Texas Instruments

ISO113 - 1500Vrms Isolation Amplifier | Texas Instruments

부품 번호: ISO113 ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
10 V to 18 V Vdss 16-CDIP, double-wide sidebraze DIP Package
문의하기 가격 문의
MOQ: 1 |
가격 업데이트: 2026-10-22
볼륨 가격
수량 단가 합계
1 $0 $0.00
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ 모든 가격은 USD 기준입니다

ISO113 개요

The Texas Instruments ISO113 is an internally powered output isolation amplifier rated for continuous 1500Vrms operation, supplied in a 16-pin double-wide 0.6-inch sidebraze DIP package. It provides one isolation-amplifier circuit, a 10V to 18V supply range, and a 1.5V/µs slew rate. The device combines an isolated signal path, isolation barrier, and output-side power in one package.

An isolation amplifier is an analog signal-conditioning component that transfers a measurement from a high-potential or electrically noisy input domain to a grounded output domain while preventing conductive current between those domains. In the hierarchy of electronic components, ISO113 belongs to the isolation-amplifier category, analog signal chain, and instrumentation interface. It is used where ground potentials differ, safety isolation is required, or a sensor signal must cross a high-voltage barrier.

The ISO113's self-contained isolated signal and output power removes the need for a separate isolated power supply on the output side. Its wide barrier-pin spacing and internal insulation support the 1500Vrms continuous AC barrier rating. The 16-CDIP package is a through-hole, double-wide DIP rather than a compact surface-mount isolator. The reported 1.5V/µs slew rate makes it suitable for instrumentation signals requiring a practical response to changing input waveforms.

Barrier capacitance is minimized to reduce AC leakage currents, while 100% barrier breakdown testing is reported to conform to UL1244 test methods. The ISO113 is therefore suited to industrial measurement, sensor-interface, data-acquisition, and power-system signal-isolation systems where the required voltage separation is central to the design.

Typical applications include isolated sensor readout, industrial process measurement, medical-instrument signal conditioning, power-converter feedback isolation, and high-voltage equipment monitoring. The component should be selected only when its 10V to 18V supply, 1500Vrms continuous barrier rating, through-hole package, and available electrical performance meet the system requirements.

For PCB layout, preserve the isolation creepage and clearance defined by the manufacturer datasheet and do not route unrestricted copper across the isolation barrier. Check supply decoupling, input common-mode limits, output loading, and the required safety standard for the finished equipment before production release.

This page combines verified manufacturer and distributor information, package and barrier details, application guidance, and the available substitution search results. Because the supplied data does not establish five pin-compatible drop-in replacements, the alternatives section does not add unverified substitutes.

드롭인 대체품: ISO113 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: ISO113 (동일 폼 팩터 및 풋프린트) — 차이점: Mounting Type, Product Type, RoHS Status.

Texas Instruments
Mounting Type: Through hole
Product Type: Isolation amplifier
RoHS Status: unknown
비교 대상: ISO113 →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

ISO103

✅ 드롭인
Texas Instruments
📦 16-CDIP
Isolation amplifier · Texas Instruments · 1 circuit · 20 kHz · 20 kHz · +10 V · 5600 Vpk · 1500 Vrms

✓ 재고 있음

$201.0702 / 개

데이터시트 보기 →

HCPL-788J-500E

✅ 드롭인
📦 16-CDIP
The comparison result associates a 16-pin package, but does not provide verified ISO113 pin compatibility, isolation rating, supply range, or electrical specifications.

📋 참조 대체품 (카탈로그에 없음)

ISO113-B8

✅ 드롭인 ⚠️ 사양 미검증
📦 16-CDIP
The supplied search result does not verify a separate ISO113-B8 ordering code or establish a distinct pinout and parameter set.

📋 참조 대체품 (카탈로그에 없음)

ℹ️ 1 교차 패키지 부품은 숨겨졌습니다 — 다른 패키지는 PCB 재작업이 필요하며 진정한 드롭인 대체품이 아닙니다. 문의하기 교차 패키지 제안이 필요하면 다음을 참조하십시오.

ISO113 최대 정격 & 전기적 특성

Product Type Output isolation amplifier
Isolation Barrier Rating 1500 Vrms continuous AC
Supply Voltage Range 10 V to 18 V
Minimum Supply Voltage 10 V
Maximum Supply Voltage 18 V
Number of Circuits 1 circuit
Slew Rate 1.5 V/µs
Package Type 16-CDIP, double-wide sidebraze DIP
Package Width 0.6 inch
실장 유형 Through-hole
Number of Terminals 16
Barrier Testing 100% barrier breakdown testing
Barrier Test Method UL1244 test methods
Low Barrier Capacitance Yes; minimizes AC leakage currents
동작 온도 범위 -25 °C to +85 °C
RoHS 상태 Compliant
Manufacturer Classification Instrumentation, operational amplifiers, buffer amplifiers
Safe Operating Area Not applicable; ISO113 is not a power semiconductor
수명 주기 상태 Active based on current distributor product listings

ISO113 0.6 inch 핀 구성 가이드

ISO113(0.6 inch 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.

ISO113의 0.6 inch 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: ISO113.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

ISO113 적합 용도: 7 애플리케이션s: Industrial Sensor Signal Conditioning, Power Converter Feedback Isolation, High-Voltage Equipment Monitoring, Data Acquisition Systems, Medical Instrument Signal Conditioning, Laboratory and Process Measurement, Legacy Industrial Control Interfaces.

🏭

Industrial Sensor Signal Conditioning

The ISO113 fits industrial sensor interfaces that need to transfer a measurement across an isolation barrier. Its 1500Vrms continuous AC barrier rating and internally powered output side can reduce the need for a separate isolated output supply. The 10V to 18V supply range and 1.5V/µs slew rate support instrumentation systems, while the wide barrier spacing supports careful PCB layout. Confirm the input common-mode range and sensor output amplitude against the manufacturer datasheet before implementation.

⚡

Power Converter Feedback Isolation

The ISO113 can be used to isolate feedback signals in power-converter and power-supply monitoring circuits. Its internally powered output side simplifies the isolated signal path, while the 1500Vrms continuous AC barrier rating supports designs with a substantial potential difference between input and output domains. The engineer must still verify isolation topology, loop stability, input range, and the final system creepage and clearance requirements.

🖥️

High-Voltage Equipment Monitoring

The ISO113 is appropriate for monitoring circuits that must safely transfer a measurement away from high-voltage equipment. The 1500Vrms continuous AC barrier rating, low barrier capacitance, and 100% barrier breakdown testing are relevant to reinforced separation in instrumentation equipment. The component is not a standalone safety approval, so the final product must meet its applicable insulation, clearance, creepage, and fault-safety requirements.

📟

Data Acquisition Systems

The ISO113 can isolate analog channels before they reach a data-acquisition front end, helping prevent ground-current coupling between field instrumentation and measurement electronics. Its internally powered output and 16-CDIP through-hole package are useful for legacy or industrial acquisition boards with adequate board spacing. The 10V to 18V supply requirement and 1.5V/µs slew rate should be checked against the acquisition bandwidth and output settling requirements.

💊

Medical Instrument Signal Conditioning

The ISO113 may be evaluated for medical instrumentation signal paths where patient-side and equipment-side circuits require isolation. Its 1500Vrms continuous AC barrier rating and low barrier capacitance are useful attributes, but the supplied data does not claim medical certification or AEC-Q100 qualification. Medical use therefore requires a system-level risk assessment, applicable standards review, validation, and confirmation that the final device satisfies the required isolation and leakage limits.

🔬

Laboratory and Process Measurement

The ISO113 supports laboratory and process-measurement designs where a sensor, transducer, or control signal must cross an electrically noisy or high-potential boundary. The single-channel output isolation amplifier structure, wide barrier spacing, and through-hole package make it suitable for equipment with planned isolation creepage and clearance. Designers should use low-leakage input networks, provide the specified supply range, and verify accuracy and stability in the complete analog chain.

🛠️

Legacy Industrial Control Interfaces

The ISO113 is suitable for maintaining or repairing legacy industrial control equipment that uses a 16-CDIP isolation-amplifier footprint. Its through-hole double-wide DIP package supports hand installation and socket or PCB compatibility, while the internal isolated output power can simplify retrofit designs. Before substitution, confirm the exact pinout, supply polarity, isolation rating, bandwidth, and component availability because the supplied data does not establish a complete second-source list.

What is the ISO113 and what does it do?
The Texas Instruments ISO113 is a single-circuit output isolation amplifier with an internal isolated signal path and output power. According to the Texas Instruments ISO113 datasheet, it provides a continuous 1500Vrms AC barrier rating and is packaged in a 16-CDIP double-wide 0.6-inch sidebraze DIP. It is intended to transfer instrumentation signals across an isolation barrier while reducing conductive coupling between input and output domains.
What is the isolation voltage rating of ISO113?
The ISO113 is rated for 1500Vrms continuous AC barrier operation. The verified Texas Instruments datasheet states that wide barrier-pin spacing and internal insulation support this rating, while 100% barrier breakdown testing follows UL1244 test methods. The 1500Vrms value is a barrier rating and should not be treated as a complete equipment safety certification; the finished system still requires application-specific creepage, clearance, and insulation validation.
What supply voltage does ISO113 require?
The ISO113 operates from a 10V to 18V supply, according to the verified datasheet information. This makes it suitable for instrumentation systems using a nominal supply within that range. The supply must remain within the stated limits, and input common-mode voltage, output loading, and power-supply decoupling must be checked against the manufacturer datasheet before the device is used.
Where can I download the ISO113 datasheet PDF?
The ISO113 datasheet PDF is available through the verified Texas Instruments document hosted by DigiKey at https://media.digikey.com/pdf/Data%20Sheets/Texas%20Instruments%20PDFs/ISO113.pdf. The document contains the isolation amplifier specifications, application information, barrier details, and package information. Use the manufacturer document as the controlling reference for pinout, electrical limits, and recommended application circuits.
Where can I find the ISO113 pinout?
The ISO113 pinout is published in the manufacturer datasheet and should be checked there before wiring or PCB layout. The verified distributor data identifies the device as a 16-CDIP through-hole package, but the supplied excerpts do not reproduce every pin name. Therefore, individual pin assignments beyond the verified package identification are marked as data needed rather than inferred. The complete ISO113 PDF is the authoritative pinout source.
Is ISO113 suitable for industrial sensor measurement?
Yes, ISO113 is suitable for industrial sensor measurement when the system needs signal isolation and the stated electrical limits are acceptable. Its internally powered output side, 1500Vrms continuous AC barrier rating, low barrier capacitance, and 10V to 18V supply range support measurement across high-potential domains. The input signal amplitude, common-mode range, isolation topology, and equipment safety requirements must still be verified from the datasheet.
What is the ISO113 slew rate?
The verified ISO113 datasheet data lists a slew rate of 1.5V/µs. This specification describes how quickly the amplifier output can change in response to a signal step. It is relevant to instrumentation bandwidth and transient response, but it does not by itself establish the complete signal bandwidth, settling time, or accuracy of an external circuit. Confirm those parameters against the full manufacturer datasheet for the operating gain and supply conditions.
Can ISO113 be used in a 5V instrumentation system?
The ISO113 should not be assumed compatible with a 5V-only system because its verified supply-voltage range is 10V to 18V. The device therefore requires a supply within that range. A separate regulator may be needed, but any converter or regulator must preserve the isolation architecture and provide adequate startup, decoupling, noise, and grounding behavior. The verified data does not establish a 5V ISO113 variant.
Is ISO113 RoHS compliant?
The distributor product information identifies ISO113 as RoHS compliant. RoHS status concerns restricted substances in the component and does not by itself prove that the assembled product complies with every applicable safety, environmental, or sector-specific requirement. Engineers should also verify the current manufacturer declarations and any system-level insulation or hazardous-substance requirements before release.
What is the operating temperature range of ISO113?
The verified distributor listing specifies an operating temperature range of -25 °C to +85 °C for ISO113. This range must be observed at the device's relevant operating conditions and verified against the complete manufacturer datasheet for temperature gradients, package mounting, and system-level requirements. The ISO113 is not represented here as an automotive-qualified AEC-Q100 device because no such qualification appears in the supplied data.
What is the best drop-in replacement for ISO113?
The supplied cross-reference search does not verify five pin-compatible drop-in replacements for ISO113. A replacement must match the 16-CDIP footprint, pin-to-pin connectivity, isolation architecture, supply range, isolation rating, bandwidth, and intended safety application. Because no candidate is confirmed by the provided data, engineers should consult the manufacturer and validate a specific replacement rather than treating a generic isolation amplifier as interchangeable.
Can IL612-3E replace ISO113?
IL612-3E should not be treated as a verified drop-in replacement for ISO113. The comparison result describes IL612-3E as an 8-pin surface-mount digital isolator, while ISO113 is a 16-CDIP output isolation amplifier. The package, pin count, isolation function, and signal architecture differ. Although both provide isolation functions, a functional relationship does not establish pin compatibility or safe PCB drop-in replacement.
ISO113 vs ISO103: which isolation amplifier fits the design?
ISO113 should be selected when the verified requirements include a 16-CDIP output isolation amplifier, 10V to 18V supply, and 1500Vrms continuous AC barrier rating. ISO103 may be relevant for a different design, but the supplied search result does not establish ISO103 as a pin-compatible replacement or provide complete ISO103 electrical data. Compare the manufacturer datasheets, especially isolation topology, supply requirements, pinout, bandwidth, and package.
Where can I buy ISO113 online?
ISO113 is available through the verified Texas Instruments distributor listings, including DigiKey and Mouser. The listings provide current inventory and commercial information that may change over time. The supplied data confirms product availability pages but does not provide a numeric price or guaranteed stock quantity, so this page does not quote an unverified price. Contact the distributor or use the linked product page for a live quote and delivery estimate.
What is the price of ISO113 as of 2026-10-22?
A verified numeric ISO113 price as of 2026-10-22 was not included in the supplied distributor data. The verified results provide product pages and snippets but no price value, so pricing cannot be responsibly estimated. Request a current quote from DigiKey or Mouser, and confirm quantity, tax, shipping, and lead time before purchasing. Any commercial price should be treated as distributor-specific and time-sensitive.
What is the lead time for ISO113?
A verified numeric ISO113 lead time as of 2026-10-22 was not supplied. DigiKey and Mouser list the component, but the available snippets do not state a delivery interval or guaranteed inventory. Lead time depends on distributor stock, order quantity, packaging, and manufacturing status. Check the live distributor offer or request a quotation for the exact quantity rather than relying on an unverified lead-time estimate.
What are the key ISO113 specifications engineers should know?
The key verified ISO113 specifications are one isolation-amplifier circuit, 1500Vrms continuous AC barrier rating, 10V to 18V supply range, 1.5V/µs slew rate, and a 16-CDIP double-wide 0.6-inch sidebraze through-hole package. The distributor listing also specifies -25 °C to +85 °C operating temperature and RoHS compliance. Check the manufacturer datasheet for complete input, output, accuracy, bandwidth, and isolation details.

엔지니어링 참조 데이터: ISO113 — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the ISO113 when the design specifically needs a single output isolation-amplifier channel, a 1500Vrms continuous AC barrier rating, a 10V to 18V supply, and a 16-CDIP through-hole footprint. Its internally powered output is useful for instrumentation systems that would otherwise require additional isolated power. Do not select a generic digital isolator or a surface-mount isolation amplifier as a drop-in replacement unless its exact pinout, isolation architecture, voltage rating, accuracy, bandwidth, and safety requirements are verified. ISO103 may be worth evaluating for a related design, but the supplied data does not establish that it is a pin-compatible replacement. HCPL-788J-500E likewise requires full datasheet verification. For a production ISO113 board, confirm current distributor stock, obtain the manufacturer datasheet, and complete creepage, clearance, leakage, and system-safety validation.

대체품과의 비교

파라미터 이 제품 ISO103 HCPL-788J-500E ISO113-B8
Product Type Output isolation amplifier Isolation amplifier; details incomplete Isolation-related device; details incomplete Ordering-code details unavailable
Brand Texas Instruments Texas Instruments Avago Technologies Texas Instruments

주요 차별점

  • Internally powered output side (vs IL612-3E)
  • Continuous isolation rating (vs ISO103)
  • Through-hole isolation-amplifier package (vs HCPL-788J-500E)
  • Specified slew rate (vs ISO103)

설계 노트

Maintain the manufacturer-specified creepage and clearance around the 1500Vrms isolation barrier. Keep copper, solder mask, test pads, and mechanical hardware from bridging the input-side and output-side regions. The double-wide 16-CDIP package provides physical separation, but PCB routing must preserve that separation rather than treating the DIP body outline alone as sufficient insulation.

Provide a supply within the verified 10V to 18V ISO113 range and place bypass capacitors close to the device power pins according to the manufacturer application guidance. Check startup behavior and supply noise at the isolated output. Because the device is internally powered, the output-side supply arrangement still requires correct grounding and decoupling; internal isolation power does not remove the need for system-level layout discipline.

Do not substitute a generic digital isolator or a different-package isolation amplifier as a drop-in replacement. ISO113 is a 16-CDIP output isolation amplifier with a 1500Vrms continuous AC barrier rating; IL612-3E, for example, is listed as an 8-pin surface-mount digital isolator. Confirm pinout, supply range, isolation rating, bandwidth, accuracy, and package footprint against the full datasheet before any replacement decision.

Keep the isolated input loop small and use low-leakage, low-tolerance feedback and bias components where the measurement accuracy is important. The ISO113 datasheet highlights low barrier capacitance to minimize AC leakage currents, but external PCB leakage, contamination, and grounding still affect system performance. Validate common-mode range and leakage in the final instrumentation enclosure, especially when the barrier operates near its continuous rating.

규정 준수 정보

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

RoHS compliance is stated in the verified distributor product data. No REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification claim appears in the supplied data. The 100% barrier breakdown testing statement refers to UL1244 test methods and does not constitute a complete product certification.

데이터 검증일: 2026-10-22 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

ISO113 datasheet Texas Instruments ISO113 ISO113 1500Vrms isolation amplifier ISO113 16-CDIP ISO113 internally powered output isolation amplifier ISO113 industrial sensor measurement ISO113 high voltage equipment monitoring ISO113 vs ISO103 ISO113 drop-in replacement ISO113 buy online ISO113 price ISO113 pinout What is ISO113 used for? Can IL612-3E replace ISO113? ISO113 lead time

관련 부품 & 용어

Texas Instruments ISO113 output isolation amplifier analog signal conditioner isolation amplifier isolated signal path isolated output power 1500Vrms continuous AC barrier 10V to 18V supply 1.5V/µs slew rate 16-CDIP double-wide sidebraze DIP 0.6-inch package UL1244 test methods low barrier capacitance barrier breakdown testing industrial instrumentation sensor interface power-converter feedback data acquisition medical instrumentation creepage and clearance RoHS DigiKey Mouser
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기