MAX388EPN+ - 8:1 3kOhm Analog Multiplexer | Analog Devices
부품 번호: MAX388EPN+ ✗ 단종MAX388EPN+ 개요
An analog multiplexer is an interface IC that routes one of several analog inputs to a shared output. The MAX388 family combines an 8:1 single-ended multiplexer with internal selection latches, placing it in the interface IC hierarchy alongside analog switches, mux/demux devices and signal-routing components. This makes the device useful when several sensor, measurement, or control signals must share a limited number of converter inputs.
Key features include an 8:1 multiplexing ratio, 3 kOhm on-resistance and a high-voltage fault-protected architecture. The internal latches remove the need to hold a control input in a defined state after selection. The product family also provides an off behavior when power is removed but input voltages remain applied, allowing all channels to turn off and limiting unintended signal paths. The MAX388EPN+ is specifically listed in an 18-pin PDIP package.
The MAX388 family uses a high-voltage series N-channel, P-channel, N-channel structure rather than a conventional single-polarity switch arrangement. This topology is specifically intended to improve fault protection in systems where external inputs can exceed the supply voltage or where power can be removed before the analog signals. The 3 kOhm on-resistance is appropriate for medium-impedance sensor and instrumentation paths, although system gain, leakage and settling requirements must be evaluated in the complete signal chain.
Typical uses include multi-sensor signal selection, instrumentation measurement multiplexing, industrial control signal routing, test-equipment input selection and embedded analog measurement systems. The latched channel selection is especially useful when a host controller writes a channel address and then performs an analog conversion. In these systems, the mux reduces the number of analog input channels required at the converter while preserving a defined route through the selected switch.
Designers should confirm the absolute maximum input and supply ratings, channel leakage, off isolation, on-state resistance tolerance and acquisition settling time in the manufacturer datasheet before finalizing signal paths. Input and ground connections should be arranged to minimize coupling between adjacent channels, and unused digital control inputs should be driven to valid logic levels. Because the MAX388 family is obsolete, long-life programs should verify availability, alternate sourcing and any required qualification before release to production.
This product page consolidates the confirmed switch ratio, on-resistance, package, fault-protection architecture and lifecycle information with practical design guidance. It also identifies the limited number of verified drop-in alternatives, helping engineers distinguish a true pin-compatible replacement from a broader functional equivalent before modifying an existing 18-pin PCB layout.
드롭인 대체품: MAX388EPN+ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
MAX388CPN+
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
MAX388EPN
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
MAX388EPN+ 사양
| Product Type | 8-channel single-ended analog multiplexer |
| Multiplexer Configuration | 8:1 |
| Number of Circuits | 1 circuit |
| On-Resistance | 3 kOhm |
| 패키지 | 18-pin PDIP |
| Switch Architecture | High-voltage series N-channel, P-channel, N-channel |
| Selection Control | Internal data latches |
| Fault Protection | High-voltage fault-protected channels |
| Power-Off Behavior | All channels turn off when input voltages remain applied |
| Product Lifecycle | Obsolete |
| 실장 유형 | Through-hole |
| Channel Count | 8 channels |
| Single-Ended Multiplexing | Supported |
MAX388EPN+ 18-pin pdip 핀 구성 가이드
MAX388EPN+(18-pin pdip 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: MAX388EPN+.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
MAX388EPN+ 적합 용도: 6 애플리케이션s: Multi-Sensor Measurement, Industrial Control Signal Routing, Test and Measurement Systems, Instrumentation Signal Conditioning, Embedded Analog Monitoring, Diagnostic Signal Selection.
Multi-Sensor Measurement
The MAX388EPN+ fits a multi-sensor measurement front end by selecting one of eight single-ended inputs and presenting it to a shared analog measurement channel. Its 8:1 organization reduces the number of converter inputs needed when monitoring temperature, pressure, position or level transducers. The 3 kOhm on-resistance is suitable for many medium-impedance sensor paths, while the internal latches let a controller issue an address and retain the selected route during conversion. Designers should verify leakage and settling requirements for the highest-impedance sensor and maintain the device within its specified supply and input limits.
추천
Industrial Control Signal Routing
The MAX388EPN+ can route multiple control or feedback signals through one shared analog input in an industrial controller. Eight latched single-ended channels provide deterministic address selection, and the 3 kOhm on-resistance is appropriate for many low-frequency control paths. The high-voltage fault-protected architecture is particularly relevant when an external signal source may remain energized while the controller supply is removed. Engineers should confirm the absolute maximum input voltage, off-state behavior and grounding arrangement for each analog source, and use the manufacturer pin table to implement address and latch controls correctly.
추천
Test and Measurement Systems
A MAX388EPN+ can provide input selection in test and measurement equipment that must connect several analog sources to one measurement chain. Eight single-ended inputs, a 3 kOhm on-resistance and latched control support repeatable source routing under software control. This arrangement helps limit converter count while preserving a defined path for calibration, diagnostic and DUT signals. Because the MAX388 family is obsolete, instrument designers should confirm channel leakage, isolation, settling time and switching transients against their accuracy budget, then plan the MAX388CPN+ as a potential same-package migration path.
추천
Instrumentation Signal Conditioning
The MAX388EPN+ is applicable between multiple instrumentation outputs and a shared analog-processing front end. Its eight single-ended channels allow a system to select thermocouple, bridge, potentiometer or other slow-moving analog signals without providing a dedicated converter input for every channel. The latched selection reduces control complexity, and 3 kOhm on-resistance can support common medium-impedance sensor networks. Signal integrity depends on keeping input traces short, providing a stable reference and observing the multiplexer leakage and acquisition settling requirements in the manufacturer datasheet, particularly when source impedance is high.
추천
Embedded Analog Monitoring
The MAX388EPN+ can reduce analog input count in an embedded monitoring system by selecting one of eight external conditions for a common ADC channel. Its internal data latches support a simple address-and-latch control sequence, while the 3 kOhm on-resistance accommodates many sensor and divider networks. The device is especially relevant to legacy systems designed around the MAX388 family, but engineers should not introduce it into a new design without considering the obsolete lifecycle and a verified migration path. Check the complete datasheet for input thresholds, timing and fault conditions before final firmware and board decisions.
추천
Diagnostic Signal Selection
The MAX388EPN+ supports diagnostic systems that must compare or monitor several analog fault or status signals through one shared acquisition path. Eight latched channels can be scanned under controller supervision, and the fault-protected high-voltage architecture is advantageous when a monitored signal can outlive the logic supply. The 3 kOhm on-resistance supports many conventional monitoring circuits, but engineers must validate off-state behavior, leakage and absolute maximum inputs for the specific fault environment. The complete pin and electrical tables should accompany any redesign because legacy package variants can differ in control implementation.
추천
추천 제품 요약
엔지니어링 참조 데이터: MAX388EPN+ — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | MAX388CPN+ | MAX388EPN |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 18-pin PDIP | 18-pin PDIP | 18-pin PDIP |
| Multiplexer Configuration | 8:1 | 8:1 | 8:1 |
| Channel Count | 8 single-ended channels | 8 single-ended channels | 8 single-ended channels |
| On-Resistance | 3 kOhm | 3 kOhm | 3 kOhm |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit |
| Selection Control | Internal data latches | Internal data latches | Internal data latches |
| Fault Protection | High-voltage fault-protected architecture | Fault-protected MAX388 family operation | High-voltage fault-protected architecture |
| Mounting Type | Through-hole | Through-hole | Through-hole |
주요 차별점
- Confirmed complete same-package replacement path (vs MAX388CPN+)
- Exact MAX388EPN+ ordering-code availability for legacy repair (vs MAX388EPN)
- Fault-protected power-off channel behavior (vs MAX388CPN+)
설계 노트
Treat the power-off fault behavior as a system-level constraint, not merely a switching convenience. The MAX388 family is designed to turn all channels off when power is removed while input voltages remain present, but external clamp networks, source impedance and downstream protection still determine the actual fault energy. Review the absolute maximum input ratings, supply sequence and system power-down states in the manufacturer datasheet before connecting field-wired or externally powered signals.
Route the eight analog inputs as short, quiet traces and connect the multiplexer ground pins directly to the measurement-system ground plane. Place the device near the shared analog output to limit trace resistance, capacitance and susceptibility to adjacent digital switching. Keep address and latch routing away from sensitive input nets, and use a stable analog reference and suitable input conditioning. Verify acquisition settling against the highest source impedance used in the design.
Calculate the analog error budget with the multiplexer's 3 kOhm on-resistance and the source impedance rather than treating 3 kOhm as negligible. For a source near 100 kOhm, the switch resistance introduces a substantial divider with the input resistance of the following amplifier or converter. Include leakage from the other seven channels when working with high-impedance sensors, and allow sufficient acquisition time after changing the latched address before taking the measurement.
Maintain the 18-pin PDIP footprint exactly when substituting a drop-in candidate. Confirm each package pin against the manufacturer pin-description table rather than relying only on the DIP outline, because the MAX388 family's address, latch, enable and analog pins must correspond correctly. For legacy repair work, inspect socket contacts, board contamination and bent pins; a mechanically similar package cannot compensate for an incorrect control-net assignment or incompatible maximum rating.
Establish the supply, enable and analog-input sequencing before power is applied. Because the device is designed for fault protection when inputs remain energized after power removal, the system must not assume that every internal transistor remains off under every possible ramp condition. Use controlled power sequencing where required, observe the absolute maximum ratings, and place the device within a lifecycle plan that accounts for its obsolete status and the sourcing of a qualified replacement.
규정 준수 정보
The MAX388 product page identifies the family as obsolete. RoHS, REACH, lead-free, halogen-free and conflict-minerals status are not confirmed for this exact ordering code.