INA129SHKJ - 8-Pin Precision Instrumentation Amplifier | TI
부품 번호: INA129SHKJ ✓ 활성INA129SHKJ 개요
An instrumentation amplifier is a specialized differential amplifier designed to amplify the difference between two input signals while rejecting common-mode voltage, supply variation, and other disturbances that appear equally at both inputs. Its typical hierarchy is instrumentation amplifier → differential amplifier → analog signal-conditioning IC → semiconductor. Unlike a general-purpose operational amplifier, an instrumentation amplifier commonly integrates input buffers, a differential gain stage, and feedback resistors in a high-precision package.
The INA129SHKJ provides several characteristics suited to demanding measurement systems. Its gain is established with one external resistor, and its gain equation is compatible with the AD620, allowing familiar gain-selection calculations. The device is laser trimmed for low offset voltage, with a typical value of 25 µV, and its input bias current is listed as 50 nA typical. Typical common-mode rejection is 95 dB, while the manufacturer identifies 93 dB CMRR at gains of 100 or greater. Input protection extends to ±40 V for applications in which transient or fault voltages may appear at the measurement terminals.
Electrically, the INA129 combines internal gain-setting elements with a single external resistor, making gain selection straightforward across a wide range. The 1.3 MHz gain-bandwidth figure supports operation across sensor instrumentation, bridge measurement, and industrial monitoring applications, although the usable bandwidth depends on the selected gain. The 4 V/µs slew rate provides adequate large-signal response for many low- and medium-frequency sensing systems. Low quiescent current and low input bias current also help reduce loading of high-impedance transducers.
Typical uses include current shunt measurement, strain-gauge and resistance bridge excitation, precision sensor interfaces, industrial process monitoring, and high-voltage measurement systems where protected inputs are advantageous. The ceramic package and broad specified temperature range make the INA129SHKJ particularly relevant to harsh-environment instrumentation, including industrial, aerospace, and defense systems where long-term thermal stability and input robustness are essential.
Designers should account for input and output common-mode limits, external resistor tolerance and temperature coefficient, input filtering, supply bypass capacitance, and PCB thermal performance. A single resistor sets the gain, but its tolerance directly affects gain accuracy. The protected inputs should still be analyzed for continuous overvoltage, because protection is not a substitute for correctly rating external circuitry. Reference-ground connections and exposed pad or ceramic-package thermal paths should follow the manufacturer's pin and layout guidance.
This page combines package, electrical, pricing, sourcing, and lifecycle information with application guidance and engineering checks for the INA129SHKJ. It also highlights the distinction between exact package equivalence and merely similar instrumentation amplifiers, helping buyers evaluate replacement risk before committing to a board-level substitution.
드롭인 대체품: INA129SHKJ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 제품에는 사용 가능한 드롭인 대체품이 없습니다.
대체품 요청INA129SHKJ 최대 정격 & 전기적 특성
| Amplifier Type | Precision instrumentation amplifier |
| Number of Circuits | 1 circuit |
| 패키지 | 8-CFP ceramic flat package |
| Packaging | Tube |
| Gain Range | 1 to 10,000 |
| Gain Setting | 1 external resistor |
| Gain-Bandwidth Product | 1.3 MHz |
| Slew Rate | 4 V/µs |
| 공급 전류 | 700 µA |
| 대기 전류 | 2 mA typical |
| Input Bias Current | 50 nA typical |
| Offset Voltage | 25 µV typical |
| Common-Mode Rejection | 95 dB typical |
| CMRR at Gain of 100 or Greater | 93 dB minimum |
| Input Protection Range | ±40 V |
| Wide Supply Range | ±18 V |
| 동작 온도 범위 | -55 °C to +210 °C |
| 실장 유형 | Surface mount |
INA129SHKJ 8-cfp ceramic flat package 핀 구성 가이드
INA129SHKJ(8-cfp ceramic flat package 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: INA129SHKJ.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
INA129SHKJ 적합 용도: 6 애플리케이션s: High-Side Current Sensing, Strain-Gauge Bridge Instrumentation, Precision Pressure Sensor Interface, Industrial Process Measurement, Aerospace Sensor Signal Conditioning, Low-Level Differential Data Acquisition.
High-Side Current Sensing
The INA129SHKJ is well suited to measuring the small differential voltage produced by a current shunt while rejecting the common-mode voltage present in the supply path. Its 95 dB typical common-mode rejection, 25 µV typical offset voltage, and 50 nA typical input bias current help preserve measurement accuracy when the shunt voltage is small. The device can be placed across a shunt in a ±18 V power system, with its protected inputs extending to ±40 V. A single external resistor sets the gain from 1 to 10,000, allowing the shunt millivolt signal to be scaled for an ADC. Engineering attention should remain on common-mode limits, shunt placement, Kelvin routing, and gain-bandwidth interaction rather than treating the instrumentation amplifier as a universal front end.
추천
Strain-Gauge Bridge Instrumentation
The INA129SHKJ can amplify the millivolt-level differential output of a resistive strain-gauge or load-cell bridge while rejecting excitation-related common-mode voltage. Low offset voltage of 25 µV typical and input bias current of 50 nA typical are especially useful in bridge circuits where small signals sit near the lower end of the converter range. Its externally selected gain from 1 to 10,000 permits scaling for a 2.5 V, 3.3 V, or 5 V measurement chain. Designers should calculate the full bridge output, worst-case resistor tolerance, excitation drift, and self-heating effects. The 1.3 MHz bandwidth also means that high gain reduces usable signal bandwidth, so filtering and acquisition timing should be planned together.
추천
Precision Pressure Sensor Interface
The INA129SHKJ provides a direct interface for differential pressure sensors whose outputs contain a small amplified signal riding on a larger common-mode voltage. Its high common-mode rejection reduces errors from sensor excitation and analog ground shifts, while the 50 nA typical input bias current limits loading of high-impedance sensor outputs. The ±18 V wide-supply capability supports industrial signal-conditioning systems, and protected inputs to ±40 V improve tolerance of installation transients. Gain is selected with one resistor using the AD620-compatible equation. For reliable pressure measurements, the engineer should also evaluate sensor sensitivity, excitation drift, analog input filtering, common-mode range, and the amplifier's noise contribution relative to the smallest pressure being resolved.
추천
Industrial Process Measurement
The INA129SHKJ can condition low-level differential process signals when field wiring introduces substantial voltage variation between the two measurement terminals. Its 95 dB typical common-mode rejection helps suppress coupled industrial noise, while the 4 V/µs slew rate provides useful response for many process-control bandwidths. The 8-CFP ceramic package is suitable for demanding industrial and harsh-environment equipment where a plastic package may be insufficient. Designers should place the amplifier close to the sensor or connector, use guarding and differential routing for high-impedance sources, and provide local supply bypassing. The external gain resistor needs an appropriate tolerance and temperature coefficient, while the selected gain must leave enough bandwidth for the process-control loop.
추천
Aerospace Sensor Signal Conditioning
The INA129SHKJ's -55 °C to +210 °C operating range and ceramic package make it applicable to aerospace and other high-temperature sensing systems. The instrumentation amplifier can measure differential sensor outputs while its common-mode rejection limits errors from system grounding and supply changes. The 25 µV typical offset is valuable when the sensor output is small, and the AD620-compatible gain equation supports familiar resistor selection. Qualification for an individual aerospace program still requires examination of the exact ordering code, package qualification, screened-part options, and system requirements. Circuit designers should verify input common-mode limits across temperature, avoid placing unnecessary stress on the protected inputs, and account for ceramic-package thermal expansion and solder-joint reliability during assembly.
추천
Low-Level Differential Data Acquisition
The INA129SHKJ is useful as the analog front end for low-level differential sensors feeding a high-resolution converter. Its 1.3 MHz gain-bandwidth figure, 4 V/µs slew rate, low offset voltage, and high common-mode rejection provide a combination of signal fidelity and operating flexibility. The instrumentation amplifier can amplify a bipolar sensor output toward the converter's input range while rejecting common-mode voltage from cables or shared supplies. For optimum results, the engineer must select a gain that preserves required bandwidth, account for gain-resistor error, and calculate noise and settling time at the ADC. A differential or carefully filtered converter interface, local ground planning, and short high-impedance traces are as important as the nominal gain-bandwidth value.
추천
추천 제품 요약
엔지니어링 참조 데이터: INA129SHKJ — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 |
|---|---|
| Package | 8-CFP ceramic flat package |
| Brand | Texas Instruments |
| Number of Circuits | 1 circuit |
| Gain Range | 1 to 10,000 |
| Gain-Bandwidth Figure | 1.3 MHz |
| Slew Rate | 4 V/µs |
| Input Bias Current | 50 nA typical |
| Offset Voltage | 25 µV typical |
| Common-Mode Rejection | 95 dB typical |
| Input Protection | ±40 V |
| Wide Supply Range | ±18 V |
| Operating Temperature | -55 °C to +210 °C |
주요 차별점
- High-temperature ceramic package option (vs A standard plastic SOIC instrumentation amplifier)
- Wide protected-input capability (vs A lower-rated precision instrumentation amplifier)
- AD620-compatible gain calculation (vs INA128SHKJ)
- Precision offset for millivolt-level signals (vs A general-purpose precision op-amp circuit)
설계 노트
Route the two input signals as a close-coupled differential pair and keep the external gain resistor close to the gain-setting pin. Use a ground plane, minimize input-loop area, and avoid routing sensitive inputs beside switching nodes or high-current return paths. The ceramic package requires attention to thermal expansion and solder-joint reliability, so follow the manufacturer's land pattern and reflow recommendations.
Place the supply bypass capacitors immediately across the supply and ground pins, with the shortest possible return path. Use the capacitor values and stability guidance specified in the manufacturer datasheet for the operating gain and supply configuration. Verify positive and negative supply sequencing if the surrounding system can power the rails independently, and confirm that all input and output voltages remain within their rated common-mode limits.
Do not treat the ±40 V input-protection rating as permission for continuous operation outside the normal common-mode range. Continuous voltage, fault duration, input current, and temperature can still limit safe operation. Also avoid copying an INA128 gain resistor into an INA129 design because the gain equations differ; calculate the INA129 value with the manufacturer equation and include resistor tolerance and temperature-coefficient errors.
Account for the gain-dependent reduction in usable bandwidth before selecting the highest available gain. The nominal 1.3 MHz gain-bandwidth figure does not mean every gain setting supports full bandwidth, and the 4 V/µs slew rate can become a limitation for large output steps. For sensor interfaces, filter close to the source where possible and include anti-alias filtering ahead of the ADC.
The INA129SHKJ is specified over an unusually broad -55 °C to +210 °C temperature range, but electrical limits and package stress must be checked at the actual hottest location. Estimate dissipation from the selected supply voltages, output voltage, and load current, then ensure that board construction and airflow maintain acceptable junction temperature. Use the manufacturer's thermal model rather than relying on ambient temperature alone.
규정 준수 정보
RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation from the manufacturer product documentation. AEC-Q100 is not applicable because this is an instrumentation amplifier rather than an automotive-qualified device.