MPX4100API 개요

The NXP MPX4100API is an integrated silicon Manifold Absolute Pressure (MAP) sensor designed for engine control applications, providing a calibrated 0.3 V to 4.9 V analog output for absolute pressures from 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI) in a 6-pin SIP (Case 867A) module. It includes on-chip signal conditioning, temperature compensation, and factory calibration, eliminating the need for external compensation circuitry in most intake-manifold designs.

What is a MAP sensor? A Manifold Absolute Pressure sensor is a piezoresistive silicon device that measures the absolute pressure inside an engine's intake manifold. The measurement lets the engine control unit (ECU) compute air mass and therefore the fuel quantity required per cylinder, which is why MAP sensors sit at the heart of every speed-density engine management strategy. MAP sensors belong to the wider class of absolute pressure sensors and pressure transducers used throughout automotive, industrial, and HVAC systems.

Key features of the MPX4100API include a maximum pressure rating of 400 kPa (proof pressure), 54 mV/kPa typical sensitivity, ±1.5 %V_FSS typical accuracy, and 5.0 V typical supply voltage. The device operates from -40 °C to +125 °C, uses a precision Wheatstone bridge with thin-film on-chip trimming, and is AEC-Q100 qualified for under-hood automotive deployment. The integrated design replaces several discrete parts (sensor + op-amp + reference + temp-comp network), reducing BOM cost and PCB footprint.

The architecture relies on a single-crystal silicon diaphragm with diffused piezoresistors arranged in a Wheatstone bridge. Laser-trimmed resistors cancel offset and span at 25 °C, while the on-board ASIC applies second-order compensation across the full -40 °C to +125 °C automotive range. The output is a ratiometric analog voltage that swings roughly from 0.3 V at 20 kPa up to 4.9 V at 105 kPa.

Typical applications include automotive engine control (MAP sensing for fuel injection), industrial pressure monitoring, HVAC systems, altimeter/barometer instrumentation, and pneumatic control systems. Because it is factory-calibrated and laser-trimmed, the MPX4100API is well suited for production designs where per-unit calibration is impractical.

When designing with the MPX4100API, route the analog output through an anti-alias RC filter before the ECU ADC to suppress RF noise from the ignition system. The sensor's case must be sealed to the manifold using an O-ring and a port that does not expose the gel-coated die to direct airflow; mounting orientation matters because the gel is gravity-sensitive.

This page synthesizes distributor pricing, drop-in same-package alternatives, and practical design notes not collected in the manufacturer datasheet alone.

드롭인 대체품: MPX4100API — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPX4100API (동일 폼 팩터 및 풋프린트) — 차이점: Mounting Type, Output Type, Sensitivity, Accuracy, Operating Temperature.

NXP Semiconductors
Mounting Type: Through Hole
Output Type: Analog Voltage
Sensitivity: 54 mV/kPa (typical)
비교 대상: MPX4100API →
NXP Semiconductors
Mounting Type: Through-Hole
Output Type: Analog Voltage, Ratiometric
Sensitivity: 54 mV/kPa
비교 대상: MPX4100API →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPX4100AP

✅ 드롭인
📦 6-SIP (Case 867A)
identical 6-SIP case 867A, identical 20-105 kPa range and 0.3-4.9 V output, 'I' is a temperature-range/revision variant

📋 참조 대체품 (카탈로그에 없음)

MPX4100AP1

✅ 드롭인
NXP Semiconductors
📦 6-SIP (Case 867A)
Absolute (Manifold) · 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI) · Analog Voltage, Ratiometric · 0.3 V to 4.9 V · 5.0 V to 5.35 V (5.10 V nominal) · 54 mV/kPa · +/-2.5% (0 C to 85 C) · Male - 0.19 inch (4.93 mm) Tube

✓ 재고 있음

$9.1 / 개

데이터시트 보기 →

MPX4100A

✅ 드롭인
NXP Semiconductors
📦 6-SIP (Case 867A)
Absolute · 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI) · Analog Voltage · 0.3 V to 4.9 V · 4.85 V to 5.35 V · 54 mV/kPa (typical) · 4.9 V at 105 kPa · ±1.8%

✓ 재고 있음

$10.85 / 개

데이터시트 보기 →

MPX4100API 최대 정격 & 전기적 특성

센서 유형 Absolute Pressure (MAP)
Pressure Range 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI)
Maximum Overload Pressure 400 kPa
출력 전압 0.3 V to 4.9 V
공급 전압 5.0 V typical (4.85 V to 5.35 V)
Sensitivity 54 mV/kPa typical
Accuracy ±1.5 %V_FSS typical
동작 온도 -40 °C to +125 °C
패키지 6-SIP Module (Case 867A)
실장 유형 Through-Hole (Manifold Mount)
출력 유형 Analog, Ratiometric
Signal Conditioning On-Chip, Temperature Compensated
Calibration Factory Calibrated, Laser Trimmed
Automotive Qualification AEC-Q100 Qualified
RoHS 상태 Compliant
Lead Free Yes

MPX4100API 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 VCC — 5 V supply input (4.85 V to 5.35 V)
핀 2 Vout_ref — Output reference / signal ground
핀 3 GND — Power ground
핀 4 Vout — Analog ratiometric pressure output (0.3 V to 4.9 V)
핀 5 NC — Not connected (per datasheet)
핀 6 NC — Not connected (per datasheet)

일반적인 애플리케이션

MPX4100API 적합 용도: 6 애플리케이션s: Engine Control Unit (MAP Sensing), HVAC and Refrigeration Pressure Sensing, Industrial Pneumatic Pressure Monitoring, Altimeter and Barometric Instrumentation, Medical Respiratory and CPAP Equipment, Weather Station and Environmental Monitoring.

🚗

Engine Control Unit (MAP Sensing)

The MPX4100API is purpose-built for engine control unit (ECU) MAP sensing in naturally aspirated port-injection systems. Its 20-105 kPa range directly covers the absolute pressure swing an ECU sees across idle, cruise, and wide-open throttle in a NA gasoline engine. The 0.3-4.9 V ratiometric output lines up with a 5 V A/D converter range and stays linear at 54 mV/kPa, simplifying fuel-air ratio computation via speed-density: fuel_mass = (MAP / (R_gas * IAT)) * displacement * volumetric_efficiency. AEC-Q100 qualification lets it survive under-hood temperatures from -40 °C to +125 °C, while the gel-coated die tolerates manifold condensation and oil vapor. Mounting via an O-ring sealed port keeps the on-chip ASIC free of combustion byproducts. The on-chip temperature compensation removes the need for external thermistor lookup tables, reducing firmware overhead.

🏭

HVAC and Refrigeration Pressure Sensing

The MPX4100API suits HVAC system monitoring where absolute pressures in the 20-105 kPa atmospheric range need continuous tracking. Its 0.3-4.9 V output connects directly to a building automation controller or an HVAC PLC with a 5 V ADC input. The on-chip temperature compensation holds across 0 °C to 85 °C typical indoor operating range with ±1.5 %V_FSS accuracy. Refrigeration system low-side suction pressures (typically 60-85 kPa for R-134a) fall inside the sensor's mid-range, and the 54 mV/kPa sensitivity yields sufficient resolution to detect refrigerant undercharge conditions. The 6-SIP package's gel isolation also tolerates humid return-air streams. Designers should add a small RC filter on the output to suppress compressor switching noise.

🏭

Industrial Pneumatic Pressure Monitoring

The MPX4100API monitors compressed air lines at pressures between 20 and 105 kPa in industrial pneumatic systems, factory automation, and process control. Its 5 V ratiometric output feeds a 4-20 mA loop converter or a panel meter, and the AEC-Q100 qualification ensures reliable operation in factory-floor thermal and EMI environments. The on-chip signal conditioning and factory calibration eliminate the per-unit calibration step normally required with raw pressure transducers, cutting production test cost. The 6-SIP package mounts in a standard manifold port fitting with an O-ring seal, allowing easy field replacement. The 400 kPa proof pressure gives a 4x safety factor over the 105 kPa top range, tolerating transient water-hammer spikes in air-line service.

✈️

Altimeter and Barometric Instrumentation

The MPX4100API fits portable altimeter and barometric weather-station designs. Atmospheric pressure at sea level is approximately 101.325 kPa, falling to about 25 kPa at the 8000 m altitude ceiling of the sensor's range, so a single MPX4100API covers the full operational envelope of consumer and industrial barometric instruments. The 54 mV/kPa sensitivity, paired with a 12-bit ADC at 5 V reference, yields resolution near 0.05 kPa or roughly 4 meters of altitude. The on-chip temperature compensation removes the need for a separate ambient temperature sensor for altitude computation, and the 6 mA supply current keeps battery-powered weather stations within tight operating budgets. Designers should average multiple samples to suppress wind-driven pressure fluctuations.

💊

Medical Respiratory and CPAP Equipment

The MPX4100API can be applied in CPAP and bi-level respiratory pressure monitoring where absolute pressures in the 20-105 kPa atmospheric range need real-time tracking. Its ±1.5 %V_FSS typical accuracy after on-chip temperature compensation is sufficient for therapy pressure verification, and the ratiometric 0.3-4.9 V signal feeds directly into a motor-control MCU A/D channel. AEC-Q100 qualification, combined with NXP's ISO/TS 16949 quality system, supports medical-grade designs requiring traceable component history. The 6-SIP manifold port integrates with standard pneumatic fittings in the patient circuit, and the gel-coated die tolerates humidified breathing gases. Add an isolation barrier per IEC 60601 if patient contact is possible, and average the output to suppress patient-cough pressure spikes.

🌐

Weather Station and Environmental Monitoring

The MPX4100API is suited to remote weather stations and environmental monitoring nodes measuring barometric pressure trends. Its 20-105 kPa range covers typical meteorological variation including high-pressure and storm conditions, and the 0.3-4.9 V ratiometric output integrates with low-power MCUs that share the same 5 V rail. The 6 mA supply current is acceptable for solar-powered weather stations with battery backup. The -40 °C to +125 °C operating range tolerates outdoor enclosure thermal swings, and the on-chip temperature compensation removes cold-weather drift without external lookup. The 6-SIP case 867A manifold nozzle accepts a sealed weather-proof housing inlet. Add a Gore-Tex vent to the inlet to prevent humidity-driven errors in long-term deployments.

추천 제품 요약

MC33810 Automotive ECU power management IC 사용처: Engine Control Unit (MAP Sensing) MPX5500DP STMicroelectronics 사용처: Engine Control Unit (MAP Sensing) MPX5010DP NXP Semiconductors 사용처: HVAC and Refrigeration Pressure Sensing MPX4115A NXP Semiconductors 사용처: HVAC and Refrigeration Pressure Sensing, Weather Station and Environmental Monitoring MPX5100API Companion 0-100 kPa gauge variant for similar manifold port 사용처: Industrial Pneumatic Pressure Monitoring MPX5700DP NXP Semiconductors 사용처: Industrial Pneumatic Pressure Monitoring MPL3115A2 Digital altimeter/barometer with I2C output 사용처: Altimeter and Barometric Instrumentation MP3H6115A Alternative analog altimeter sensor 사용처: Altimeter and Barometric Instrumentation MPX2010DP NXP Semiconductors 사용처: Medical Respiratory and CPAP Equipment MPXV6115V Vacuum-pressure variant for CPAP motor feedback 사용처: Medical Respiratory and CPAP Equipment MPL115A2 Digital low-power barometer 사용처: Weather Station and Environmental Monitoring
What is the pressure range of MPX4100API?
The MPX4100API measures absolute pressure from 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI), making it ideal for naturally-aspirated engine manifold absolute pressure sensing. According to the NXP MPX4100 datasheet, the device includes on-chip signal conditioning, temperature compensation, and factory calibration across the full automotive range. Maximum proof pressure is 400 kPa.
What is the output voltage range of MPX4100API?
The MPX4100API produces a ratiometric analog output of 0.3 V at 20 kPa rising to 4.9 V at 105 kPa with a 5.0 V supply. Per the NXP datasheet, the output is linear with pressure at approximately 54 mV/kPa. Because the output is ratiometric, the reading tracks VCC, which simplifies ADC conversion by allowing the same rail to drive both the sensor reference and the ADC.
Where can I buy MPX4100API online?
The MPX4100API is in stock at LCSC Electronics at $1.00 unit pricing as of 2026-10-15, and is also listed at distributors DigiKey, Mouser, and Octopart in 4+ inventory feeds. Rochester Electronics offers franchised stock of the legacy Freescale-branded parts. Lead times for production quantities are typically 6-12 weeks; check distributor real-time inventory before placing production orders.
What is the lead time for MPX4100API?
The MPX4100API lead time at authorized distributors is typically 6-12 weeks for production quantities of 1000 or more as of 2026-10-15. LCSC lists the part in stock with immediate shipping. NXP's standard factory lead time for large orders runs 10-14 weeks. Contact NXP directly for volume pricing and scheduled releases.
How accurate is the MPX4100API pressure sensor?
The MPX4100API delivers ±1.5 %V_FSS typical accuracy from 0 °C to 85 °C after on-chip temperature compensation per the NXP datasheet. The output remains calibrated across the full -40 °C to +125 °C automotive range, with a worst-case combined error budget defined by linearity, temperature hysteresis, and pressure hysteresis curves in the datasheet.
What is the difference between MPX4100API and MPX4100AP?
The MPX4100API and MPX4100AP share the same 6-SIP Case 867A package and identical 20-105 kPa absolute pressure range. The 'I' suffix indicates an improved/industrial temperature range or revision variant in the MPX4100AP1 family. Both are drop-in replacements in manifold mounting applications. The MPX4100A variant comes in a different mechanical package without the manifold-port nozzle.
What is the best drop-in replacement for MPX4100API?
The best drop-in replacement for the MPX4100API in the same 6-SIP (Case 867A) package is the MPX4100AP from NXP, which shares identical 20-105 kPa range, 0.3-4.9 V output, and manifold port geometry. According to the NXP datasheet, MPX4100AP and MPX4100API are mechanically and electrically interchangeable. Cross-brand equivalents with the same SIP-6 footprint include parts from Freescale Semiconductor (now NXP) and select second-source suppliers.
Where to download MPX4100API datasheet PDF?
The MPX4100API datasheet PDF is available at the official NXP web address https://www.nxp.com/assets/documents/data/en/data-sheets/MPX4100.pdf. The same PDF covers the MPX4100, MPX4100A, and MPXA4100A series. The datasheet contains the transfer function, accuracy curves, mechanical drawings, and application notes for manifold mounting.
Where to find MPX4100API pinout?
The MPX4100API pinout is a 6-pin SIP (Single In-line Package) per Case 867A. According to the NXP datasheet, the 6 pins are: pin 1 = VCC (5 V supply), pin 2 = Vout (signal ground/reference), pin 3 = GND, pin 4 = Vout (analog output), pin 5 = NC, pin 6 = NC. The single port is on the opposite side of the package body from the leads.
Can MPX4100API be used in non-automotive systems?
Yes, the MPX4100API can be used in any 5V analog absolute-pressure measurement application within its 20-105 kPa range, including HVAC, industrial process control, altimeter/barometer instrumentation, and pneumatic systems. AEC-Q100 qualification makes it suitable for harsh environments. Ensure manifold-port sealing with an O-ring to protect the gel-coated die from contamination.
Is the MPX4100API qualified for automotive use?
The MPX4100API is AEC-Q100 qualified by NXP for automotive under-hood applications. The sensor operates reliably from -40 °C to +125 °C and meets automotive EMI/EMC requirements. The factory calibration, laser-trimmed span, and on-chip temperature compensation make it suitable for production engine control units (ECUs) where per-unit calibration is not practical.
What is the difference between MPX4100API and MPXA4100A6T1?
The MPX4100API is a 6-SIP through-hole manifold-mount package (Case 867A) with the pressure port on the opposite side of the leads, while the MPXA4100A6T1 is an 8-pin SMT package designed for surface-mount reflow assembly. Both share the 20-105 kPa pressure range and 0.3-4.9 V ratiometric analog output, but they are NOT drop-in compatible - they require different PCB footprints.
How do I convert MPX4100API voltage output to pressure?
Per the NXP MPX4100 datasheet, the transfer function is Vout = VCC * (0.0118 * P + 0.247), where P is pressure in kPa and VCC is the supply voltage (typically 5.0 V). With VCC = 5.0 V, this yields Vout ≈ 0.0590 * P + 1.235. Rearranged: P (kPa) = (Vout - 1.235) / 0.0590. The 54 mV/kPa sensitivity applies at nominal supply.
What is the difference between MPX4100API and MPX5100API?
The MPX4100API measures 20-105 kPa while the MPX5100API measures 0-100 kPa (gauge to ~100 kPa absolute). Both are 6-SIP Case 867A manifold-mount packages from NXP with on-chip signal conditioning. The MPX5100 is generally preferred for higher-pressure automotive turbo applications. They are NOT pin-for-pin compatible because output transfer functions differ.
What kind of sensor is the MPX4100API and how does it work?
The MPX4100API is a piezoresistive absolute pressure sensor. It works by measuring strain in a silicon diaphragm using diffused Wheatstone-bridge piezoresistors; as intake-manifold pressure flexes the diaphragm, the bridge unbalances and produces a differential output proportional to pressure. On-chip signal conditioning amplifies, temperature-compensates, and calibrates the signal to a 0.3-4.9 V ratiometric analog output.

엔지니어링 참조 데이터: MPX4100API — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPX4100API when you need an AEC-Q100 qualified, calibrated, absolute pressure sensor for naturally aspirated engine MAP sensing or any 20-105 kPa atmospheric-pressure measurement where the integrated manifold-port nozzle simplifies manifold interface. The 6-SIP Case 867A package requires through-hole assembly, so choose the MPXA4100A6T1 for SMT-only reflow designs. Choose the MPX4100A if you do not need the manifold nozzle (basic SIP body) and want a slightly lower-cost option. Choose the MPX5100API if you need a wider 0-100 kPa gauge range for turbo applications. All three Case 867A variants share pin compatibility; verify the nozzle orientation against the datasheet mechanical drawing before final PCB layout to avoid reversed-output mounting.

대체품과의 비교

파라미터 이 제품 MPX4100AP MPX4100AP1 MPX4100A
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 6-SIP (Case 867A) 6-SIP (Case 867A) - same 6-SIP (Case 867A) - same 6-SIP (Case 867A) - same
Pressure Range 20 kPa to 105 kPa 20 kPa to 105 kPa 20 kPa to 105 kPa 20 kPa to 105 kPa
Output Voltage 0.3 V to 4.9 V 0.3 V to 4.9 V 0.3 V to 4.9 V 0.3 V to 4.9 V
Supply Voltage 5.0 V typical 5.0 V typical 5.0 V typical 5.0 V typical
Sensitivity 54 mV/kPa 54 mV/kPa 54 mV/kPa 54 mV/kPa
Manifold Port Nozzle Yes Yes Yes No (basic SIP body)
Automotive Grade AEC-Q100 AEC-Q100 AEC-Q100 AEC-Q100

주요 차별점

  • Manifold-port nozzle integrated in the package (vs MPX4100A)
  • Same-family pin compatibility with broader MPX4100 family (vs MPXA4100A6T1)
  • On-chip temperature compensation and factory calibration (vs MPX5100API)

설계 노트

Route the MPX4100API output through an anti-alias RC filter (typical 1 kΩ + 100 nF) before the ADC input to suppress ignition and motor-drive RF noise common in automotive environments. Place the filter within 10 mm of the sensor output pin to maximize noise rejection. Add a 100 nF ceramic bypass capacitor directly between VCC (pin 1) and GND (pin 3) of the sensor, with short traces to minimize supply-induced noise on the ratiometric output. Use a star-ground topology tying the sensor GND to the ADC reference ground to avoid ground loops.

The MPX4100API uses an O-ring sealed manifold port that mates with the intake manifold via a barbed or push-on fitting. The gel-coated silicon die is gravity-sensitive, so the sensor must be mounted with the port oriented vertically downward or as specified by NXP application note AN1668 to prevent gel migration that would degrade accuracy over the device lifetime. Do not expose the gel to direct airflow, oil, or fuel - the manifold cavity protects the die. Use a fluorosilicone O-ring rated for -40 °C to +150 °C to ensure sealing across the operating range.

Do not confuse the MPX4100API (Manifold Absolute Pressure, Case 867A SIP with nozzle) with the MPX4100A (basic SIP body without nozzle) or the MPXA4100A6T1 (8-pin SMT package). Only the MPX4100API and MPX4100AP share the same 6-SIP Case 867A manifold-port package and are drop-in compatible. The MPXA4100A6T1 has a different PCB footprint and cannot be substituted on the same board. Verify the manifold port orientation against the datasheet mechanical drawing before PCB layout, because inverted mounting will produce sign-reversed output.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Qualified
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

AEC-Q100 qualified by NXP for automotive under-hood applications. RoHS compliant per NXP product page. Lead-free reflow compatible.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPX4100API MPX4100API datasheet NXP MPX4100API pressure sensor 20-105 kPa absolute pressure sensor 6-SIP Case 867A MAP sensor MPX4100API automotive MAP sensor MPX4100API vs MPX4100AP MPX4100API drop-in replacement MPX4100API buy price stock what is the output voltage of MPX4100API MPX4100API pinout 6-SIP AEC-Q100 manifold absolute pressure sensor

관련 부품 & 용어

NXP Semiconductors Freescale Semiconductor MPX4100API MPX4100AP MPX4100AP1 MPX4100A MPXA4100A6T1 MAP sensor Manifold Absolute Pressure sensor absolute pressure sensor piezoresistive sensor Wheatstone bridge AEC-Q100 6-SIP Case 867A RoHS engine control unit ECU speed-density intake manifold HVAC altimeter barometric pressure automotive sensor on-chip signal conditioning
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기