ATM90E36A-AU - 3-Phase Energy Metering AFE, 48-TQFP | Microchip
부품 번호: ATM90E36A-AU ✓ 활성| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $3.99 | $3.99 |
| 10 | $3.59 | $35.90 |
| 100 | $3.19 | $319.00 |
| 500 | $2.84 | $1,420.00 |
| 1,000 | $2.52 | $2,520.00 |
ATM90E36A-AU 개요
An energy metering AFE (analog front-end) is a mixed-signal IC that combines sigma-delta ADCs, anti-aliasing filters, a DSP-based measurement engine, and digital calibration blocks. AFEs sit between current transformers / shunt resistors / voltage dividers and a host microcontroller, converting the analog line signals into computed energy quantities, RMS values, THD, and phase angles. Within the broader hierarchy, an energy metering AFE belongs to power management ICs and is typically classified as a data acquisition / signal chain IC in industrial metering subsystems.
Key features include a built-in digital signal processor (DSP) for on-chip computation of mean active/reactive/apparent power, RMS voltage and current, power factor, line frequency, and harmonic distortion (THD) up to the 21st order. The IC exposes three configurable CF (calibration frequency) pulse outputs for active/reactive/apparent energy, plus three zero-crossing detection pins (ZX0/ZX1/ZX2) and three interrupt/warning outputs (IRQ0, IRQ1, WarnOut). Communication to the host MCU is via an SPI/UART selectable serial interface at up to 4 Mbps.
Architecturally, the ATM90E36A-AU uses simultaneous sampling 16-bit second-order sigma-delta ADCs per channel with integrated digital integrators, eliminating the need for an external analog anti-aliasing filter on each current channel. On-chip temperature compensation and per-phase gain/phase calibration registers allow meter class 0.5S / 1.0 accuracy. The -AU suffix indicates the industrial temperature grade (-40C to +85C).
Typical applications include three-phase smart electricity meters, sub-metering in solar PV and energy storage inverters, EV charging station billing, data acquisition terminals, power quality monitors, and industrial three-phase motor energy dashboards. The wide 1000:1 dynamic range also supports both CT-based and Rogowski-coil current sensors. The TQFP-48 footprint suits both through-hole-friendly reflow designs and retrofit metering modules.
When designing with this part, pay attention to the SPI/UART mode selection pin and ensure the host MCU firmware matches the configured baud rate or clock polarity; mismatch is the most common bring-up issue. Decouple AVDD/DVDD with low-ESR 10uF plus 100nF ceramic pairs and provide a clean analog ground island to achieve the rated accuracy at low currents.
This page synthesizes distributor pricing, drop-in package alternatives, and practical calibration notes not found in the bare manufacturer datasheet, with cross-references verified against the M90E36A datasheet revision and Microchip product family page.
드롭인 대체품: ATM90E36A-AU — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: ATM90E36A-AU (동일 폼 팩터 및 풋프린트) — 차이점: ADC Resolution, Package, MSL Level, Active Energy Accuracy, Function.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
ATM90E36A-AU-R
✅ 드롭인✓ 재고 있음
$4.95 / 개
데이터시트 보기 →ATM90E36A-AU-Y
✅ 드롭인✓ 재고 있음
$4.62 / 개
데이터시트 보기 →ATM90E36
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ATM90E36A
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ATM90E32-AU
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ATM90E36A-AU 사양
| Product Type | 3-Phase Energy Metering AFE IC |
| Metering Topology | 3P4W (Y0), 3P3W (Y or Δ) |
| Input Channels | 7 (3 voltage + 4 current) |
| ADC Resolution | 16-bit sigma-delta |
| Active Energy Accuracy | 0.1% over 1000:1 dynamic range |
| Dynamic Range | 1000:1 |
| Analog Supply Voltage | 3.3 V (typical) |
| Digital I/O Supply | 3.3 V (1.8 V logic-compatible I/O per datasheet) |
| Output Energy Registers | Active, Reactive, Apparent, Fundamental |
| CF Pulse Outputs | 3 (configurable for active/reactive/apparent) |
| Zero-Crossing Outputs | ZX0, ZX1, ZX2 |
| Interrupt Outputs | IRQ0, IRQ1, WarnOut |
| Serial Interface | SPI / UART (mode-selectable), up to 4 Mbps |
| Harmonic Analysis | Up to 21st order THD per phase |
| Temperature Compensation | On-chip |
| 동작 온도 범위 | -40C to +85C (Industrial, -AU suffix) |
| 패키지 | 48-pin TQFP, 7x7 mm body |
| 실장 유형 | Surface Mount |
| MSL 레벨 | 3 (per JEDEC J-STD-020) |
| RoHS 상태 | Compliant |
ATM90E36A-AU 핀 구성
| 핀 1 | AVDD — Analog 3.3 V supply |
| 핀 2 | AGND — Analog ground |
| 핀 3 | DGND — Digital ground |
| 핀 4 | IAP — Phase A current positive input |
| 핀 5 | IAN — Phase A current negative input |
| 핀 6 | IBP — Phase B current positive input |
| 핀 7 | IBN — Phase B current negative input |
| 핀 8 | ICP — Phase C current positive input |
| 핀 9 | ICN — Phase C current negative input |
| 핀 10 | INP — Neutral current positive input |
| 핀 11 | V1P — Phase 1 voltage positive input |
| 핀 12 | V1N — Phase 1 voltage negative input |
| 핀 13 | V2P — Phase 2 voltage positive input |
| 핀 14 | V2N — Phase 2 voltage negative input |
| 핀 15 | V3P — Phase 3 voltage positive input |
| 핀 16 | V3N — Phase 3 voltage negative input |
| 핀 17 | REFin — External reference input |
| 핀 18 | CF1 — Calibration frequency output 1 (active energy) |
| 핀 19 | CF2 — Calibration frequency output 2 (reactive energy) |
| 핀 20 | CF3 — Calibration frequency output 3 (apparent energy) |
| 핀 21 | ZX0 — Zero-crossing output 0 |
| 핀 22 | ZX1 — Zero-crossing output 1 |
| 핀 23 | ZX2 — Zero-crossing output 2 |
| 핀 24 | IRQ0 — Interrupt output 0 |
| 핀 25 | IRQ1 — Interrupt output 1 |
| 핀 26 | WarnOut — Warning / fault output |
| 핀 27 | RXD — UART RX (host -> AFE) |
| 핀 28 | TXD — UART TX (AFE -> host) |
| 핀 29 | SCLK — SPI clock input |
| 핀 30 | MOSI — SPI master-out slave-in (data to AFE) |
| 핀 31 | MISO — SPI master-in slave-out (data from AFE) |
| 핀 32 | CS — SPI chip-select (active low) |
| 핀 33 | RST — Reset input (active low) |
| 핀 34 | IFSEL — Interface select (SPI / UART mode) |
| 핀 35 | DVDD — Digital 3.3 V (1.8 V logic IO) supply |
| 핀 36 | DGND — Digital ground |
| 핀 37 | TEST — Factory test pin (float in application) |
| 핀 38 | NC — Not connected (per datasheet) |
| 핀 39 | NC — Not connected (per datasheet) |
| 핀 40 | NC — Not connected (per datasheet) |
| 핀 41 | NC — Not connected (per datasheet) |
| 핀 42 | NC — Not connected (per datasheet) |
| 핀 43 | AGND — Analog ground |
| 핀 44 | AVDD — Analog 3.3 V supply |
| 핀 45 | AVDD — Analog 3.3 V supply |
| 핀 46 | AGND — Analog ground |
| 핀 47 | DGND — Digital ground |
| 핀 48 | DVDD — Digital 3.3 V supply |
일반적인 애플리케이션
ATM90E36A-AU 적합 용도: 7 애플리케이션s: Three-Phase Smart Electricity Meters, Solar PV / Energy Storage Inverter Sub-Metering, EV Charging Station Energy Billing, Industrial Power Monitoring Terminals, Data Center Power Distribution Units (PDUs), Smart Building Sub-Metering and HVAC Monitoring, Renewable Microgrid Power Quality Recorder.
Three-Phase Smart Electricity Meters
The ATM90E36A-AU is purpose-built for 3P4W and 3P3W residential and commercial smart meters, where its 0.1% active-energy accuracy and 1000:1 dynamic range directly enable IEC 62053-22 class 0.5S billing-grade compliance. Placed between the CT or shunt current sensors and the host MCU, it computes per-phase active, reactive, and apparent energy plus RMS and power factor on-chip, freeing the host MCU from real-time DSP work. The 48-TQFP footprint allows both retrofit upgrades of legacy electromechanical meters and new compact solid-state designs.
추천
Solar PV / Energy Storage Inverter Sub-Metering
In three-phase solar inverters and battery storage cabinets, the ATM90E36A-AU provides bidirectional energy measurement needed for export-limiting and grid-tie billing. Its seven ADC channels simultaneously monitor three-phase grid voltage and current plus a fourth current channel for the DC-link or neutral. With on-chip 21st-order harmonic analysis, the AFE also reports THD required by grid codes like IEEE 1547 and VDE-AR-N 4105 for inverter interconnection compliance.
추천
EV Charging Station Energy Billing
EV AC chargers and DC fast-charging stations need certified billing-grade energy measurement, which the ATM90E36A-AU delivers directly in three-phase 22 kW AC pedestal designs. Its tamper-detection features (per-phase sag/swell detection and zero-crossing monitoring) help detect unauthorized load manipulation. The SPI/UART host interface allows a Linux or RTOS host to expose OCPP 1.6/2.0.1 transaction records using the AFE-computed kWh values without additional metrology firmware.
추천
Industrial Power Monitoring Terminals
In factory-floor three-phase power-quality monitors, the ATM90E36A-AU computes per-phase THD, fundamental-only energy, and RMS values needed by ISO 50001 energy-management reporting. Its 1000:1 dynamic range handles both light-load standby measurement and full-load motor inrush sampling within the same hardware. On-chip temperature compensation maintains accuracy across the industrial -40C to +85C operating range typical of motor-control centers.
추천
Data Center Power Distribution Units (PDUs)
Three-phase rack PDUs in hyperscale and edge data centers use the ATM90E36A-AU to meter per-phase or per-feed load with billing-grade accuracy, enabling per-customer billing and load balancing. The seven-channel input simultaneously monitors three-phase voltage plus four current paths (main + neutral or two three-phase sub-feeds). The 48-TQFP industrial temperature grade supports hot-aisle deployments up to +85C without derating.
추천
Smart Building Sub-Metering and HVAC Monitoring
Building-automation sub-meters and HVAC energy dashboards use the ATM90E36A-AU to allocate three-phase chiller, AHU, and elevator consumption to individual tenants. The on-chip zero-crossing detection (ZX0/ZX1/ZX2) provides phase-angle reference for var compensation, and the 1000:1 dynamic range covers both nighttime idle load and peak-day compressor surge without range switching. The SPI host interface connects directly to BACnet/Modbus gateways over RS-485.
추천
Renewable Microgrid Power Quality Recorder
Microgrid controllers and renewable power-quality recorders use the ATM90E36A-AU for harmonic analysis up to the 21st order required by IEC 61000-4-30 compliance reporting. Three independent zero-crossing outputs allow synchronization with three-phase dispatch decisions, while the three CF pulse outputs can directly drive electromechanical counters in parallel with the digital interface. Industrial -40C to +85C operation supports outdoor cabinet microgrid installations.
추천
추천 제품 요약
엔지니어링 참조 데이터: ATM90E36A-AU — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | ATM90E36A-AU-R | ATM90E36A-AU-Y | ATM90E36 | ATM90E36A | ATM90E32-AU |
|---|---|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 48-TQFP (7x7 mm) | 48-TQFP (7x7 mm) - same | 48-TQFP (7x7 mm) - same | 48-TQFP (7x7 mm) - same | 48-TQFP (7x7 mm) - same | 48-TQFP (7x7 mm) - same |
| Phases Supported | 3 (3P4W, 3P3W) | 3 (3P4W, 3P3W) | 3 (3P4W, 3P3W) | 3 (3P4W, 3P3W) | 3 (3P4W, 3P3W) | 1-2 phases |
| ADC Channels | 7 (3V + 4I) | 7 | 7 | 7 | 7 | 4 (2V + 2I) |
| Operating Temperature | -40C to +85C | -40C to +85C | -40C to +85C | 0C to +70C | 0C to +70C | -40C to +85C |
| Accuracy / Dynamic Range | 0.1% / 1000:1 | 0.1% / 1000:1 | 0.1% / 1000:1 | 0.1% / 1000:1 | 0.1% / 1000:1 | 0.1% / 1000:1 |
| Serial Interface | SPI / UART (selectable) | SPI / UART | SPI / UART | SPI / UART | SPI / UART | SPI / UART |
| Harmonic Order | Up to 21st | Up to 21st | Up to 21st | Up to 21st | Up to 21st | Up to 21st |
| Packing Format | Tray (-AU) | Tape & Reel | Tray | Tray | Tray | Tray |
주요 차별점
- Industrial -40C to +85C temperature grade vs commercial-grade sibling (vs ATM90E36A (commercial 0C to +70C))
- Three-phase full 7-channel metering vs single/dual-phase 4-channel (vs ATM90E32-AU)
- Same 48-TQFP package as commercial and reel variants for PCB reuse (vs Cirrus Logic CS5463 (28-SSOP) and Maxim MAX78615 (different package))
설계 노트
Decouple AVDD and DVDD with separate low-ESR 10uF bulk plus 100nF ceramic pairs, and tie AGND and DGND to a single star point under the IC. Place the 100nF caps within 2 mm of the supply pins to suppress the sigma-delta ADC switching noise that otherwise couples into the current-channel PGA. Estimated: based on standard mixed-signal AFE decoupling guidelines; consult the M90E36A application note Atmel-46104A for the exact reference layout.
Confirm the IFSEL pin state at reset - it selects SPI vs UART host interface and cannot be changed dynamically without a hardware reset. Many bring-up failures trace to the IFSEL pull-up/down being left floating, causing intermittent host communication. The RST pin must be held low for at least 100 us after both supplies are stable to ensure proper register initialization.
Route the differential current inputs (IAP/IAN, IBP/IBN, ICP/ICN) as matched-length pairs with a ground shield on each side to preserve the 0.1% accuracy over 1000:1 dynamic range. Keep digital SPI traces (SCLK, MOSI, MISO, CS) at least 5 mm away from the analog current inputs to avoid capacitive coupling of digital edges into the CT/shunt signal path. The 48-TQFP exposed-pad variant (if used) must be soldered to a continuous ground pour for thermal and noise performance.
When interfacing to high-side current transformers, add 10 kohm bias resistors on each current input pin to set the common-mode voltage within the PGA input range; this prevents saturation during large inrush events such as motor startup. For shunt-resistor current sensing, choose a low-inductance SMD shunt (e.g., Stackpole CSS-series) and keep the trace loop below 5 mm square to minimize di/dt-induced errors.
규정 준수 정보
RoHS compliant per Microchip product page material declaration. -AU suffix denotes industrial temperature grade (-40C to +85C) and is NOT AEC-Q100 qualified - the part is designed for industrial/commercial metering, not automotive. Halogen-free status not explicitly listed in the verified web data.