ISL26132AVZ - 24-Bit Low-Noise Delta-Sigma ADC | Renesas
부품 번호: ISL26132AVZ ✓ 활성ISL26132AVZ 개요
A delta-sigma ADC is a type of analog-to-digital converter that uses oversampling, noise shaping, and digital filtering to achieve high resolution. In the broader semiconductor hierarchy, the ISL26132AVZ is an ADC, then a data converter, then a signal-chain IC and semiconductor. Its integrated low-noise amplifier reduces the need for separate analog front-end amplification while retaining differential-input measurement capability.
The ISL26132 provides pin compatibility and output-data compatibility with the Texas Instruments ADS1232. This relationship enables a practical replacement strategy when the alternative device uses the same 24-TSSOP footprint, matching pinout, and conversion interface. The manufacturer identifies the ISL26132 and ISL26134 family as complete analog front ends for high-resolution measurement applications, with the ISL26132 providing two differential multiplexer inputs and the related ISL26134 providing four.
Conversion features are controlled through pins, while offset calibration, standby operation, and conversion data are accessed through a simple two-wire interface. The 24-bit resolution is particularly useful when the measured quantity occupies only part of the full-scale input range. For example, a weighing cell or temperature sensor can benefit from the converter's fine digital resolution without requiring a high-speed converter.
Typical applications include industrial process-control instrumentation, precision bridge and load-cell measurement, laboratory data acquisition, medical monitoring equipment, and low-frequency sensor acquisition. The selectable 10 SPS and 80 SPS rates let a designer balance measurement latency against noise performance: 10 SPS is appropriate when settling time is less critical, while 80 SPS supports faster updates.
Layout and signal-integrighty practices are essential because the device is intended for low-noise measurement. Place the analog input and reference connections away from switching nodes, use a quiet ground return for the measurement circuit, and decouple the supply close to the device. Differential input routing should be symmetric and compact to minimize conversion of common-mode noise into differential error.
This product page combines the manufacturer function description, package information, pin- and output-compatible replacement guidance, practical application guidance, and engineering design notes. The comparison section helps distinguish the standard device from its same-family orderable variants and the ADS1232-compatible alternative, while the design notes focus on noise, grounding, filtering, and signal integrity.
드롭인 대체품: ISL26132AVZ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: ISL26132AVZ (동일 폼 팩터 및 풋프린트) — 차이점: Resolution, Input Configuration, Package.
ISL26132AVZ-T7A
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ISL26132AVZ-T
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ADS1232IPW
✅ 드롭인가격 문의
데이터시트 보기 →ISL26132AVZ 최대 정격 & 전기적 특성
| ADC Type | 24-bit delta-sigma ADC |
| Input Configuration | 2 differential multiplexer inputs |
| 분해능 | 24 bit |
| Conversion Rate | 10 SPS or 80 SPS |
| Integrated Amplifier | 1 very low-noise amplifier |
| 인터페이스 | 2-wire serial interface |
| 패키지 | 24-pin TSSOP |
| Pin Compatibility | Compatible with ADS1232 pinout |
| Output Data Compatibility | Compatible with ADS1232 output data |
| Offset Calibration | Accessible through the 2-wire interface |
| Standby Control | Accessible through the 2-wire interface |
ISL26132AVZ 24-pin tssop 핀 구성 가이드
ISL26132AVZ(24-pin tssop 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: ISL26132AVZ.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
ISL26132AVZ 적합 용도: 6 애플리케이션s: Precision Load-Cell Measurement, Industrial Process Instrumentation, Medical Monitoring Equipment, Laboratory Data Acquisition, Precision Temperature Sensing, Low-Noise Sensor Acquisition.
Precision Load-Cell Measurement
The ISL26132AVZ fits load-cell and strain-gauge front ends that require fine digital resolution rather than high conversion speed. Its two differential inputs can measure bridge signals while rejecting common-mode voltage, and the integrated low-noise amplifier reduces the number of sensitive analog stages in the signal chain. Selectable 10 SPS and 80 SPS operation allows the design to prioritize noise integration or measurement responsiveness. Bridge excitation, input filtering, reference stability, and mechanical settling time still determine final measurement accuracy.
추천
Industrial Process Instrumentation
The ISL26132AVZ is appropriate for slow industrial process signals such as pressure, temperature, and position transducers. Its 24-bit resolution preserves detail when the sensor output occupies only a small portion of the available analog range, while the 10 SPS mode supports periodic process monitoring and the 80 SPS mode can reduce update latency. A solid design also requires protected analog routing, stable references, local supply bypassing, and isolation where the transducer is electrically connected to high-energy equipment.
추천
Medical Monitoring Equipment
The ISL26132AVZ can serve low-frequency medical monitoring front ends that measure weak differential sensor signals, provided the electrical characteristics match the selected sensor and isolation architecture. The 24-bit resolution and integrated low-noise amplifier are useful for extracting small physiological or biochemical signals, while differential inputs help reject common-mode interference. Designers should define the required accuracy, drift, noise, safety isolation, and acquisition timing, then confirm those limits against the manufacturer electrical tables before clinical use.
추천
Laboratory Data Acquisition
The ISL26132AVZ is well suited to laboratory instruments that acquire low-level analog quantities at modest data rates and require high-resolution readings. Two differential channels allow the front end to measure a sensor while rejecting common-mode offsets, and the 24-bit converter avoids some of the signal-conditioning complexity associated with lower-resolution mixed-signal systems. The instrument should implement careful grounding, shielded interconnects when needed, reference conditioning, and digital averaging or filtering only where update timing remains acceptable.
추천
Precision Temperature Sensing
The ISL26132AVZ can digitize resistive temperature sensors such as RTDs and thermistors when low-rate, high-resolution acquisition is the priority. Differential input handling supports bridge or four-wire-style sensor arrangements, while 10 SPS and 80 SPS provide selectable update rates. Accuracy is not determined by converter resolution alone: sensor self-heating, excitation current, lead resistance, reference drift, input settling, and the selected conversion rate must be included in the error budget.
추천
Low-Noise Sensor Acquisition
The ISL26132AVZ is useful for generic low-level sensor acquisition where signal amplitude is small and measurement noise is more important than throughput. The integrated very low-noise amplifier, 24-bit delta-sigma conversion, and two differential inputs create a compact analog front end for resistive, capacitive, or external sensor-conditioning circuits. Keep sensor excitation separate from sensitive converter traces, maintain a clean analog ground path, and select the slower conversion rate when minimum noise is more valuable than rapid updates.
추천
추천 제품 요약
엔지니어링 참조 데이터: ISL26132AVZ — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | ISL26132AVZ-T7A | ISL26132AVZ-T | ADS1232 |
|---|---|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics | Texas Instruments |
| Package | 24-TSSOP | 24-TSSOP | 24-TSSOP | 24-TSSOP |
| ADC Architecture | 24-bit delta-sigma | 24-bit delta-sigma | 24-bit delta-sigma | 24-bit delta-sigma |
| Input Configuration | 2 differential inputs | 2 differential inputs | 2 differential inputs | 2 differential inputs |
| Conversion Rates | 10 SPS and 80 SPS | 10 SPS and 80 SPS | 10 SPS and 80 SPS | 10 SPS and 80 SPS |
| Integrated Amplifier | Very low-noise amplifier | Very low-noise amplifier | Very low-noise amplifier | Integrated low-noise PGA |
| Digital Interface | 2-wire serial interface | 2-wire serial interface | 2-wire serial interface | 2-wire serial interface |
| Pin Compatibility | ADS1232 pin-compatible | Same ISL26132 pinout | Same ISL26132 pinout | Reference ADS1232 device |
| Output Data Compatibility | ADS1232 output-data-compatible | Same ISL26132 data format | Same ISL26132 data format | Reference ADS1232 data format |
주요 차별점
- Direct Renesas orderable alternative with identical conversion configuration (vs ISL26132AVZ-T7A)
- Pin- and output-data-compatible replacement path (vs ADS1232)
- Integrated low-noise signal conditioning (vs ADS1232)
설계 노트
Route the two differential analog inputs as a tightly coupled pair and keep them away from clocks, relay contacts, inductors, and high-current return paths. Place input filtering as close to the converter pins as practical, but use the manufacturer-recommended filter arrangement to preserve differential settling. The integrated amplifier improves signal conditioning but cannot correct noise that is coupled into the PCB through reference or ground connections.
Place the supply bypass capacitor immediately beside the converter's supply and ground pins, and provide a low-impedance return to the analog supply source. Separate sensitive analog routing from noisy actuator and digital power paths. If a switching regulator supplies the analog rail, evaluate its ripple at the reference and input pins with the complete load, filter, and board layout present.
Treat the reference connection as a precision analog node because reference noise can appear directly in the conversion result. Use short, guarded traces and keep the reference source close enough to avoid cable pickup. If an external reference is used, verify its startup, drift, and noise characteristics. Avoid adding excessive series impedance to the reference or analog-input paths without confirming their effect on acquisition time.
Do not assume that 24-bit nominal resolution guarantees 24-bit usable accuracy. Sensor excitation noise, reference error, input settling, offset calibration, quantization, and the selected 10 SPS or 80 SPS conversion rate contribute to the total error. Validate the complete analog front end at the lowest applicable temperature, because offset and gain errors can change across the operating range.
규정 준수 정보
The converter is not an automotive-qualified device in the listed product information. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from current manufacturer product documentation.