INA331IDGKR - 25 V/V Rail-to-Rail Instrumentation Amp | TI
부품 번호: INA331IDGKR ✓ 활성INA331IDGKR 개요
An instrumentation amplifier is a differential-input analog signal-conditioning IC that amplifies the voltage difference between two sensors while rejecting common-mode interference. The INA331 belongs to the hierarchy of instrumentation amplifier, differential amplifier, analog amplifier, and amplifier IC. It is used where a small sensor differential must be measured accurately in the presence of larger common-mode voltages, particularly in battery-powered industrial, medical, and portable systems.
Key features include gain accuracy of 0.02% and a gain temperature coefficient of 2 ppm/°C for gains above 5 V/V. The device has an input offset voltage of ±250 µV, low input bias current, 90 dB CMRR, and a 2.0 MHz bandwidth. Its 5 V/us slew rate supports faster signal transitions, while single-supply and rail-to-rail operation simplify systems operating from a low-voltage source. The low-power design is suited to portable instrumentation and sensor interfaces.
The INA331 uses external gain-setting resistors, allowing the closed-loop gain to be adjusted for the required measurement range without changing the package. At the specified 25 V/V gain, the device combines useful bandwidth for low-frequency sensor measurements with common-mode rejection for noisy industrial environments. The input and output stages operate from a single supply, reducing the number of rails required in portable equipment.
Typical applications include low-side current sensing in battery systems, differential pressure and temperature measurement, biomedical instrumentation, portable sensor acquisition, industrial bridge excitation, and precision current measurement. The INA331 is especially appropriate when the sensor output is small, the required gain is above 5 V/V, and system power consumption must remain low.
When implementing the circuit, place the gain-setting resistors close to the gain inputs and keep the input differential loop area small to minimize noise pickup. Check the common-mode input range at the selected supply voltage and gain because the amplifier must remain within its valid operating region. Decoupling capacitors should be positioned close to the supply pins, with the layout verified against the manufacturer reference layout.
This page combines the exact orderable part information, package characteristics, gain and common-mode performance, application guidance, replacement analysis, and PCB considerations needed to evaluate INA331IDGKR before implementation.
드롭인 대체품: INA331IDGKR — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
INA331AIDGKR
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
INA331IDGKR 최대 정격 & 전기적 특성
| Device Type | Single-supply CMOS instrumentation amplifier |
| Number of Amplifiers | 1 circuit |
| Closed-Loop Gain | 25 V/V |
| Gain Accuracy | 0.02% |
| Gain Temperature Coefficient | 2 ppm/°C |
| Minimum External-Resistor Gain | >5 V/V |
| Input Offset Voltage | ±250 µV |
| CMRR | 90 dB |
| CMRR at 45 kHz | 94 dB |
| Bandwidth | 2.0 MHz |
| Slew Rate | 5 V/µs |
| Input Bias Current | 1.00E-5 µA |
| 공급 전압 | 5 V |
| 동작 온도 범위 | -55 °C to +125 °C |
| 패키지 | 8-pin VSSOP (DGK) |
| 실장 유형 | Surface mount |
| 출력 유형 | Rail-to-rail |
| Supply Type | Single supply |
INA331IDGKR 8-pin vssop (dgk) 핀 구성 가이드
INA331IDGKR(8-pin vssop (dgk) 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: INA331IDGKR.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
INA331IDGKR 적합 용도: 6 애플리케이션s: Battery-Powered Low-Side Current Sensing, Industrial Bridge-Sensor Interface, Portable Medical-Sensor Signal Conditioning, Portable Temperature and Pressure Sensing, Precision Current Monitoring, Low-Level Differential Voltage Acquisition.
Battery-Powered Low-Side Current Sensing
INA331IDGKR is appropriate for amplifying the small differential voltage produced by a low-side shunt while the power rail carries a much larger common-mode voltage. Its characterized 25 V/V closed-loop gain increases the shunt signal for an ADC, while 90 dB CMRR reduces errors caused by supply ripple and current-path variations. The 5 V/µs slew rate supports signals with moderate frequency content, and the 2.0 MHz bandwidth is appropriate for many power-control and battery-management channels. Keep the shunt and amplifier ground paths compact, verify the common-mode range at the selected gain, and place the supply bypass capacitor close to the device.
추천
Industrial Bridge-Sensor Interface
INA331IDGKR can condition the small differential output of a resistive bridge sensor in an industrial measurement system. A 25 V/V gain accommodates millivolt-level bridge signals without requiring multiple amplifier stages, and the specified 0.02% gain accuracy supports repeatable conversion results. Its 90 dB CMRR helps preserve measurement integrity when the bridge shares ground paths with motors, relays, or switching converters. The single-supply, rail-to-rail architecture also suits compact sensor modules. Designers should use low-noise gain resistors, maintain a small differential input loop, and confirm that excitation and output levels remain within the datasheet limits.
추천
Portable Medical-Sensor Signal Conditioning
INA331IDGKR is suitable for low-level biomedical sensor conditioning when the selected gain, accuracy, and supply conditions satisfy the medical application's requirements. The 25 V/V gain can increase a weak differential sensor output before digitization, while ±250 µV offset and 0.02% gain accuracy support precision measurement. Low input bias current is valuable with high-impedance sensors, and the low-power single-supply design fits portable equipment. The -55 °C to +125 °C operating rating covers industrial temperature ranges, but it does not itself establish medical certification. Final designs must separately verify isolation, leakage current, electrode protection, noise performance, and applicable regulatory requirements.
추천
Portable Temperature and Pressure Sensing
INA331IDGKR provides a compact analog front end for resistive temperature detectors, strain-based pressure sensors, and other differential transducers. Its 25 V/V gain reduces the dynamic range burden placed on the following ADC, while 90 dB CMRR improves rejection of common-mode noise found in longer cable runs. The 2.0 MHz bandwidth is more than adequate for many thermal and pressure measurements whose useful bandwidth is much lower. For portable systems, the single-supply architecture simplifies power management, and rail-to-rail output operation improves usable range. Place gain resistors close to the amplifier, protect inputs from ESD, and verify sensor excitation requirements and shutdown behavior during inactive periods.
추천
Precision Current Monitoring
INA331IDGKR is well matched to precision current monitoring in power converters, battery packs, and portable test equipment. A shunt produces a differential voltage proportional to current, and the amplifier's 25 V/V gain raises that signal for measurement by an ADC or comparator. The 90 dB CMRR helps reject the fast common-mode transitions present in switching power paths, while 5 V/µs slew rate preserves response during current changes. The single-supply design is compatible with low-voltage systems. Use Kelvin routing where practical, keep the gain resistors close to the device, and verify both input and output headroom across the intended current range and supply tolerance.
추천
Low-Level Differential Voltage Acquisition
INA331IDGKR is useful when a system must measure a small differential voltage riding on a larger common-mode potential. Its characterized gain of 25 V/V, offset voltage of ±250 µV, and CMRR of 90 dB reduce the number of precision analog stages required. The 2.0 MHz bandwidth accommodates signal bandwidth beyond that of basic temperature sensors while avoiding unnecessary high-speed power requirements. The device can therefore serve in laboratory instrumentation, portable analyzers, and embedded sensor nodes. Confirm the valid common-mode range for the chosen gain and supply, review the resistor-based gain equation, and ensure the source impedance and input bias current meet the datasheet recommendations.
추천
추천 제품 요약
엔지니어링 참조 데이터: INA331IDGKR — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | INA331AIDGKR |
|---|---|---|
| Manufacturer | Texas Instruments | Texas Instruments |
| Package | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) |
| Device Family | INA331 | INA331 |
| Amplifier Type | Single-supply CMOS instrumentation amplifier | Single-supply CMOS instrumentation amplifier |
주요 차별점
- Integrated precision gain for weak differential sensors (vs INA331AIDGKR)
- Common-mode rejection for noisy measurement paths (vs INA331AIDGKR)
- Low-power single-supply operation (vs INA331AIDGKR)
설계 노트
Place the external gain-setting resistors close to the INA331 gain-input pins and keep the differential input traces short and tightly coupled. High-impedance input nodes can pick up leakage and capacitive noise when routed near switching nodes. Connect the supply bypass capacitor directly between the supply and ground pins, and follow the manufacturer layout and grounding recommendations to preserve the specified offset and common-mode rejection behavior.
Before fixing the gain and supply voltage, verify the complete signal path against the input common-mode range, output swing, and gain-dependent limitations in the Texas Instruments INA331 datasheet. A low-side shunt measurement can have a large common-mode voltage even when its differential signal is small. The amplifier's single-supply architecture does not remove the need to check headroom at both input and output under worst-case load and supply conditions.
Do not substitute INA331AIDGKR solely because it uses the same DGK package. Although it is a documented same-family drop-in candidate, confirm the exact suffix's gain configuration, revision-specific electrical limits, temperature coverage, and ordering information in the manufacturer documentation. Also verify that the selected resistor values produce the intended gain and that the gain network's noise and temperature drift meet the measurement requirement.
규정 준수 정보
The exact orderable-part information identifies INA331IDGKR as a Texas Instruments INA331 device in an 8-pin VSSOP (DGK) package. Specific environmental and material-compliance declarations were not stated in the orderable-part information and must be confirmed on the manufacturer product page before procurement.