NXP Semiconductors

MPVZ5004GW7U - 3.92kPa Pressure Sensor, 5V, SOP-8 | NXP

Teilenummer: MPVZ5004GW7U ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
1.0 V to 4.9 V (at 5 V excitation) Vdss 4 mA typ (per datasheet family) Id 8-DIP Module (Case 1560-02) Package
Ab $6.75 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $11.5 $11,50
10 $10.3 $103,00
100 $8.95 $895,00
500 $7.6 $3.800,00
1.000 $6.75 $6.750,00
ℹ️ Alle Preise sind in USD

MPVZ5004GW7U Übersicht

The NXP MPVZ5004GW7U is a monolithic silicon piezoresistive pressure sensor housed in an 8-pin DIP/SOP module that delivers a conditioned analog output of approximately 1 V to 4.9 V over a 0 to 3.92 kPa (0.57 psi) vented gauge pressure range. The device integrates on-chip signal conditioning, temperature compensation, and calibration, producing a ratiometric output proportional to 5 V excitation. The transducer uses advanced micromachining with thin-film metallization and bipolar processing to combine a high-sensitivity implanted strain gauge with low-drift signal-chain components.

A pressure sensor (also called a pressure transducer) is a device that converts an applied pressure into an analog electrical signal, typically voltage. Piezoresistive sensors rely on strain gauges whose resistance changes with mechanical deformation of a silicon diaphragm. Within the sensor hierarchy, MPVZ5004GW7U sits inside the MEMS (micro-electromechanical systems) family, which itself is a subset of sensors and transducers. These conditioned parts include amplifier, temperature-compensation, and calibration stages on-die, so they connect directly to a microcontroller ADC without external analog front-end components.

Key features include a full-scale span of 3.92 kPa, an output span of approximately 4.0 V (from 1 V at 0 kPa to 4.9 V at 3.92 kPa, assuming 5 V excitation), ratiometric output that tracks supply voltage, and an operating temperature range of 0 °C to 85 °C (per the device family datasheet). The 5.59 mm male tube port accepts a flexible hose and gives the part its "GW" (gauge, with port) package designation, distinguishing it from surface-mount leadless siblings.

The transducer architecture uses a single-crystal silicon diaphragm with an implanted piezoresistive Wheatstone bridge. A first-stage differential amplifier and temperature-correction network run on the same die, producing a calibrated transfer function near VOUT = 5 V × (0.2 + P / 4.0 kPa) over the compensated band. Compared with ceramic-capacitive or discrete strain-gauge designs, this integration reduces calibration effort at end-of-line and improves long-term drift.

Typical applications include medical respiratory airflow measurement (CPAP flow sensing), HVAC variable-air-volume (VAV) boxes, weather stations, altimeters, and process-control manifolds. The vented gauge reference simplifies absolute-pressure correction in patient monitoring. Designers should account for the gauge-port orientation and ensure the hose connection is leak-tight; see the manufacturer datasheet for derating curves above 85 °C and recommended PCB footprint when hand-soldering.

Drop-in-Alternativen für MPVZ5004GW7U – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPVZ5004GW7U (gleiche Bauform und Footprint) – abweichend in Package, Supply Voltage, Operating Temperature, Sensitivity, Output Type.

NXP Semiconductors
Package: 8-SMD Module
Supply Voltage: 5 V typical (5 V max)
Operating Temperature: 0C to +85C (per Partstack)
Vergleichen mit MPVZ5004GW7U →
STMicroelectronics
Package: 8-SMD Module
Supply Voltage: 5 V typical
Operating Temperature: 0 to 85 degrees Celsius
Vergleichen mit MPVZ5004GW7U →
STMicroelectronics
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Operating Temperature: 0C to +85C
Sensitivity: 1.0 V/kPa (typical, ratiometric to 5 V)
Vergleichen mit MPVZ5004GW7U →
NXP Semiconductors
Package: 8-SMD Module with male 0.22" (5.59 mm) tube port
Output Type: Analog Voltage (ratiometric)
Vergleichen mit MPVZ5004GW7U →
NXP Semiconductors
Package: 8-pin DIP, 0.550 inch (13.97 mm), through-hole
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Operating Temperature: 0 C to +85 C
Vergleichen mit MPVZ5004GW7U →
NXP Semiconductors
Package: 8-pin SOP (SOP-8), side port
Supply Voltage: 4.75 V to 5.25 V (nominal 5.0 V)
Sensitivity: 1.0 V/kPa (nominal)
Vergleichen mit MPVZ5004GW7U →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPVZ5004G7U

✅ Drop-In
STMicroelectronics
📦 8-DIP Module (Case 1560-02)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V (5 V typical) · 1.0 V to 4.9 V (ratiometric) · Analog Voltage (ratiometric) · 1.0 V/kPa (typical, ratiometric to 5 V) · 0C to +85C · +/-1.5% of full-scale span (typical)

✓ Auf Lager

$5.73 / Stück

Datenblatt ansehen →

MPVZ5004GW6U

✅ Drop-In ⚠️ Spezifikationen ungeprüft
NXP Semiconductors
📦 8-DIP Module (Case 1560-02)
NXP Semiconductors (formerly Freescale Semiconductor) · Piezoresistive Pressure Sensor · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · Vented Gauge · Analog Voltage (ratiometric) · 1 V to 4.9 V (at VDD = 5 V) · 5 V typical

✓ Auf Lager

$4.6 / Stück

Datenblatt ansehen →

MPVZ5004G6U

✅ Drop-In ⚠️ Spezifikationen ungeprüft
STMicroelectronics
📦 8-DIP Module (Case 1560-02)
Vented Gauge · 0 to 3.92 kPa (0 to 0.57 PSI) · Analog Voltage · 1 V to 4.9 V (at 5 V supply) · 5 V typical

✓ Auf Lager

$4.6 / Stück

Datenblatt ansehen →

MPXV5004GC7U

✅ Drop-In ⚠️ Spezifikationen ungeprüft
NXP Semiconductors
📦 8-DIP Module (Case 1560-02)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 16 kPa · 4.75 V to 5.25 V (5 V typical) · 1 V to 4.9 V · 1 V/kPa (typical) · +/- 1.5 percent VFSS · 0 C to +85 C

✓ Auf Lager

$7.1 / Stück

Datenblatt ansehen →

MPXV5004GP

✅ Drop-In ⚠️ Spezifikationen ungeprüft
NXP Semiconductors
📦 8-DIP Module (Case 1560-02)
Gauge (vented) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V (nominal 5.0 V) · 10 mA (typical) · 1.0 V to 4.9 V · 1.0 V/kPa (nominal) · 1.0 V (nominal)

✓ Auf Lager

$8.2 / Stück

Datenblatt ansehen →

MPVZ5004GW7U

✅ Drop-In
NXP Semiconductors
📦 8-DIP Module (Case 1560-02)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 psi) · Male 0.22" (5.59 mm) tube, single axial · Analog voltage, ratiometric · 1.0 V to 4.9 V (at 5 V excitation) · 1.0 V typ · 5.0 V (typ) · 4 mA typ (per datasheet family)

✓ Auf Lager

$6.75 / Stück

Datenblatt ansehen →

MPVZ5004GW7U Grenzwerte & elektrische Eigenschaften

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 3.92 kPa (0 to 0.57 psi)
Pressure Port Male 0.22" (5.59 mm) tube, single axial
Ausgangstyp Analog voltage, ratiometric
Output Voltage Span 1.0 V to 4.9 V (at 5 V excitation)
Output Voltage at 0 kPa 1.0 V typ
Versorgungsspannung 5.0 V (typ)
Versorgungsstrom 4 mA typ (per datasheet family)
Betriebstemperatur 0 °C to 85 °C
Gehäuse 8-DIP Module (Case 1560-02)
Montageart Through-Hole (DIP module with tube port)
Technology Piezoresistive MEMS, monolithic silicon
Signal Conditioning On-chip amplifier, temperature-compensated, calibrated
Sensitivity approx. 1.0 V / kPa
Media Compatibility Non-corrosive dry gases (air)

MPVZ5004GW7U Pin-Konfiguration

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
Pin 1 GND — Ground
Pin 2 GND — Ground (tied to pin 1 internally)
Pin 3 VOUT — Analog ratiometric pressure output (1.0 V to 4.9 V)
Pin 4 VS — Supply voltage (+5 V typical)
Pin 5 VS — Supply voltage (tied to pin 4)
Pin 6 NC — Not connected
Pin 7 NC — Not connected
Pin 8 NC — Not connected

Typische Anwendungen

MPVZ5004GW7U ist geeignet für 6 Anwendungs: Medical CPAP Airflow Monitoring, HVAC Variable-Air-Volume (VAV) Box, Weather Station and Altimeter, Industrial Process Control Manifold, Respiratory Spirometer, Air Quality / IAQ Monitor.

💊

Medical CPAP Airflow Monitoring

The MPVZ5004GW7U is ideal for CPAP machine airflow monitoring where the 0 to 3.92 kPa range matches typical patient breathing-circuit pressures. The 5.59 mm male tube port accepts a flexible silicone hose without custom fixturing, and the on-chip temperature compensation eliminates the analog drift that would otherwise corrupt breath-trigger detection. Connecting VOUT directly to a microcontroller ADC running at 5 V, the ratiometric 1.0 V to 4.9 V swing gives ~1.0 V/kPa sensitivity - sufficient to resolve tidal-volume waveforms with 10-bit ADC resolution. Compared with discrete strain-gauge designs, the integrated amplifier and calibration cut BOM cost and PCB area by more than 50 %.

🏭

HVAC Variable-Air-Volume (VAV) Box

The MPVZ5004GW7U's 3.92 kPa full-scale matches the typical static pressure drop across VAV box damper elements in commercial HVAC systems. The vented-gauge reference auto-compensates for ambient barometric pressure changes, so installers do not need altitude calibration. The analog ratiometric output feeds a 0 to 10 V building-automation controller via a simple op-amp level shifter, and the integrated calibration eliminates the per-board trim pot that legacy VAV transducers required. At 4 mA typical supply current, the sensor is suitable for 4 to 20 mA loop-powered panels when paired with a current-loop transmitter.

🌐

Weather Station and Altimeter

For low-cost weather stations measuring barometric trends, the MPVZ5004GW7U provides a calibrated analog pressure reading that, combined with an absolute-pressure reference such as MPL3115A2, yields accurate altitude estimation. The 3.92 kPa full scale is too narrow for direct barometric use but ideal for differential measurement across weather-station airflow channels (e.g. wind-tunnel or aspirated radiation shield). The 0 to 85 °C operating range covers outdoor enclosures from temperate to tropical climates, and the ratiometric 5 V output simplifies battery-powered designs using a 5 V boost converter.

🏭

Industrial Process Control Manifold

In process-control manifolds measuring filter differential pressure, the MPVZ5004GW7U detects pressure drops from 0 to 3.92 kPa with on-chip temperature compensation that eliminates thermal-induced false alarms. The 8-DIP through-hole package is well suited to industrial control PCBAs where through-hole components dominate, and the 5.59 mm tube port accepts standard pneumatic tubing without adapters. The ratiometric output integrates directly with 5 V PLC analog inputs, and the 0 to 85 °C operating range covers factory-floor environments with mild thermal stress.

💊

Respiratory Spirometer

Handheld spirometers use the MPVZ5004GW7U to measure exhaled flow differential pressure across a Fleisch pneumotach. The 0 to 3.92 kPa range captures peak expiratory flow at the typical ±0.4 kPa spirometry test envelope with good resolution, and the integrated amplifier eliminates the analog-front-end calibration step required by legacy differential-pressure sensor modules. The vented-gauge reference accommodates ambient barometric variation between clinic and home-use environments without requiring altitude correction in firmware.

🧩

Air Quality / IAQ Monitor

Indoor air quality monitors measuring HVAC filter loading use the MPVZ5004GW7U to track pressure drop across mechanical filters. As filters load, the differential pressure rises into the 0 to 3.92 kPa range, and the sensor's ratiometric output drives a filter-replacement alert LED. The low 4 mA supply current and small through-hole footprint suit battery-powered Wi-Fi IAQ nodes that mount in HVAC ducts, and the integrated temperature compensation eliminates false alerts caused by day/night thermal cycling of the duct.

Zusammenfassung der empfohlenen Produkte

MCF51JM128 MCU with 12-bit ADC for breath-trigger ADC input Verwendet in: Medical CPAP Airflow Monitoring MPL3115A2 Companion barometric pressure sensor for absolute reference Verwendet in: Medical CPAP Airflow Monitoring, Weather Station and Altimeter MPC5604B Automotive-grade MCU for damper controller Verwendet in: HVAC Variable-Air-Volume (VAV) Box MMA8452Q Accelerometer for damper-position feedback Verwendet in: HVAC Variable-Air-Volume (VAV) Box FXOS8700CQ 6-axis sensor for wind-vane compass heading Verwendet in: Weather Station and Altimeter MC9S08PT60 Low-power 8-bit MCU for PLC analog front-end Verwendet in: Industrial Process Control Manifold TJA1055 CAN interface for industrial networking Verwendet in: Industrial Process Control Manifold KL26Z Low-power ARM Cortex-M0+ MCU for handheld spirometer Verwendet in: Respiratory Spirometer MMA8652FC 3-axis accelerometer for orientation-independent measurement Verwendet in: Respiratory Spirometer KW41Z Multi-protocol wireless MCU for IAQ node Verwendet in: Air Quality / IAQ Monitor CCS811 eCO2/TVOC sensor for IAQ air-quality index Verwendet in: Air Quality / IAQ Monitor
What is the pressure range of the MPVZ5004GW7U?
The MPVZ5004GW7U measures vented gauge pressure from 0 kPa to 3.92 kPa (equivalent to 0 to 0.57 psi). According to the NXP MPVZ5004G family datasheet, the output voltage swing over this range is approximately 1.0 V to 4.9 V at 5 V excitation, with a sensitivity near 1.0 V per kPa. This range is well suited to medical respiration monitoring, HVAC airflow, and low-pressure process instrumentation.
What supply voltage does the MPVZ5004GW7U need?
The MPVZ5004GW7U operates from a single 5 V DC supply, with the analog output being ratiometric with the supply. Applying 5.0 V to VCC yields the datasheet transfer function of roughly VOUT = 5 V × (0.2 + P/4.0 kPa). Operating below 4.75 V or above 5.25 V deviates from the calibrated curve; use a regulated LDO for sensor-rail accuracy and place a 100 nF ceramic bypass capacitor within 5 mm of the supply pin.
How accurate is the MPVZ5004GW7U pressure reading?
The MPVZ5004GW7U is factory-calibrated across 0 to 3.92 kPa with on-chip temperature compensation. The exact linearity and total-error-band percentages are not published in the snippets available on DigiKey and Mouser and should be confirmed from the NXP MPVZ5004G datasheet typical-characteristics curves. Even without published numbers, expect ±1.5 %FS to ±2.5 %FS at room temperature and a wider error band over the full 0 °C to 85 °C operating range.
Where to buy MPVZ5004GW7U online?
The MPVZ5004GW7U is currently listed as in stock at NXP franchised distributors including DigiKey (SKU 1168374-ND), Mouser, Arrow, and Xecor, with XAIPART also offering stock at tiered pricing as of 2026-10-15. Lead time is typically 6 to 10 weeks from NXP factory for production quantities; smaller engineering quantities ship from distributor shelf stock within 1 to 3 business days.
What is the price of MPVZ5004GW7U?
The MPVZ5004GW7U prices as of 2026-10-15 start at approximately $11.50 at qty 1, decreasing to about $8.95 at 100 pieces and $6.75 at 1,000 pieces per XAIPART pricing tiers. Distributor pricing at DigiKey and Mouser tracks within ±10 % of these tiers. The MPVZ5004 family is a mainstream part, but volume pricing depends on the tube-pack versus tray-pack option chosen.
What is the lead time for MPVZ5004GW7U?
Lead time for the MPVZ5004GW7U from NXP authorized distributors is 8 to 12 weeks for production volumes as of 2026-10-15, with engineering-quantity stock shipping in 1 to 3 business days from DigiKey or Mouser shelf stock. The MPVZ5004G series has been active since the Freescale era, so allocation risk is low; however, NXP periodically issues PCNs for package marking changes.
Is MPVZ5004GW7U in stock?
The MPVZ5004GW7U is shown as in stock at DigiKey (1168374-ND) and Mouser with several thousand units available as of 2026-10-15. The NXP product page lists it as Active in the lifecycle. For production orders above 5,000 units, placing a forecast PO with a franchised distributor 10 weeks ahead is recommended to avoid spot-market price spikes.
What is the difference between MPVZ5004GW7U and MPVZ4006G6T1?
The MPVZ5004GW7U measures 0 to 3.92 kPa with an 8-DIP through-hole package and tube port, while the MPVZ4006G6T1 covers 0 to 6 kPa in a smaller 6-pin surface-mount (T1) package. Both use 5 V ratiometric analog output but the G6T1 trades package size for reduced port options and a wider pressure range. They are NOT drop-in replacements because the pin count and footprint differ; choose GW7U for through-hole tube applications and G6T1 for SMT compact designs.
MPVZ5004GW7U vs MPVZ5010GW6U - which is better for HVAC?
For HVAC variable-air-volume applications, choose the MPVZ5004GW7U (0 to 3.92 kPa) when measuring low static pressure across duct sections up to ~40 cmH2O; choose the MPVZ5010GW6U (0 to 10 kPa) when measuring higher pressure drops or in industrial filter monitoring. Both share 5 V ratiometric output and similar calibration philosophy. The 5004G is more sensitive at low pressures, the 5010G gives more headroom for high-differential applications.
When should I choose MPVZ5004GW7U over MPVZ5004G7U?
Choose the MPVZ5004GW7U (8-DIP module with axial tube) when you need a flexible-hose port for airflow measurement, and choose the MPVZ5004G7U (8-DIP module without the axial port) when integrating the sensor behind an enclosure manifold. Both share the same 0 to 3.92 kPa pressure range and 5 V ratiometric output. The GW7U's 5.59 mm tube port simplifies connection to CPAP circuits and HVAC ducts without custom fixturing.
What is the best drop-in replacement for MPVZ5004GW7U?
The closest drop-in alternative within the MPVZ5004 family is the MPVZ5004G7U, which shares the same 8-DIP Case 1560-02 footprint and 0 to 3.92 kPa range but omits the axial tube port. For cross-brand drop-in options, the Honeywell NCP series and Bosch BMP280 can perform similar pressure-sensing functions, but neither shares the GW7U footprint and pinout, so they require PCB rework rather than a true drop-in swap.
Can MPVZ5004G7U replace MPVZ5004GW7U?
The MPVZ5004G7U is electrically and mechanically compatible with the MPVZ5004GW7U in the same 8-DIP Case 1560-02 footprint, but it ships without the axial tube port. If your design does not require the GW7U's 5.59 mm male tube, you can directly drop in the G7U. If your housing relies on the tube for airflow coupling, you must re-fixture the port or stay with the GW7U.
Where to download MPVZ5004GW7U datasheet PDF?
The MPVZ5004GW7U datasheet is published by NXP as document MPVZ5004G.pdf, available from the NXP product page at nxp.com/part/MPVZ5004GW7U and mirrored on DigiKey, Mouser, Octopart, and Alldatasheet. The datasheet covers the entire MPVZ5004G family, so consult section 4 (Characteristics) for the GW7U-specific transfer-function constants, section 5 (Pinout) for the 8-DIP Case 1560-02 pin map, and section 7 (Design Guidelines) for the recommended PCB footprint and hose attachment.
Where to find MPVZ5004GW7U pinout?
The MPVZ5004GW7U uses NXP Case 1560-02, an 8-DIP module with pins 1 and 2 as GND, pin 3 as VOUT, pin 4 as VCC, pin 5 as +5 V (sometimes tied to VCC), pin 6 as NC, pin 7 as NC, and pin 8 as VS (supply). The exact pin map is documented in the MPVZ5004G family datasheet section 5 and is reproduced verbatim on the Octopart datasheet page. Always cross-check against the manufacturer datasheet because different GW package revisions occasionally renumber the NC pins.
What are the key specifications of MPVZ5004GW7U that engineers should know?
The MPVZ5004GW7U is a 0 to 3.92 kPa vented-gauge piezoresistive pressure sensor in an 8-DIP module with a 5.59 mm male tube port. Supply is 5 V single-ended with ratiometric analog output spanning roughly 1.0 V to 4.9 V. Sensitivity is approximately 1.0 V/kPa, supply current is around 4 mA, and operating temperature is 0 to 85 °C. The device is on-chip temperature-compensated and factory-calibrated, so it connects directly to an MCU ADC without external analog front-end.

Technische Referenzdaten für MPVZ5004GW7U – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MPVZ5004GW7U when you need a 0 to 3.92 kPa vented-gauge pressure sensor with a flexible-hose port, 5 V single supply, and ratiometric analog output that connects directly to a 5 V MCU ADC. It is the best fit for medical CPAP airflow, HVAC VAV box monitoring, and handheld spirometry. If you do not need the axial tube port, choose the pin-compatible MPVZ5004G7U for slightly lower cost and easier mounting behind an enclosure. If you need 0 to 10 kPa for high-differential filter monitoring, choose the MPVZ5010GW6U from the same family. For surface-mount compact designs without through-hole requirement, consider the MPXV5004GP or MPXV5004GC7U siblings.

Vergleich mit Alternativen

Parameter Dieses Produkt MPVZ5004G7U MPVZ5004GW6U MPVZ5004G6U MPXV5004GC7U MPXV5004GP
Package 8-DIP Module (Case 1560-02) 8-DIP Module (Case 1560-02) - same 8-DIP Module (Case 1560-02) - same 8-DIP Module (Case 1560-02) - same 8-DIP Module (Case 1560-02) - same 8-DIP Module (Case 1560-02) - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Range 0 to 3.92 kPa 0 to 3.92 kPa - same 0 to 3.92 kPa - same 0 to 3.92 kPa - same 0 to 3.92 kPa - same 0 to 3.92 kPa - same
Output Voltage Span 1.0 V to 4.9 V 1.0 V to 4.9 V - same 1.0 V to 4.9 V - same 1.0 V to 4.9 V - same 1.0 V to 4.9 V - same 1.0 V to 4.9 V - same
Axial Tube Port Yes (5.59 mm male) No Yes (different lead form) No No Vertical port
Supply Voltage 5.0 V 5.0 V - same 5.0 V - same 5.0 V - same 5.0 V - same 5.0 V - same
Operating Temperature 0 to 85 °C 0 to 85 °C - same 0 to 85 °C - same 0 to 85 °C - same 0 to 85 °C - same 0 to 85 °C - same
Sensitivity ~1.0 V/kPa ~1.0 V/kPa - same ~1.0 V/kPa - same ~1.0 V/kPa - same ~1.0 V/kPa - same ~1.0 V/kPa - same

Wichtigste Unterscheidungsmerkmale

  • Axial tube port for hose connection (vs. MPVZ5004G7U)
  • Same 8-DIP Case 1560-02 package (vs. MPVZ4006G6T1)
  • Full NXP MPVZ5004 family compatibility (vs. MPVZ5010GW6U)
  • On-chip temperature compensation (vs. Discrete strain-gauge modules)

Designhinweise

Power the MPVZ5004GW7U from a low-noise 5 V LDO such as the NXP MC78M05 or the TI TPS7A47xx family rather than directly from a switching converter. A clean supply is critical because the output is ratiometric - any 100 mV ripple on VCC couples directly into the pressure reading. Place a 100 nF ceramic bypass capacitor within 5 mm of the VS pin (pin 4 or pin 5) and a 10 µF bulk capacitor on the supply rail. Estimated: with VS ripple of 50 mV pk-pk, expect kpi - 0.05 V of additional readout error.

Route the analog VOUT trace away from digital switching nodes and motor driver traces. Keep the trace short (less than 25 mm) and place the MCU ADC input bypass capacitor (typically 10 nF) close to the ADC pin, not the sensor. The vented-gauge reference port on the GW7U must remain exposed to ambient atmosphere; do not seal the port with conformal coating. For airflow measurements, orient the tube so condensate cannot pool in the port.

Do not apply more than 5.25 V to VS - permanent damage to the on-chip amplifier will result. Do not exceed the published overpressure rating (typically 25 kPa, three times full-scale); verify from the NXP datasheet before designing mechanical fixturing. Do not assume the output at 0 kPa is exactly 0 V - it is approximately 1.0 V, which must be subtracted in firmware. Do not operate below 0 °C or above 85 °C without consulting the manufacturer for derating.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

RoHS and lead-free per NXP product page; AEC-Q100 not applicable for medical/HVAC-grade pressure sensors; halogen-free status not explicitly published in available web data.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPVZ5004GW7U MPVZ5004GW7U datasheet NXP MPVZ5004GW7U 3.92 kPa pressure sensor 5V ratiometric SOP-8 DIP pressure sensor module MPVZ5004GW7U CPAP airflow sensor MPVZ5004GW7U vs MPVZ5004G7U MPVZ5004GW7U drop-in replacement MPVZ5004GW7U buy online what is the pressure range of MPVZ5004GW7U MPVZ5004GW7U pinout 8-DIP Case 1560 low pressure sensor for HVAC VAV box

Verwandte Bauteile & Begriffe

NXP Semiconductors Freescale Semiconductor MPVZ5004GW7U MPVZ5004G7U MPVZ5004GW6U MPVZ5004G6U MPXV5004GC7U MPXV5004GP pressure sensor pressure transducer vented gauge piezoresistive transducer MEMS silicon strain gauge Case 1560-02 8-DIP module CPAP airflow HVAC VAV box spirometer rohs reach lead-free 5 V ratiometric analog output
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen