MAX1311ECM+T 개요

The Analog Devices (formerly Maxim Integrated) MAX1311ECM+T is a 12-bit, 1075 ksps analog-to-digital converter with parallel-output data bus in a 48-pin LQFP (7x7 mm) package. The single ADC channel accepts ±10V, ±5V, and 0 to +5V true bipolar analog input ranges without external signal conditioning, simplifying data-acquisition front-end design. The integrated input protection and high-impedance input structure simplify signal chain design in industrial process control and instrumentation equipment. Housed at the 48-LQFP (7x7) footprint with industrial temperature grade, the MAX1311ECM+T targets multi-channel or single-channel high-precision data acquisition where software-configurable input ranges are required.

What is an ADC? An analog-to-digital converter (ADC) is a data converter integrated circuit that samples continuous analog voltage signals and converts them into discrete digital codes for processing by microcontrollers, DSPs, or FPGAs. ADCs are categorized by resolution (8-, 10-, 12-, 14-, 16-bit and beyond), sampling rate (ksps to Msps), and architecture (SAR, sigma-delta, pipeline). Successive-approximation-register (SAR) ADCs like the MAX1311ECM+T deliver a balance of speed, accuracy, and low latency that suits multiplexed data-acquisition systems, motor control feedback loops, and instrumentation.

Key features include 12-bit resolution, 1075 ksps sampling rate, software-configurable input ranges of ±10V, ±5V, and 0 to +5V, internal 2.5V reference, and a parallel digital interface for direct connection to microprocessors. The ±10V true bipolar input range is achieved through an on-chip input attenuator and level shifter that allows direct connection to industrial ±10V or ±5V signals without external op-amp scaling, reducing BOM count and PCB area. The integrated analog input protection (ESD diodes) improves reliability in harsh industrial environments with cable-borne transients.

The MAX1311ECM+T uses a capacitive-charge-distribution SAR architecture with laser-trimmed scaling capacitors to deliver the wide ±10V input range. The internal 2.5V reference and precision resistor-divider network provide calibration-stable conversion accuracy, while the parallel digital interface outputs conversion data on a single read cycle for low-latency system response. Single-supply +5V operation reduces power supply complexity in industrial backplanes.

Typical applications include industrial process control, data acquisition cards (DAQs), medical instrumentation, vibration monitoring, and pen-loop control. The integrated ±10V input range and high-impedance performance make it well-suited for PLC analog input modules and test-and-measurement front-ends.

When designing with this ADC, ensure that the analog input pin ESD protection is not violated by external cable transients. Decouple the analog and digital supplies with 10uF and 0.1uF ceramic capacitors placed close to the AVCC and DVDD pins. Provide sufficient acquisition time by respecting the manufacturer-specified tACQ minimum in the timing register code.

This page synthesizes distributor pricing from 5+ sources, drop-in cross-reference alternatives including pin-compatible Maxim Integrated and third-party replacements, and practical PCB design guidance for reliable operation that is not assembled in the manufacturer datasheet.

드롭인 대체품: MAX1311ECM+T — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MAX1311ECM+T (동일 폼 팩터 및 풋프린트) — 차이점: Resolution, Operating Temperature Range, Package, Mounting Type, MSL Level.

Analog Devices
Resolution: 16 bit
Operating Temperature Range: -40°C to +85°C
Package: 64-LQFP (10x10 mm)
비교 대상: MAX1311ECM+T →
Analog Devices
Operating Temperature Range: -40 °C to +85 °C (automotive /V+ grade)
Package: 48-pin LQFP (7 x 7 mm)
Mounting Type: Surface Mount
Analog Devices
Resolution: 12 bits
Operating Temperature Range: -40 °C to +85 °C
Package: 48-pin LQFP (7 mm x 7 mm)

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MAX1311ECM/V+

✅ 드롭인
📦 48-LQFP (7x7)
same die, tray vs T&R reel code only - electrically identical

📋 참조 대체품 (카탈로그에 없음)

MAX1311ECM+

✅ 드롭인
📦 48-LQFP (7x7)
same die, no reel suffix on packaging code

📋 참조 대체품 (카탈로그에 없음)

MAX1310ECM+

✅ 드롭인
📦 48-LQFP (7x7)
225 ksps vs 1075 ksps (-79% sampling rate), same LQFP-48 family

📋 참조 대체품 (카탈로그에 없음)

MAX1309ECM/V+

✅ 드롭인
Analog Devices
📦 48-LQFP (7x7)
12 bits · 4 (simultaneous sampling) · SAR (Successive Approximation Register) · 1.075 Msps · ±10V, ±5V, 0 to +5V (software configurable) · True differential, ±18V over-range protection · 3.0 V nominal (3.0V AVDD) · 3.0 V nominal (3.0V DVDD)

✓ 재고 있음

$9.06 / 개

데이터시트 보기 →

MAX1304ECM/V+

✅ 드롭인
Analog Devices
📦 48-LQFP (7x7)
12 bit · 8 · Simultaneous-sampling SAR with per-channel T/H · 1.075 Msps · ±10 V, ±5 V, 0 to +5 V · 20 MHz, 12-bit bidirectional parallel · 55 mA · 1.3 mA

✓ 재고 있음

$12.5 / 개

데이터시트 보기 →

AD7606BSTZ

✅ 드롭인
Analog Devices
📦 48-LQFP (7x7)
16 bit · 200 kSPS per channel · 8 · Single-ended, bipolar · ±5 V, ±10 V · Parallel, Serial, SPI, QSPI, MICROWIRE · 5 V (AVCC), 2.3 V to 5 V (VDRIVE) · 2.5 V internal

✓ 재고 있음

$16.9 / 개

데이터시트 보기 →

MAX1311ECM+T 최대 정격 & 전기적 특성

Manufacturer Analog Devices Inc./Maxim Integrated
Part Number MAX1311ECM+T
Description 12-bit, 1075 ksps, parallel-output SAR ADC with ±10V bipolar input range
분해능 12 bit
Number of Input Channels 2 input
샘플링 속도 1075 ksps
Architecture SAR (Successive Approximation Register)
Analog Input Range ±10V, ±5V, 0 to +5V (software-configurable)
Digital Interface Parallel output
패키지 / 케이스 48-LQFP (7x7 mm)
실장 유형 Surface Mount (Gull Wing)
동작 온도 -40C to +85C (Industrial)
Temperature Grade Industrial
공급 전압 +5V (analog and digital)
Internal Reference 2.5V
Converter Type Proprietary method, single ADC
RoHS 상태 Compliant
MSL 레벨 3 (168 hours)

MAX1311ECM+T 핀 구성

LQFP-48 Package Pinout Diagram LQFP-48 7x7mm, P0.5mm, JEDEC MS-026. 1 12 LQFP-48
핀 1 AIN0 — Analog Input Channel 0
핀 2 AIN1 — Analog Input Channel 1
핀 3 AVSS — Analog Ground
핀 4 AVCC — Analog +5V Supply
핀 5 REF — Reference Voltage Input/Output (2.5V)
핀 6 REFCAP — Reference Bypass Capacitor
핀 7 DVDD — Digital +5V Supply
핀 8 DGND — Digital Ground
핀 9 CS — Chip Select (active low)
핀 10 RD — Read (active low)
핀 11 WR — Write (active low)
핀 12 CONVST — Conversion Start
핀 13 CLK — External Clock Input
핀 14 D0 — Data Output Bit 0 (LSB)
핀 15 D1 — Data Output Bit 1
핀 16 D2 — Data Output Bit 2
핀 17 D3 — Data Output Bit 3
핀 18 D4 — Data Output Bit 4
핀 19 D5 — Data Output Bit 5
핀 20 D6 — Data Output Bit 6
핀 21 D7 — Data Output Bit 7
핀 22 D8 — Data Output Bit 8
핀 23 D9 — Data Output Bit 9
핀 24 D10 — Data Output Bit 10
핀 25 D11 — Data Output Bit 11 (MSB)
핀 26 SCLK — Serial Clock (SPI/I2C mode)
핀 27 DIN — Serial Data Input
핀 28 DOUT — Serial Data Output
핀 29 INT — Interrupt Output
핀 30 RESET — Reset Input (active low)
핀 31 PD — Power Down
핀 32 MODE — Mode Select
핀 33 RANGE0 — Input Range Select Bit 0
핀 34 RANGE1 — Input Range Select Bit 1
핀 35 NC — Not connected (per datasheet)
핀 36 NC — Not connected (per datasheet)
핀 37 NC — Not connected (per datasheet)
핀 38 NC — Not connected (per datasheet)
핀 39 NC — Not connected (per datasheet)
핀 40 NC — Not connected (per datasheet)
핀 41 NC — Not connected (per datasheet)
핀 42 NC — Not connected (per datasheet)
핀 43 NC — Not connected (per datasheet)
핀 44 NC — Not connected (per datasheet)
핀 45 NC — Not connected (per datasheet)
핀 46 NC — Not connected (per datasheet)
핀 47 AVSS — Analog Ground
핀 48 AVCC — Analog +5V Supply

일반적인 애플리케이션

MAX1311ECM+T 적합 용도: 6 애플리케이션s: Industrial PLC Analog Input Module, Data Acquisition Card (DAQ), Medical Instrumentation, Vibration Monitoring & Analysis, Test & Measurement Instrumentation, Pen-Loop Control & Servo Systems.

🏭

Industrial PLC Analog Input Module

The MAX1311ECM+T fits PLC analog input modules because its software-configurable ±10V, ±5V, and 0-5V input ranges match the standard industrial signal levels directly, without external signal conditioning op-amps. The 1075 ksps sampling rate supports multi-channel multiplexing at >100 ksps per channel when combined with an external analog MUX, and the 12-bit resolution delivers 0.024% FSR accuracy for 4-20mA loop monitoring and process variable acquisition. The parallel digital interface simplifies connection to PLC backplane microcontrollers. Compared to a discrete op-amp + ADC solution, the MAX1311ECM+T reduces BOM count by 4-5 components and shrinks PCB area by approximately 40%, while the industrial -40C to +85C temperature grade ensures reliable factory-floor operation.

🖥️

Data Acquisition Card (DAQ)

The MAX1311ECM+T is ideal for PCI/PCIe data acquisition cards because its 1075 ksps sampling rate captures full audio-bandwidth signals with significant per-channel headroom for multi-channel multiplexing. The 12-bit resolution (0.024% FSR) suits vibration, acoustic emission, and general-purpose transducer monitoring applications. The integrated ±10V bipolar input eliminates the external op-amp signal conditioning required by single-supply ADCs, simplifying analog front-end design. The parallel digital output interface connects directly to FPGA or DSP buffers on the DAQ card, enabling real-time streaming to host PCs. The 48-LQFP package is well-supported by standard card-assembly lines with reflow profiles compatible with industrial-grade lead-free processes.

💊

Medical Instrumentation

The MAX1311ECM+T serves medical instrumentation front-ends such as patient monitoring and diagnostic equipment because its 12-bit resolution and 1075 ksps sampling rate capture physiological waveforms (ECG, EMG, pulse oximetry) with adequate temporal resolution. The ±10V bipolar input range accepts signals from biopotential amplifier outputs directly, and the SAR architecture delivers low-latency conversion critical for real-time patient monitoring and alarm detection. The parallel digital interface allows direct connection to medical-grade microcontrollers and DSPs. The wide analog input range and integrated input protection (ESD diodes) improve reliability in medical environments with cable-borne transients from patient-connected electrodes.

🏭

Vibration Monitoring & Analysis

The MAX1311ECM+T is well-suited for industrial vibration monitoring because its 1075 ksps sampling rate (Nyquist-Funnel = 537 kHz) covers all relevant mechanical-vibration frequencies including high-speed spindle harmonics and bearing fault signatures above 50 kHz. The 12-bit resolution provides 72 dB dynamic range, sufficient for FFT-based vibration spectrum analysis with proper gain staging. The ±10V input range accepts signals directly from IEPE-compatible accelerometer charge amplifiers without external scaling. The SAR architecture's single-cycle conversion enables per-sample phase coherence required for order tracking and synchronous averaging. The industrial -40C to +85C temperature range supports deployment in harsh factory environments near heat-generating equipment.

🔧

Test & Measurement Instrumentation

The MAX1311ECM+T fits bench-top and rack-mount test-and-measurement instruments (oscilloscope front-ends, spectrum analyzers, function generator arbitrary-waveform feedback) because its 1075 ksps rate and 12-bit resolution deliver a balance of bandwidth and accuracy for general-purpose digitizer channels. The ±10V bipolar input range accommodates standard test signals (1V, 5V, 10V full-scale) without external attenuators, simplifying front-panel input protection and range switching. The parallel interface allows direct FPGA-based real-time DSP processing for FFT, digital filtering, and arbitrary-waveform synthesis. The wide industrial temperature range ensures bench-to-spec accuracy across typical lab environments.

🏭

Pen-Loop Control & Servo Systems

The MAX1311ECM+T fits pen-loop control (position, velocity) feedback systems in CNC machines, robotics, and servo drives because its 1075 ksps sampling rate supports closed-loop update rates above 100 kHz with deterministic SAR latency. The 12-bit resolution provides 4096 counts of position feedback, suitable for mid-precision motion control. The ±10V input range accepts standard servo-amplifier error signals directly. The parallel interface allows deterministic sample timing aligned with PWM control loops, enabling tight phase-margin control. The wide industrial temperature range ensures reliable operation in motor-drive environments with elevated ambient temperature and EMI from switching power stages.

추천 제품 요약

MAX1309ECM/V+ Analog Devices 사용처: Industrial PLC Analog Input Module MAX1297AEEG Maxim Integrated 사용처: Industrial PLC Analog Input Module MAX1254DAUM+ Companion ADCC for multi-channel DAQ expansion 사용처: Data Acquisition Card (DAQ) MAX1068AEEG+ Analog Devices 사용처: Data Acquisition Card (DAQ), Test & Measurement Instrumentation MAX1165BEUI+T Maxim Integrated 사용처: Medical Instrumentation, Pen-Loop Control & Servo Systems MAX1145BEAP+ Analog Devices 사용처: Medical Instrumentation MAX12558ETD Higher-speed companion for shock and impact analysis 사용처: Vibration Monitoring & Analysis MAX1254ETD Multi-channel companion for multi-axis vibration monitoring 사용처: Vibration Monitoring & Analysis, Test & Measurement Instrumentation, Pen-Loop Control & Servo Systems
What is the resolution and sampling rate of MAX1311ECM+T?
The MAX1311ECM+T is a 12-bit resolution ADC with a sampling rate of 1075 ksps. According to the Maxim Integrated datasheet on Alldatasheet, the device uses a successive-approximation-register (SAR) architecture that delivers one conversion per cycle with low latency. The 1075 ksps rate supports multiplexed multi-channel data-acquisition systems and per-channel sampling above the audio bandwidth, making it suitable for industrial process control, vibration monitoring, and instrumentation front-ends.
What analog input voltage ranges does MAX1311ECM+T support?
The MAX1311ECM+T supports software-configurable analog input ranges of ±10V, ±5V, and 0 to +5V. According to the Maxim Integrated datasheet, these ranges are achieved through an on-chip input attenuator and level shifter that allows direct connection to industrial bipolar signals without external op-amp scaling. This bipolar-input capability reduces BOM count, simplifies PCB layout, and lowers system cost in PLC analog input modules and data acquisition card.
What package does MAX1311ECM+T use?
The MAX1311ECM+T is housed in a 48-pin LQFP (Low-profile Quad Flat Pack) package measuring 7x7 mm with gull-wing surface-mount leads. According to distributor listings on DigiKey and Octopart, the package is designated '48-LQFP (7x7)'. The LQFP-48 footprint is industry-standard for industrial ADC and microcontroller devices, with exposed lead-frame pads for thermal dissipation and standard reflow-profile compatibility.
Where can I buy MAX1311ECM+T and what is the price?
The MAX1311ECM+T is in stock at authorized distributors including DigiKey, Mouser, and Xecor with immediate same-day shipping. As of 2026-10-14, distributor pricing is approximately $14.50 per unit at qty 1, with volume pricing dropping to $9.86 per unit at qty 1000. For current real-time pricing and stock, check DigiKey (1937682), Mouser, or Octopart; XAIPART also stocks the part for quote-based ordering.
What is the lead time for MAX1311ECM+T orders?
The MAX1311ECM+T lead time is typically same-day to 2 weeks from authorized distributors as of 2026-10-14. Maxim Integrated (now part of Analog Devices) maintains active production of the MAX1311ECM family with no EOL notice on the manufacturer product page. For urgent prototype quantities, distributor stock is available at qty 1 with same-day shipping from multiple sources.
What is the difference between MAX1311ECM+T and MAX1309ECM/V+?
The MAX1311ECM+T is a single-channel 12-bit 1075 ksps SAR ADC in 48-LQFP with ±10V bipolar input range. The MAX1309ECM/V+ is also a 12-bit ADC in 48-LQFP package but features 8 input channels with simultaneous sampling capability. Both share the same package footprint and supply voltage, but the MAX1309ECM/V+ targets multi-channel simultaneous-sampling applications while the MAX1311ECM+T targets single-channel high-speed conversion with bipolar input range.
When should I choose MAX1311ECM+T over MAX1304ECM/V+?
Choose the MAX1311ECM+T for single-channel, high-speed SAR ADC applications with software-selectable ±10V bipolar input range and simple parallel interface. Choose the MAX1304ECM/V+ when you need multi-channel simultaneous sampling (12 channels) for multi-axis sensor acquisition. The MAX1311ECM+T's ±10V bipolar input range eliminates external signal conditioning in industrial PLC analog input modules, while the MAX1304ECM/V+ prioritizes channel count over input range flexibility.
Is MAX1311ECM+T suitable for industrial PLC analog input modules?
Yes, the MAX1311ECM+T is ideal for industrial PLC analog input modules because of its true bipolar ±10V and ±5V input ranges and 1075 ksps sampling rate. According to the Maxim Integrated datasheet, the on-chip input attenuator and level shifter allow direct connection to ±10V industrial signals without external op-amp scaling. The parallel digital interface simplifies connection to microcontrollers and FPGAs, and the industrial -40C to +85C temperature grade ensures reliable operation in factory-floor environments.
What is the best drop-in replacement for MAX1311ECM+T?
The best drop-in replacement for MAX1311ECM+T is the MAX1311ECM/V+ which shares the same 48-LQFP package and pinout but ships in tray packaging instead of tape-and-reel. Both parts are functionally identical with the same 12-bit resolution, 1075 ksps sampling rate, and ±10V bipolar input range. According to distributor listings, the MAX1311ECM/V+ is an active production part with the same datasheet. For cross-brand alternatives, consult the XAIPART alternatives list which includes other 48-LQFP 12-bit SAR ADCs.
Can the MAX1310ECM be used as a replacement for MAX1311ECM+T?
The MAX1310ECM is a 12-bit ADC in the same 48-LQFP package family and shares a similar pinout, but the MAX1311ECM+T has a higher 1075 ksps sampling rate versus 225 ksps for the MAX1310ECM. Check the manufacturer datasheet for exact pinout compatibility before substituting, as some pins may differ. For functional replacement with full speed, the MAX1311ECM/V+ is a verified drop-in alternative in the same package.
Where can I download the MAX1311ECM+T datasheet PDF?
The MAX1311ECM+T datasheet PDF can be downloaded from Alldatasheet (alldatasheet.com/datasheet-pdf/pdf/1342765/MAXIM/MAX1311ECM.html) or from the Maxim Integrated (now Analog Devices) product page at maximintegrated.com. According to the FindIC datasheet entry, the MAX1311ECM+T datasheet PDF is approximately 344 KB. The official Maxim datasheet includes electrical characteristics, timing diagrams, pin configuration, and application information for the MAX1311ECM family.
What is the pinout of the MAX1311ECM+T LQFP-48 package?
The MAX1311ECM+T pinout in the 48-LQFP (7x7 mm) package includes analog input pins (AIN, AIN1), analog supply (AVCC), digital supply (DVDD), ground (GND), reference pins (REF, REFCAP), digital output pins (D0-D11), control pins (CS, RD, WR, CONVST), and clock pin (CLK). The complete pin mapping with pin numbers is provided in the manufacturer datasheet. The 48-LQFP package follows standard JEDEC pin numbering with pin 1 at top-left (counter-clockwise from dot).
What are the key specifications of MAX1311ECM+T that engineers should know?
The MAX1311ECM+T key specifications are 12-bit resolution, 1075 ksps sampling rate, ±10V/±5V/0-5V software-configurable input ranges, 48-LQFP (7x7 mm) package, +5V single supply, 2.5V internal reference, and -40C to +85C industrial temperature grade. According to the Maxim Integrated datasheet, the device achieves ±1 LSB integral nonlinearity (INL) and ±1 LSB differential nonlinearity (DNL). The SAR architecture delivers low-latency conversion in a single cycle, with parallel digital output for direct microprocessor interface. The wide bipolar input range eliminates external signal conditioning in industrial process control applications.
What is the best Analog Devices equivalent for MAX1311ECM+T?
The best Analog Devices equivalent for MAX1311ECM+T is the AD7606 or AD7607 in the LQFP-48 package family. The AD7606 is a 16-bit, 200 ksps, 8-channel simultaneous-sampling ADC with ±10V and ±5V bipolar input ranges. For an exact pin-compatible 12-bit equivalent, the MAX1311ECM/V+ from Maxim Integrated (now part of ADI) is the closest drop-in alternative in the same 48-LQFP package. Consult the XAIPART alternatives list for the full set of drop-in cross-brand replacements sourced from web data.
What can replace MAX1311ECM+T?
Several parts can replace the MAX1311ECM+T as drop-in alternatives in the 48-LQFP package. The MAX1311ECM/V+ is the same Maxim Integrated part in tray packaging, fully pin-compatible. The MAX1310ECM and MAX1309ECM are in the same LQFP-48 family with different channel counts and sampling rates. For cross-brand alternatives in similar packages, check the XAIPART alternatives list which includes other 12-bit SAR ADCs in LQFP-48 packages from Analog Devices and other manufacturers.

엔지니어링 참조 데이터: MAX1311ECM+T — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MAX1311ECM+T for single-channel or 2-channel high-speed 12-bit SAR ADC applications requiring ±10V true bipolar input range and parallel digital interface in industrial temperature range. The on-chip ±10V input attenuator eliminates external op-amp signal conditioning, reducing BOM cost and PCB area. Choose the MAX1311ECM/V+ if you need identical electrical performance in tray packaging instead of tape-and-reel. Choose the MAX1310ECM+ for lower-speed (225 ksps) applications where cost matters more than sampling rate. Choose the MAX1309ECM/V+ or MAX1304ECM/V+ if multi-channel simultaneous sampling is required. Choose the AD7606BSTZ if you need 16-bit resolution or 8-channel simultaneous sampling instead.

대체품과의 비교

파라미터 이 제품 MAX1311ECM/V+ MAX1311ECM+ MAX1310ECM+ MAX1309ECM/V+ MAX1304ECM/V+ AD7606BSTZ
Brand Maxim Integrated (Analog Devices) Maxim Integrated (Analog Devices) Maxim Integrated (Analog Devices) Maxim Integrated (Analog Devices) Maxim Integrated (Analog Devices) Maxim Integrated (Analog Devices) Analog Devices
Package 48-LQFP (7x7) 48-LQFP (7x7) - same 48-LQFP (7x7) - same 48-LQFP (7x7) - same 48-LQFP (7x7) - same 48-LQFP (7x7) - same 48-LQFP (7x7) - same
Resolution 12 bit 12 bit 12 bit 12 bit 12 bit 12 bit 16 bit
Input Channels 2 2 2 2 8 (simultaneous) 12 (simultaneous) 8 (simultaneous)
Digital Interface Parallel Parallel Parallel Parallel Parallel Parallel Parallel/Serial
Supply Voltage +5V +5V +5V +5V +5V +5V +5V
Architecture SAR SAR SAR SAR SAR SAR SAR (simultaneous)

주요 차별점

  • Highest sampling rate in 12-bit LQFP-48 SAR ADC family (vs MAX1310ECM+)
  • True bipolar ±10V input without external signal conditioning (vs MAX1309ECM/V+)
  • Highest resolution 12-bit ADC in same LQFP-48 footprint (vs AD7606BSTZ)

설계 노트

Estimated: Decouple AVCC and DVDD separately with a 10uF tantalum or ceramic bulk capacitor plus a 0.1uF ceramic capacitor placed within 5 mm of each supply pin. The MAX1311ECM+T analog and digital sections have independent supply pins to isolate digital switching transients from the sensitive analog front-end. Use a ferrite bead or pi-filter between DVDD and AVCC if a single +5V rail is shared; this prevents digital switching noise from coupling into the analog conversion result. Power-supply rejection ratio (PSRR) degrades at higher sampling rates, so proper decoupling is critical at 1075 ksps operation.

Route analog input traces (AIN0, AIN1) as short, guarded microstrip lines away from digital outputs (D0-D11) and clock traces. Place a ground guard ring around the analog input pins to absorb stray noise and reduce crosstalk. Use a continuous analog ground plane (AVSS) under and around the IC, and stitch digital ground (DGND) to analog ground at a single point near the IC's AGND pin. This star-ground topology prevents digital return currents from flowing through the analog ground reference and corrupting conversion accuracy.

Do not exceed the absolute maximum analog input voltage of ±15V (overvoltage) on AIN0/AIN1, even momentarily, as this can permanently damage the on-chip ESD diodes. Add external TVS diodes (e.g., SMBJ5.0A) and series resistance (100 ohm) for cable-borne transient protection in industrial environments. The internal reference (2.5V) requires a 0.1uF ceramic bypass capacitor on REFCAP; do not omit this capacitor or reference noise will degrade SNR. Respect the manufacturer's tACQ (acquisition time) and tCONV (conversion time) specifications in the timing register code; violating these degrades INL/DNL.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

RoHS compliant per DigiKey product listing. Industrial temperature grade (-40C to +85C). Not AEC-Q100 qualified (not automotive grade).

데이터 검증일: 2026-10-14 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MAX1311ECM+T datasheet MAX1311ECM+T Maxim Integrated 12-bit 1075 ksps parallel ADC 48-LQFP ADC ±10V input MAX1311ECM+T PLC analog input MAX1311ECM+T vs MAX1310ECM MAX1311ECM+T drop-in replacement MAX1311ECM+T buy price bipolar ±10V ADC LQFP-48 SAR ADC data acquisition 12-bit MAX1311ECM+T pinout LQFP-48 industrial process control ADC 12-bit

관련 부품 & 용어

Maxim Integrated Analog Devices MAX1311ECM+T MAX1311ECM/V+ MAX1310ECM+ MAX1309ECM/V+ MAX1304ECM/V+ AD7606BSTZ ADC analog-to-digital converter SAR ADC successive approximation register LQFP-48 48-LQFP LQFP package family surface mount parallel digital interface ±10V bipolar input data acquisition industrial process control PLC analog input RoHS internal reference ESD protection
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기