ADS1292RIPBS 개요

The Texas Instruments ADS1292RIPBS is a 2-channel, 24-bit, simultaneous-sampling analog front-end (AFE) for biopotential measurements, integrating a low-noise programmable gain amplifier (PGA), a delta-sigma analog-to-digital converter (ADC), an internal reference, and an onboard oscillator in a 32-pin TQFP (PBS) 5x5 mm package. The 'R' suffix indicates the integrated respiration impedance measurement function alongside the two ECG/EMG channels, and the part is rated for 740 uW typical power consumption at 1 kSPS.

An analog front-end (AFE) is a mixed-signal subsystem that conditions low-amplitude physiological signals (typically 1 uV to 5 mV) and digitizes them so a host processor can run diagnostic algorithms. In the hierarchy of medical electronics, AFEs sit between the electrode/sensor interface and the digital signal controller (DSC) or microcontroller, replacing the discrete instrumentation amplifier plus separate 16-/24-bit ADC approach with a single qualified, low-power IC. The ADS1292 family is optimized for electrocardiogram (ECG), electromyography (EMG), and electroencephalography (EEG) front-end designs where low input-referred noise and high common-mode rejection are mandatory for diagnostic accuracy.

Key features include 2 high-resolution 24-bit delta-sigma ADCs with simultaneous sampling up to 8 kSPS per channel, integrated PGA gains from 1 to 12, an integrated respiration modulation/demodulation circuit, a 2.7 V to 5.25 V analog supply range, a 1.8 V to 3.6 V digital I/O supply, and a flexible SPI-compatible serial interface. The device provides right-leg drive (RLD) signal generation hardware, lead-off detection comparators, and an internal oscillator that eliminates the external crystal requirement in cost-sensitive wearable designs.

Architecturally, the ADS1292 uses a chopper-stabilized input front-end combined with a 4th-order delta-sigma modulator and a multi-bit digital decimation filter to achieve input-referred noise in the microvolt range while drawing sub-milliwatt quiescent current. The integrated respiration channel uses a high-frequency AC excitation source and synchronous demodulator to extract breathing impedance without an external analog multiplier IC.

Typical applications include wearable fitness and heart-rate monitors, single-lead and multi-lead ECG patches, patient-side telemetry modules, sports and EMG rehabilitation devices, and bioimpedance-based sleep monitors. The wide supply range supports both single-cell Li-ion battery designs (3.7 V nominal) and USB-powered diagnostic instruments (5 V bus).

When designing with this device, ensure the analog and digital ground planes are joined at a single point under the IC exposed pad, place the 1 uF, 0.1 uF, and 10 uF decoupling capacitors as close as possible to AVDD and DVDD pins, and route the right-leg drive (RLD) amplifier output through a feedback network sized for the patient-electrode return path to maximize common-mode rejection at 50/60 Hz mains frequencies.

드롭인 대체품: ADS1292RIPBS — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

ADS1292IPBS

✅ 드롭인
📦 TQFP-32 (PBS) 5x5 mm
no respiration channel (no R-suffix); otherwise identical 24-bit dual-ADC AFE, same 32-pin TQFP footprint, same register map minus RESP_MOD enable bits

📋 참조 대체품 (카탈로그에 없음)

ADS1292RIPBSR

✅ 드롭인
📦 TQFP-32 (PBS) 5x5 mm
same die, tape-and-reel packaging variant (R-suffix = tape and reel, not respiration); identical silicon to ADS1292RIPBS

📋 참조 대체품 (카탈로그에 없음)

ADS1192IPBS

✅ 드롭인
📦 TQFP-32 (PBS) 5x5 mm
16-bit ADC resolution vs 24-bit (downgrade), no respiration channel; pin-compatible 32-pin TQFP per TI E2E forum confirmation

📋 참조 대체품 (카탈로그에 없음)

ADS1292RIPBS 최대 정격 & 전기적 특성

Manufacturer Texas Instruments
Product Type Analog Front End (AFE)
Number of Channels 2
ADC Resolution 24-bit
Sample Rate (max) 8 kSPS per channel
Architecture Delta-Sigma
Analog Supply Voltage 2.7 V to 5.25 V
Digital I/O Supply 1.8 V to 3.6 V
Typical Power Consumption 740 uW at 1 kSPS
PGA Gain Range 1 to 12
Integrated Respiration Channel Yes (R-suffix)
Right-Leg Drive (RLD) Amplifier Integrated
Lead-Off Detection Integrated comparators
Internal Reference Yes
Internal Oscillator Yes (external crystal not required)
Serial Interface SPI-compatible
패키지 TQFP-32 5x5 mm (PBS)
동작 온도 -40 C to 85 C
MSL 레벨 2
RoHS 상태 Compliant

ADS1292RIPBS 핀 구성

TQFP-32 (7x7mm) Package Pinout Diagram TQFP-32 7x7mm, P0.8mm, JEDEC MS-026. Pin 1 by dot. TQFP-32 (7x7mm) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
핀 1 AVDD — Analog supply
핀 2 AVSS — Analog ground
핀 3 IN1P — Channel 1 positive input
핀 4 IN1N — Channel 1 negative input
핀 5 IN2P — Channel 2 positive input
핀 6 IN2N — Channel 2 negative input
핀 7 RLDIN — Right-leg drive input
핀 8 RLDREF — Right-leg drive reference
핀 9 RLDOUT — Right-leg drive output to patient
핀 10 RESP_MODP — Respiration modulation positive output
핀 11 RESP_MODN — Respiration modulation negative output
핀 12 GPIO1 — General-purpose I/O 1
핀 13 GPIO2 — General-purpose I/O 2
핀 14 GPIO3 — General-purpose I/O 3
핀 15 GPIO4 — General-purpose I/O 4
핀 16 CS — SPI chip select (active low)
핀 17 SCLK — SPI serial clock
핀 18 DIN — SPI data input
핀 19 DOUT — SPI data output
핀 20 DRDY — Data ready (active low)
핀 21 CLK — External clock input (optional)
핀 22 START — Conversion start
핀 23 PWDN — Power-down (active high)
핀 24 RESET — Reset (active low)
핀 25 TEST1 — Test pin 1 (factory use)
핀 26 TEST2 — Test pin 2 (factory use)
핀 27 VCAP1 — Decoupling capacitor pin
핀 28 VCAP2 — Decoupling capacitor pin
핀 29 VREF — Voltage reference
핀 30 DVDD — Digital supply
핀 31 DGND — Digital ground
핀 32 AVSS — Analog ground (alternate bond)

일반적인 애플리케이션

ADS1292RIPBS 적합 용도: 7 애플리케이션s: Wearable ECG Heart-Rate Monitor, Single-Lead ECG Patch, Patient Monitoring Telemetry, EMG Rehabilitation Device, Bioimpedance / Respiration Monitor, Sports and Fitness Wearable, EEG Headband Front-End.

📱

Wearable ECG Heart-Rate Monitor

The ADS1292RIPBS fits wearable ECG heart-rate monitors because its 740 uW typical power at 1 kSPS supports multi-day operation from a small Li-ion cell, while the 24-bit delta-sigma ADC delivers input-referred noise low enough to resolve the mV-level QRS complex from dry-contact chest electrodes. The integrated PGA (gains 1-12) eliminates a discrete instrumentation amp, and the SPI interface streams samples directly to a low-power MCU. Designers should drive the right-leg drive (RLD) amplifier output through a feedback network tuned for the electrode-skin interface to maximize 50/60 Hz common-mode rejection.

💊

Single-Lead ECG Patch

The ADS1292RIPBS fits single-lead ECG patches because its 32-pin TQFP 5x5 mm footprint and 740 uW dissipation allow a thin, flexible wearable form factor. The integrated lead-off comparators detect electrode lift in real time, and the internal oscillator eliminates the external crystal often needed in patch designs. Using the R-suffix respiration channel, the same patch also captures breathing rate, doubling the clinical value without additional sensor hardware.

🏥

Patient Monitoring Telemetry

The ADS1292RIPBS fits patient monitoring telemetry because its 24-bit resolution preserves diagnostic-grade ECG morphology for arrhythmia detection, while its 5 V analog supply tolerance supports USB-powered bedside monitors. Two simultaneous-sampling channels enable either dual-lead ECG or ECG-plus-impedance respiration from a single IC, reducing BOM cost. SPI throughput up to 8 kSPS per channel accommodates higher-bandwidth signals such as pacemaker pulse detection and external pacing artifacts.

🏭

EMG Rehabilitation Device

The ADS1292RIPBS fits EMG rehabilitation devices because its wide PGA gain range (1-12) and 24-bit dynamic range capture both low-level resting muscle tone and high-level contraction bursts. The 8 kSPS per channel maximum sample rate comfortably exceeds the 4 kHz bandwidth of surface EMG signals. Battery operation from 2.7 V to 5.25 V is compatible with single-cell Li-ion chemistries common in handheld rehab stimulator/recorder products.

🌬️

Bioimpedance / Respiration Monitor

The ADS1292RIPBS R-suffix fits bioimpedance and respiration monitors because the integrated high-frequency AC excitation source and synchronous demodulator extract breathing impedance without an external analog multiplier IC. This single-chip approach reduces BOM and PCB area for wearable respiration patches and sleep-monitoring bands. Both 50 kHz and 64 kHz excitation frequencies are supported internally for impedance spectroscopy applications.

🧩

Sports and Fitness Wearable

The ADS1292RIPBS fits sports and fitness wearables because its sub-milliwatt dissipation extends runtime in chest-strap heart-rate straps and armband EMG devices used by athletes. The wide 2.7 V to 5.25 V supply range supports both rechargeable Li-ion designs and direct USB charging without level shifters. The integrated lead-off detection automatically handles dry-electrode lift during high-motion exercise, improving data reliability versus discrete AFE solutions.

🧠

EEG Headband Front-End

The ADS1292RIPBS can be deployed in 2-channel EEG headband designs (dry-electrode consumer wellness products) because the 24-bit delta-sigma ADC resolves sub-microvolt EEG rhythms while the integrated PGA handles electrode-tissue offset up to +/-300 mV. The chopper-stabilized input front-end cancels 1/f noise that would otherwise dominate EEG signal chains. The 32-pin TQFP footprint enables compact headband electronics with both channels routed to forehead or temple dry electrodes.

What is the ADS1292RIPBS?
The ADS1292RIPBS is a Texas Instruments 2-channel, 24-bit analog front-end (AFE) for biopotential measurements, supplied in a 32-pin TQFP 5x5 mm package. According to the manufacturer datasheet, the 'R' suffix denotes the integrated respiration impedance channel, and the part is designed for portable ECG, EMG, and patient-monitoring designs at 740 uW typical power dissipation.
What is the input voltage range of the ADS1292RIPBS?
The ADS1292RIPBS accepts an analog supply of 2.7 V to 5.25 V on AVDD and a digital supply of 1.8 V to 3.6 V on DVDD. According to the TI datasheet, this dual-rail range supports both 3.3 V Li-ion battery powered wearables and 5 V USB-powered diagnostic instruments without external level shifters on the host interface lines.
What is the sampling rate of the ADS1292RIPBS?
The ADS1292RIPBS supports up to 8 kSPS per channel in simultaneous-sampling mode, with selectable data rates from 125 SPS to 8 kSPS. According to the TI datasheet, the simultaneous sampling of both ADCs preserves the inter-channel phase alignment required for accurate ECG interval calculations across multi-tenant intervals such as PR leads and QT intervals.
How does the ADS1292RIPBS differ from the ADS1292IPBS?
The ADS1292RIPBS integrates a respiration impedance channel that the ADS1292IPBS does not have; both share the same 32-pin TQFP 5x5 mm footprint and SPI interface, making them pin-to-pin compatible. According to the TI ADS1292 family datasheet, the R variant adds a high-frequency AC excitation source and synchronous demodulator to extract breathing waveform without an external analog multiplier IC.
Where can I download the ADS1292RIPBS datasheet?
The official ADS1292RIPBS datasheet PDF is hosted on the TI website at https://www.ti.com/lit/ds/symlink/ads1292r.pdf. According to TI product pages, a free myTI account is not required for PDF access; the document covers electrical characteristics, register map, application circuit, and layout guidelines for ECG and respiration designs.
What is the pinout of the ADS1292RIPBS?
The ADS1292RIPBS uses a 32-pin TQFP (PBS) package; according to the TI datasheet, AVDDSup pin 1, AVDD pin 2, AVSS pin 4, IN1P pin 5, IN1N pin 6, IN2P pin 7, IN2N pin 8, RLDIN pin 9, RLDREF pin 10, RLDOUT pin 11, RESP_MODN pin 13, RESP_MODP pin 14, and GPIO/DOUT/CLK/CS/SCLK/DRDY/AVSS/DVDD pins occupy the remaining positions. Refer to the manufacturer datasheet for the exact 32-pin ordering and pin 1 location.
How much power does the ADS1292RIPBS consume?
The ADS1292RIPBS consumes approximately 740 uW at 1 kSPS per channel when both channels are active, according to the TI datasheet. This makes the part suitable for battery-powered wearable ECG monitors; at 125 SPS the dissipation falls well below 500 uW, enabling multi-day continuous-wear patches using a single CR2032 coin cell when duty-cycled.
Where can I buy the ADS1292RIPBS online?
The ADS1292RIPBS is in stock at authorized distributors including DigiKey (part number 296-39038-1-ND), Mouser (595-ADS1292RIPBS), and Octopart-listed suppliers. According to DigiKey listings as of 2026-10-06, the part is shipped in a 250-piece tray with tape-and-reel variants available as ADS1292RIPBSR.
What is the price of the ADS1292RIPBS?
The ADS1292RIPBS is priced at approximately $9.50 per unit at qty 1, with volume pricing reaching $6.08 per unit at qty 1000 as of 2026-10-06. According to DigiKey and Mouser listings, tape-and-reel variants (ADS1292RIPBSR) carry a small premium over the tray 250-piece ADS1292RIPBS.
What is the lead time for the ADS1292RIPBS?
The ADS1292RIPBS ships from stock at most authorized distributors with same-day shipping available on qty-1 orders as of 2026-10-06. According to DigiKey listing data, the part is not currently flagged as having extended lead time, although the medical-grade lifecycle status means production planning is recommended for >10 k unit annual volumes.
What is the best drop-in replacement for the ADS1292RIPBS?
The ADS1292IPBS is the closest drop-in replacement for the ADS1292RIPBS, sharing the same 32-pin TQFP 5x5 mm footprint and SPI interface. According to the TI ADS1292 family datasheet, the only difference is that the ADS1292IPBS lacks the integrated respiration channel; the ECG, EMG, and lead-off functions are identical, making the swap straightforward when respiration is not needed.
ADS1292RIPBS vs ADS1192 - which is better for ECG applications?
The ADS1292RIPBS is the better choice for ECG applications requiring high DC accuracy and 24-bit resolution, while the ADS1192 uses a 16-bit ADC aimed at lower-cost heart-rate monitors. According to the TI datasheet and E2E forum responses, the ADS1292R is a true drop-in upgrade path for designers migrating from the ADS1192 to a 24-bit biopotential platform.
When should I choose the ADS1292RIPBS over the ADS1296?
The ADS1292RIPBS is the better choice when only 2 channels are required and lower power consumption is critical; the ADS1296 offers 6 channels at the expense of higher power and a different 64-pin BGA package. According to the TI datasheet, both belong to the same low-noise biopotential AFE family but are not pin-compatible due to different channel counts and footprints.
Is the ADS1292RIPBS suitable for wearable fitness monitors?
Yes, the ADS1292RIPBS is highly suitable for wearable fitness monitors due to its 740 uW typical power consumption at 1 kSPS and integrated respiration channel. According to TI application literature, the device operates from a single Li-ion cell voltage (3.7 V nominal) and integrates the PGA, ADC, reference, and oscillator, eliminating multiple external components for compact wrist-worn or patch designs.
What is the best Analog Devices equivalent for the ADS1292RIPBS?
The closest Analog Devices equivalent for the ADS1292RIPBS is the ADAS1000/ADAS1000-1 family, which provides 3 to 5 ECG channels with 24-bit resolution in a different (larger) 56-pin LFCSP package. According to distributor cross-reference data, no Analog Devices part offers a true drop-in 32-pin TQFP-2-channel alternative to the ADS1292R, so PCB redesign is required for migration.

엔지니어링 참조 데이터: ADS1292RIPBS — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the ADS1292RIPBS when designing a 2-channel ECG, EMG, or respiration design that requires 24-bit resolution and sub-milliwatt power. Choose the ADS1292IPBS as a drop-in replacement when the respiration channel is not needed (saves ~80 uW). Choose the ADS1292RIPBSR for tape-and-reel packaging required by high-volume SMT lines. Choose the ADS1192IPBS for low-cost 16-bit heart-rate monitors where 24-bit resolution is not required. All four parts share the same TQFP-32 (PBS) 5x5 mm footprint and SPI register map, enabling a single PCB layout that supports multiple product tiers.

대체품과의 비교

파라미터 이 제품 ADS1292IPBS ADS1292RIPBSR ADS1192IPBS
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package TQFP-32 (PBS) 5x5 mm TQFP-32 (PBS) 5x5 mm - same TQFP-32 (PBS) 5x5 mm - same TQFP-32 (PBS) 5x5 mm - same
Number of Channels 2 2 2 2
ADC Resolution 24-bit 24-bit 24-bit 16-bit
Respiration Channel Yes (integrated) No Yes (integrated) No
Sample Rate (max) 8 kSPS 8 kSPS 8 kSPS 8 kSPS
Analog Supply 2.7 V to 5.25 V 2.7 V to 5.25 V 2.7 V to 5.25 V 2.7 V to 5.25 V
Typical Power @ 1 kSPS 740 uW approx. 660 uW (no resp) 740 uW approx. 495 uW
Lead-Off Detection Integrated comparators Integrated comparators Integrated comparators Integrated comparators

주요 차별점

  • Integrated respiration channel (R-suffix) (vs ADS1292IPBS)
  • 24-bit resolution vs 16-bit on ADS1192 (vs ADS1192IPBS)
  • Same TQFP-32 footprint as ADS1192 family (vs ADS1192IPBS)

설계 노트

The 32-pin TQFP-32 (PBS) package has an exposed thermal pad that must be soldered to a continuous analog ground plane on the top layer. Route the digital SPI bus away from the analog IN1P/IN1N/IN2P/IN2N/RLDIN traces; place the 1 uF, 0.1 uF, and 10 uF decoupling capacitors on AVDD and DVDD as close to the supply pins as possible to suppress switching noise from the host MCU.

Estimated: at 8 kSPS with PGA gain 12, the input-referred noise is below 10 uVpp, but this assumes well-shielded electrode cables and a properly driven right-leg-drive (RLD) loop. Without RLD feedback, mains 50/60 Hz common-mode noise degrades SNR by 30-40 dB. Connect the RLD amplifier output through a 100 kohm series resistor to the patient reference electrode.

Use a ferrite bead or pi-filter between the host 3.3 V regulator and the ADS1292RIPBS DVDD pin to isolate digital switching noise from the analog front-end. Power up AVDD before DVDD by at least 1 ms to prevent digital-domain latch-up through the internal ESD structures; sequence the ADXLin voltage rails accordingly if using a power-rail sequencer IC.

Do not float any of the GPIO pins - either tie them to DGND through a 100 kohm resistor or drive them to a defined logic level. The internal oscillator requires the CLKSEL register bit to be set for default internal-oscillator operation; failing to do so leaves the part waiting for an external clock on the CLK pin, which appears as a no-data fault on DRDY.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Yes
분쟁 광물
Compliant

RoHS and REACH compliant per TI product page; MSL Level-2-260C-1 YEAR per partgenie.ai listing. AEC-Q100 not applicable (medical-grade, not automotive-grade).

데이터 검증일: 2026-10-06 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

ADS1292RIPBS ADS1292RIPBS datasheet Texas Instruments ADS1292R 2 channel 24-bit analog front end biopotential TQFP-32 AFE ECG ADS1292RIPBS wearable ECG monitor ADS1292RIPBS vs ADS1292IPBS ADS1292RIPBS drop-in replacement ADS1292RIPBS buy price what is the sample rate of ADS1292RIPBS ADS1292RIPBS pinout TQFP-32 low power ECG AFE 24-bit respiration

관련 부품 & 용어

Texas Instruments ADS1292RIPBS ADS1292IPBS ADS1292RIPBSR ADS1192IPBS analog front end AFE biopotential ECG EMG EEG delta-sigma ADC 24-bit ADC TQFP-32 TQFP right-leg drive RLD lead-off detection programmable gain amplifier PGA respiration impedance SPI MSP430F5329IPN AD8237ARMZ RoHS REACH MSL-2
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기