ISL8485ECB - 5V RS-485/422 Transceiver | Renesas
부품 번호: ISL8485ECB ✗ 단종ISL8485ECB 개요
A line transceiver is an interface IC that converts logic-level signals into balanced differential signals and receives those differential signals back into CMOS-compatible logic. RS-485 and RS-422 belong to differential data-interface families. Their common-mode rejection and noise immunity make them useful for communications over cables, backplanes, and industrial control networks where signal integrity can be affected by motors, relays, and switching equipment.
The ISL8485ECB operates from a 5 V supply and is identified as a one-driver, one-receiver, half-duplex RS-422/RS-485 device. It can operate as a high-speed transceiver or with slew-rate-limited signaling, allowing the same interface family to address EMC-sensitive links and longer, lower-speed connections. Its 8-pin SOIC package supports surface-mount assembly while retaining a widely used lead pitch.
Electrical performance is centered on a maximum signaling rate of 5 Mbps and low power consumption. The ±15 kV HBM ESD rating protects the device from electrostatic discharge encountered during handling and field installation, although it does not replace proper surge-protection design for an installed cable. The receiver and driver combine in one package, reducing board area in nodes that need bidirectional bus communication.
Typical applications include industrial sensor gateways, programmable logic controller communication, factory automation equipment, test and measurement instruments, building-control nodes, and RS-485 field-bus interfaces. In a half-duplex network, the transceiver can support bus management and point-to-point links when the application controls driver enable and receiver enable states.
For PCB implementation, place the transceiver close to the connector or bus header and keep the differential route short and symmetric. Add the termination, biasing, common-mode protection, and decoupling components recommended by the manufacturer datasheet for the selected bus topology. Confirm driver-enable behavior so multiple transmitters do not contend on the same bus.
This product page combines the manufacturer-device description, verified package and interface details, cross-reference findings, and application-specific design guidance to support faster component evaluation and replacement planning.
드롭인 대체품: ISL8485ECB — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
ISL8485EIBZ-T
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ISL8485ECB 사양
| Product Type | RS-485/RS-422 half-duplex line transceiver |
| 공급 전압 | 5 V |
| Driver Count | 1 driver |
| Receiver Count | 1 receiver |
| Supported Standards | RS-485 and RS-422 |
| Maximum Data Rate | 5 Mbps |
| ESD Protection | ±15 kV HBM |
| Operating Mode | Half-duplex |
| 동작 온도 범위 | 0 °C to 70 °C |
| 패키지 | 8-pin SOIC, 5 mm nominal body width |
| 실장 유형 | Surface mount |
| Logic Family | CMOS |
| Driver Configuration | 1/1 transceiver |
| Slew-Rate-Limited Operation | Supported |
| High-Speed Operation | Supported up to 5 Mbps |
ISL8485ECB 8-pin soic, 5 mm nominal body width 핀 구성 가이드
ISL8485ECB(8-pin soic, 5 mm nominal body width 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: ISL8485ECB.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
ISL8485ECB 적합 용도: 6 애플리케이션s: Industrial Sensor Gateway, PLC Communication Module, Test and Measurement Instrument, Building Control Network, Factory Automation Equipment, Remote Sensor Node.
Industrial Sensor Gateway
The ISL8485ECB fits a 5 V industrial sensor gateway that must communicate over an RS-485 field bus while also supporting RS-422 links. Its one-driver, one-receiver arrangement covers bidirectional half-duplex nodes, and the 5 Mbps capability provides headroom for aggregated sensor traffic. The ±15 kV HBM rating strengthens handling robustness, but field cables still require external surge protection. Slew-rate-limited operation can also reduce high-frequency emissions when conducted EMI is more restrictive than maximum throughput.
추천
PLC Communication Module
The ISL8485ECB is appropriate for a programmable logic controller communication module operating from 5 V logic. A single transceiver provides the differential driver and receiver needed for an RS-485 or RS-422 node, while half-duplex control keeps one physical bus usable for command and response traffic. The 5 Mbps maximum rate supports factory automation equipment with short, controlled links. Validate enable timing and termination in the bus controller because concurrent driver activation can produce contention.
추천
Test and Measurement Instrument
The ISL8485ECB can connect laboratory and field-test instruments to an RS-485 or RS-422 controller using a compact 8-pin SOIC footprint. Its 5 Mbps rate supports high-speed data transfer over properly terminated connections, and the driver-receiver combination simplifies bidirectional command exchange. The low-power 5 V architecture aligns with mixed-signal instrumentation. Keep the differential route away from sensitive analog inputs and use the transceiver's slower slew-rate mode when cable length or radiated-emissions requirements dominate.
추천
Building Control Network
The ISL8485ECB suits a 5 V building-control node that communicates with sensors, actuators, or distributed controllers over RS-485 or RS-422. Differential signaling supports reliable communication through building wiring where switching loads can introduce interference, and the 8-pin SOIC package limits board footprint. The device's 0 °C to 70 °C operating range suits many indoor environments but must be checked against room and enclosure temperatures. External protection is important at cable entry points.
추천
Factory Automation Equipment
The ISL8485ECB fits factory automation equipment requiring a compact 5 V differential bus interface for motor controllers, condition-monitoring nodes, or remote I/O. Its one-driver, one-receiver configuration supports half-duplex RS-485 coordination and RS-422 point-to-point links, while 5 Mbps provides substantial throughput for short industrial runs. Use controlled enable logic to prevent bus contention, apply the recommended termination and biasing network, and keep protection devices close to the cable connector.
추천
Remote Sensor Node
The ISL8485ECB can connect a remote 5 V sensor node to a differential sensor network using either RS-485 multidrop wiring or RS-422 point-to-point wiring. The compact 8-pin SOIC package leaves board area for sensing and conditioning circuitry, and the 5 Mbps capability supports a wide range of digitized measurement traffic. At long distances or near high-energy switching equipment, slew-rate-limited signaling can improve EMC behavior. The cable interface should still include appropriately selected transient-voltage protection.
추천
추천 제품 요약
엔지니어링 참조 데이터: ISL8485ECB — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | ISL8485EIBZ-T |
|---|---|---|
| Package | 8-pin SOIC | 8-pin SOIC |
| Brand | Renesas Electronics | Renesas Electronics |
| Product Type | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver |
| Supply Voltage | 5 V | 5.5 V |
| Maximum Data Rate | 5 Mbps | 5 Mbps |
| Driver and Receiver Count | 1 driver, 1 receiver | 1 driver, 1 receiver |
| Operating Mode | Half-duplex | Half-duplex |
주요 차별점
- Higher-rate RS-485/RS-422 interface option (vs MAX485CSA)
- Direct 8-pin SOIC pin-compatible path (vs ISL8485EIBZ-T)
- Field-handling ESD protection (vs ISL8485EIBZ-T)
설계 노트
Route the RS-485 and RS-422 differential pair as a tightly coupled pair with a continuous ground reference, and terminate the transceiver at the connector side of the board. Keep the pair away from switching nodes, relay coils, crystal circuits, and high-current power paths. Use symmetric component placement around the transceiver so parasitic mismatch remains small. Follow the manufacturer's pin-description table for every connection.
Do not enable the driver while another node is transmitting on the same bus. Half-duplex implementations need deterministic driver-enable and receiver-enable control, including enough dead time to prevent contention. Confirm that any system alternative uses the same enable polarity and timing. For long or noisy cables, add external surge protection and evaluate the slower slew-rate mode rather than relying on the internal ESD rating for installation transients.
Place the required 5 V decoupling capacitor immediately beside the transceiver's supply and ground pins, with a short return path to the ground plane. The supply must remain within the device's operating limits during bus transients and startup. Avoid sharing a narrow supply-current path with relay drivers, motors, or other switching loads because disturbance on the 5 V rail can cause receiver errors even when the differential bus itself is well terminated.
규정 준수 정보
No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was identified for this legacy device.