ISL83488IP - 3.3V 250kbps Full-Duplex RS-485 Transceiver | Renesas
부품 번호: ISL83488IP ✓ 활성ISL83488IP 개요
A differential line transceiver is the interface between a logic-level controller and a balanced, noise-resistant communications bus. The ISL83488IP combines a transmit channel, receive channel, bus driver, and differential receiver in one package. RS-485 is commonly used for longer, multipoint industrial networks, while RS-422 is generally associated with dedicated driver and receiver connections. Slew-rate limiting reduces edge speed and electromagnetic interference, making this device especially useful where 250 kbps is sufficient.
The principal operating characteristics are a 3.3 V power requirement, a maximum signaling rate of 250 kbps, full-duplex operation, and support for both RS-485 and RS-422 interfaces. Separate transmit and receive paths allow the node to send and receive simultaneously. The 8-PDIP format supports conventional through-hole PCB layouts, prototyping, and repair of legacy industrial equipment where a surface-mount package would be inconvenient.
Because the transmitter edges are deliberately slew-rate limited, the ISL83488IP favors controlled bus transitions and reduced high-frequency EMI over maximum data throughput. This characteristic makes it suitable for point-to-point RS-422 links, industrial instrumentation, factory equipment, and low-to-moderate-speed RS-485 networks. Designers should still preserve the recommended termination and fail-safe biasing network around the balanced bus.
Typical uses include isolated and non-isolated industrial control links, sensor interfaces, data acquisition systems, motor controllers, and communications between test equipment and peripheral modules. The full-duplex configuration avoids sharing a driver and receiver on the same pair, which simplifies bus topology in point-to-point designs. In a multipoint RS-485 installation, however, only one driver should be active at a time, and the receiver must tolerate an inactive or shorted bus.
For PCB implementation, route the balanced pair together, keep the transceiver close to the connector, and provide a solid ground reference. Decoupling capacitors should connect directly to the supply and ground pins, while surge protection should be placed near the external connector. Verify that cable length, termination, node count, and grounding remain compatible with the intended RS-485 or RS-422 topology.
This product page combines the manufacturer specification, verified package and interface characteristics, compatible family context, practical layout guidance, and a structured replacement comparison. It is intended to help engineers identify the correct electrical function, package, data rate, and board-level integration requirements before committing the ISL83488IP to a new or legacy design.
드롭인 대체품: ISL83488IP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: ISL83488IP (동일 폼 팩터 및 풋프린트) — 차이점: Product Type, Duplex Mode, Maximum Data Rate, Package, Package Type.
ISL83483IP
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
ISL83485IP
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →ISL83490IP
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →ISL83491IP
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →ISL83488IBZ
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ISL83488IP 사양
| 공급 전압 | 3.3 V |
| Maximum Data Rate | 250 kbps |
| Interface Standards | RS-485 and RS-422 |
| Duplex Mode | Full duplex |
| Transceiver Configuration | 1 transmitter and 1 receiver |
| Logic Technology | BiCMOS |
| Output Slew Rate | Slew-rate limited |
| 패키지 | 8-pin PDIP (8-PDIP) |
| 실장 유형 | Through-hole |
| 동작 온도 | -40 C to +85 C |
| Manufacturer | Renesas Electronics |
| Product Family | ISL83483, ISL83485, ISL83488, ISL83490, ISL83491 |
ISL83488IP 8-pin pdip (8-pdip) 핀 구성 가이드
ISL83488IP(8-pin pdip (8-pdip) 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: ISL83488IP.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
ISL83488IP 적합 용도: 6 애플리케이션s: Industrial Sensor Networks, Point-to-Point RS-422 Equipment Links, Factory Automation Control Links, Data Acquisition and Instrumentation, Motor and Power Controller Communication, Legacy Equipment Repair and Retrofit.
Industrial Sensor Networks
The ISL83488IP suits balanced sensor links that must operate from a 3.3 V rail at rates up to 250 kbps. Its full-duplex arrangement permits simultaneous command transmission and measurement return, while the slew-rate-limited driver reduces the severity of fast edge transitions on industrial cabling. Install termination and biasing at the appropriate points in the bus, and route the balanced pair together from the transceiver to the connector. The principal benefit is controlled signaling without requiring a separate driver for each direction.
추천
Point-to-Point RS-422 Equipment Links
For point-to-point RS-422 equipment links, the ISL83488IP provides separate transmit and receive channels at up to 250 kbps from a 3.3 V supply. Full-duplex operation avoids sharing a driver and receiver, simplifying cable and termination planning for dedicated links. Its controlled output transitions are advantageous where EMI-sensitive equipment uses long or imperfect cables. The design should still implement the source and destination terminations specified by the RS-422 system configuration.
추천
Factory Automation Control Links
The ISL83488IP can connect a controller to remote automation equipment over a balanced RS-485 or RS-422 link running at up to 250 kbps. The full-duplex configuration supports simultaneous command and status traffic, and the 3.3 V supply simplifies integration with modern control electronics. Its slew-rate-limited driver helps limit EMI from cable transitions. Engineers should validate node count, cable length, grounding, and protection against the industrial surge environment before production release.
추천
Data Acquisition and Instrumentation
Data acquisition modules can use the ISL83488IP for a reliable balanced connection between measurement electronics and a host controller. The 250 kbps rate is suitable for many multiplexed sensor and status channels, while full-duplex operation allows commands and data to coexist on separate conductor pairs. The 8-PDIP package is convenient for instrument prototypes and repairable industrial hardware. Keep the transceiver near the connector and provide local supply decoupling to preserve signal integrity at the interface boundary.
추천
Motor and Power Controller Communication
The ISL83488IP provides a low-speed balanced command path between a motor controller and supervisory electronics at rates up to 250 kbps. Its 3.3 V operation suits compact control boards, and the controlled driver transitions reduce high-frequency EMI that could interfere with nearby power circuitry. The full-duplex arrangement allows operating commands and fault feedback to be exchanged concurrently. Validate grounding and isolation strategy carefully when the transceiver shares a high-current power stage.
추천
Legacy Equipment Repair and Retrofit
The 8-PDIP package makes the ISL83488IP especially useful for repairing or retrofitting legacy equipment that used through-hole interface ICs. It provides a modern 3.3 V RS-485 and RS-422 function at up to 250 kbps without requiring a surface-mount footprint redesign. Full-duplex operation can simplify replacement of older communication subsystems when the external pin arrangement is compatible. Confirm every net against the family datasheet because related family members can use different duplex and disable configurations.
추천
추천 제품 요약
엔지니어링 참조 데이터: ISL83488IP — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | ISL83483IP | ISL83485IP | ISL83490IP | ISL83491IP | ISL83488IBZ |
|---|---|---|---|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics |
| Package | 8-PDIP | 8-PDIP | 8-PDIP | 8-PDIP | 8-PDIP | 8-LD |
| Supply Voltage | 3.3 V | 3.3 V | 3.3 V | 3.3 V | 3.3 V | 3.3 V |
| Maximum Data Rate | 250 kbps | 250 kbps | 250 kbps | 250 kbps | 250 kbps | 250 kbps |
| Duplex Configuration | Full duplex | Half duplex | Half duplex | Full duplex | Full duplex | Full duplex |
| Interface Standards | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 |
| Output Edge Control | Slew-rate limited | Slew-rate limited | Slew-rate limited | Slew-rate limited | Slew-rate limited | Slew-rate limited |
| Operating Temperature | -40 C to +85 C | -40 C to +85 C | -40 C to +85 C | -40 C to +85 C | -40 C to +85 C | -40 C to +85 C |
| Transmitter and Receiver Disable Controls | Not applicable to applications not requiring Rx and Tx output disable functions | Half-duplex multiplexed configuration | Half-duplex multiplexed configuration | Includes full-duplex output-disable arrangement | Includes full-duplex output-disable arrangement | Same functional configuration as ISL83488 |
주요 차별점
- Separate full-duplex communication paths (vs ISL83483IP)
- Through-hole package preserves existing leaded PCB layouts (vs ISL83488IBZ)
- Simplified full-duplex configuration for point-to-point links (vs ISL83490IP)
설계 노트
Place the ISL83488IP close to the external communication connector and route the balanced pair as a tightly coupled differential pair. Connect supply-decoupling capacitors directly between the device power pin and ground, with the shortest possible return path. Keep the driver outputs and receiver inputs away from switching nodes and high-current power-stage traces to minimize differential noise pickup and ground bounce.
Apply termination according to the selected RS-485 or RS-422 topology rather than adding it indiscriminately at every node. For point-to-point RS-422, terminate the driver end and remote receiver end as specified by the system architecture. For RS-485, use termination at the physical ends of the bus and provide biasing only at one designated location when fail-safe operation is required.
The ISL83488IP is slew-rate limited, so its output transitions are already controlled for lower EMI. Preserve that advantage by keeping stub lengths short, avoiding unnecessary test pads on the balanced lines, and maintaining a continuous ground reference beneath and alongside the cable route. Place surge or other protection at the connector boundary rather than far downstream, where its capacitance could degrade signal quality.
Do not interchange the ISL83488 with half-duplex family members without reviewing the complete pin descriptions. The ISL83488 uses separate receive and transmit paths, while ISL83483 and ISL83485 multiplex those functions. Also do not substitute the ISL83488IBZ on an existing through-hole PCB because the 8-LD surface-mount package requires a different footprint and assembly process.
규정 준수 정보
The manufacturer identifies the ISL83488 as a 3.3 V, 250 kbps, full-duplex RS-485 and RS-422 BiCMOS transceiver. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not identified, so those fields remain unknown.