DS90CR215MTD - 21-Bit 66MHz LVDS Transmitter | Texas Instruments
부품 번호: DS90CR215MTD ✓ 활성DS90CR215MTD 개요
An LVDS transmitter, also called an LVDS driver, converts low-voltage digital signals into a balanced differential pair. This differential signaling method improves noise immunity by rejecting common-mode noise and allowing the receiver to detect smaller voltage differences. In the DS90CR215, the data-strobe architecture carries 21 data bits together with a clock signal, placing the transmitter within the parallel-interface and serial-link hierarchy of communication ICs.
Principal characteristics include 3.3 V operation, 21-bit parallel data handling, a 66 MHz maximum signaling rate, and a 48-TSSOP package. The manufacturer identifies the device as a rising-edge data-strobe LVDS interface IC. Its operating temperature range extends from -40 °C to +85 °C, supporting industrial-temperature equipment. The package is intended for surface-mount assembly and provides a relatively high pin count for the parallel data and differential output connections.
The DS90CR215MTD is designed for systems in which a processor, FPGA, display controller, or data acquisition engine must communicate over a fast, noise-resistant differential link. Because the link uses balanced signaling, it can operate in environments containing switching equipment, long internal cable runs, or multiple high-speed digital sources where single-ended routing would be more susceptible to interference.
Typical uses include industrial control cabinets, test and measurement systems, medical monitoring equipment, instrumentation, video-processing modules, and embedded data acquisition. The 66 MHz channel-link rate supports high-throughput point-to-point transfers, while the 21-bit parallel interface reduces the number of package pins required for data compared with a fully serialized interface. Matching receiver characteristics and controlled trace geometry remain important for reliable operation.
For PCB design, treat the differential data and clock outputs as controlled-impedance nets, place the device close to the connector or receiving interface, and route the differential pair as a matched pair without plane splits or excessive stubs. Verify power and ground distribution, follow the manufacturer's decoupling recommendations, and confirm that the receiver and cable meet the link's timing and termination requirements.
This page consolidates the manufacturer's product characteristics, package information, operating limits, sourcing links, and practical interface guidance into one engineering reference. It also highlights the limited availability of verified pin-compatible substitutes and distinguishes exact lead-finish variants from parts that cannot replace the transmitter function.
드롭인 대체품: DS90CR215MTD — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
DS90CR215MTD/NOPB
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
DS90CR215MTD 사양
| Product Type | LVDS rising-edge data-strobe transmitter |
| 공급 전압 | 3.3 V |
| Parallel Data Width | 21 bits |
| 최대 클록 주파수 | 66 MHz |
| Signal Type | LVDS differential signaling |
| Data-Strobe Edge | Rising edge |
| 패키지 | 48-TSSOP |
| 실장 유형 | Surface mount |
| 동작 온도 범위 | -40 °C to +85 °C |
| Product Category | Interface IC |
DS90CR215MTD 48-tssop 핀 구성 가이드
DS90CR215MTD(48-tssop 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: DS90CR215MTD.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
DS90CR215MTD 적합 용도: 6 애플리케이션s: FPGA-to-FPGA Board-Level Data Link, Industrial Control Cabinet Data Transfer, Data Acquisition and Instrumentation, Medical Monitoring Equipment, Video Processing Module Interconnect, Test and Measurement Equipment.
FPGA-to-FPGA Board-Level Data Link
The DS90CR215MTD suits high-speed transfers between FPGA-based modules because it accepts a 21-bit parallel data-strobe bus and converts it into LVDS differential signaling at up to 66 MHz. Differential outputs improve common-mode noise rejection on long routed pairs and reduce radiated emissions compared with many single-ended implementations. Place the transmitter close to the receiving FPGA, route data and strobe pairs with matched geometry, and maintain a continuous reference plane. The design must still account for clock-to-data skew, receiver setup and hold requirements, and the loss introduced by connectors or an inter-board cable.
추천
Industrial Control Cabinet Data Transfer
The DS90CR215MTD is appropriate for transferring control and status data between industrial modules when the board environment contains switching converters and relay drive circuitry. Its 21-bit parallel input reduces the number of single-ended nets crossing a noisy enclosure boundary, while the LVDS outputs provide a balanced signal that rejects common-mode disturbance. The -40 °C to +85 °C operating range supports industrial-temperature installations. Validate EMC performance with the final receiver, cable, connector, and enclosure because compliance depends on the assembled product rather than the transmitter alone.
추천
Data Acquisition and Instrumentation
The DS90CR215MTD can carry a dense 21-bit measurement bus from an acquisition front end to a processing module at a 66 MHz clock rate. Balanced LVDS signaling helps preserve data integrity in instrument enclosures that contain switching regulators, amplifiers, and long inter-board connections. The transmitter is best placed adjacent to the receiver so that only the intended differential link traverses the noisy environment. Designers should verify converter settling time, analog-to-digital converter latency, clock distribution, and channel skew before treating the link as transparent to the source data.
추천
Medical Monitoring Equipment
The DS90CR215MTD may be used inside medical monitoring equipment to transfer sampled data from a processing board to a display, storage module, or remote interface. The differential link can reduce susceptibility to interference compared with a wide single-ended bus, while the 21-bit width and 66 MHz rate accommodate dense digital traffic. The device's industrial temperature range does not itself establish medical-product compliance. Confirmation of electrical safety, EMC, risk management, and system validation remains the responsibility of the finished equipment designer.
추천
Video Processing Module Interconnect
The DS90CR215MTD fits point-to-point video-processing interconnects where parallel pixel, control, or configuration data must cross a board boundary at up to 66 MHz. Its 21-bit parallel-to-LVDS conversion reduces the number of package pins needed for wide parallel traffic and provides a balanced output that behaves predictably in a multilayer PCB. Use the receiver's timing specification to define the allowable clock-to-data skew, and keep video and power-distribution regions separated. Cable-based implementations also require connector, cable, and receiver termination validation.
추천
Test and Measurement Equipment
The DS90CR215MTD is useful in test and measurement instruments that move acquisition results, calibration tables, or instrument-control data between high-speed modules. Differential signaling at up to 66 MHz reduces sensitivity to ground offsets and radiated noise commonly found near switching power supplies. Position the transmitter near the receiver and receiver termination to minimize signal loss and maintain timing margin. For laboratory-grade accuracy, separately evaluate analog reference noise, clock jitter, and data-converter aperture requirements because the LVDS link itself does not improve source accuracy.
추천
엔지니어링 참조 데이터: DS90CR215MTD — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | DS90CR215MTD/NOPB |
|---|---|---|
| Package | 48-TSSOP | 48-TSSOP - same package |
| Brand | Texas Instruments | Texas Instruments |
| Product Function | Rising-edge data-strobe LVDS transmitter | Rising-edge data-strobe LVDS transmitter |
| Supply Voltage | 3.3 V | 3.3 V |
| Data Width | 21 bits | 21 bits |
| Maximum Clock Frequency | 66 MHz | 66 MHz |
| Output Signaling | LVDS differential | LVDS differential |
| Data-Strobe Edge | Rising edge | Rising edge |
주요 차별점
- Exact verified ordering alternative (vs DS90CR215MTD/NOPB)
- Dedicated parallel-to-LVDS transmitter function (vs DS90CR216 family)
- Wide parallel payload in a compact interface package (vs Narrower Channel Link interface options)
설계 노트
Route every LVDS data and strobe pair as a coupled differential pair over a continuous reference plane. Keep the pair spacing and trace width consistent with the required characteristic impedance, avoid plane splits beneath the links, and remove unnecessary stubs. Place the transmitter close to the receiving device or connector so that only the required signal travels through the higher-noise region of the PCB.
Use the DS90CR215/DS90CR216 datasheet timing diagrams to establish clock-to-data skew and setup-and-hold margins across the complete link. Account for connector and cable delay as well as PCB propagation delay. When the link crosses a cable assembly, verify the receiver termination, cable impedance, and loss rather than assuming that the transmitter's differential outputs alone guarantee reliable operation.
Place bypass capacitors close to the device's supply and ground connections and follow the pin-specific arrangement shown in the manufacturer datasheet. Provide a return path that does not force high-frequency differential return current through a split or narrowed plane. If the link transmitter shares a board with switching regulators or relays, separate their current paths and verify the supply ripple at the device pins with an oscilloscope.
Do not substitute the companion DS90CR216 receiver for the DS90CR215 transmitter, and do not assume a shared package guarantees interchangeable function. Confirm that every candidate has the same transmitter role, data width, clock-rate rating, supply requirements, pin mapping, and output interface. Also verify the exact MTD ordering suffix because NOPB identifies a lead-finish option rather than a new protocol configuration.
규정 준수 정보
The retrieved listings identify a separate MTD/NOPB ordering option but do not explicitly state this part's RoHS, REACH, halogen-free, or conflict-minerals status. AEC-Q100 qualification is not applicable to this general-purpose interface IC because no automotive qualification was identified.