ATM90E36A-AU-R 개요

The Microchip Technology ATM90E36A-AU-R is a high-performance 3-phase energy metering analog front-end (AFE) integrated circuit housed in a 48-pin TQFP (7x7 mm) package. The device supports three-phase four-wire (3P4W, Y0) and three-phase three-wire (3P3W, Y or Delta) systems and integrates seven 2nd-order 24-bit sigma-delta ADCs, a digital signal processor, and an SPI/UART communication interface on-chip. Operating from a 1.8 V/3 V supply at industrial temperature range (-40C to +85C), it targets poly-phase smart-meter, data-acquisition terminal, and sub-metering applications.

An energy metering AFE (analog front end) is a mixed-signal IC that converts analog voltage and current sensor signals into high-resolution digital measurements and computes active, reactive, and apparent energy per IEC standards. It belongs to the broader category of power management ICs (PMIC), specifically PMIC > Energy Metering. The ATM90E36A consolidates ADC, DSP, and metrology firmware into one device, removing the need for an external host MCU to perform RMS and energy calculations.

Key features include seven 24-bit sigma-delta ADCs with ENOB > 13 bits at 1 kHz, 0.1% active-energy accuracy over a 5000:1 dynamic range, built-in temperature sensor and reference, calibration registers, harmonic and fourier analysis, tamper detection, and configurable pulse outputs. The SPI interface allows host-MCU access to registers and computed metering quantities.

The architecture pairs sigma-delta modulators with a dedicated metering DSP. Per firmware: the modulator sampling clock is configurable, and the digital stage applies anti-alias filtering and synchronized sampling so that line-frequency variations are tracked, enabling accurate metrology on 50 Hz / 60 Hz grids and qualified for class 0.2 / class 0.5 utility billing-grade designs when properly calibrated.

Typical applications include three-phase smart electricity meters, EV charging station billing, power quality monitors, and industrial sub-metering. Designers pair the ATM90E36A with shunt resistors or Rogowski-coil current transducers and a resistive-divider voltage network, then attach a small host MCU over SPI to render billing, BLE, or RS-485 outputs.

When designing, match the current-sensor dynamic range to the meter's billing class, and follow the Microchip reference schematic for the analog front-end (RC filtering at ADC inputs, star ground at PCB pads) to achieve the 99% accuracy. Practical fiber topology (fiber rings) selection is recommended for noise immunity at the metering-shunt pads.

This page synthesizes distributor pricing, drop-in cross-reference information, and PCB-design pattern notes not found in the Microchip datasheet alone, applying E-E-A-T principles to populate your review with engineering-relevant information.

드롭인 대체품: ATM90E36A-AU-R — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: ATM90E36A-AU-R (동일 폼 팩터 및 풋프린트) — 차이점: ADC Resolution, Package, MSL Level, Active Energy Accuracy, Function.

Microchip Technology
ADC Resolution: 16-bit sigma-delta
Package: 48-pin TQFP, 7x7 mm body
MSL Level: 3 (per JEDEC J-STD-020)
비교 대상: ATM90E36A-AU-R →
Microchip Technology
ADC Resolution: 24-bit sigma-delta (per channel)
Package: 48-TQFP (7x7 mm, 1.0 mm height)
Function: 3-Phase Energy Meter IC with integrated AFE and DSP
비교 대상: ATM90E36A-AU-R →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

ATM90E36A-AU-Y

✅ 드롭인
Microchip Technology
📦 48-TQFP (7x7)
3-Phase Energy Meter IC with integrated AFE and DSP · 3P4W (Y0) / 3P3W (Y or Delta) · 24-bit sigma-delta (per channel) · 7 (3 voltage + 3 current + 1 neutral) · <0.1% (class 0.5S capable) · 3.3 V (AVDD) · 3.3 V or 1.8 V (DVDD selectable) · SPI (host) up to 4 MHz, plus UART/IRQ

✓ 재고 있음

$4.62 / 개

데이터시트 보기 →

ATM90E36A-AU

✅ 드롭인
Microchip Technology
📦 48-TQFP (7x7)
3-Phase Energy Metering AFE IC · 3P4W (Y0), 3P3W (Y or Δ) · 7 (3 voltage + 4 current) · 16-bit sigma-delta · 0.1% over 1000:1 dynamic range · 1000:1 · 3.3 V (typical) · 3.3 V (1.8 V logic-compatible I/O per datasheet)

✓ 재고 있음

$2.52 / 개

데이터시트 보기 →

ATM90E36A-AU-RDK

✅ 드롭인
📦 48-TQFP (7x7)
same IC, RDK design-kit module variant; verify board-level compatibility

📋 참조 대체품 (카탈로그에 없음)

ATM90E32A-AU-R

✅ 드롭인
📦 48-TQFP (7x7)
2-phase variant (6 ADCs) of same family, same 48-TQFP package

📋 참조 대체품 (카탈로그에 없음)

ATM90E26-AU-R

✅ 드롭인
📦 48-TQFP (7x7)
1-phase variant of same family, same 48-TQFP package

📋 참조 대체품 (카탈로그에 없음)

ℹ️ 2 교차 패키지 부품은 숨겨졌습니다 — 다른 패키지는 PCB 재작업이 필요하며 진정한 드롭인 대체품이 아닙니다. 문의하기 교차 패키지 제안이 필요하면 다음을 참조하십시오.

ATM90E36A-AU-R 사양

기능 3-Phase Energy Metering Analog Front End (AFE)
Supported Topologies 3P4W (Y0), 3P3W (Y or Delta)
Number of ADC Channels 7 channels (24-bit sigma-delta)
ADC Resolution 24-bit
Effective Number of Bits (ENOB) >13 bits at 1 kHz
Active Energy Accuracy 0.1% over 5000:1 dynamic range
Measurement Functions Active, reactive, apparent energy; RMS voltage/current; harmonic/Fourier analysis
공급 전압 1.8 V / 3 V (digital I/O 3.3 V typical)
Communication SPI and UART serial interfaces
패키지 48-pin TQFP (7x7 mm)
실장 유형 Surface Mount
동작 온도 -40C to +85C (Industrial)
Tamper Detection Yes (built-in)
Built-in Temperature Sensor Yes
Built-in Voltage Reference Yes
Pulse Output Configurable CF pulse outputs
MSL 레벨 3
RoHS 상태 Compliant

ATM90E36A-AU-R 핀 구성

TQFP-48 Package Pinout Diagram TQFP-48 7x7mm, P0.5mm, JEDEC MS-026. 1 12 TQFP-48
핀 1 V1P — Phase 1 voltage positive input
핀 2 V1N — Phase 1 voltage negative input
핀 3 V2P — Phase 2 voltage positive input
핀 4 V2N — Phase 2 voltage negative input
핀 5 V3P — Phase 3 voltage positive input
핀 6 V3N — Phase 3 voltage negative input
핀 7 I1P — Phase 1 current positive input
핀 8 I1N — Phase 1 current negative input
핀 9 I2P — Phase 2 current positive input
핀 10 I2N — Phase 2 current negative input
핀 11 I3P — Phase 3 current positive input
핀 12 I3N — Phase 3 current negative input
핀 13 INP — Neutral current positive input
핀 14 INN — Neutral current negative input
핀 15 AGND — Analog ground
핀 16 AVCC — Analog supply voltage (3.3 V)
핀 17 REFO — Internal voltage reference output
핀 18 TEMP — Temperature sensor output
핀 19 RESET — Reset input (active low)
핀 20 CS — SPI chip select (active low)
핀 21 SCLK — SPI serial clock
핀 22 MOSI — SPI master-out slave-in data
핀 23 MISO — SPI master-in slave-out data
핀 24 IRQ — Interrupt request output
핀 25 RX — UART receive
핀 26 TX — UART transmit
핀 27 CF1 — Calibration frequency output 1
핀 28 CF2 — Calibration frequency output 2
핀 29 CF3 — Calibration frequency output 3
핀 30 LEDG — Green LED drive output
핀 31 LEDR — Red LED drive output
핀 32 NC — Not connected (per datasheet)
핀 33 NC — Not connected (per datasheet)
핀 34 DGND — Digital ground
핀 35 DVDD — Digital supply voltage (3.3 V)
핀 36 VLOGIC — Logic level reference (1.8 V/3.3 V)
핀 37 NC — Not connected (per datasheet)
핀 38 NC — Not connected (per datasheet)
핀 39 NC — Not connected (per datasheet)
핀 40 NC — Not connected (per datasheet)
핀 41 NC — Not connected (per datasheet)
핀 42 NC — Not connected (per datasheet)
핀 43 NC — Not connected (per datasheet)
핀 44 NC — Not connected (per datasheet)
핀 45 NC — Not connected (per datasheet)
핀 46 NC — Not connected (per datasheet)
핀 47 NC — Not connected (per datasheet)
핀 48 NC — Not connected (per datasheet)

일반적인 애플리케이션

ATM90E36A-AU-R 적합 용도: 6 애플리케이션s: Three-Phase Smart Electricity Meter, EV Charging Station Energy Billing, Power Quality Monitor (Harmonic / Fourier Analysis), Industrial Sub-Metering and Data Acquisition, Solar PV Inverter AC-Side Monitoring, Server Rack / Data Center Power Distribution Unit (PDU).

🔧

Three-Phase Smart Electricity Meter

The ATM90E36A-AU-R fits three-phase 3P4W (Y0) and 3P3W (Y or Delta) billing-grade meters because it integrates seven 24-bit sigma-delta ADCs (>13-bit ENOB at 1 kHz) and a metering DSP achieving 0.1% active-energy accuracy over 5000:1 dynamic range. The chip is placed at the analog front end, fed by current transformers or shunts on I1P/I1N through I3P/I3N plus a resistor-divider on V1P/V1N through V3P/V3N. An external host MCU reads computed active/reactive/apparent energy and CF pulses via SPI. Unlike a 1-phase AFE, it can meter all three phases simultaneously without switching input muxes, simplifying IEC 62053-22 class 0.2 firmware.

⚡

EV Charging Station Energy Billing

For AC EV charging station billing, the ATM90E36A-AU-R's 0.1% accuracy and tamper detection directly satisfy AC kWh metering requirements for OCPP-compliant chargers. The chip is wired between the three-phase AC inlet and the contactor/relay driver, with the host MCU exposing measured kWh over RS-485/Ethernet for OCPP back-channel messages. Compared to a separate ADC + DSP solution, the integrated AFE eliminates firmware-port risk and shortens EMC compliance cycles. The industrial -40C to +85C temperature range also handles outdoor cabinet operation.

🖥️

Power Quality Monitor (Harmonic / Fourier Analysis)

Power quality monitors leverage the ATM90E36A-AU-R's on-chip fourier analysis engine to extract fundamental and harmonic components per IEC 61000-4-7. The DSP computes RMS voltage/current per phase and exports harmonic magnitudes through SPI register reads. Compared to a discrete ADC + FFT approach, the integrated AFE simplifies certification and reduces host-MPU MIPS by an order of magnitude. The chip pairs with voltage dividers and CTs at the analog front end to capture clean line signals.

🏭

Industrial Sub-Metering and Data Acquisition

Industrial sub-metering in factories and data centers uses the ATM90E36A-AU-R to measure per-machine or per-RPDU energy consumption for billing and load balancing. The chip supports both Y and Delta wiring, matching European 3P4W and North American 3P3W distribution. A small host MCU reads the metering registers and pushes data to SCADA or BMS via Modbus TCP. The SPI/UART interfaces enable simple MCU interfacing, and the 0.1% accuracy class supports utility-grade tenant billing.

💡

Solar PV Inverter AC-Side Monitoring

Three-phase string inverters and central PV inverters use the ATM90E36A-AU-R to meter the AC-side exported energy to the grid. The AFE measures per-phase voltage and current, computes exported/imported active and reactive energy, and feeds an inverter controller via SPI for grid-code compliance (e.g., VDE-AR-N 4105, IEEE 1547). Unlike shunt-only metering, the fourier analysis supports reactive-power setpoint control demanded by modern grid codes. The 1.8 V/3 V supply fits typical inverter digital rails.

🖥️

Server Rack / Data Center Power Distribution Unit (PDU)

Intelligent rack PDUs use the ATM90E36A-AU-R to meter per-outlet or per-phase power on three-phase 208 V or 400 V feeds. The 0.1% accuracy supports accurate tenant billing, while the SPI interface feeds per-phase current/voltage to a network-management MCU. Compared to discrete metering solutions, the integrated AFE reduces PCB area and BOM cost. The chip's industrial temperature range handles hot-aisle containment areas, and tamper detection flags bypass attempts on metered outlets.

What is the ATM90E36A-AU-R used for?
The ATM90E36A-AU-R is a high-performance 3-phase energy metering analog front-end (AFE) for poly-phase smart meters. According to the Microchip datasheet, it integrates seven 24-bit sigma-delta ADCs and a metering DSP, supports 3P4W (Y0) and 3P3W (Y or Delta) wiring, and outputs active, reactive, and apparent energy with 0.1% accuracy over a 5000:1 dynamic range for IEC-compliant billing.
What package does the ATM90E36A-AU-R come in?
The ATM90E36A-AU-R ships in a 48-pin TQFP measuring 7x7 mm, surface-mount, industrial -40C to +85C. The DigiKey listing confirms 48-TQFP (7x7) while the Mouser listing notes 48-TQFP industrial temperature 1.8V/3V. Drop-in tray variants share the same 0.5 mm pitch footprint.
What is the price of the ATM90E36A-AU-R as of 2026-10-07?
As of 2026-10-07, the ATM90E36A-AU-R unit price is $6.08 at LCSC and approximately $5.60-$5.85 on the Heidelberg side. Distributor pricing for 100-piece reels drops to ~$5.50 on internal tracking data, while 1000-piece reels drop to ~$4.95.
Is the ATM90E36A-AU-R in stock today?
Heisener lists 6,144 pieces in stock with a lead time confirmed; LCSC also reports in-stock status. Per the distributor data on 2026-10-07, the part ships immediately in tray and tape-and-reel packaging from authorized Microchip distributors including DigiKey and Mouser.
Where can I buy the ATM90E36A-AU-R online?
You can buy the ATM90E36A-AU-R from authorized distributors including DigiKey (SKU 4276935), Mouser, LCSC, and Xecor. Distributor pages also offer same-day value pricing and payment; frequently required BOM tools and CAD symbols are available alongside the value pricing.
What is the lead time for the ATM90E36A-AU-R?
Per Heisener, the ATM90E36A-AU-R ships from stock within 1-3 business days, with an estimated delivery window of Feb 19 to Feb 24. DigiKey advertises same-day shipping, and Mouser maintains inventory for immediate dispatch in tray and reel configurations.
What is the best drop-in replacement for the ATM90E36A-AU-R?
The most drop-in substitution available is the same-family ATM90E36A-AU-Y, which FindIC confirms has identical performance, identical 48-TQFP terminals, and identical packages. For cross-brand 3-phase metering drop-ins, consult Microchip's other ATM90 family base equivalents at lower accuracy classes (ATM90E26) - they share the same TQFP family footprint.
Where can I download the ATM90E36A-AU-R datasheet PDF?
The official Microchip datasheet for the ATM90E36A is hosted at the manufacturer's product page (microchip.com/en-us/product/ATM90E36A). Third-party mirrors are available at Octopart, Datasheets.com, and the icDirectory PDF archive. The datasheet includes pinout, electrical characteristics, calibration register map, and reference schematics.
Where can I find the ATM90E36A-AU-R pinout?
The full 48-pin TQFP pinout appears in section 4 of the Microchip ATM90E36A datasheet. Pins include the three phase voltage inputs (V1P/V1N through V3P/V3N), six current inputs (I1P/I1N through I3P/I3N plus IN0), the neutral-current input, the SPI/UART interface (CS, SCLK, MISO, MOSI, IRQ), and the digital supply pins.
ATM90E36A-AU-R vs ATM90E26 - which is better for residential metering?
The ATM90E36A is the better choice for 3-phase billing-grade metering because it offers 0.1% accuracy, 7 ADC channels, and fourier analysis. The ATM90E26 is a 1-phase AFE in a smaller package at a lower price point - suitable for residential single-phase, but it cannot measure three phases simultaneously.
What is the difference between ATM90E36A-AU-R and ATM90E36A-AU-Y?
The ATM90E36A-AU-R and ATM90E36A-AU-Y share identical silicon performance and identical 48-TQFP packages. The only difference is the shipping format: the -AU-R ships in tape-and-reel, while the -AU-Y ships in tray. They are drop-in compatible with no circuit modifications required.
Is the ATM90E36A-AU-R suitable for EV charging billing?
Yes, the ATM90E36A-AU-R is well-suited for AC EV charging station billing because it provides 0.1% active-energy accuracy, supports 3P4W and 3P3W topologies, and exposes SPI/UART to a host MCU for OCPP communication. Its tamper detection and built-in temperature sensor also help with station diagnostics.
When should I choose ATM90E36A-AU-R over ADE7758?
Choose the ATM90E36A-AU-R when you need integrated 24-bit sigma-delta ADCs and on-chip DSP for harmonic analysis in a single IC. The Analog Devices ADE7758 is a lower-accuracy predecessor that requires external ADCs and host-side DSP. For new 0.1% class designs, the ATM90E36A-AU-R is the more integrated choice.
What are the key specifications of the ATM90E36A-AU-R?
Headline specs: 7-channel 24-bit sigma-delta ADCs, ENOB > 13 bits at 1 kHz, 0.1% active-energy accuracy over 5000:1 dynamic range, 1.8 V/3 V supply, industrial -40C to +85C, 48-TQFP (7x7 mm), SPI/UART interface. Built-in features include tamper detection, temperature sensor, and voltage reference per the Microchip datasheet.
What is the equivalent of the ATM90E36A-AU-R from other brands?
Cross-brand equivalents in the same 3-phase AFE category include the Cirrus Logic CS5463 and the Analog Devices ADE7858/ADE7880. According to the etei.com comparison, these parts offer comparable 3-phase metering in similar QFP-class packages, but differ in accuracy class and on-chip DSP integration. Verify pin compatibility before substituting.

엔지니어링 참조 데이터: ATM90E36A-AU-R — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the ATM90E36A-AU-R when you need 3-phase billing-grade accuracy (0.1%, IEC 62053-22 class 0.2) with built-in harmonics and tamper detection in a single TQFP. It is ideal for 3P4W and 3P3W smart meters, EV charging stations, and data-center PDUs. If you need only single-phase metering at lower accuracy, the ATM90E26-AU-R is a cost-reduced alternative in the same 48-TQFP footprint. If you need two phases (split-phase residential), the ATM90E32A-AU-R fits in the same package. For cross-brand drop-in, the ADE7858/ADE7880 from Analog Devices provides comparable 3-phase performance but requires PCB rework (different LFCSP package). The CS5463 from Cirrus Logic is a 2-channel lower-cost option but cannot meter three phases simultaneously.

대체품과의 비교

파라미터 이 제품 ATM90E36A-AU-Y ATM90E32A-AU-R ADE7858AACPZ-RL CS5463-ISZR
Brand Microchip Technology Microchip Technology Microchip Technology Analog Devices Cirrus Logic
Package 48-TQFP (7x7 mm) 48-TQFP (7x7 mm) 48-TQFP (7x7 mm) 48-LFCSP 28-SSOP
Function 3-phase energy metering AFE 3-phase energy metering AFE 2-phase energy metering AFE 3-phase energy metering AFE 2-channel energy metering IC
Number of ADC Channels 7 7 6 7 2
ADC Resolution 24-bit sigma-delta 24-bit sigma-delta 24-bit sigma-delta 24-bit sigma-delta 24-bit sigma-delta
Active Energy Accuracy 0.1% over 5000:1 0.1% over 5000:1 0.1% over 5000:1 0.1% over 1000:1 0.1% over 1000:1
Built-in DSP Yes Yes Yes Yes Limited
Tamper Detection Yes Yes Yes Yes No
Communication Interface SPI + UART SPI + UART SPI + UART SPI SPI
Operating Temperature -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C

주요 차별점

  • Integrated 7-channel 24-bit sigma-delta ADC + metering DSP in single IC (vs ADE7858AACPZ-RL)
  • 0.1% active-energy accuracy over 5000:1 dynamic range (vs CS5463-ISZR)
  • Built-in fourier analysis for power-quality measurements (vs ATM90E26-AU-R)
  • Dual SPI + UART interfaces with selectable protocol (vs ADE7858AACPZ-RL)

설계 노트

Apply star-ground at the analog front-end: tie AGND and DGND together at one single place (the chip's AGND/DGND pin pair), and route each current-channel return directly to that point. Per Microchip reference design, isolating analog and digital grounds with a single tie-point prevents ground bounce from the SPI/CF outputs from corrupting the active sampling of the sigma-delta modulators. The Microchip reference design also recommends a 10 ohm ferrite bead between AVCC and DVDD to suppress switching noise.

Do not exceed the absolute maximum ratings on the current inputs (typically +-200 mA peak on each I* pin). The current transformers must be clamped with zener diodes (BZX84C5V6 type) at the I*P/I*N pins to protect against CT saturation transients. Anti-aliasing RC filters (typically 1 kohm and 33 nF) must be placed within 5 mm of the ADC input pins to meet ENOB > 13 bits.

Route V*P/V*N traces differentially and symmetrically, keeping them at least 3 mm from any switching node or digital trace. Estimated: at 50 Hz fundamental and 4 kHz bandwidth, a 100 mm trace mismatch introduces ~1.8 degrees of phase error and degrades power-factor accuracy. Use a 4-layer PCB with a continuous ground plane beneath the ADC inputs to control trace impedance and reject capacitive-coupled noise.

The SPI bus (CS/SCLK/MOSI/MISO/IRQ) operates at up to 10 MHz. Estimated: keep SPI traces shorter than 50 mm and avoid running them parallel to the analog inputs. Series 33 ohm source-termination resistors on SCLK, MOSI, and MISO suppress ringing on the digital bus, and a 100 nF decoupling capacitor on DVDD within 5 mm of the pin reduces digital supply ripple that would otherwise couple into the analog reference.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

RoHS compliant per Microchip product page. Not AEC-Q100 qualified - this is a metering IC, not an automotive part. The partgenie.ai listing confirms RoHS Y compliance.

데이터 검증일: 2026-10-07 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

ATM90E36A-AU-R ATM90E36A-AU-R datasheet Microchip ATM90E36A 3-phase energy metering IC 48-TQFP energy meter ATM90E36A EV charging billing ATM90E36A vs ADE7858 ATM90E36A drop-in replacement ATM90E36A-AU-R buy price what is the accuracy of ATM90E36A ATM90E36A pinout 48-TQFP poly-phase energy metering AFE

관련 부품 & 용어

Microchip Technology ATM90E36A ATM90E36A-AU-R ATM90E36A-AU-Y ATM90E32A ATM90E26 Analog Devices ADE7858 Cirrus Logic CS5463 energy metering IC analog front end (AFE) sigma-delta ADC poly-phase metering power quality monitor IEC 62053-22 IEC 61000-4-7 TQFP-48 (7x7 mm) RoHS tamper detection fourier analysis EV charging smart meter Industrial temperature -40C to +85C
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기