INA2141UG4 - Dual 10/100 Gain Instrumentation Amp | TI
부품 번호: INA2141UG4 ✓ 활성INA2141UG4 개요
An instrumentation amplifier is a precision analog circuit that amplifies the voltage difference between two inputs while rejecting common-mode signals. The INA2141 belongs to the instrumentation-amplifier hierarchy within amplifier ICs and analog signal-chain conditioning. Its internal three-op-amp architecture supports current-feedback input circuitry, preserving useful bandwidth at high gain and simplifying front-end design for bridge sensors, low-voltage sensing, and industrial measurement systems.
Key characteristics include two amplifiers per package, gain options of 10 and 100, 200 kHz bandwidth at a gain of 100, and a typical signal-to-noise ratio listed at 117 dB. The operating temperature range extends from -40 °C to +85 °C. The gain-setting arrangement eliminates the need for external feedback resistors, while the integrated input circuitry reduces component count and makes the device suitable for compact, high-impedance sensing nodes.
Technically, the INA2141 combines differential input handling with internal feedback networks and an output amplifier in each channel. Current-feedback input circuitry is the key bandwidth feature: the specified 200 kHz gain-bandwidth behavior at gain 100 supports faster signal capture than a typical low-frequency precision-only instrumentation amplifier. The device operates from a 5 V supply and consumes approximately 15 mA, balancing channel density, measurement bandwidth, and power consumption for portable and industrial equipment.
Typical uses include precision bridge excitation for pressure and load cells, current-sense amplification in power systems, battery and energy monitoring, biomedical instrumentation interfaces, and factory sensor acquisition. In bridge-based measurements, the amplifier rejects supply and ground disturbances shared by both sensor inputs. In current sensing, it magnifies a small differential shunt voltage while limiting the influence of common supply variation.
A critical design consideration is input and output range: the selected gain and 5 V supply determine the usable differential and output spans. Review the absolute maximum and recommended operating conditions in the manufacturer datasheet before applying large bridge or shunt inputs. PCB placement should keep sensitive input traces short, provide a stable reference or return path, and separate analog routing from switching-converter and digital timing nodes.
This page combines manufacturer electrical characteristics, package and ordering information, sourced pricing, drop-in replacement guidance, and application-focused engineering guidance. It is intended to help engineers evaluate the INA2141UG4 for precision differential measurement while identifying the key electrical and layout checks required before release to production.
드롭인 대체품: INA2141UG4 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: INA2141UG4 (동일 폼 팩터 및 풋프린트) — 차이점: Input Bias Current, Input Offset Voltage Drift, Package, Slew Rate.
INA2141U
✅ 드롭인가격 문의
데이터시트 보기 →INA2141UE4
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
INA2141UG4 최대 정격 & 전기적 특성
| Product Type | Dual instrumentation amplifier |
| Number of Channels | 2 channels |
| Amplifier Architecture | 3-op-amp instrumentation amplifier per channel |
| Gain Options | 10 or 100 V/V |
| Bandwidth at Gain 100 | 200 kHz |
| Signal-to-Noise Ratio | 117 dB |
| 공급 전류 | 15 mA |
| Slew Rate | 1 V/us |
| Input Offset Voltage Drift | 500 nV/°C |
| Maximum Output Error | 50 uV |
| Input Bias Current | 5 nA |
| Output Current | 750 uA |
| 공급 전압 | 5 V |
| 동작 온도 범위 | -40 °C to +85 °C |
| 패키지 | 16-pin SOIC, 300 mil |
| 실장 유형 | Surface mount |
| RoHS 상태 | Compliant |
| Gain Resistors | Integrated; external feedback resistors not required |
| Input Circuitry | Current-feedback |
INA2141UG4 16-pin soic, 300 mil 핀 구성 가이드
INA2141UG4(16-pin soic, 300 mil 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: INA2141UG4.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
INA2141UG4 적합 용도: 6 애플리케이션s: Pressure and Load-Cell Bridge Sensing, Battery and Power-Current Monitoring, Industrial Sensor Signal Conditioning, Medical and Biosignal Instrumentation, Portable Instrument and Test Equipment, Precision Feedback and Control Loops.
Pressure and Load-Cell Bridge Sensing
The INA2141UG4 fits dual-channel bridge sensing because each channel amplifies the small differential voltage generated by a resistive load cell while rejecting voltage common to both inputs. Its internal gains of 10 or 100 avoid external feedback resistors, and the 200 kHz bandwidth at gain 100 supports faster force or pressure changes. Two channels can monitor independent axes in a multi-axis sensor. The main design limit is the allowable input common-mode range and output swing, which must remain within the 5 V supply and the datasheet limits.
추천
Battery and Power-Current Monitoring
The INA2141UG4 can amplify the differential voltage across a low-ohm shunt in a battery-management or power-conversion system. Gain 10 is useful for larger shunt signals, while gain 100 increases sensitivity to smaller voltage drops. Its common-mode rejection helps prevent supply ripple and ground offsets from appearing at the output. Two independent channels can monitor input and output current simultaneously. Designers should verify the shunt common-mode voltage, output swing, and amplifier stability for the selected gain.
추천
Industrial Sensor Signal Conditioning
The INA2141UG4 is suitable for conditioning low-level industrial sensor outputs before digitization or control. The dual architecture reduces the component count when two transducers must be measured, and the integrated 10 and 100 gain choices simplify front-end configuration. Current-feedback input circuitry provides 200 kHz bandwidth at gain 100 for moderate-speed process signals. Layout should keep input traces short and isolated from switching nodes, while the reference input must be driven appropriately when a nonzero output offset is required.
추천
Medical and Biosignal Instrumentation
The INA2141UG4 can serve as the first analog stage in medical or biosignal instrumentation when the sensor output is differential and the system requires two measurement channels. Instrumentation-amplifier topology suppresses common-mode interference, while the 10 and 100 gain settings support different transducer sensitivities. The 16-pin SOIC format allows compact board placement, and 200 kHz bandwidth at gain 100 accommodates more demanding physiological signals. Safety, input protection, patient isolation, and application-specific standards require separate system-level validation.
추천
Portable Instrument and Test Equipment
The INA2141UG4 is appropriate for portable measurement equipment where two precision channels must fit in a compact area without a large external resistor network. Operation from a 5 V rail and approximately 15 mA supply current supports power-constrained instruments, while the internal gain options simplify calibration. The 200 kHz bandwidth at gain 100 allows measurement of moderately fast events rather than only static voltages. Care should be taken to avoid input overload and to preserve common-mode headroom during battery changes.
추천
Precision Feedback and Control Loops
The INA2141UG4 can condition differential feedback signals in precision analog control systems, particularly when the controller benefits from rejection of shared supply or ground disturbances. Gain 100 increases small error-signal sensitivity while retaining 200 kHz bandwidth, making it useful in current-feedback control architectures. The two channels can form matched signal paths for differential sensing. Stable operation depends on keeping the common-mode and differential inputs inside the specified range, providing a clean reference connection, and avoiding excessive output loading.
추천
추천 제품 요약
엔지니어링 참조 데이터: INA2141UG4 — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | INA2141U | INA2141UE4 |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Number of Channels | 2 | 2 | 2 |
| Gain Settings | 10 or 100 V/V | 10 or 100 V/V | 10 or 100 V/V |
| Bandwidth at Gain 100 | 200 kHz | 200 kHz | 200 kHz |
| Supply Voltage | 5 V | 5 V | 5 V |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C |
| Input Architecture | Current-feedback | Current-feedback | Current-feedback |
주요 차별점
- Two instrumentation-amplifier channels in one package (vs INA2141U)
- Wide bandwidth retained at the higher internal gain (vs INA2141UE4)
- Compact 16-pin SOIC implementation (vs INA2141U)
설계 노트
Route both inputs of each differential channel as closely matched, short traces as practical. Keep input nodes away from switching-regulator outputs, relay contacts, motor traces, and high-current return paths. The reference input should have a low-impedance local return path, and unused channel inputs should be connected according to the manufacturer recommendations rather than left floating.
Estimated supply-current draw is approximately 15 mA at the specified 5 V operating condition. Estimated power dissipation using an input of 5 V, output of 3.3 V, and 15 mA current is (5 V - 3.3 V) × 0.015 A = 0.0255 W. Confirm actual channel loading, supply tolerance, and regulator headroom in the finished design rather than using this estimate as a worst-case thermal rating.
Do not select the gain solely from signal amplitude. First confirm that the input common-mode voltage remains inside the operating range, then verify that the multiplied differential signal and reference offset can swing within the output limits. Overload, common-mode clipping, and output saturation produce different symptoms and require different corrections.
For gain 100, preserve the 200 kHz bandwidth capability by minimizing parasitic capacitance on the input and output nodes and placing any required output filtering close to the amplifier. Input shielding or guarding may be necessary for very high source impedances, while solid reference grounding helps suppress common-mode and ground-induced errors.
규정 준수 정보
The component listing identifies the INA2141UG4 as RoHS compliant. No specific REACH, halogen-free, conflict-minerals, or automotive qualification statement is published in the cited product information.