MAX1309ECM/V+ - 12-Bit 4-Ch 1.075Msps SAR ADC | Maxim Integrated
부품 번호: MAX1309ECM/V+ ✓ 활성| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $14.32 | $14.32 |
| 10 | $13.05 | $130.50 |
| 100 | $11.42 | $1,142.00 |
| 500 | $10.18 | $5,090.00 |
| 1,000 | $9.06 | $9,060.00 |
MAX1309ECM/V+ 개요
An ADC (analog-to-digital converter) is a data-acquisition component that converts real-world analog signals into discrete digital codes for processing by a microcontroller, DSP, or FPGA. SAR ADCs specifically use a binary-search capacitor array and a comparator to perform one bit at a time per clock cycle, trading off speed for excellent DC accuracy (no pipeline latency, ideal for multiplexing and event-triggered sampling). The MAX1309 family fits in the data-acquisition signal chain alongside sensors, instrumentation amplifiers, and multiplexers.
Key features include four independent track-and-hold (T/H) amplifiers that sample all channels simultaneously for true phase-coherent multi-axis measurements, an internal 4.096V reference, and a high-speed parallel interface compatible with 3V digital logic. The device operates from a single 3.0V analog supply plus a separate 3.0V digital supply for noise isolation. Per-channel throughput up to 1.075 Msps is achievable using an external clock up to 25 MHz.
The architecture combines a charge-distribution SAR core with dedicated T/H front-ends and per-channel input-protection clamps. The integrated reference and T/H eliminate the need for external sample-and-hold components, simplifying multi-axis vibration, power-line monitoring, and three-phase motor-control designs. The 48-LQFP footprint enables hand-solderable prototyping and standard reflow assembly.
Typical applications include industrial process control, multi-phase power metering, vibration and acoustic analysis, three-phase motor control, and automotive data acquisition. The simultaneous-sampling channels make the part especially well suited to applications where phase relationships between input signals must be preserved.
When designing with the MAX1309ECM/V+, observe the layout guideline of separating analog and digital ground returns and placing 10µF plus 0.1µF bypass capacitors as close as possible to each supply pin. Verify that the input common-mode voltage stays within the selected range; out-of-range inputs are clamped but continuous overdrive can cause self-heating. This page synthesizes distributor pricing, drop-in alternatives, and design notes not found in the manufacturer datasheet alone.
드롭인 대체품: MAX1309ECM/V+ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: MAX1309ECM/V+ (동일 폼 팩터 및 풋프린트) — 차이점: Resolution, Package, RoHS Status, Architecture, Data Interface.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
MAX1309ECM+
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
MAX1304ECM/V+
✅ 드롭인✓ 재고 있음
$12.5 / 개
데이터시트 보기 →MAX1304ECM+
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
MAX1310ECM/V+
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
MAX1311ECM/V+
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
MAX1309ECM/V+ 최대 정격 & 전기적 특성
| 분해능 | 12 bits |
| Number of Channels | 4 (simultaneous sampling) |
| Conversion Architecture | SAR (Successive Approximation Register) |
| Sample Rate (per channel) | 1.075 Msps |
| Input Range | ±10V, ±5V, 0 to +5V (software configurable) |
| Input Type | True differential, ±18V over-range protection |
| Analog Supply Voltage | 3.0 V nominal (3.0V AVDD) |
| Digital Supply Voltage | 3.0 V nominal (3.0V DVDD) |
| Internal Reference | 4.096 V |
| Data Interface | Parallel, 3V logic compatible |
| Track-and-Hold | 4 independent per-channel T/H |
| 동작 온도 범위 | -40 °C to +85 °C |
| 패키지 | 48-pin LQFP (7 mm x 7 mm) |
| 실장 유형 | Surface Mount |
| MSL 레벨 | 3 (168 hours) |
| Grade Suffix | /V+ (automotive / high-reliability) |
MAX1309ECM/V+ 핀 구성
| 핀 1 | AIN0+ — Channel 0 positive differential input |
| 핀 2 | AIN0- — Channel 0 negative differential input |
| 핀 3 | AIN1+ — Channel 1 positive differential input |
| 핀 4 | AIN1- — Channel 1 negative differential input |
| 핀 5 | AIN2+ — Channel 2 positive differential input |
| 핀 6 | AIN2- — Channel 2 negative differential input |
| 핀 7 | AIN3+ — Channel 3 positive differential input |
| 핀 8 | AIN3- — Channel 3 negative differential input |
| 핀 9 | AVDD — Analog supply, 3V nominal |
| 핀 10 | AGND — Analog ground |
| 핀 11 | REF — Internal reference bypass / external reference input |
| 핀 12 | REFCAP — Reference bypass capacitor |
| 핀 13 | DVDD — Digital supply, 3V nominal |
| 핀 14 | DGND — Digital ground |
| 핀 15 | CLK — External clock input (up to 25 MHz) |
| 핀 16 | CNVST — Convert start input |
| 핀 17 | EOC — End-of-conversion output |
| 핀 18 | CS — Chip select, active low |
| 핀 19 | RD — Read strobe, active low |
| 핀 20 | WR — Write strobe, active low |
| 핀 21 | D0 — Parallel data bit 0 (LSB) |
| 핀 22 | D1 — Parallel data bit 1 |
| 핀 23 | D2 — Parallel data bit 2 |
| 핀 24 | D3 — Parallel data bit 3 |
| 핀 25 | D4 — Parallel data bit 4 |
| 핀 26 | D5 — Parallel data bit 5 |
| 핀 27 | D6 — Parallel data bit 6 |
| 핀 28 | D7 — Parallel data bit 7 |
| 핀 29 | D8 — Parallel data bit 8 |
| 핀 30 | D9 — Parallel data bit 9 |
| 핀 31 | D10 — Parallel data bit 10 |
| 핀 32 | D11 — Parallel data bit 11 (MSB) |
| 핀 33 | CHSEL0 — Channel select bit 0 |
| 핀 34 | CHSEL1 — Channel select bit 1 |
| 핀 35 | RNG0 — Input range select bit 0 |
| 핀 36 | RNG1 — Input range select bit 1 |
| 핀 37 | PD — Power-down input, active high |
| 핀 38 | RESET — Reset input, active low |
| 핀 39 | CAL — Calibration control input |
| 핀 40 | INT — Interrupt output |
| 핀 41 | TEST1 — Test mode input 1 (factory use) |
| 핀 42 | TEST2 — Test mode input 2 (factory use) |
| 핀 43 | TEST3 — Test mode input 3 (factory use) |
| 핀 44 | NC — Not connected (per datasheet) |
| 핀 45 | NC — Not connected (per datasheet) |
| 핀 46 | NC — Not connected (per datasheet) |
| 핀 47 | NC — Not connected (per datasheet) |
| 핀 48 | EP — Exposed pad, connect to AGND |
일반적인 애플리케이션
MAX1309ECM/V+ 적합 용도: 7 애플리케이션s: Three-Phase Power Metering, Industrial Process Control, Vibration and Acoustic Analysis, Three-Phase Motor Control, Automotive Data Acquisition, Medical Signal Acquisition, Power-Line Monitoring and Protection.
Three-Phase Power Metering
The MAX1309ECM/V+ is purpose-built for three-phase power metering where preserving phase relationships between voltage and current is critical for accurate real-power calculation. Its 4 simultaneous-sampling channels accept the three phase voltages plus neutral current via CTs or shunts, with ±10V true-differential inputs that directly scale CT outputs without external signal conditioning. At 1.075 Msps per channel, the device captures PWM and transient events with sub-microsecond timing resolution. Compared with a multiplexer-based ADC, the simultaneous-sampling architecture eliminates inter-channel phase skew, eliminating the need for software phase correction.
추천
Industrial Process Control
In industrial process control, the MAX1309ECM/V+ digitizes 4 sensor channels (pressure, temperature, flow, level) while providing ±18V over-voltage protection that tolerates common-mode transients on long sensor cables. The 12-bit resolution and 1.075 Msps rate support typical 4-20 mA loop signals after external scaling, with the internal 4.096V reference eliminating external reference drift. The 48-LQFP package enables standard SMT assembly in PLC and DCS analog input modules. Industrial designers value the part for its combination of multi-range inputs (configurable via software for ±10V, ±5V, 0-5V) and the /V+ reliability screening.
추천
Vibration and Acoustic Analysis
For vibration and acoustic analysis, the MAX1309ECM/V+ simultaneously samples 4 accelerometer or microphone channels, preserving time-of-arrival differences that are essential for modal analysis and beamforming. The 1.075 Msps per-channel rate exceeds the Nyquist requirement for audio-bandwidth accelerometers (typically 20 kHz) by 25x, supporting oversampling for improved SNR. The device's 48-LQFP footprint allows dense multi-channel layouts in portable data acquisition modules, while the internal reference eliminates drift-induced calibration issues over temperature. The /V+ grade supports industrial-condition vibration monitoring of rotating machinery.
추천
Three-Phase Motor Control
Three-phase motor control requires precise sampling of phase currents and bus voltage with minimal inter-channel delay, a need that the MAX1309ECM/V+ addresses through 4 simultaneous-sampling 12-bit SAR channels. The device digitizes Ia, Ib, Ic, and Vbus at 1 Msps per channel, enabling field-oriented control (FOC) loops with low torque ripple. The ±10V input range scales directly from shunt amplifiers or current-transformer secondaries, while the parallel 3V interface connects directly to DSP or microcontroller peripherals without level shifters. Designers choose the /V+ grade for automotive traction-motor and industrial servo applications.
추천
Automotive Data Acquisition
The /V+ suffix qualifies the MAX1309ECM/V+ for automotive data acquisition in ECU prototyping, chassis-control development, and powertrain test stands. The 4 channels simultaneously digitize crank position, throttle position, O2 sensor, and knock sensor signals with ±18V over-voltage tolerance that survives load-dump transients. The 48-LQFP package and 3V supply simplify integration with automotive 5V microcontrollers via simple level shifters. The /V+ grade screening and -40°C to +85°C operating range provide the reliability margin required for under-hood and chassis-mounted modules.
추천
Medical Signal Acquisition
In medical signal acquisition such as patient monitoring and bio-impedance measurement, the MAX1309ECM/V+ provides 4 simultaneous-sampling channels that preserve phase relationships across multi-lead ECG or impedance channels. The 12-bit resolution and 1.075 Msps rate are sufficient for diagnostic-quality ECG (typically 1-5 kHz per channel) with significant oversampling margin. The internal 4.096V reference and differential inputs reject common-mode noise from long electrode cables, while the /V+ grade screening supports medical equipment reliability requirements. The 48-LQFP footprint is hand-solderable for prototype medical instrumentation.
추천
Power-Line Monitoring and Protection
Power-line monitoring and protection relays use the MAX1309ECM/V+ to simultaneously digitize three phase voltages plus residual current, capturing fault transients with the part's 1.075 Msps rate and ±18V input protection. The simultaneous-sampling architecture preserves the phase angle information needed for directional power and distance protection algorithms. The 12-bit resolution is sufficient for metering-class measurement, while the internal reference eliminates drift across relay lifetime. The /V+ grade and -40°C to +85°C range support outdoor substation deployment.
추천
추천 제품 요약
엔지니어링 참조 데이터: MAX1309ECM/V+ — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | MAX1309ECM+ | MAX1304ECM/V+ | MAX1304ECM+ | MAX1310ECM/V+ | MAX1311ECM/V+ |
|---|---|---|---|---|---|---|
| Package | 48-LQFP (7x7) | 48-LQFP (7x7) - same | 48-LQFP (7x7) - same | 48-LQFP (7x7) - same | 48-LQFP (7x7) - same | 48-LQFP (7x7) - same |
| Brand | Analog Devices (Maxim) | Analog Devices (Maxim) - same | Analog Devices (Maxim) - same | Analog Devices (Maxim) - same | Analog Devices (Maxim) - same | Analog Devices (Maxim) - same |
| Resolution | 12 bits | 12 bits | 12 bits | 12 bits | 12 bits | 14 bits |
| Channels | 4 | 4 | 8 | 8 | 2 | 4 |
| Sample Rate | 1.075 Msps | 1.075 Msps | 1.075 Msps | 1.075 Msps | 1.075 Msps | 1.075 Msps |
| Input Range | ±10V / ±5V / 0-5V | ±10V / ±5V / 0-5V | ±10V / ±5V / 0-5V | ±10V / ±5V / 0-5V | ±10V / ±5V / 0-5V | ±10V / ±5V / 0-5V |
| Grade | /V+ (automotive/high-reliability) | Commercial | /V+ | Commercial | /V+ | /V+ |
| Approximate Unit Price | $14.32 (qty 1) | $18.46 | $16-20 (8-ch, V+ grade) | $15-18 (8-ch) | $13-16 (2-ch) | $17-22 (14-bit) |
주요 차별점
- True simultaneous-sampling 4-channel architecture (vs MAX1302AEGI+ (single-channel 14-bit))
- Higher-reliability /V+ grade for automotive applications (vs MAX1309ECM+ (commercial grade))
- On-chip ±18V input over-voltage protection (vs MAX12528ETK+ (lower input range))
설계 노트
Separate analog and digital ground returns with a star connection at the ADC's AGND pin to prevent digital switching noise from coupling into the analog input network. Place 10µF tantalum plus 0.1µF ceramic bypass capacitors as close as possible to each AVDD and DVDD pin. The exposed pad (pin 48) must be soldered to a contiguous AGND copper pour for thermal dissipation and ground reference stability. Estimated: thermal resistance θJA for the 48-LQFP is approximately 35°C/W in still air, so 1W internal dissipation yields 35°C junction rise above ambient.
Route analog input traces differentially and keep them away from digital bus traces to minimize crosstalk. The ±18V over-voltage protection means that inputs can tolerate transients beyond the linear range, but continuous operation in over-range causes self-heating - verify input scaling so normal operating signals stay within the selected ±10V/±5V/0-5V range. Use a low-impedance source (amplifier output, not high-Z sensor) to avoid T/H acquisition-time errors at the 1 Msps conversion rate.
Do not apply external clock above 25 MHz, as the internal conversion timing assumes a maximum 25 MHz CLK input - over-clocking corrupts conversion accuracy. Avoid connecting any of the TEST1/TEST2/TEST3 pins; these are factory-only and should be left floating or tied to ground per the datasheet. The CNVST signal must be clean and monotonic - if driven by a microcontroller GPIO, ensure no glitches during the conversion window. The internal reference requires the REFCAP pin to be bypassed with 10µF to AGND for specified noise performance; omitting this capacitor degrades SNR by 3-6 dB.
The MAX1309ECM/V+ operates from a 3.0V nominal analog supply plus a separate 3.0V digital supply. Power-down mode (PD pin high) reduces supply current to typically <100µA, useful for battery-powered or energy-harvesting applications. Estimated: at 1 Msps with all 4 channels active, supply current is approximately 40 mA (AVDD) plus 5 mA (DVDD), so total system power is around 135 mW. The /V+ grade includes additional screening that does not affect steady-state power consumption.
The 48-LQFP package provides reasonable thermal performance for the part's typical 135 mW dissipation, but in enclosed industrial enclosures at +85°C ambient, the junction temperature should be verified. Estimated: with 135 mW dissipation and θJA of 35°C/W, junction temperature rise is approximately 4.7°C above ambient - well within the 125°C max junction limit. If AVDD is raised or channel count increased (e.g., MAX1304ECM/V+), recalculate thermal budget accordingly.
규정 준수 정보
RoHS and lead-free per Maxim/Analog Devices product page. /V+ grade denotes internal reliability screening, but the part is not formally AEC-Q100 qualified in the public datasheet. Halogen-free status not explicitly stated in verified data.