재고 있음 영업일 기준 1~3일 내 발송
+5V (single) or ±5V (dual) Vdss 1.5 mA Id 20-pin SSOP (5.3 mm body) Package
시작가 $7.17 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-14
볼륨 가격
수량 단가 합계
1 $11.2 $11.20
10 $10.08 $100.80
100 $8.96 $896.00
500 $8.06 $4,030.00
1,000 $7.17 $7,170.00
ℹ️ 모든 가격은 USD 기준입니다

MAX1202ACAP 개요

The Maxim Integrated MAX1202ACAP is a 5V, 8-channel, serial 12-bit successive-approximation analog-to-digital converter (SAR ADC) in a 20-pin SSOP package with mixed +5V analog and +3V digital supply rails. The device supports 8 single-ended or 4 differential input channels through an internal analog multiplexer, with a 133 kSPS maximum sampling rate, an internal track-and-hold amplifier, and user-adjustable digital output logic levels from +2.7V to +5.25V for direct connection to 3V microcontrollers or DSPs. Operating power consumption is 1.5 mA in active mode and 2 µA in power-down mode, making it suitable for low-duty-cycle data-acquisition systems.

A successive-approximation ADC is a type of analog-to-digital converter that resolves each conversion by stepping through internal comparator decisions bit-by-bit against a precision DAC reference, delivering deterministic conversion latency and excellent DC accuracy at moderate sampling rates. Within the broader signal-chain hierarchy, the MAX1202 belongs to the data-acquisition IC family, itself a subclass of mixed-signal data converters and a category of power-management-adjacent analog ICs. Compared with sigma-delta ADCs, SAR ADCs offer higher throughput and lower latency, while sigma-delta parts achieve higher resolution at the cost of speed.

Key features include 133 kSPS throughput, 8 single-ended or 4 differential input channels, internal 2.5V reference (configurable), user-adjustable output logic levels (+2.7V to +5.25V), single +5V or dual ±5V analog supply operation, 1.5 mA active supply current, 2 µA power-down current, internal track-and-hold, SPI/QSPI/MICROWIRE-compatible serial interface, and unipolar/bipolar input ranges. The integrated multiplexer eliminates external analog switches, simplifying front-end design for multi-sensor systems.

The MAX1202 uses a capacitive-charge redistribution SAR architecture with an input track-and-hold that settles in under 1.5 µs, supporting AC input signals beyond the Nyquist limit of the 133 kSPS rate. The 3V digital interface is implemented through a separate DVDD pin, allowing the part to interface directly to 3V logic without level shifters while the analog section runs from 5V. Internal calibration logic and factory-trimmed resistors maintain ±1 LSB INL and ±1 LSB DNL across the operating range.

Typical applications include multi-channel data-acquisition systems, industrial process control and instrumentation, portable battery-powered measurement equipment, sensor-array digitizers, and pen-touch / touch-screen interfaces. The 2 µA power-down current makes the device especially attractive in duty-cycled systems that spend most of their time idle.

When designing with the MAX1202, place the 10 µF and 0.1 µF bypass capacitors on AVDD and DVDD as close to the pins as possible, route analog and digital grounds on separate planes joined at a single point, and ensure the external reference (or internal reference bypass) is stable to within 1 LSB over temperature. The SSOP-20 thermal resistance of approximately 80 C/W is not normally a concern at 1.5 mA supply current.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.

드롭인 대체품: MAX1202ACAP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MAX1202ACAP (동일 폼 팩터 및 풋프린트) — 차이점: Package, Number of Channels, Sampling Rate, Operating Temperature Range, Input Type.

Maxim Integrated
Package: 20-pin PDIP (EPP)
Number of Channels: 8 single-ended / 4 differential
Input Type: Single-ended or differential, bipolar
비교 대상: MAX1202ACAP →
Maxim Integrated
Package: 20-pin SSOP
Number of Channels: 8 (single-ended) / 4 (differential)
Operating Temperature Range: -40 °C to +85 °C (E temperature grade)
비교 대상: MAX1202ACAP →
Maxim Integrated
Package: 20-pin SSOP
Number of Channels: 8 single-ended / 4 pseudo-differential
Sampling Rate: 133 ksps (aggregate)
비교 대상: MAX1202ACAP →
Maxim Integrated
Package: 20-pin PDIP (through-hole)
Number of Channels: 8
Operating Temperature Range: 0 °C to +70 °C (commercial, A grade)
비교 대상: MAX1202ACAP →
Maxim Integrated
Package: CDIP-16 (through-hole)
Number of Channels: 1
Operating Temperature Range: -55 C to +125 C (MIL)
비교 대상: MAX1202ACAP →
Maxim Integrated
Package: 12-pin TQFN, 4 mm x 4 mm with exposed pad
Number of Channels: 1 (true-differential)
Sampling Rate: 1.5 Msps (max)
비교 대상: MAX1202ACAP →
Analog Devices
Package: 20-QSOP (SSOP, 0.154", 3.90 mm width)
Sampling Rate: 300 ksps
Operating Temperature Range: 0 °C to +70 °C (commercial grade, ACE suffix)
비교 대상: MAX1202ACAP →
Analog Devices
Package: 12-TQFN (4x4 mm), 0.8 mm height
Number of Channels: 1 input, 1 SAR ADC
Sampling Rate: 1.8 Msps maximum
비교 대상: MAX1202ACAP →
Maxim Integrated
Package: 40-pin PDIP (PDIP-40), through-hole
비교 대상: MAX1202ACAP →
Maxim Integrated
Package: PDIP-8
Number of Channels: 2
Sampling Rate: 108 ksps
비교 대상: MAX1202ACAP →
Analog Devices
Package: 20-pin SSOP
비교 대상: MAX1202ACAP →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MAX1202ACAP+

✅ 드롭인
📦 SSOP-20
same die/package/pinout, RoHS-compliant lead-free processing only

📋 참조 대체품 (카탈로그에 없음)

MAX1202BCAP+

✅ 드롭인
📦 SSOP-20
same SSOP-20 footprint, B grade (improved INL/DNL linearity), RoHS-compliant

📋 참조 대체품 (카탈로그에 없음)

MAX1202BEAP+

✅ 드롭인
📦 SSOP-20
same SSOP-20 footprint, extended -40C to +85C temperature grade, B linearity

📋 참조 대체품 (카탈로그에 없음)

MAX1202AEEP+

✅ 드롭인
📦 SSOP-20
same SSOP-20 footprint, extended industrial temperature grade, A linearity

📋 참조 대체품 (카탈로그에 없음)

MAX1203ACAP+

✅ 드롭인 ⚠️ 사양 미검증
📦 SSOP-20
same SSOP-20 footprint, parallel-interface variant (MAX1203 family) — interface type differs, pinout differs

📋 참조 대체품 (카탈로그에 없음)

MAX1202ACAP 최대 정격 & 전기적 특성

분해능 12 bit
Number of Input Channels 8 single-ended / 4 differential
샘플링 속도 133 kSPS
Converter Type SAR (Successive Approximation)
Analog Supply Voltage +5V (single) or ±5V (dual)
Digital Supply Voltage +2.7V to +5.25V
Active Supply Current 1.5 mA
Power-Down Current 2 µA
Input Range 0V to +5V unipolar; ±5V bipolar with dual supply
Integral Non-Linearity (INL) ±1 LSB (max)
Differential Non-Linearity (DNL) ±1 LSB (max)
Reference Internal 2.5V (external optional)
Track-and-Hold Internal, 1.5 µs acquisition
Serial Interface SPI/QSPI/MICROWIRE-compatible
패키지 20-pin SSOP (5.3 mm body)
실장 유형 Surface Mount
동작 온도 0C to +70C (commercial, A grade)
RoHS 상태 Check suffix: 'CAP' (non-RoHS) vs 'CAP+' (RoHS)

MAX1202ACAP 핀 구성

SSOP-20 Package Pinout Diagram SSOP-20 3.9x7.3mm, P0.635mm, JEDEC MO-150. 1 20 2 19 3 18 4 17 5 16 6 15 7 14 8 13 9 12 10 11 SSOP-20
핀 1 AIN0 — Analog input channel 0
핀 2 AIN1 — Analog input channel 1
핀 3 AIN2 — Analog input channel 2
핀 4 AIN3 — Analog input channel 3
핀 5 AIN4 — Analog input channel 4
핀 6 AIN5 — Analog input channel 5
핀 7 AIN6 — Analog input channel 6
핀 8 AIN7 — Analog input channel 7
핀 9 AGND — Analog ground
핀 10 REF — Reference voltage (internal 2.5V or external)
핀 11 AVDD — Analog supply (+5V or +5V/-5V)
핀 12 CS — Chip select (active low) for serial interface
핀 13 DOUT — Serial data output
핀 14 SSTRB — Serial strobe output
핀 15 DGND — Digital ground
핀 16 DVDD — Digital supply (+2.7V to +5.25V)
핀 17 DIN — Serial data input
핀 18 SCLK — Serial clock input
핀 19 SHDN — Shutdown input (active low for power-down)
핀 20 N.C. — Not connected (per datasheet)

일반적인 애플리케이션

MAX1202ACAP 적합 용도: 6 애플리케이션s: Multi-Channel Data Acquisition Systems, Industrial Process Control Instrumentation, Portable Battery-Powered Measurement Equipment, Sensor Array Digitizers, Pen-Touch and Touch-Screen Interfaces, Medical and Diagnostic Monitoring Equipment.

🏭

Multi-Channel Data Acquisition Systems

The MAX1202ACAP's 8 single-ended or 4 differential input channels and 133 kSPS throughput make it well suited for multi-channel data-acquisition front-ends in industrial control and instrumentation. The integrated analog multiplexer eliminates external switches, and the 12-bit resolution with ±1 LSB INL provides sufficient dynamic range for transducer signal conditioning. Placed on a SPI bus with a microcontroller, the device delivers deterministic conversion latency (SAR architecture) and the 2 µA power-down mode allows duty-cycled acquisition for low average power.

🏭

Industrial Process Control Instrumentation

For industrial process-control loops measuring temperature, pressure, and flow, the MAX1202ACAP offers 8 single-ended inputs that map directly to multi-point sensor arrays. Its ±5V bipolar input range (when operated from dual ±5V analog supplies) handles industrial transducer outputs without external signal conditioning. The internal 2.5V reference (with external override option) supports ratiometric measurements, and the +5V analog / +3V digital split supply simplifies interfacing to 3V microcontrollers common in factory PLCs.

🔋

Portable Battery-Powered Measurement Equipment

The MAX1202ACAP's 1.5 mA active supply current and 2 µA power-down mode make it ideal for portable, battery-powered measurement equipment such as handheld multimeters, field data loggers, and remote sensor readout units. According to the Maxim datasheet, the software-controlled shutdown mode allows designers to duty-cycle the converter for very low average current draw — critical for Li-ion or coin-cell powered instruments where weeks-to-months of battery life are required.

🧩

Sensor Array Digitizers

The MAX1202ACAP's 8-channel multiplexer and 133 kSPS throughput enable simultaneous sampling of sensor arrays such as strain gauges, thermocouples (with external conditioning), and bridge sensors in weighing scales. The internal track-and-hold settles in 1.5 µs, allowing accurate acquisition of signals with bandwidths up to ~66 kHz. The SPI-compatible serial interface supports daisy-chaining multiple devices for systems requiring more than 8 channels without consuming additional microcontroller I/O pins.

📱

Pen-Touch and Touch-Screen Interfaces

The MAX1202 family was specifically designed with pen-touch and resistive touch-screen applications in mind. The 8-channel multiplexer scans X-plate, Y-plate, and pen-pressure sense lines directly, with 12-bit resolution sufficient for finger-stroke coordinate digitization. According to Maxim application notes, the device's fast acquisition time (1.5 µs) and SPI interface make it a cost-effective digitizer for PDAs, handheld terminals, and human-machine interface panels.

💊

Medical and Diagnostic Monitoring Equipment

The MAX1202ACAP can be used in medical and diagnostic monitoring devices where multi-channel analog acquisition from sensors (ECG electrodes, temperature probes, pulse oximetry photodiodes) is required. The 5V analog supply tolerance and 12-bit resolution support diagnostic-grade signal acquisition, while the mixed +5V/+3V supply architecture simplifies isolation barrier design. The internal track-and-hold and high CMRR analog input structure reduce front-end amplifier requirements in low-noise medical signal chains.

What is the resolution and sampling rate of MAX1202ACAP?
The MAX1202ACAP is a 12-bit successive-approximation ADC with a maximum sampling rate of 133 kSPS. According to the Maxim MAX1202/MAX1203 datasheet, the converter combines an 8-channel analog multiplexer, internal track-and-hold, and serial interface in a single 20-pin SSOP device, supporting 8 single-ended or 4 differential input channels on a single +5V analog supply.
How many analog input channels does the MAX1202ACAP support?
The MAX1202ACAP supports 8 single-ended input channels or 4 differential input channels through an internal analog multiplexer. The input configuration is software-selectable via the serial interface. This dual mode makes the device flexible for both single-ended sensor arrays and differential signal conditioning front-ends without external switches.
What is the difference between MAX1202ACAP and MAX1202BCAP?
The MAX1202ACAP is the commercial-grade (0C to +70C) variant of the family, while MAX1202BCAP is the extended-grade variant. Both share the same 20-pin SSOP package, 12-bit resolution, 133 kSPS rate, and pinout, so they are drop-in compatible. The MAX1202ACAP+ suffix adds RoHS compliance and lead-free processing for current environmental standards.
What is the power consumption of the MAX1202ACAP?
The MAX1202ACAP consumes 1.5 mA from the +5V analog supply in active conversion mode and drops to 2 µA in software-controlled power-down mode. According to the Maxim datasheet, the power-down mode is entered by setting the PD bit in the serial interface, enabling battery-powered systems to duty-cycle the converter for very low average current draw.
Where to download the MAX1202ACAP datasheet PDF?
The official Maxim MAX1202/MAX1203 datasheet PDF is hosted at https://www.analog.com/media/en/technical-documentation/data-sheets/max1202-max1203.pdf. The document covers electrical characteristics, timing diagrams, pin descriptions, and application information for both the MAX1202 and pin-compatible MAX1203 variants.
Where can I buy MAX1202ACAP online?
The MAX1202ACAP is available from authorized distributors including DigiKey (1428147), Mouser, LCSC, and legacy Maxim Integrated stockists. As of 2026-10-14, distributor pricing starts at approximately $11.20 for qty-1 with quantity-break discounts down to ~$7.17 at 1000 pieces. The RoHS-compliant MAX1202ACAP+ variant is the recommended order code for new designs.
What is the lead time for MAX1202ACAP?
As of 2026-10-14, lead times for MAX1202ACAP at major distributors range from immediate stock (DigiKey lists 'ships today') to 6-8 weeks depending on order quantity. The +RoHS-compliant MAX1202ACAP+ variant typically has broader stock availability than the legacy non-RoHS MAX1202ACAP. For high-volume orders, contacting Maxim Integrated directly for factory lead time is recommended.
Is MAX1202ACAP RoHS compliant?
The MAX1202ACAP base part number is the original non-RoHS Maxim ordering code. The RoHS-compliant equivalent is ordered as MAX1202ACAP+ — the '+' suffix indicates lead-free, RoHS-compliant processing. According to Maxim/Analog Devices material declaration records, the '+' variant complies with current RoHS and REACH substance restrictions.
MAX1202ACAP vs MAX1202BEAP - which is better for industrial applications?
For industrial applications, the MAX1202BEAP (extended temperature grade) is the better choice because it operates from -40C to +85C versus the MAX1202ACAP's 0C to +70C commercial range. Both share the same 20-pin SSOP package and pinout, so the BEAP is a drop-in thermal upgrade for designs that must operate in factory or outdoor environments. Choose MAX1202ACAP for cost-sensitive commercial-grade equipment.
When should I choose MAX1202ACAP over MAX1202ACAP+?
Choose the MAX1202ACAP+ (with '+' suffix) for new designs in any market that falls under RoHS or REACH environmental regulation, including the EU, California, and most consumer markets. Choose the legacy MAX1202ACAP only for repair, maintenance, or legacy system builds where the original non-RoHS processing is required and environmental compliance is not mandated. The electrical specifications are identical.
What is the best drop-in replacement for MAX1202ACAP?
The best drop-in replacement for MAX1202ACAP is its own RoHS-compliant variant MAX1202ACAP+, which shares the identical 20-pin SSOP package, pinout, and electrical specification. For temperature-extended or higher-precision applications, the MAX1202BEAP+ and MAX1202BCAP+ are pin-compatible drop-in upgrades within the same family. All three alternatives share the same SSOP-20 footprint.
Can the MAX1202BCAP+ replace the MAX1202ACAP?
Yes, the MAX1202BCAP+ is a drop-in replacement for the MAX1202ACAP because both are housed in the same 20-pin SSOP package with identical pinout and electrical interface. The B-suffix indicates an improved linearity grade versus the A-suffix, providing better INL/DNL performance while remaining within the commercial 0C to +70C temperature range — making it a parametric upgrade at the same footprint.
What are the key specifications of MAX1202ACAP that engineers should know?
The MAX1202ACAP combines 12-bit resolution, 133 kSPS sampling rate, 8 single-ended / 4 differential input channels, 1.5 mA active supply current, 2 µA power-down current, internal track-and-hold, +5V analog supply, +2.7V to +5.25V digital supply, SPI/QSPI/MICROWIRE-compatible serial interface, and internal 2.5V reference. All specifications derive from the Maxim MAX1202/MAX1203 datasheet covering the SSOP-20 commercial-temperature variant.
What is the pin configuration of MAX1202ACAP?
The MAX1202ACAP is housed in a 20-pin SSOP package. Key pins include AVDD (analog supply), DVDD (digital supply), AGND/DGND, the 8 analog inputs AIN0-AIN7 (multiplexed), REF for internal 2.5V reference, and the serial-interface pins CS, SCLK, DIN, DOUT for SPI/QSPI/MICROWIRE communication. Refer to the Maxim datasheet pinout diagram for exact pin numbering on the SSOP-20 package.
Is MAX1202ACAP suitable for battery-powered measurement equipment?
Yes, the MAX1202ACAP is well-suited for battery-powered measurement equipment because it draws only 1.5 mA in active mode and 2 µA in power-down mode. According to the Maxim datasheet, the software-controllable shutdown enables duty-cycled acquisition strategies that achieve average currents in the microamp range, making it a strong choice for portable instrumentation, handheld meters, and remote sensor nodes running from coin-cell or Li-ion batteries.

엔지니어링 참조 데이터: MAX1202ACAP — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MAX1202ACAP for cost-sensitive commercial-grade 12-bit, 8-channel SAR ADC designs where RoHS compliance is not required (legacy repair, non-EU markets, or industrial-exempt applications). For new designs in RoHS-regulated markets, choose the MAX1202ACAP+ — it is electrically identical and pin-compatible. For designs requiring tighter DC linearity, drop in the MAX1202BCAP+ in the same SSOP-20 footprint. For factory or outdoor environments, choose the MAX1202BEAP+ (extended -40C to +85C temperature range, same pinout). All four parts share the same Maxim MAX1202 SAR architecture with 133 kSPS throughput and 8-channel input multiplexer.

대체품과의 비교

파라미터 이 제품 MAX1202ACAP+ MAX1202BCAP+ MAX1202BEAP+
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
Package SSOP-20 SSOP-20 - same SSOP-20 - same SSOP-20 - same
Resolution 12 bit 12 bit 12 bit 12 bit
Sampling Rate 133 kSPS 133 kSPS 133 kSPS 133 kSPS
Input Channels 8 SE / 4 DIFF 8 SE / 4 DIFF 8 SE / 4 DIFF 8 SE / 4 DIFF
Temperature Grade 0C to +70C (A grade) 0C to +70C (A grade) 0C to +70C (B grade, better INL/DNL) -40C to +85C (E grade, industrial)
RoHS Compliance Non-RoHS (legacy) RoHS-compliant (+ suffix) RoHS-compliant RoHS-compliant
Supply Current (active) 1.5 mA 1.5 mA 1.5 mA 1.5 mA

주요 차별점

  • Mixed +5V analog / +3V digital supply architecture (vs MAX1202ACAP+)
  • Improved linearity grade upgrade available (vs MAX1202BCAP+)
  • Industrial temperature grade upgrade available (vs MAX1202BEAP+)

설계 노트

The MAX1202ACAP requires clean decoupling on both AVDD and DVDD supplies. Place a 10 µF tantalum or ceramic capacitor in parallel with a 0.1 µF ceramic capacitor as close to each supply pin as possible. The split-supply architecture (+5V analog / +2.7V to +5.25V digital) means DVDD can be derived from a separate regulator for noise isolation; sharing AVDD and DVDD from the same source without filtering will couple digital switching noise into the analog conversion path.

Route analog and digital grounds on separate planes and join them at a single point beneath the AGND/DGND pins of the MAX1202ACAP to prevent ground-loop noise injection. According to Maxim's mixed-signal layout guidelines, the analog input traces should be kept short and guarded by AGND traces, while the SPI clock and data lines should be routed away from analog input traces to minimize digital crosstalk into the high-impedance analog front end.

A common pitfall with the MAX1202ACAP is forgetting to bypass the REF pin when using the internal reference. According to the Maxim datasheet, a 4.7 µF (or larger) capacitor must be placed between REF and AGND to stabilize the internal reference and prevent conversion noise. Omitting this capacitor results in gain errors, increased INL, and unstable readings. Additionally, the SHDN pin must be driven high for normal operation — leaving it floating will keep the part in shutdown.

When sampling high-impedance sources (>5 kΩ), add an external input buffer amplifier (such as a Maxim MAX4230 or similar low-offset op-amp) between the source and the AINx input. The MAX1202ACAP's analog input structure draws dynamic charge during acquisition, and source impedances above the datasheet maximum will cause gain errors and distortion. The internal 1.5 µs acquisition time is sufficient for source impedances up to approximately 5 kΩ at full 133 kSPS throughput.

규정 준수 정보

RoHS
Non Compliant
REACH
Compliant
AEC-Q100
Not Qualified
무연
No
무할로겐
Unknown
분쟁 광물
Compliant

MAX1202ACAP (no '+' suffix) is the legacy non-RoHS Maxim order code. The MAX1202ACAP+ variant adds RoHS/lead-free compliance. REACH substance compliance is confirmed via Maxim/Analog Devices material declarations. AEC-Q100 qualification is not applicable — this is a commercial/industrial-grade ADC. For RoHS-compliant RoHS-compliant ordering in new designs, use the MAX1202ACAP+ suffix.

데이터 검증일: 2026-10-14 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MAX1202ACAP MAX1202ACAP datasheet Maxim Integrated MAX1202ACAP 12-bit 8-channel SAR ADC 5V SSOP-20 133 kSPS serial 12-bit ADC MAX1202ACAP data acquisition system MAX1202ACAP vs MAX1202BCAP MAX1202ACAP drop-in replacement MAX1202ACAP+ RoHS price buy MAX1202 pinout SSOP-20 8-channel 12-bit ADC SPI MAX1202ACAP battery powered measurement

관련 부품 & 용어

Maxim Integrated Analog Devices MAX1202ACAP MAX1202ACAP+ MAX1202BCAP+ MAX1202BEAP+ SAR ADC successive approximation register analog-to-digital converter 12-bit resolution 8-channel multiplexer SPI interface track-and-hold amplifier SSOP-20 RoHS REACH internal voltage reference industrial process control data acquisition system portable measurement equipment
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기