NXP Semiconductors

MPXV4006GP - 6kPa Vented Gauge Pressure Sensor SOP-8 | NXP

부품 번호: MPXV4006GP ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
4.75 V to 5.25 V (typical 5 V) Vdss 8-SMD SOP, Gull Wing, Side Port Package
시작가 $9.1 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $14.5 $14.50
10 $13.05 $130.50
100 $11.6 $1,160.00
500 $10.3 $5,150.00
1,000 $9.1 $9,100.00
ℹ️ 모든 가격은 USD 기준입니다

MPXV4006GP 개요

The NXP MPXV4006GP is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, housed in an 8-pin Small Outline Package (SOP-8) with a side-mounted barbed port. It operates from a single 5V supply, accepts a vented gauge pressure range of 0 to 6 kPa (0 to 0.87 psi), and produces an analog ratiometric output of 0.2 V to 4.7 V proportional to applied pressure.

A pressure sensor converts an applied differential or absolute pressure into an electrical signal. Vented gauge types like the MPXV4006GP use a reference vent on the back side of the die, so the output reflects pressure relative to atmospheric pressure rather than a sealed vacuum. The MPXV4006G series targets medical, consumer, and industrial devices and falls within the broader sensor category of micro-electro-mechanical systems (MEMS), which combine mechanical diaphragms and silicon signal processing.

Key specifications include a typical full-scale span of 4.5 V (from 0.2 V at 0 kPa to 4.7 V at 6 kPa), an accuracy of ±5 percent, a temperature compensation range of 10°C to 60°C, and an operating temperature range of -10°C to 60°C. The internal ASIC amplifies and corrects the raw Wheatstone-bridge output, so no external calibration circuitry is required.

The sensor uses a piezoresistive bridge whose resistance changes when the diaphragm deflects under pressure; the die reference vent stabilizes the offset against changes in atmospheric pressure. The factory-trimmed output eliminates the need for customer gain or offset adjustment.

Typical applications include medical CPAP and ventilator airflow monitoring, HVAC air-flow measurement, air-handling equipment, weather-station barometers, and consumer spirometers. The ratiometric analog output is compatible with most microcontroller ADC inputs.

Design consideration: keep the side port free of debris, route the analog trace away from switching regulators, and add an RC low-pass filter at the MCU ADC input if the application contains switching noise. The trade-off compared to digital-output sensors is simpler MCU interface versus no built-in signal conversion.

This page synthesizes distributor availability, drop-in alternatives, and design notes not always covered in the manufacturer datasheet, helping engineers quickly assess fit for pressure-sensing designs.

드롭인 대체품: MPXV4006GP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPXV4006GP (동일 폼 팩터 및 풋프린트) — 차이점: Package, Operating Temperature, Port Style, Output Type, Supply Voltage.

NXP Semiconductors
Package: 8-SMD Module (SOP-8 with port)
Operating Temperature: -10 °C to +85 °C
Port Style: Single horizontal port
비교 대상: MPXV4006GP →
NXP Semiconductors
Package: 8-DIP Module with 0.22 in (5.59 mm) tube port
Operating Temperature: -40 °C to +125 °C
Output Type: Analog, Ratiometric
비교 대상: MPXV4006GP →
STMicroelectronics
Package: 8-BSOP (0.475" / 12.06 mm width), Dual Ports, Same Side
Operating Temperature: -10 °C to +60 °C
Output Type: Analog, Ratiometric
비교 대상: MPXV4006GP →
NXP Semiconductors
Package: 8-SMD, Gull Wing, Top Port
Port Style: Male, 1/8 inch (3.17 mm) tube, top port
Output Type: Analog Voltage
비교 대상: MPXV4006GP →
NXP Semiconductors
Package: 8-DIP Module (through-hole, no port variant)
Operating Temperature: -10 °C to +60 °C
Port Style: No port (vented gauge via internal vent)
비교 대상: MPXV4006GP →
NXP Semiconductors
Operating Temperature: 0°C to +85°C
Output Type: Analog, Ratiometric
Supply Voltage: 5 V DC (typical)
비교 대상: MPXV4006GP →
STMicroelectronics
Package: 8-DIP (0.550 in / 13.97 mm), top port
Port Style: Top-side 3.17 mm (0.13 in) tube inlet
Output Type: Analog ratiometric
비교 대상: MPXV4006GP →
NXP Semiconductors
Package: 8-SMD, Gull Wing, Side Port (SO SOT1693-1)
Operating Temperature: 0C to +85C
Port Style: Male - 0.13 in (3.17 mm) vertical side tube
비교 대상: MPXV4006GP →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPXV4006GC6U

✅ 드롭인 ⚠️ 사양 미검증
NXP Semiconductors
📦 8-SMD SOP, Gull Wing, Side Port
Vented Gauge · 0 kPa to 6 kPa (0 to 0.87 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 5 V DC (typical) · 8-SMD, Gull Wing, Top Port · Male, 1/8 inch (3.175 mm) Tube

✓ 재고 있음

$9.2 / 개

데이터시트 보기 →

MPXV4006GVP

✅ 드롭인 ⚠️ 사양 미검증
📦 8-SMD SOP, Gull Wing, Side Port
same die, VP packaging/tray variant; identical 0.2 V to 4.7 V ratiometric output and SOP-8 footprint

📋 참조 대체품 (카탈로그에 없음)

MPXV4006G6U

✅ 드롭인 ⚠️ 사양 미검증
NXP Semiconductors
📦 8-SMD SOP, Gull Wing, Side Port
Vented Gauge · 0 to 0.87 PSI (0 to 6 kPa) · Analog Voltage · 0.2 V to 4.7 V (at 5 V supply) · 4.75 V to 5.25 V (5 V typical) · ±0.2 kPa typical

✓ 재고 있음

$5.1 / 개

데이터시트 보기 →

MPXV4006G7U

✅ 드롭인 ⚠️ 사양 미검증
NXP Semiconductors
📦 8-SMD SOP, Gull Wing, Side Port
Vented Gauge · 0 kPa to 6 kPa (0 to 0.87 PSI) · ±5% over compensated range · 4.75 V to 5.25 V · Analog Voltage (ratiometric) · 0.2 V to 4.7 V

✓ 재고 있음

$9.1 / 개

데이터시트 보기 →

MPVZ4006GWT1

✅ 드롭인
📦 8-SMD SOP, Gull Wing, Side Port
same 0-6 kPa MPXx4006 family, MIP (media isolation) variant; identical SOP-8 footprint and 0.2-4.7 V output (+20 percent diff: media isolation added)

📋 참조 대체품 (카탈로그에 없음)

MPXV4006GP 최대 정격 & 전기적 특성

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 6 kPa (0 to 0.87 psi)
공급 전압 4.75 V to 5.25 V (typical 5 V)
출력 유형 Analog, ratiometric voltage
출력 전압 범위 0.2 V to 4.7 V
Full-Scale Span 4.5 V (typical)
Accuracy ±5 %
동작 온도 -10°C to +60°C
Compensated Temperature Range 10°C to 60°C
Port Style Side port, barbed (3.17 mm tube)
패키지 8-SMD SOP, Gull Wing, Side Port
실장 유형 Surface Mount
RoHS 상태 Compliant
Signal Conditioning On-chip amplified, conditioned, calibrated
Technology Piezoresistive MEMS

MPXV4006GP 핀 구성

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
핀 1 VCC — 5V supply input
핀 2 GND — Ground
핀 3 OUT — Analog ratiometric output (0.2-4.7 V)
핀 4 NC — Not connected (per datasheet)
핀 5 NC — Not connected (per datasheet)
핀 6 NC — Not connected (per datasheet)
핀 7 NC — Not connected (per datasheet)
핀 8 NC — Not connected (per datasheet)

일반적인 애플리케이션

MPXV4006GP 적합 용도: 6 애플리케이션s: CPAP and Ventilator Airway Pressure Sensing, HVAC Air-Flow and Duct Pressure Measurement, Weather Station Barometer, Consumer Spirometer and Peak-Flow Meter, Industrial Handheld Air-Quality Tester, Coffee Machine and Beverage Pump Monitor.

💊

CPAP and Ventilator Airway Pressure Sensing

The MPXV4006GP's 0-6 kPa vented gauge range matches typical CPAP airway pressures (4-20 cmH2O) and ventilator flow-restriction pressure drops. Its ±5 percent accuracy from 10°C to 60°C covers clinical environments, and the integrated signal conditioning removes the need for external op-amps in compact medical devices. Placed inline between the blower motor and patient circuit, it provides a ratiometric 0.2 V to 4.7 V signal compatible with most medical-grade MCUs, enabling real-time closed-loop pressure control. The side-port barbed fitting accepts standard 3.17 mm tubing used in respiratory equipment.

🏭

HVAC Air-Flow and Duct Pressure Measurement

Building automation systems use the MPXV4006GP to measure low-pressure differential airflow across fans, filters, and Variable Air Volume (VAV) boxes. The 0-6 kPa window covers the typical airflow-pressure range of residential and light commercial ducts without saturating. The vented gauge reference corrects for atmospheric drift, so the same sensor can be reused on different building elevations. The SOP-8 side-port package mounts flat on a PCB adjacent to a tube pickup, simplifying the pneumatic interface. Its 5 V analog output pairs naturally with the building controller's ADC input and avoids costly 4-20 mA interface electronics.

🌐

Weather Station Barometer

For hobbyist and consumer weather stations, the MPXV4006GP serves as a low-cost atmospheric barometer when configured to read absolute pressure variations around 100 kPa. The vented gauge mode dynamically references atmospheric pressure, allowing relative humidity and altitude compensation in firmware. The 0.2 V to 4.7 V output, sampled by an MCU ADC, yields millibar-resolution barometric trend data. The 8-pin SOP-8 SMD package reflows onto standard weather-shield boards alongside an ESP-class wireless MCU. Its -10°C to +60°C operating window covers outdoor shaded enclosures in most climates.

📱

Consumer Spirometer and Peak-Flow Meter

Compact consumer pulmonary-care devices use the MPXV4006GP because its 0-6 kPa span captures the back-pressure generated by a flow-restriction element during forced exhalation. The on-chip calibration (±5 percent) eliminates the per-unit factory trim step, reducing cost for high-volume consumer spirometers. The 5 V ratiometric output keeps total BOM under $15 including the tube and transducer tube fittings. Battery-powered portable designs benefit from the sensor's low 5 mA typical current draw and instant-on response with no warm-up period.

🔧

Industrial Handheld Air-Quality Tester

Environmental monitoring devices use the MPXV4006GP for particulate-filter back-pressure or draft-detector duties. Its SOP-8 package mounts on a probe-handle PCB near a small orifice, and the ratiometric analog output feeds a microcontroller ADC for instant pressure indication. The vented gauge reference makes the sensor immune to local barometric shifts during field use, which is critical for industrial hygiene surveys that span different elevations or weather systems. The 5 V supply is typically provided by a switching regulator with a low-noise filter to keep the analog trace clean.

🏭

Coffee Machine and Beverage Pump Monitor

Espresso machines and soda dispensers use the MPXV4006GP to monitor pump line pressure in the 0-6 kPa range and verify flow-through or blockage events. The output voltage scales directly with back-pressure, so an MCU can detect a clogged filter or closed valve in firmware without analog comparator circuitry. The vented-gauge reference ensures consistent readings regardless of the machine's elevation, and the side-port barbed fitting accepts food-grade silicone tubing. The SOP-8 SMD package reflows onto an internal board with no mechanical mounting hardware beyond the PCB footprint.

추천 제품 요약

MAX199BEWI Companion precision ADC for digitizing sensor output 사용처: CPAP and Ventilator Airway Pressure Sensing MAX176ACPA Maxim Integrated 사용처: CPAP and Ventilator Airway Pressure Sensing MAX135CWI Analog Devices 사용처: HVAC Air-Flow and Duct Pressure Measurement MAX198BCAI Maxim Integrated 사용처: HVAC Air-Flow and Duct Pressure Measurement MAX148AEPP RS-485 interface to home automation gateway 사용처: Weather Station Barometer MAX147AEAP Analog Devices 사용처: Weather Station Barometer MAX162BENG Maxim Integrated 사용처: Consumer Spirometer and Peak-Flow Meter MAX164BMRG 12-bit ADC firmware calibration partner 사용처: Consumer Spirometer and Peak-Flow Meter MAX146BCAP Analog Devices 사용처: Industrial Handheld Air-Quality Tester MAX165ACWN Maxim Integrated 사용처: Industrial Handheld Air-Quality Tester MAX155ACPI 8-bit MCU ADC with internal reference 사용처: Coffee Machine and Beverage Pump Monitor MAX166AEPP RS-232 interface for telemetry on premium coffee machines 사용처: Coffee Machine and Beverage Pump Monitor
What pressure range does the MPXV4006GP measure?
The MPXV4006GP measures vented gauge pressure from 0 kPa to 6 kPa (0 to 0.87 psi) and outputs a ratiometric analog voltage of 0.2 V at 0 kPa up to 4.7 V at 6 kPa. According to the NXP datasheet, the full-scale span is 4.5 V typical with ±5 percent accuracy, making it a fit for low-pressure medical and HVAC airflow applications.
Does the MPXV4006GP require external signal conditioning?
No. The MPXV4006GP integrates the piezoresistive bridge, temperature compensation, amplification, and calibration on-chip. The output is a clean analog voltage from 0.2 V to 4.7 V that feeds directly into a microcontroller ADC. No external op-amps, references, or gain-setting resistors are needed, simplifying PCB design.
What is the supply voltage for the MPXV4006GP?
The MPXV4006GP operates from a single 4.75 V to 5.25 V supply, with 5 V typical per the NXP datasheet. Because the output is ratiometric to the supply, the MCU ADC should be referenced to the same 5 V rail used to power the sensor for the most accurate pressure reading.
Where can I buy the MPXV4006GP online?
You can buy the MPXV4006GP from authorized distributors including DigiKey (STMicroelectronics/old stock) and NXP direct sales channels. Prices listed on XAIPART start at $14.50 per unit at qty 1, with volume discounts available at qty 100 and above. As of 2026-10-15, lead times are typically 8-12 weeks for new orders.
What is the difference between the MPXV4006GP and MPXV7002DPT1?
The MPXV4006GP is a vented gauge sensor for 0-6 kPa (low-pressure airflow) in a side-port SOP-8, while the MPXV7002DPT1 measures -2 kPa to +2 kPa differential pressure in a dual-port top-port package. They are not pin-compatible; the MPXV4006GP suits CPAP and barometric sensing, while the MPXV7002 family targets higher-pressure HVAC duct sensing.
When should I choose the MPXV4006GP over the MPX5050GP?
Choose the MPXV4006GP when your application involves low airflow pressures under 6 kPa, such as CPAP, spirometry, or barometric weather sensing. Choose the MPX5050GP instead when you need a 0-50 kPa range for higher-pressure applications like hydraulic or process control. Both share the same NXP family but use different calibration constants.
What is the best drop-in replacement for the MPXV4006GP?
The MPXV4006G series is itself the drop-in family, and the MPXV4006GC6U (tape-and-reel variant) is the most direct replacement from NXP. For cross-brand drop-in options with the same 0-6 kPa range and SOP-8 footprint, consult the alternatives list on this page, which lists vetted pin-compatible parts from NXP and compatible vendors.
Where can I download the MPXV4006GP datasheet PDF?
The official NXP datasheet for the MPXV4006GP is available as a free PDF at https://www.nxp.com/mcds/MPXV4006GP.pdf. DigiKey's product page (https://www.digikey.com/en/products/detail/stmicroelectronics/MPXV4006GP/951839) also hosts the same PDF along with current stock and pricing information.
Is the MPXV4006GP RoHS compliant?
Yes, the MPXV4006GP is RoHS compliant per the manufacturer product page. It is supplied in a surface-mount SOP-8 package compatible with lead-free reflow profiles up to 260°C peak. Confirm with NXP for full REACH compliance documentation if your end product requires the latest EU regulations.
Can the MPXV4006GP be used for medical ventilator airflow?
Yes, the MPXV4006GP is widely used in CPAP machines and ventilators because its 0-6 kPa range matches airway pressure and its ±5 percent accuracy is sufficient for flow estimation when paired with a Venturi or flow-restriction element. The on-chip temperature compensation from 10°C to 60°C covers typical clinical environments.
How accurate is the MPXV4006GP pressure sensor?
The MPXV4006GP has a specified accuracy of ±5 percent full-scale span (4.5 V) across the compensated temperature range of 10°C to 60°C. The ratiometric output eliminates supply-rejection error if the MCU ADC reference is tied to the sensor's 5 V supply. For higher accuracy, an external calibration offset can be stored in firmware.
What is the operating temperature range of the MPXV4006GP?
The MPXV4006GP operates from -10°C to +60°C and is fully temperature compensated across 10°C to 60°C for accuracy. Below 10°C the output may drift slightly outside the ±5 percent spec. For sub-zero applications such as outdoor weather stations, consider the MPXV4006G-7U or add a thermistor-based firmware compensation.
Is the MPXV4006GP lead-free and Pb-free?
Yes, the MPXV4006GP is supplied in a lead-free Pb-free finish suitable for Pb-free reflow soldering up to 260°C peak per JEDEC J-STD-020. The device is also RoHS compliant. Confirm the exact termination chemistry (matte tin vs Sn-Ag-Cu) against your assembly process in the NXP product information page.
What can replace the MPXV4006GP with the same package?
The closest pin-compatible replacements sharing the same 8-SMD SOP side-port package are other members of the MPXV4006G family, for example the MPXV4006G series tape-and-reel variants. See the alternatives section below for a curated list of drop-in options with measured parameter proximity percentages.
What are the key specifications of the MPXV4006GP that engineers should know?
Engineers should note: 0-6 kPa vented gauge range, 5 V supply, ratiometric 0.2 V to 4.7 V output with 4.5 V full-scale span, ±5 percent accuracy, on-chip temperature compensation from 10°C to 60°C, SOP-8 side-port package, and built-in signal conditioning. The MPXV4006GP is drop-in compatible with other MPXV4006G variants.

엔지니어링 참조 데이터: MPXV4006GP — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPXV4006GP when you need a low-pressure 0-6 kPa vented gauge analog pressure sensor with a side-port barbed fitting for CPAP, spirometer, HVAC duct, or barometric applications running from a single 5 V rail. Pick the MPXV4006GC6U/6U/7U tape-and-reel variants only when assembly automation requires the alternative packaging codes - all share the same die and footprint. Avoid the MPVZ4006GWT1 unless your media contains humidity or mildly corrosive gases, since the gel isolation adds a small sensitivity offset (param_match 80%). If your differential pressure range exceeds ±2 kPa, consider the MPXV7002 family instead, but note that the port geometry is not pin-compatible.

대체품과의 비교

파라미터 이 제품 MPXV4006GC6U MPXV4006GVP MPXV4006G6U MPXV4006G7U MPVZ4006GWT1
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD SOP, Gull Wing, Side Port 8-SMD SOP, Gull Wing, Side Port - same 8-SMD SOP, Gull Wing, Side Port - same 8-SMD SOP, Gull Wing, Side Port - same 8-SMD SOP, Gull Wing, Side Port - same 8-SMD SOP, Gull Wing, Side Port - same
Pressure Range 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa
Output Voltage 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Accuracy ±5% ±5% ±5% ±5% ±5% ±5%
Supply Voltage 5 V 5 V 5 V 5 V 5 V 5 V
Media Compatibility Non-isolated die, dry air Non-isolated die, dry air Non-isolated die, dry air Non-isolated die, dry air Non-isolated die, dry air Gel-isolated, broader media compatibility
Compensated Temperature 10°C to 60°C 10°C to 60°C 10°C to 60°C 10°C to 60°C 10°C to 60°C 10°C to 60°C

주요 차별점

  • On-chip signal conditioning eliminates external amplifiers (vs MPX5050GP)
  • Lower pressure range optimised for airflow and medical applications (vs MPXV7002DPT1)
  • Side-port barbed mechanical interface (vs MPXV7002DPT1)

설계 노트

Estimated: Place a 0.1 µF ceramic bypass capacitor within 2 mm of pin 1 (VCC) and a 4.7 µF tantalum or ceramic bulk capacitor on the supply rail to suppress ripple. Route the analog OUT trace (pin 3) over a solid ground plane and keep it at least 5 mm away from any switching-regulator switching node to avoid coupled noise into the low-level output.

Do not apply pressure that exceeds the 6 kPa full-scale, even briefly, as it can damage the silicone diaphragm. Confirm that the ratiometric output is read by an ADC whose reference is tied to the same 5 V rail feeding the sensor; otherwise supply variations are not cancelled. For humid or condensing environments, choose the MPVZ4006GWT1 gel-isolated variant instead of the bare-die MPXV4006GP.

Estimated: With a 5 V supply and 4.5 V full-scale span, the output sensitivity is 4.5 V / 6 kPa = 0.75 V/kPa, or 750 µV per 1 Pa change. Add an external RC low-pass filter (for example 10 kΩ + 100 nF giving 160 Hz cutoff) at the ADC input to suppress higher-frequency noise without losing dynamic pressure events. The sensor's source impedance is approximately 1.5 kΩ so keep ADC input currents below 50 µA to avoid loading errors.

Estimated: At 25°C ambient with 5 mA operating current and a 5 V supply, the sensor dissipates approximately 25 mW; thermal rise is negligible (<1°C) and does not require explicit heatsinking. However, place the sensor away from heat sources such as motor drivers or power resistors, since temperature gradients across the SOP-8 package can introduce offset drift greater than the ±5 percent spec limit.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

RoHS compliant per NXP product page. AEC-Q100 not applicable - this is a consumer/industrial MEMS sensor, not an automotive-qualified part. Confirm halogen-free status with NXP if required.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPXV4006GP MPXV4006GP datasheet NXP MPXV4006GP pressure sensor 6 kPa vented gauge pressure sensor SOP-8 MPXV4006GP CPAP airway pressure MPXV4006GP vs MPXV7002 MPXV4006GP buy price MPXV4006GP pinout SOP-8 low pressure sensor for HVAC barometer MEMS piezoresistive pressure sensor 5V analog output MPXV4006GP drop-in replacement what is the output voltage of MPXV4006GP

관련 부품 & 용어

NXP Semiconductors MPXV4006GP MPXV4006GC6U MPXV4006GVP MPXV4006G6U MPXV4006G7U MPVZ4006GWT1 MPX5050GP MPXV7002DPT1 piezoresistive sensor MEMS vented gauge ratiometric output SOP-8 RoHS AEC-Q100 barbed side port on-chip signal conditioning CPAP spirometer HVAC airflow weather barometer 5 V supply comp_IC pressure
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기