22 bit |
| Maximum Conversion Rate | 6.25 kSPS |
| Analog Input Channels | 4 channels |
| Architecture | Delta-sigma ADC |
| Analog Supply Voltage | 5 V nominal |
| Digital Supply Voltage | 5 V nominal |
| 동작 온도 범위 | -40 °C to +85 °C |
| 패키지 | 24-pin SOIC |
| Terminal Count | 24 terminals |
| 실장 유형 | Surface mount |
| Internal Voltage Reference | Yes |
| Programmable Gain Amplifier | Yes |
| Synchronous Serial Interface | SPI compatible |
| Two-Wire Control Mode | Supported |
| Input Multiplexer | 4-channel analog input multiplexer |
ADS1213U/1K 24-pin soic 핀 구성 가이드
ADS1213U/1K(24-pin soic 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: ADS1213U/1K.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
ADS1213U/1K 적합 용도: 6 애플리케이션s: Industrial Pressure and Temperature Sensing, Process Line Monitoring, Laboratory Instrument Data Acquisition, Data Logging and Environmental Monitoring, Low-Speed Energy Measurement, Precision Test and Measurement.
Industrial Pressure and Temperature Sensing
The ADS1213U/1K fits industrial sensor acquisition when several slow-changing inputs must be digitized with better resolution than a conventional low-cost ADC. Its four-channel analog multiplexer reduces the number of converter packages needed for pressure, temperature, and level signals, while 22-bit resolution preserves fine measurement detail across a scaled input range. The 6.25-kSPS maximum conversion rate is more than adequate for continuously updated process values. A nominal 5 V supply and the -40 °C to +85 °C operating range suit factory equipment. Use the PGA and internal reference to establish the analog scaling, while checking the datasheet for channel selection, input limits, settling behavior, and recommended sensor excitation circuitry.
추천
Process Line Monitoring
The ADS1213U/1K is suitable for process-line monitoring where analog pressure, flow, or chemical-sensor signals change over seconds or minutes rather than at audio or communications bandwidths. Its four analog inputs allow a controller to monitor several related measurement points, while the 22-bit delta-sigma conversion provides a high-resolution digital representation for calibration and alarming logic. The 6.25-kSPS ceiling provides useful response for slow process variables without imposing the power and complexity associated with a fast waveform ADC. Its 24-pin SOIC package supports compact surface-mount assembly, and the SPI-compatible synchronous interface simplifies connection to a plant controller.
추천
Laboratory Instrument Data Acquisition
The ADS1213U/1K can serve as the measurement ADC in laboratory instruments that digitize low-frequency analog inputs with high resolution. Four multiplexed inputs let the instrument share one converter across sensor, reference, or status channels, while the internal reference and programmable gain amplifier help organize the measurement chain. A 22-bit converter and 6.25-kSPS maximum rate are well matched to temperature, strain, potentiometric, and other slowly varying laboratory signals. The serial interface reduces signal-routing complexity in a multi-board instrument. For bench and laboratory use, define the intended input bandwidth, digital-filter setting, settling time, and calibration procedure in the firmware before finalizing analog scaling and sampling timing.
추천
Data Logging and Environmental Monitoring
The ADS1213U/1K is appropriate for environmental and industrial data loggers that combine multiple slow sensor channels with a compact controller. Four analog inputs can capture temperature, humidity, light, or analog gas-sensor outputs, and the 22-bit resolution supports fine-grained readings after front-end scaling. The 6.25-kSPS maximum rate is suitable for periodic logging rather than real-time waveform analysis, helping the system focus on resolution and measurement repeatability. Its 24-SOIC package and SPI-compatible synchronous interface suit dense instrument boards. Designers should establish channel-switching order, per-channel settling delays, digital averaging, and power-cycling strategy so that the logged values reflect the actual sensor bandwidth rather than the converter’s maximum advertised rate.
추천
Low-Speed Energy Measurement
The ADS1213U/1K can support low-speed energy and power monitoring when the target signal changes over a measurement interval and high-resolution ADC data improves the quality of the calculated result. Its four-channel multiplexer can monitor current, voltage, or auxiliary sensing channels sequentially, while 22-bit resolution provides ample numerical headroom for carefully scaled inputs. The 6.25-kSPS maximum rate is appropriate for metering rather than capturing individual high-frequency switching waveforms. The internal reference and programmable gain amplifier assist with signal conditioning, and the compact 24-SOIC footprint simplifies board integration. Confirm whether the intended meter requires simultaneous sampling, antialias filtering, or a separate high-speed front end before assigning the converter to the final measurement path.
추천
Precision Test and Measurement
The ADS1213U/1K fits precision test equipment that evaluates slow, high-impedance analog sources and requires more resolution than a basic instrumentation ADC. Four inputs can support sequential measurement of a device under test, a reference node, and auxiliary monitor channels, while 22-bit resolution improves visibility into small deviations around a calibrated value. The 6.25-kSPS rate is suitable for settled measurements rather than continuous high-speed sampling. Its SPI-compatible synchronous interface allows straightforward connection to a test controller, and the internal reference and PGA help create a repeatable measurement front end. The final design should account for source settling, leakage, input protection, digital filtering, and calibration error to ensure that measured resolution translates into useful system accuracy.
추천
추천 제품 요약
엔지니어링 참조 데이터: ADS1213U/1K — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | ADS1213U/1KG4 |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 24-pin SOIC | 24-pin SOIC |
| Resolution | 22 bit | 22 bit |
| Maximum Conversion Rate | 6.25 kSPS | 6.25 kSPS |
| Analog Input Channels | 4 channels | 4 channels |
| Architecture | Delta-sigma ADC | Delta-sigma ADC |
| Nominal Supply Voltage | 5 V | 5 V |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C |
| Internal Reference | Yes | Yes |
| Programmable Gain Amplifier | Yes | Yes |
주요 차별점
- Closest ordering alternative retains identical core conversion specifications (vs ADS1213U/1KG4)
- Four-channel integration reduces separate converter demand (vs ADS1213U/1KG4)
- Precision conversion speed is tailored to slow industrial signals (vs ADS1213U/1KG4)
설계 노트
Route analog inputs away from the SPI clock, serial data, and digital supply return paths. Keep the analog front end close to the converter and use a continuous ground plane beneath the device and its input network. Because the four-channel multiplexer shares one conversion core, maintain symmetric input routing and controlled source impedances to reduce channel-dependent errors. Review the manufacturer recommended-layout diagram before finalizing trace spacing and component placement.
Place the analog and digital bypass capacitors at their associated supply pins and follow the capacitance and placement guidance in the manufacturer datasheet. The nominal supply is 5 V, but the permitted operating range must be checked before applying that nominal value to the final rail. Keep switching-regulator and digital logic away from sensitive analog nodes, and verify supply-noise behavior with the configured PGA gain and digital filter because gain can amplify input-referred disturbance.
Do not treat the 6.25-kSPS maximum rate as the instantaneous conversion time for every multiplexer selection. Account for analog settling, digital-filter latency, and any required averaging before calculating the usable output rate. Likewise, 22-bit converter resolution does not guarantee 22-bit system accuracy; sensor nonlinearity, reference error, resistor tolerance, noise, grounding, and input filtering determine the final measurement precision.
규정 준수 정보
The manufacturer identifies an industrial -40 °C to +85 °C temperature range, but the available product information does not explicitly confirm RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. These fields should be checked against the current manufacturer product documentation and production qualification records.