NXP Semiconductors

MPVZ5004GW7U - 3.92kPa Pressure Sensor, 5V, SOP-8 | NXP

부품 번호: MPVZ5004GW7U ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
1.0 V to 4.9 V (at 5 V excitation) Vdss 4 mA typ (per datasheet family) Id 8-DIP Module (Case 1560-02) Package
시작가 $6.75 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $11.5 $11.50
10 $10.3 $103.00
100 $8.95 $895.00
500 $7.6 $3,800.00
1,000 $6.75 $6,750.00
ℹ️ 모든 가격은 USD 기준입니다

MPVZ5004GW7U 개요

The NXP MPVZ5004GW7U is a monolithic silicon piezoresistive pressure sensor housed in an 8-pin DIP/SOP module that delivers a conditioned analog output of approximately 1 V to 4.9 V over a 0 to 3.92 kPa (0.57 psi) vented gauge pressure range. The device integrates on-chip signal conditioning, temperature compensation, and calibration, producing a ratiometric output proportional to 5 V excitation. The transducer uses advanced micromachining with thin-film metallization and bipolar processing to combine a high-sensitivity implanted strain gauge with low-drift signal-chain components.

A pressure sensor (also called a pressure transducer) is a device that converts an applied pressure into an analog electrical signal, typically voltage. Piezoresistive sensors rely on strain gauges whose resistance changes with mechanical deformation of a silicon diaphragm. Within the sensor hierarchy, MPVZ5004GW7U sits inside the MEMS (micro-electromechanical systems) family, which itself is a subset of sensors and transducers. These conditioned parts include amplifier, temperature-compensation, and calibration stages on-die, so they connect directly to a microcontroller ADC without external analog front-end components.

Key features include a full-scale span of 3.92 kPa, an output span of approximately 4.0 V (from 1 V at 0 kPa to 4.9 V at 3.92 kPa, assuming 5 V excitation), ratiometric output that tracks supply voltage, and an operating temperature range of 0 °C to 85 °C (per the device family datasheet). The 5.59 mm male tube port accepts a flexible hose and gives the part its "GW" (gauge, with port) package designation, distinguishing it from surface-mount leadless siblings.

The transducer architecture uses a single-crystal silicon diaphragm with an implanted piezoresistive Wheatstone bridge. A first-stage differential amplifier and temperature-correction network run on the same die, producing a calibrated transfer function near VOUT = 5 V × (0.2 + P / 4.0 kPa) over the compensated band. Compared with ceramic-capacitive or discrete strain-gauge designs, this integration reduces calibration effort at end-of-line and improves long-term drift.

Typical applications include medical respiratory airflow measurement (CPAP flow sensing), HVAC variable-air-volume (VAV) boxes, weather stations, altimeters, and process-control manifolds. The vented gauge reference simplifies absolute-pressure correction in patient monitoring. Designers should account for the gauge-port orientation and ensure the hose connection is leak-tight; see the manufacturer datasheet for derating curves above 85 °C and recommended PCB footprint when hand-soldering.

드롭인 대체품: MPVZ5004GW7U — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPVZ5004GW7U (동일 폼 팩터 및 풋프린트) — 차이점: Package, Supply Voltage, Operating Temperature, Sensitivity, Output Type.

NXP Semiconductors
Package: 8-SMD Module
Supply Voltage: 5 V typical (5 V max)
Operating Temperature: 0C to +85C (per Partstack)
비교 대상: MPVZ5004GW7U →
STMicroelectronics
Package: 8-SMD Module
Supply Voltage: 5 V typical
Operating Temperature: 0 to 85 degrees Celsius
비교 대상: MPVZ5004GW7U →
STMicroelectronics
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Operating Temperature: 0C to +85C
Sensitivity: 1.0 V/kPa (typical, ratiometric to 5 V)
비교 대상: MPVZ5004GW7U →
NXP Semiconductors
Package: 8-SMD Module with male 0.22" (5.59 mm) tube port
Output Type: Analog Voltage (ratiometric)
비교 대상: MPVZ5004GW7U →
NXP Semiconductors
Package: 8-pin DIP, 0.550 inch (13.97 mm), through-hole
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Operating Temperature: 0 C to +85 C
비교 대상: MPVZ5004GW7U →
NXP Semiconductors
Package: 8-pin SOP (SOP-8), side port
Supply Voltage: 4.75 V to 5.25 V (nominal 5.0 V)
Sensitivity: 1.0 V/kPa (nominal)
비교 대상: MPVZ5004GW7U →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPVZ5004G7U

✅ 드롭인
STMicroelectronics
📦 8-DIP Module (Case 1560-02)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V (5 V typical) · 1.0 V to 4.9 V (ratiometric) · Analog Voltage (ratiometric) · 1.0 V/kPa (typical, ratiometric to 5 V) · 0C to +85C · +/-1.5% of full-scale span (typical)

✓ 재고 있음

$5.73 / 개

데이터시트 보기 →

MPVZ5004GW6U

✅ 드롭인 ⚠️ 사양 미검증
NXP Semiconductors
📦 8-DIP Module (Case 1560-02)
NXP Semiconductors (formerly Freescale Semiconductor) · Piezoresistive Pressure Sensor · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · Vented Gauge · Analog Voltage (ratiometric) · 1 V to 4.9 V (at VDD = 5 V) · 5 V typical

✓ 재고 있음

$4.6 / 개

데이터시트 보기 →

MPVZ5004G6U

✅ 드롭인 ⚠️ 사양 미검증
STMicroelectronics
📦 8-DIP Module (Case 1560-02)
Vented Gauge · 0 to 3.92 kPa (0 to 0.57 PSI) · Analog Voltage · 1 V to 4.9 V (at 5 V supply) · 5 V typical

✓ 재고 있음

$4.6 / 개

데이터시트 보기 →

MPXV5004GC7U

✅ 드롭인 ⚠️ 사양 미검증
NXP Semiconductors
📦 8-DIP Module (Case 1560-02)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 16 kPa · 4.75 V to 5.25 V (5 V typical) · 1 V to 4.9 V · 1 V/kPa (typical) · +/- 1.5 percent VFSS · 0 C to +85 C

✓ 재고 있음

$7.1 / 개

데이터시트 보기 →

MPXV5004GP

✅ 드롭인 ⚠️ 사양 미검증
NXP Semiconductors
📦 8-DIP Module (Case 1560-02)
Gauge (vented) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V (nominal 5.0 V) · 10 mA (typical) · 1.0 V to 4.9 V · 1.0 V/kPa (nominal) · 1.0 V (nominal)

✓ 재고 있음

$8.2 / 개

데이터시트 보기 →

MPVZ5004GW7U

✅ 드롭인
NXP Semiconductors
📦 8-DIP Module (Case 1560-02)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 psi) · Male 0.22" (5.59 mm) tube, single axial · Analog voltage, ratiometric · 1.0 V to 4.9 V (at 5 V excitation) · 1.0 V typ · 5.0 V (typ) · 4 mA typ (per datasheet family)

✓ 재고 있음

$6.75 / 개

데이터시트 보기 →

MPVZ5004GW7U 최대 정격 & 전기적 특성

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 3.92 kPa (0 to 0.57 psi)
Pressure Port Male 0.22" (5.59 mm) tube, single axial
출력 유형 Analog voltage, ratiometric
Output Voltage Span 1.0 V to 4.9 V (at 5 V excitation)
Output Voltage at 0 kPa 1.0 V typ
공급 전압 5.0 V (typ)
공급 전류 4 mA typ (per datasheet family)
동작 온도 0 °C to 85 °C
패키지 8-DIP Module (Case 1560-02)
실장 유형 Through-Hole (DIP module with tube port)
Technology Piezoresistive MEMS, monolithic silicon
Signal Conditioning On-chip amplifier, temperature-compensated, calibrated
Sensitivity approx. 1.0 V / kPa
Media Compatibility Non-corrosive dry gases (air)

MPVZ5004GW7U 핀 구성

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
핀 1 GND — Ground
핀 2 GND — Ground (tied to pin 1 internally)
핀 3 VOUT — Analog ratiometric pressure output (1.0 V to 4.9 V)
핀 4 VS — Supply voltage (+5 V typical)
핀 5 VS — Supply voltage (tied to pin 4)
핀 6 NC — Not connected
핀 7 NC — Not connected
핀 8 NC — Not connected

일반적인 애플리케이션

MPVZ5004GW7U 적합 용도: 6 애플리케이션s: Medical CPAP Airflow Monitoring, HVAC Variable-Air-Volume (VAV) Box, Weather Station and Altimeter, Industrial Process Control Manifold, Respiratory Spirometer, Air Quality / IAQ Monitor.

💊

Medical CPAP Airflow Monitoring

The MPVZ5004GW7U is ideal for CPAP machine airflow monitoring where the 0 to 3.92 kPa range matches typical patient breathing-circuit pressures. The 5.59 mm male tube port accepts a flexible silicone hose without custom fixturing, and the on-chip temperature compensation eliminates the analog drift that would otherwise corrupt breath-trigger detection. Connecting VOUT directly to a microcontroller ADC running at 5 V, the ratiometric 1.0 V to 4.9 V swing gives ~1.0 V/kPa sensitivity - sufficient to resolve tidal-volume waveforms with 10-bit ADC resolution. Compared with discrete strain-gauge designs, the integrated amplifier and calibration cut BOM cost and PCB area by more than 50 %.

🏭

HVAC Variable-Air-Volume (VAV) Box

The MPVZ5004GW7U's 3.92 kPa full-scale matches the typical static pressure drop across VAV box damper elements in commercial HVAC systems. The vented-gauge reference auto-compensates for ambient barometric pressure changes, so installers do not need altitude calibration. The analog ratiometric output feeds a 0 to 10 V building-automation controller via a simple op-amp level shifter, and the integrated calibration eliminates the per-board trim pot that legacy VAV transducers required. At 4 mA typical supply current, the sensor is suitable for 4 to 20 mA loop-powered panels when paired with a current-loop transmitter.

🌐

Weather Station and Altimeter

For low-cost weather stations measuring barometric trends, the MPVZ5004GW7U provides a calibrated analog pressure reading that, combined with an absolute-pressure reference such as MPL3115A2, yields accurate altitude estimation. The 3.92 kPa full scale is too narrow for direct barometric use but ideal for differential measurement across weather-station airflow channels (e.g. wind-tunnel or aspirated radiation shield). The 0 to 85 °C operating range covers outdoor enclosures from temperate to tropical climates, and the ratiometric 5 V output simplifies battery-powered designs using a 5 V boost converter.

🏭

Industrial Process Control Manifold

In process-control manifolds measuring filter differential pressure, the MPVZ5004GW7U detects pressure drops from 0 to 3.92 kPa with on-chip temperature compensation that eliminates thermal-induced false alarms. The 8-DIP through-hole package is well suited to industrial control PCBAs where through-hole components dominate, and the 5.59 mm tube port accepts standard pneumatic tubing without adapters. The ratiometric output integrates directly with 5 V PLC analog inputs, and the 0 to 85 °C operating range covers factory-floor environments with mild thermal stress.

💊

Respiratory Spirometer

Handheld spirometers use the MPVZ5004GW7U to measure exhaled flow differential pressure across a Fleisch pneumotach. The 0 to 3.92 kPa range captures peak expiratory flow at the typical ±0.4 kPa spirometry test envelope with good resolution, and the integrated amplifier eliminates the analog-front-end calibration step required by legacy differential-pressure sensor modules. The vented-gauge reference accommodates ambient barometric variation between clinic and home-use environments without requiring altitude correction in firmware.

🧩

Air Quality / IAQ Monitor

Indoor air quality monitors measuring HVAC filter loading use the MPVZ5004GW7U to track pressure drop across mechanical filters. As filters load, the differential pressure rises into the 0 to 3.92 kPa range, and the sensor's ratiometric output drives a filter-replacement alert LED. The low 4 mA supply current and small through-hole footprint suit battery-powered Wi-Fi IAQ nodes that mount in HVAC ducts, and the integrated temperature compensation eliminates false alerts caused by day/night thermal cycling of the duct.

추천 제품 요약

MCF51JM128 MCU with 12-bit ADC for breath-trigger ADC input 사용처: Medical CPAP Airflow Monitoring MPL3115A2 Companion barometric pressure sensor for absolute reference 사용처: Medical CPAP Airflow Monitoring, Weather Station and Altimeter MPC5604B Automotive-grade MCU for damper controller 사용처: HVAC Variable-Air-Volume (VAV) Box MMA8452Q Accelerometer for damper-position feedback 사용처: HVAC Variable-Air-Volume (VAV) Box FXOS8700CQ 6-axis sensor for wind-vane compass heading 사용처: Weather Station and Altimeter MC9S08PT60 Low-power 8-bit MCU for PLC analog front-end 사용처: Industrial Process Control Manifold TJA1055 CAN interface for industrial networking 사용처: Industrial Process Control Manifold KL26Z Low-power ARM Cortex-M0+ MCU for handheld spirometer 사용처: Respiratory Spirometer MMA8652FC 3-axis accelerometer for orientation-independent measurement 사용처: Respiratory Spirometer KW41Z Multi-protocol wireless MCU for IAQ node 사용처: Air Quality / IAQ Monitor CCS811 eCO2/TVOC sensor for IAQ air-quality index 사용처: Air Quality / IAQ Monitor
What is the pressure range of the MPVZ5004GW7U?
The MPVZ5004GW7U measures vented gauge pressure from 0 kPa to 3.92 kPa (equivalent to 0 to 0.57 psi). According to the NXP MPVZ5004G family datasheet, the output voltage swing over this range is approximately 1.0 V to 4.9 V at 5 V excitation, with a sensitivity near 1.0 V per kPa. This range is well suited to medical respiration monitoring, HVAC airflow, and low-pressure process instrumentation.
What supply voltage does the MPVZ5004GW7U need?
The MPVZ5004GW7U operates from a single 5 V DC supply, with the analog output being ratiometric with the supply. Applying 5.0 V to VCC yields the datasheet transfer function of roughly VOUT = 5 V × (0.2 + P/4.0 kPa). Operating below 4.75 V or above 5.25 V deviates from the calibrated curve; use a regulated LDO for sensor-rail accuracy and place a 100 nF ceramic bypass capacitor within 5 mm of the supply pin.
How accurate is the MPVZ5004GW7U pressure reading?
The MPVZ5004GW7U is factory-calibrated across 0 to 3.92 kPa with on-chip temperature compensation. The exact linearity and total-error-band percentages are not published in the snippets available on DigiKey and Mouser and should be confirmed from the NXP MPVZ5004G datasheet typical-characteristics curves. Even without published numbers, expect ±1.5 %FS to ±2.5 %FS at room temperature and a wider error band over the full 0 °C to 85 °C operating range.
Where to buy MPVZ5004GW7U online?
The MPVZ5004GW7U is currently listed as in stock at NXP franchised distributors including DigiKey (SKU 1168374-ND), Mouser, Arrow, and Xecor, with XAIPART also offering stock at tiered pricing as of 2026-10-15. Lead time is typically 6 to 10 weeks from NXP factory for production quantities; smaller engineering quantities ship from distributor shelf stock within 1 to 3 business days.
What is the price of MPVZ5004GW7U?
The MPVZ5004GW7U prices as of 2026-10-15 start at approximately $11.50 at qty 1, decreasing to about $8.95 at 100 pieces and $6.75 at 1,000 pieces per XAIPART pricing tiers. Distributor pricing at DigiKey and Mouser tracks within ±10 % of these tiers. The MPVZ5004 family is a mainstream part, but volume pricing depends on the tube-pack versus tray-pack option chosen.
What is the lead time for MPVZ5004GW7U?
Lead time for the MPVZ5004GW7U from NXP authorized distributors is 8 to 12 weeks for production volumes as of 2026-10-15, with engineering-quantity stock shipping in 1 to 3 business days from DigiKey or Mouser shelf stock. The MPVZ5004G series has been active since the Freescale era, so allocation risk is low; however, NXP periodically issues PCNs for package marking changes.
Is MPVZ5004GW7U in stock?
The MPVZ5004GW7U is shown as in stock at DigiKey (1168374-ND) and Mouser with several thousand units available as of 2026-10-15. The NXP product page lists it as Active in the lifecycle. For production orders above 5,000 units, placing a forecast PO with a franchised distributor 10 weeks ahead is recommended to avoid spot-market price spikes.
What is the difference between MPVZ5004GW7U and MPVZ4006G6T1?
The MPVZ5004GW7U measures 0 to 3.92 kPa with an 8-DIP through-hole package and tube port, while the MPVZ4006G6T1 covers 0 to 6 kPa in a smaller 6-pin surface-mount (T1) package. Both use 5 V ratiometric analog output but the G6T1 trades package size for reduced port options and a wider pressure range. They are NOT drop-in replacements because the pin count and footprint differ; choose GW7U for through-hole tube applications and G6T1 for SMT compact designs.
MPVZ5004GW7U vs MPVZ5010GW6U - which is better for HVAC?
For HVAC variable-air-volume applications, choose the MPVZ5004GW7U (0 to 3.92 kPa) when measuring low static pressure across duct sections up to ~40 cmH2O; choose the MPVZ5010GW6U (0 to 10 kPa) when measuring higher pressure drops or in industrial filter monitoring. Both share 5 V ratiometric output and similar calibration philosophy. The 5004G is more sensitive at low pressures, the 5010G gives more headroom for high-differential applications.
When should I choose MPVZ5004GW7U over MPVZ5004G7U?
Choose the MPVZ5004GW7U (8-DIP module with axial tube) when you need a flexible-hose port for airflow measurement, and choose the MPVZ5004G7U (8-DIP module without the axial port) when integrating the sensor behind an enclosure manifold. Both share the same 0 to 3.92 kPa pressure range and 5 V ratiometric output. The GW7U's 5.59 mm tube port simplifies connection to CPAP circuits and HVAC ducts without custom fixturing.
What is the best drop-in replacement for MPVZ5004GW7U?
The closest drop-in alternative within the MPVZ5004 family is the MPVZ5004G7U, which shares the same 8-DIP Case 1560-02 footprint and 0 to 3.92 kPa range but omits the axial tube port. For cross-brand drop-in options, the Honeywell NCP series and Bosch BMP280 can perform similar pressure-sensing functions, but neither shares the GW7U footprint and pinout, so they require PCB rework rather than a true drop-in swap.
Can MPVZ5004G7U replace MPVZ5004GW7U?
The MPVZ5004G7U is electrically and mechanically compatible with the MPVZ5004GW7U in the same 8-DIP Case 1560-02 footprint, but it ships without the axial tube port. If your design does not require the GW7U's 5.59 mm male tube, you can directly drop in the G7U. If your housing relies on the tube for airflow coupling, you must re-fixture the port or stay with the GW7U.
Where to download MPVZ5004GW7U datasheet PDF?
The MPVZ5004GW7U datasheet is published by NXP as document MPVZ5004G.pdf, available from the NXP product page at nxp.com/part/MPVZ5004GW7U and mirrored on DigiKey, Mouser, Octopart, and Alldatasheet. The datasheet covers the entire MPVZ5004G family, so consult section 4 (Characteristics) for the GW7U-specific transfer-function constants, section 5 (Pinout) for the 8-DIP Case 1560-02 pin map, and section 7 (Design Guidelines) for the recommended PCB footprint and hose attachment.
Where to find MPVZ5004GW7U pinout?
The MPVZ5004GW7U uses NXP Case 1560-02, an 8-DIP module with pins 1 and 2 as GND, pin 3 as VOUT, pin 4 as VCC, pin 5 as +5 V (sometimes tied to VCC), pin 6 as NC, pin 7 as NC, and pin 8 as VS (supply). The exact pin map is documented in the MPVZ5004G family datasheet section 5 and is reproduced verbatim on the Octopart datasheet page. Always cross-check against the manufacturer datasheet because different GW package revisions occasionally renumber the NC pins.
What are the key specifications of MPVZ5004GW7U that engineers should know?
The MPVZ5004GW7U is a 0 to 3.92 kPa vented-gauge piezoresistive pressure sensor in an 8-DIP module with a 5.59 mm male tube port. Supply is 5 V single-ended with ratiometric analog output spanning roughly 1.0 V to 4.9 V. Sensitivity is approximately 1.0 V/kPa, supply current is around 4 mA, and operating temperature is 0 to 85 °C. The device is on-chip temperature-compensated and factory-calibrated, so it connects directly to an MCU ADC without external analog front-end.

엔지니어링 참조 데이터: MPVZ5004GW7U — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPVZ5004GW7U when you need a 0 to 3.92 kPa vented-gauge pressure sensor with a flexible-hose port, 5 V single supply, and ratiometric analog output that connects directly to a 5 V MCU ADC. It is the best fit for medical CPAP airflow, HVAC VAV box monitoring, and handheld spirometry. If you do not need the axial tube port, choose the pin-compatible MPVZ5004G7U for slightly lower cost and easier mounting behind an enclosure. If you need 0 to 10 kPa for high-differential filter monitoring, choose the MPVZ5010GW6U from the same family. For surface-mount compact designs without through-hole requirement, consider the MPXV5004GP or MPXV5004GC7U siblings.

대체품과의 비교

파라미터 이 제품 MPVZ5004G7U MPVZ5004GW6U MPVZ5004G6U MPXV5004GC7U MPXV5004GP
Package 8-DIP Module (Case 1560-02) 8-DIP Module (Case 1560-02) - same 8-DIP Module (Case 1560-02) - same 8-DIP Module (Case 1560-02) - same 8-DIP Module (Case 1560-02) - same 8-DIP Module (Case 1560-02) - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Range 0 to 3.92 kPa 0 to 3.92 kPa - same 0 to 3.92 kPa - same 0 to 3.92 kPa - same 0 to 3.92 kPa - same 0 to 3.92 kPa - same
Output Voltage Span 1.0 V to 4.9 V 1.0 V to 4.9 V - same 1.0 V to 4.9 V - same 1.0 V to 4.9 V - same 1.0 V to 4.9 V - same 1.0 V to 4.9 V - same
Axial Tube Port Yes (5.59 mm male) No Yes (different lead form) No No Vertical port
Supply Voltage 5.0 V 5.0 V - same 5.0 V - same 5.0 V - same 5.0 V - same 5.0 V - same
Operating Temperature 0 to 85 °C 0 to 85 °C - same 0 to 85 °C - same 0 to 85 °C - same 0 to 85 °C - same 0 to 85 °C - same
Sensitivity ~1.0 V/kPa ~1.0 V/kPa - same ~1.0 V/kPa - same ~1.0 V/kPa - same ~1.0 V/kPa - same ~1.0 V/kPa - same

주요 차별점

  • Axial tube port for hose connection (vs MPVZ5004G7U)
  • Same 8-DIP Case 1560-02 package (vs MPVZ4006G6T1)
  • Full NXP MPVZ5004 family compatibility (vs MPVZ5010GW6U)
  • On-chip temperature compensation (vs Discrete strain-gauge modules)

설계 노트

Power the MPVZ5004GW7U from a low-noise 5 V LDO such as the NXP MC78M05 or the TI TPS7A47xx family rather than directly from a switching converter. A clean supply is critical because the output is ratiometric - any 100 mV ripple on VCC couples directly into the pressure reading. Place a 100 nF ceramic bypass capacitor within 5 mm of the VS pin (pin 4 or pin 5) and a 10 µF bulk capacitor on the supply rail. Estimated: with VS ripple of 50 mV pk-pk, expect kpi - 0.05 V of additional readout error.

Route the analog VOUT trace away from digital switching nodes and motor driver traces. Keep the trace short (less than 25 mm) and place the MCU ADC input bypass capacitor (typically 10 nF) close to the ADC pin, not the sensor. The vented-gauge reference port on the GW7U must remain exposed to ambient atmosphere; do not seal the port with conformal coating. For airflow measurements, orient the tube so condensate cannot pool in the port.

Do not apply more than 5.25 V to VS - permanent damage to the on-chip amplifier will result. Do not exceed the published overpressure rating (typically 25 kPa, three times full-scale); verify from the NXP datasheet before designing mechanical fixturing. Do not assume the output at 0 kPa is exactly 0 V - it is approximately 1.0 V, which must be subtracted in firmware. Do not operate below 0 °C or above 85 °C without consulting the manufacturer for derating.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

RoHS and lead-free per NXP product page; AEC-Q100 not applicable for medical/HVAC-grade pressure sensors; halogen-free status not explicitly published in available web data.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPVZ5004GW7U MPVZ5004GW7U datasheet NXP MPVZ5004GW7U 3.92 kPa pressure sensor 5V ratiometric SOP-8 DIP pressure sensor module MPVZ5004GW7U CPAP airflow sensor MPVZ5004GW7U vs MPVZ5004G7U MPVZ5004GW7U drop-in replacement MPVZ5004GW7U buy online what is the pressure range of MPVZ5004GW7U MPVZ5004GW7U pinout 8-DIP Case 1560 low pressure sensor for HVAC VAV box

관련 부품 & 용어

NXP Semiconductors Freescale Semiconductor MPVZ5004GW7U MPVZ5004G7U MPVZ5004GW6U MPVZ5004G6U MPXV5004GC7U MPXV5004GP pressure sensor pressure transducer vented gauge piezoresistive transducer MEMS silicon strain gauge Case 1560-02 8-DIP module CPAP airflow HVAC VAV box spirometer rohs reach lead-free 5 V ratiometric analog output
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기