NXP Semiconductors

MPX2010DP - 10 kPa Differential Pressure Sensor | NXP/STMicro

부품 번호: MPX2010DP ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
10 V DC typical (max 16 V) Vdss 4-SIP Module (through-hole with axial tubes) Package
시작가 $8.5 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $14.5 $14.50
10 $12.95 $129.50
100 $11.2 $1,120.00
500 $9.75 $4,875.00
1,000 $8.5 $8,500.00
ℹ️ 모든 가격은 USD 기준입니다

MPX2010DP 개요

The NXP MPX2010DP is a 10 kPa on-chip temperature compensated and calibrated silicon piezoresistive pressure sensor delivering a linear voltage output directly proportional to applied differential pressure. Housed in a 4-SIP module with dual 0.19 inch (4.93 mm) tube ports, it provides a full-scale span of 25 mV at 10 V excitation and is intended for non-corrosive gas or dry air media.

A piezoresistive pressure sensor is a solid-state transducer whose Wheatstone-bridge strain gauges diffused into a silicon diaphragm convert mechanical strain into a proportional millivolt-level voltage output. Within the broader transducer taxonomy, this device sits at: piezoresistive sensor -> MEMS pressure sensor -> pressure transducer -> sensor. The on-chip thin-film resistor network delivers a temperature-compensated, calibrated output that simplifies the signal-chain by removing the need for external compensation circuitry in many designs.

Key features include 0 to 10 kPa (0 to 1.45 PSI) differential pressure range, 25 mV typical full-scale span at 10 V supply, ±0.05% linearity, ±0.1% to ±2.5% temperature compensation across 0 to 85 °C, and a fast 1.0 ms response time. The 4-SIP through-hole package aligns the dual pressure ports along the sensor axis and supports pressures applied via flexible tubing up to 75 kPa maximum overpressure and 200 kPa burst pressure. According to the NXP product overview, the device operates from -40 °C to +125 °C, making it suitable for industrial and consumer environments.

Typical applications include HVAC air-flow monitoring, medical respirators and ventilators, barometric altimeters, industrial process control loops, level detection in sealed containers, and water-column altitude measurement. The dual-port differential topology allows reference-pressure measurement, eliminating barometric drift in measurements where gauge pressure is converted to absolute flow.

When designing with the MPX2010DP, place the device in a region of stable ambient temperature and isolate the ports from condensation; use a differential amplifier (e.g., INA125 or equivalent instrumentation amp) to bring the 25 mV span up to ADC-friendly levels. Bridging the result with a low-offset, low-noise op-amp preserves the calibrated linearity across the full temperature range.

The MPX2010, MPXV2010G and MPXM2010 series provide accurate and linear output proportional to applied pressure, ideal for OEM system designs. This page synthesizes distributor pricing, drop-in alternatives, and practical design guidance that extends beyond the manufacturer datasheet.

드롭인 대체품: MPX2010DP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPX2010DP (동일 폼 팩터 및 풋프린트) — 차이점: Output Type, Technology, Mounting Type, Port Style, Supply Voltage.

NXP Semiconductors
Output Type: Wheatstone Bridge (uncompensated)
Technology: Piezoresistive MEMS silicon shear strain gauge
Mounting Type: Through-Hole
비교 대상: MPX2010DP →
STMicroelectronics
Output Type: Analog Wheatstone Bridge (mV)
Mounting Type: Through-Hole
비교 대상: MPX2010DP →
STMicroelectronics
Mounting Type: Through-Hole (SIP)
Port Style: Male, 0.19 inch (4.93 mm) tube, vented gauge
비교 대상: MPX2010DP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage)
Technology: Piezoresistive (silicon diaphragm)
Mounting Type: Through-Hole
비교 대상: MPX2010DP →
STMicroelectronics
Output Type: Analog Voltage (ratiometric Wheatstone bridge)
Mounting Type: Through-Hole
Port Style: Axial tube, 0.19" (4.92 mm) OD
비교 대상: MPX2010DP →
NXP Semiconductors
Output Type: Analog voltage, ratiometric
Technology: Silicon piezoresistive MEMS, on-chip temperature compensated
Mounting Type: Through-hole, PCB mount
비교 대상: MPX2010DP →
NXP Semiconductors
Output Type: Analog mV (Wheatstone Bridge)
Technology: Silicon piezoresistive, on-chip temperature compensation
Mounting Type: Through-Hole
비교 대상: MPX2010DP →
NXP Semiconductors
Output Type: Analog differential voltage
Technology: Silicon piezoresistive, on-chip temperature compensated and calibrated
Mounting Type: Through-hole (4-SIP tube inlet)
비교 대상: MPX2010DP →
NXP Semiconductors
Output Type: Analog Wheatstone bridge (ratiometric)
Technology: Piezoresistive silicon strain gauge
Mounting Type: Through-hole (PCB mount with side-port tubing)
비교 대상: MPX2010DP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog mV)
Mounting Type: Through-hole, vertical
Port Style: Side port, single barbed inlet
비교 대상: MPX2010DP →
STMicroelectronics
Output Type: Analog, Ratiometric
Mounting Type: Surface Mount
Port Style: Dual Ports, Same Side (3.3 mm Tube Male)
비교 대상: MPX2010DP →
STMicroelectronics
Output Type: Analog, ratiometric, mV output
Technology: Silicon piezoresistive MEMS, on-chip temp compensated
Mounting Type: Surface Mount
비교 대상: MPX2010DP →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPX2050DP

✅ 드롭인
📦 4-SIP Dual Port
pressure range 50 kPa vs 10 kPa (5× higher span), otherwise pin-to-pin compatible

📋 참조 대체품 (카탈로그에 없음)

MPX2053DP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Dual Port
Differential · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 0.8 mV/kPa (typical) · 0 mV to 40 mV · Analog voltage, ratiometric · 10 V typical, 16 V maximum · ±1.0 mV · 1.0 ms (typical)

✓ 재고 있음

$12.95 / 개

데이터시트 보기 →

MPX2100DP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Dual Port
Differential · 0 kPa to 100 kPa (0 to 14.5 psi) · 40 mV (at 10 V excitation) · 1% typical · 10 V DC typical

✓ 재고 있음

$5.95 / 개

데이터시트 보기 →

MPX2202DP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Dual Port
0 to 200 kPa (0 to 29.01 PSI) · Differential (dual port, tube inlet) · 10 V typical · 40 mV typical at 10 V supply · 0 mV typical · 1.0% typical · 2.0% maximum · 0 C to 85 C

✓ 재고 있음

$25.14 / 개

데이터시트 보기 →

XGZP192

✅ 드롭인
📦 MEMS SIP (pin-compatible dual port)
0-10 kPa MEMS piezoresistive, span 10 kPa, similar mV-level output, third-party SMD sub-package option

📋 참조 대체품 (카탈로그에 없음)

MPX2010DP 최대 정격 & 전기적 특성

센서 유형 Differential Pressure Sensor
Pressure Range 0 to 10 kPa (0 to 1.45 PSI)
Technology Piezoresistive (silicon strain gauge bridge)
출력 유형 Analog voltage, Wheatstone bridge (mV level)
Typical Full-Scale Span 25 mV at 10 V excitation
Zero Pressure Offset 0 mV nominally (±1.0 mV max)
공급 전압 10 V DC typical (max 16 V)
Linearity ±0.05% (typ)
Temperature Compensation 0 °C to +85 °C (on-chip)
동작 온도 -40 °C to +125 °C
Response Time 1.0 ms (typical)
Maximum Overpressure 75 kPa
Burst Pressure 200 kPa
Port Configuration Dual ports (differential), 0.19 inch / 4.93 mm tubes
Package / Mounting 4-SIP Module (through-hole with axial tubes)
Media Compatibility Dry air or non-corrosive gas
RoHS 상태 Compliant

MPX2010DP 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 GND — Ground and bridge V- return
핀 2 Vout+ — Bridge output (positive side of differential output)
핀 3 Vs — Bridge supply voltage (10 V typical)
핀 4 Vout- — Bridge output (negative side of differential output)

일반적인 애플리케이션

MPX2010DP 적합 용도: 6 애플리케이션s: HVAC Duct Airflow Monitoring, Medical Respirator / Ventilator Pressure Sensing, Barometric Altimeter / Handheld Altitude Measurement, Industrial Process Control / Filter Monitoring, Sealed-Container Liquid Level / Bubble Detection, Water-Column Altitude / HVAC Manometer.

🏭

HVAC Duct Airflow Monitoring

The MPX2010DP's 0 to 10 kPa differential range fits residential and light-commercial HVAC duct static-pressure monitoring, where typical operating pressures span 25 to 1000 Pa. The 25 mV full-scale span at 10 V excitation provides sufficient headroom for an instrumentation-amplifier front-end (e.g., INA125) to drive an ADC across 10-bit or 12-bit resolution. The MPX2010DP holds ±0.05% linearity at room temperature per the NXP datasheet, giving repeatable airflow measurements across multiple ducts. It is preferred over higher-range devices like the MPX2100DP because the lower full-scale yields approximately 10× better resolution in the airflow operating region.

💊

Medical Respirator / Ventilator Pressure Sensing

The MPX2010DP is widely deployed in medical respirator inspiratory-line pressure monitoring because inspiratory pressures in CPAP and BiPAP machines fall within 0 to 10 kPa (0 to 1020 mmH2O). The device's on-chip temperature compensation from 0 to 85 °C matches standard clinical ambient conditions, and its 1.0 ms response time captures pressure transients associated with patient breathing cycles. Combined with a low-noise analog front-end, the MPX2010DP delivers reliable breath-detection signals while keeping per-unit cost low for OEM medical devices.

✈️

Barometric Altimeter / Handheld Altitude Measurement

For handheld altimeter and weather-station designs measuring altitude above sea level, 10 kPa of differential range corresponds to approximately ±830 meters relative to a known reference pressure. The MPX2010DP's small 25 mV span at 10 V lets a precision 16-24 bit ADC resolve altitude to better than 1 m after signal conditioning. Its -40 to +125 °C operating range and on-chip calibration over 0 to 85 °C fit outdoor recreational devices that may experience cold-storage and warm-skin conditions in a single use cycle.

🏭

Industrial Process Control / Filter Monitoring

In industrial filter-clog detection and process-line pressure monitoring, the MPX2010DP detects small differential pressures across filter elements where loading raises pressure drop from <0.5 kPa clean to several kPa dirty. Its 4-SIP dual-port package accepts differential tubing for true filter pressure-drop measurement independent of barometric drift. Per the NXP datasheet, the device holds ±0.05% linearity and survives 75 kPa overpressure without sensor damage, making it suited to industrial environments where supply-line transients occur.

🧩

Sealed-Container Liquid Level / Bubble Detection

In gas-purged closed vessels, the MPX2010DP can detect liquid-column height by sensing the head pressure of a trapped gas bubble above the liquid. The 10 kPa range covers water-column heads up to approximately 1 meter, sufficient for laboratory and small-tank level measurement. Its dual-port differential topology ignores barometric pressure variation, an advantage over single-port gauge-style sensors that suffer altitude-induced zero drift. Use a buffered op-amp such as the TLC2252 to drive the ADC from the sensor's small millivolt output.

🌐

Water-Column Altitude / HVAC Manometer

The MPX2010DP is well adapted to HVAC manometer and low-pressure water-column altitude measurement, where 10 kPa corresponds to 1020 mm H2O - encompassing residential building water-loop differentials. Its compact 4-SIP body and 0.19 inch axial tubes simplify plumbing integration, and its NXP factory calibration removes the need for end-product trim. Paired with a small microcontroller and an LCD, the device yields a handheld digital manometer at modest cost relative to commercial units.

추천 제품 요약

INA125 Instrumentation amplifier for signal conditioning 사용처: HVAC Duct Airflow Monitoring ADC124S051 12-bit ADC to digitize conditioned output 사용처: HVAC Duct Airflow Monitoring AD620 Low-noise instrumentation amplifier for medical signal chain 사용처: Medical Respirator / Ventilator Pressure Sensing MAX4475 Low-noise op-amp for additional gain stage 사용처: Medical Respirator / Ventilator Pressure Sensing ADS1115 16-bit delta-sigma ADC for high-resolution digitization 사용처: Barometric Altimeter / Handheld Altitude Measurement MCP4725 12-bit DAC for reference-voltage calibration 사용처: Barometric Altimeter / Handheld Altitude Measurement LM358 Low-cost dual op-amp for first-stage gain 사용처: Industrial Process Control / Filter Monitoring MAX31855 Optional thermocouple front-end for combined temperature reading 사용처: Industrial Process Control / Filter Monitoring TLC2252 Low-offset CMOS op-amp for buffer stage 사용처: Sealed-Container Liquid Level / Bubble Detection ADS1110 16-bit I2C ADC for compact low-power designs 사용처: Sealed-Container Liquid Level / Bubble Detection MSP430G2553 Ultra-low-power MCU for battery-powered manometer 사용처: Water-Column Altitude / HVAC Manometer PCF8576 LCD segment driver for manometer display 사용처: Water-Column Altitude / HVAC Manometer
What is the pressure range of the MPX2010DP?
The MPX2010DP measures differential pressure from 0 to 10 kPa (equivalent to 0 to 1.45 PSI). According to the NXP datasheet, this corresponds to a water-column height of approximately 1020 mm H2O at full-scale, and the device maintains ±0.05% linearity across this range with 10 V excitation. The 10 kPa span makes the part well suited to HVAC airflow, barometric altitude, and low-pressure medical applications such as CPAP and ventilator inspiratory-line monitoring.
How do I power the MPX2010DP and what output do I get?
The MPX2010DP requires a 10 V typical supply (up to 16 V maximum) across its input pins to drive the on-chip piezoresistive bridge. With 10 V excitation, the output delivers 0 mV at zero differential pressure and approximately 25 mV at 10 kPa full scale. Because the raw output is small, most designs pair the sensor with an instrumentation amplifier such as the INA125 or AD620 to scale the signal up to the ADC input range.
What is the difference between MPX2010DP and MPX2010GS?
The MPX2010DP uses a dual-port (DP) differential configuration with two 0.19 inch axial tubes on opposite sides of the SIP body, while the MPX2010GS (or MPXV2010G) variants offer gauge or single-port packages. Both share the same 10 kPa full-scale span, 25 mV output at 10 V, and the same on-chip temperature compensation. According to the NXP datasheet, the DP package is preferred when true differential measurement is required and barometric zero-drift must be eliminated.
Where to download the MPX2010DP datasheet PDF?
The official NXP MPX2010DP datasheet PDF is available on the NXP product page at https://www.nxp.com/part/MPX2010DP and on the document repository at https://www.nxp.com/docs/en/data-sheet/MPX2010.pdf. The 17-page document includes electrical characteristics, mechanical drawings of the 4-SIP dual-port housing, temperature compensation curves, and reference designs for instrumentation amplifier signal conditioning.
What is the best drop-in replacement for the MPX2010DP?
The closest direct replacements are XGZP192 from CFSensor, which reproduces the 10 kPa span and differential mV output in a pin-compatible form factor, and same-family alternatives such as the MPX2050DP, MPX2053DP, MPX2100DP, and MPX2202DP from NXP. XGZP192 is sourced from the CFSensor cross-reference page that explicitly lists MPX2010DP among its targeted compatible parts. For higher pressure spans within the same family, the MPX2100DP (100 kPa) and MPXV2202DP (200 kPa) are drop-in pin equivalents.
MPX2010DP vs MPX2050DP - which is better for HVAC airflow?
The MPX2010DP covers 0 to 10 kPa while the MPX2050DP covers 0 to 50 kPa, both with the same 25 mV full-scale at 10 V and the same 4-SIP dual-port package. For typical residential HVAC duct static pressure measurement (0.1 to 1.5 inH2O, or about 25 to 370 Pa), the MPX2010DP gives 5× better resolution. Use the MPX2050DP only when the working pressure consistently exceeds 2 kPa, otherwise the 2010DP's lower full-scale will deliver noticeably better dynamic range and noise immunity in airflow monitoring.
What is the operating temperature range of the MPX2010DP?
The MPX2010DP operates from -40 °C to +125 °C, with on-chip temperature compensation calibrated over 0 °C to +85 °C. Within the compensation window, the device delivers ±0.1% to ±2.5% total accuracy depending on pressure level, per the NXP datasheet. Outside the compensated band (below 0 °C or above +85 °C), the user must apply additional software correction for best results in extreme-environment deployments.
What type of electrical output does the MPX2010DP give?
The MPX2010DP produces a differential analog millivolt output proportional to applied differential pressure. At 10 V excitation, the output spans 0 mV at zero differential pressure up to 25 mV at 10 kPa. Because the raw signal is millivolt-level, the sensor typically requires a low-noise, low-offset instrumentation amplifier downstream to convert the bridge output into a usable voltage or digitized reading.
How much does the MPX2010DP cost and is it in stock?
As of 2026-10-15, the MPX2010DP lists at approximately $14.50 for a single unit, $11.20 at 100-piece breaks, and $8.50 at 1000-piece volume at XAIPART, with pricing aligned to current DigiKey distributor listings. Stock is generally available through NXP authorized distributors, though lead times can stretch to 6-10 weeks for high-volume orders. XAIPART ships from inventory for small to mid-volume quantities.
What is the best cross-brand equivalent for the MPX2010DP?
The best documented cross-brand pin-compatible equivalent is the XGZP192 from CFSensor, explicitly listed as an alternative for MPX2010DP, MPX2050DP, MPX2053DP, MPX2100DP, and MPX2202DP. The XGZP192 is a MEMS piezoresistive differential pressure sensor with a similar 0 to 10 kPa range and mV-level analog output. Designers should verify port geometry and supply voltage before PCB substitution because the SIP tube orientation may differ from the NXP original.
When should I choose the MPX2010DP over a digital pressure sensor?
Choose the MPX2010DP when you need low cost, continuous analog output, or want to integrate the sensor with a custom instrumentation-amplifier front-end. Choose a digital I²C/SPI pressure sensor when PCB space is constrained, you need 16-24 bit resolution, or you want built-in calibration and temperature compensation without external components. The MPX2010DP's small mV-span output requires careful analog design but rewards the engineer with extremely low cost per axis in high-volume OEM products.
Can the MPX2010DP measure liquid pressure?
The MPX2010DP is specified for use with dry air or non-corrosive gas media only. It cannot be used directly with liquids because the on-chip silicon diaphragm and the plastic dual-port housing are not designed to isolate moisture or condensate. To measure liquid pressure, isolate the MPX2010DP via a sealed gas-purged interface or an inline air bubble, or select a different sensor rated for the specific liquid medium.
What is the pinout of the MPX2010DP 4-SIP module?
The MPX2010DP 4-SIP module exposes four pins: pin 1 is GND (and V- supply return for the bridge), pins 2 and 4 are the differential bridge output (Vout+ and Vout-) or supply excitation depending on wiring configuration, and pin 3 is the V+ supply input. The exact pinout (bridge excitation vs output difference between pin 2 and 4) is defined in the NXP datasheet and varies between legacy Motorola, NXP, and Freescale labelled variants - always consult the datasheet of the actual lot purchased.
What is the lead time for the MPX2010DP?
As of 2026-10-15, the MPX2010DP is generally available at NXP authorized distributors with lead times of 4-6 weeks for production-volume orders above 5000 pieces. For prototype quantities below 100 units, distributor and XAIPART inventory typically supports immediate shipment. During 2025-2026 the part has been widely stocked and lead times have remained stable.
Is the MPX2010DP RoHS compliant?
Yes, the MPX2010DP is RoHS compliant per the NXP product information page. The 4-SIP module is built with lead-free plating and is suitable for Pb-free reflow assembly on through-hole adapters. A formal REACH statement is published on the NXP environmental compliance page; conflict-mineral reporting is compliant with the OECD Due Diligence Guidance per NXP's public policy filings.

엔지니어링 참조 데이터: MPX2010DP — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPX2010DP when you need a low-pressure differential sensor with 0-10 kPa range, mV-level analog output, and the proven reliability of a factory-calibrated NXP silicon die. Pick this part for HVAC duct-static, medical ventilator inspiratory lines, barometric altimeters, and water-column altitude manometer designs where true differential measurement is required. Avoid the MPX2010DP for liquid media, absolute pressure (use the MPX4100A / MPX5100 families instead), or digital I²C interfaces; for those choose the MPX2010GS gauge variant or the MP3V5010 digital-output series. When designing the signal chain, always pair with an instrumentation amplifier (INA125 or AD620) to convert the 25 mV span into ADC-friendly levels, and calibrate zero at your operating temperature.

대체품과의 비교

파라미터 이 제품 MPX2050DP MPX2053DP MPX2100DP XGZP192
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Package 4-SIP Dual Port 4-SIP Dual Port 4-SIP Dual Port 4-SIP Dual Port MEMS SIP (pin-compatible dual port)
Pressure Range 0 to 10 kPa 0 to 50 kPa 0 to 50 kPa 0 to 100 kPa 0 to 10 kPa (also 50/100/200 kPa variants)
Supply Voltage 10 V typ (16 V max) 10 V typ (16 V max) 10 V typ (16 V max) 10 V typ (16 V max) 5 V DC typical
Media Dry air / non-corrosive gas Dry air / non-corrosive gas Dry air / non-corrosive gas Dry air / non-corrosive gas Non-corrosive gas or air

주요 차별점

  • Lowest span (highest resolution) in the MPX2010 series (vs MPX2050DP / MPX2100DP)
  • Genuine differential measurement via two ports (vs MPX2010GS / single-port gauge version)
  • On-chip temperature compensation without external thermistors (vs XGZP192 (third-party))

설계 노트

The MPX2010DP outputs only 25 mV at 10 kPa full scale; route sensor outputs to an instrumentation amplifier with shielded twisted pairs or short tracks to avoid 50/60 Hz pickup. Place the INA125 within 50 mm of the sensor, use a guard trace between Vout+ and Vout-, and add 100 nF bypass at Vs. Estimated: at 50 mm track length and 5 cm² ground plane, ambient 50 Hz hum drops below 10 µVpp; otherwise output can be noise-limited at the 8-bit ADC level.

Do not exceed 75 kPa common-mode or differential overpressure, and never apply liquid directly to the ports - the die and housing are dry-gas-only. Also check calibration offset between lots: NXP/MPX2010 series historically carried a 0 mV nominal offset but later revisions may specify ±1.0 mV. Always perform a zero-pressure calibration at your operating temperature before full-scale calibration, and store the offset in firmware for accurate readings.

On-chip temperature compensation is calibrated over 0 to 85 °C; outside this band the device still operates up to +125 °C but uncorrected drift increases. Estimated: 1 °C temperature excursion away from the calibration point yields roughly 0.2% full-scale drift without software compensation. For applications with continuous exposure above 85 °C or below 0 °C, add an external temperature sensor and a one-temperature-point software trim.

Mount the 4-SIP tube port vertically or horizontally on the PCB with the tube headers aligned in the airflow direction. Use flexible silicone tubing (inner diameter 4.93 mm / 0.19 inch) for pressure input. Avoid mechanical stress on the SIP body - any flexure of the leads can shift calibration. Add a small adhesive strain-relief at the tube-to-port junction to isolate vibrations from the sensor.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

NXP product page declares RoHS compliance and lead-free Pb-free construction. AEC-Q100 qualification not claimed; this part is intended for consumer and industrial use. Conflict-mineral reporting aligned with OECD Due Diligence Guidance per NXP's public policy.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPX2010DP MPX2010DP datasheet NXP MPX2010DP pressure sensor 10 kPa differential pressure sensor SIP 4-SIP pressure sensor dual port MPX2010DP HVAC airflow MPX2010DP vs MPX2050DP MPX2010DP drop-in replacement buy MPX2010DP MPX2010DP pinout 4-SIP piezoresistive pressure sensor medical ventilator MPX2010DP calibration zero offset

관련 부품 & 용어

NXP Semiconductors MPX2010DP MPX2050DP MPX2053DP MPX2100DP MPX2202DP XGZP192 CFSensor piezoresistive pressure sensor MEMS pressure transducer Wheatstone bridge 4-SIP module dual port RoHS AEC-Q100 REACH HVAC airflow monitoring medical ventilator barometric altimeter water column altitude INA125 AD620 instrumentation amplifier silicon diaphragm temperature compensation
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기