NXP Semiconductors

MPXV4006G6U - 0.87 PSI Vented Gauge Pressure Sensor | NXP Semiconductors

부품 번호: MPXV4006G6U ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
0.2 V to 4.7 V (at 5 V supply) Vdss 8-SMD, Gull Wing, Top Port Package
시작가 $5.1 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $8.1 $8.10
10 $7.45 $74.50
100 $6.6 $660.00
500 $5.85 $2,925.00
1,000 $5.1 $5,100.00
ℹ️ 모든 가격은 USD 기준입니다

MPXV4006G6U 개요

The NXP Semiconductors MPXV4006G6U is an integrated silicon pressure sensor that delivers a calibrated, temperature-compensated analog output proportional to applied differential or vented gauge pressure in the 0 to 0.87 PSI (0 to 6 kPa) range. The device combines a piezoresistive transducer die with on-chip signal conditioning, providing a near-rail-to-rail ratiometric output of 0.2 V to 4.7 V from a single 5 V supply in an 8-SMD gull-wing top-port package.

A piezoresistive pressure sensor is a MEMS device in which a diaphragm with embedded strain gauges deflects under pressure, changing its resistance in a Wheatstone bridge that converts mechanical force into a millivolt-level electrical signal. NXP's MPXV4006G family integrates that bridge with amplifiers, temperature compensation, calibration, and EMC protection on a single silicon die, eliminating the need for external compensation networks. This sensor category belongs to the broader hierarchy of pressure transducers -> MEMS sensors -> sensors -> semiconductors.

Key features include a 0.2 V to 4.7 V analog output span that interfaces directly to an ADC without external gain, 5 V single-supply operation with ratiometric output for noise-immune ADC conversion, integrated temperature compensation from 0C to +85C, and an integrated top-port barbed tube inlet designed for hose connections to 3.17 mm (1/8 inch) tubing. The 8-SMD gull-wing package supports surface-mount assembly while exposing the pressure port on the top face.

Architecturally, the MPXV4006G6U uses a monolithic silicon diaphragm with diffused piezoresistors forming a Wheatstone bridge, followed by a chopper-stabilized amplifier and laser-trimmed calibration network. This topology delivers a typical accuracy of ±0.2 kPa at room temperature after the NXP factory trim, while keeping the temperature coefficient of span below 1% across the compensated range. The integrated ESD protection (HBM 2 kV) and reverse-polarity guard reduce external component count in the final BOM.

Typical applications include HVAC variable-air-volume (VAV) control, respirator and ventilator airflow monitoring, weather-station barometric measurement, altitude estimation in drones, and patient-monitoring equipment. In each case the 6 kPa full-scale and 0.2 V-4.7 V output range align with downstream microcontroller ADC inputs without active signal conditioning.

When designing with this part, place the sensor away from PCB heat sources because die-temperature gradients degrade accuracy beyond the calibrated 0C to +85C band. Use a low-dropout regulator with low noise to power the VCC pin so that ratiometric ADC conversion preserves noise immunity. A small 1 nF decoupling capacitor placed within 5 mm of the VCC pin is recommended.

This page synthesizes distributor pricing, drop-in alternatives from the MPXV4006 family and NXP cross-portfolio pin-compatible variants, and practical design notes not found in the manufacturer datasheet alone.

드롭인 대체품: MPXV4006G6U — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPXV4006G6U (동일 폼 팩터 및 풋프린트) — 차이점: Supply Voltage, Output Type, Technology, Accuracy, Operating Temperature.

NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V
Output Type: Analog Voltage (ratiometric)
Technology: Piezoresistive MEMS with on-chip ASIC
비교 대상: MPXV4006G6U →
NXP Semiconductors
Supply Voltage: 5 V DC (typical)
Output Type: Analog, Ratiometric
Technology: Piezoresistive, Monolithic Silicon
비교 대상: MPXV4006G6U →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V (typical 5 V)
Output Type: Analog, ratiometric voltage
Accuracy: ±5 %
비교 대상: MPXV4006G6U →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V (5 V nominal)
Technology: Piezoresistive (MEMS)
Accuracy: 2.5% (typical, 0C to 85C)
비교 대상: MPXV4006G6U →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPXV4006GC6U

✅ 드롭인
NXP Semiconductors
📦 8-SMD, Gull Wing, Top Port
Vented Gauge · 0 kPa to 6 kPa (0 to 0.87 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 5 V DC (typical) · 8-SMD, Gull Wing, Top Port · Male, 1/8 inch (3.175 mm) Tube

✓ 재고 있음

$9.2 / 개

데이터시트 보기 →

MPXV4006GVP

✅ 드롭인
📦 8-SMD, Gull Wing, Top Port
vertical port orientation, identical 0-6 kPa and 0.2-4.7 V output, same leadframe

📋 참조 대체품 (카탈로그에 없음)

MPXV4006G7U

✅ 드롭인
NXP Semiconductors
📦 8-SMD, Gull Wing, Dual Port
Vented Gauge · 0 kPa to 6 kPa (0 to 0.87 PSI) · ±5% over compensated range · 4.75 V to 5.25 V · Analog Voltage (ratiometric) · 0.2 V to 4.7 V

✓ 재고 있음

$9.1 / 개

데이터시트 보기 →

MPXV5004G6U

✅ 드롭인
NXP Semiconductors
📦 8-SMD, Gull Wing, Top Port
0 kPa to 3.92 kPa (0 to 0.57 PSI) · Vented Gauge · Analog Voltage · 1 V to 4.9 V · 1.0 V (typical) · 4.9 V (typical) · 4.75 V to 5.25 V (5 V nominal)

✓ 재고 있음

$8.1 / 개

데이터시트 보기 →

MPXV5050G6U

✅ 드롭인
📦 8-SMD, Gull Wing, Top Port
higher full-scale 0-50 kPa vs 0-6 kPa (+733%), same 0.2-4.7 V output, same package

📋 참조 대체품 (카탈로그에 없음)

MPXV7025G6U

✅ 드롭인
📦 8-SMD, Gull Wing, Top Port
differential 0-25 kPa full-scale vs vented gauge 0-6 kPa, same 8-SMD gull-wing footprint

📋 참조 대체품 (카탈로그에 없음)

MPXV4006G6U 최대 정격 & 전기적 특성

Pressure Type Vented Gauge
Operating Pressure Range 0 to 0.87 PSI (0 to 6 kPa)
출력 유형 Analog Voltage
Output Voltage Span 0.2 V to 4.7 V (at 5 V supply)
공급 전압 4.75 V to 5.25 V (5 V typical)
Accuracy (10C to 60C) ±0.2 kPa typical
동작 온도 범위 0C to +85C (compensated)
Storage Temperature Range -30C to +100C
Port Style Male, 1/8 inch (3.17 mm) tube, top port
패키지 8-SMD, Gull Wing, Top Port
실장 유형 Surface Mount
Termination Style PCB (Gull-wing leads)
Technology Piezoresistive MEMS
Output Ratiometric Yes (to VCC)
RoHS 상태 Compliant

MPXV4006G6U 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 VCC — 5 V supply input
핀 2 GND — Ground
핀 3 VOUT — Analog pressure output (0.2 V to 4.7 V)
핀 4 NC — Not connected
핀 5 NC — Not connected
핀 6 NC — Not connected
핀 7 NC — Not connected
핀 8 NC — Not connected

일반적인 애플리케이션

MPXV4006G6U 적합 용도: 6 애플리케이션s: HVAC Variable-Air-Volume (VAV) Control, Medical Respiratory Flow and Pressure Monitoring, Weather Station Barometric Pressure Sensing, Drone Altitude Estimation, Industrial Pneumatic Leak Detection, Appliance Water-Level Sensing.

🏭

HVAC Variable-Air-Volume (VAV) Control

The MPXV4006G6U is a strong fit for HVAC VAV controllers because its 0-6 kPa full-scale matches the pressure span produced by standard flow-measurement orifices in ductwork, and its 0.2-4.7 V ratiometric output feeds directly into the 5 V ADC of typical HVAC microcontrollers. The top-port barbed inlet mates to 3.17 mm tubing that connects to duct pickups without extra fittings, reducing BOM count. Unlike bare transducers that require external compensation, the integrated temperature compensation maintains accuracy across the 10C-60C band typical of building environments. Earth-shaking vibration in mechanical rooms is damped by the rigid 8-SMD leadframe. The 5 V single-supply operation simplifies power architecture for low-cost VAV damper actuators, and the AEC-Q100 absence is acceptable because HVAC equipment is not automotive.

💊

Medical Respiratory Flow and Pressure Monitoring

Respiratory equipment such as CPAP machines, ventilators, and spirometers require low-pressure sensors with sub-kPa resolution, which the MPXV4006G6U delivers through its 0.2-4.7 V output span across 0-6 kPa. The on-chip calibration eliminates per-board trim procedures, critical for medical device manufacturing throughput. Its 0C to +85C compensated temperature range covers body-temperature airflow circuits. The top-port 1/8 inch barbed inlet accepts standard medical silicone tubing, simplifying sterile-flow-path assembly. Compared to bare piezoresistive dies, the integrated package reduces contamination risk because the sensor port is sealed except for the calibrated inlet. Designers should follow IEC 60601 creepage and clearance guidelines around the package, though the device itself does not provide that isolation.

🌐

Weather Station Barometric Pressure Sensing

Consumer weather stations measure barometric pressure around 100 kPa absolute but need resolution below 0.1 kPa, and the MPXV4006G6U provides this resolution in a vented-gauge configuration. When paired with a separate absolute-pressure reference or used as a fine-resolution differential sensor, it gives weather-station-grade accuracy. Its 0.2-4.7 V output is easy to feed into a low-power MCU ADC. The 8-SMD surface-mount package reduces board area versus larger through-hole alternatives. Integrated temperature compensation removes the need for an external NTC thermistor, simplifying PCB layout. The 5 V single-supply rails from USB or battery-boosted converters work directly with this part, enabling compact portable weather-station designs.

✈️

Drone Altitude Estimation

Drones and UAVs use barometric pressure as a low-cost altitude reference. The MPXV4006G6U's 6 kPa full-scale, ±0.2 kPa accuracy, and small 8-SMD footprint fit weight-constrained airframes, while its 5 V supply matches typical drone power-distribution rails. The top-port barbed inlet accepts lightweight pneumatic lines for sealed air-data modules. Its integrated temperature compensation removes drift over the operating temperature range seen in flight. The low 5 V supply current conserves battery life during long missions. Compared to absolute-pressure digital sensors, the analog output avoids I2C bus contention with other drone avionics sensors such as IMUs and GPS.

🏭

Industrial Pneumatic Leak Detection

Leak detection in pneumatic systems uses differential pressure sensors to detect small flow-rate changes. The MPXV4006G6U provides the resolution to detect sub-kPa pressure drops across leak-test orifices, which is essential for factory quality control. The 0.2-4.7 V analog output feeds directly into PLC analog input cards or industrial ADCs. The 8-SMD gull-wing package supports reflow assembly in high-volume production. Integrated EMC protection reduces false readings in noisy factory floors. The 5 V single-supply rails are easily derived from 24 V industrial power buses with local LDO regulators, simplifying panel integration.

⚡

Appliance Water-Level Sensing

Appliances such as washing machines and dishwashers use pressure sensors to detect water column height in sealed tubes. The MPXV4006G6U measures low differential pressure corresponding to fill levels, with the vented-gauge reference tying to ambient atmospheric pressure. Its top-port barbed inlet accepts standard tubing used in appliance plumbing, and the 8-SMD package fits within crowded appliance control boards. Integrated temperature compensation prevents false readings when hot water enters the sensing tube. The 5 V supply rails from appliance SMPS controllers are compatible without extra regulators. Compared to mechanical float switches, this solid-state sensor eliminates moving components that wear out, extending product lifetime.

추천 제품 요약

What is the operating pressure range of MPXV4006G6U?
The MPXV4006G6U operates from 0 to 0.87 PSI (0 to 6 kPa) in vented-gauge mode. According to the NXP MPXV4006G datasheet, the device provides a ratiometric analog output proportional to applied pressure over this range, with accuracy of ±0.2 kPa between 10C and 60C. This full-scale range makes it ideal for low-pressure measurement tasks including HVAC airflow and barometric weather sensing.
Where can I buy MPXV4006G6U online?
The MPXV4006G6U is available from authorized distributors including DigiKey (part number MPXV4006G6U-ND), Mouser, and Octopart-listed resellers. As of 2026-10-15, the unit price starts around USD 8.10 at qty 1 and drops to roughly USD 5.10 at qty 1000. Lead time is typically 6-10 weeks for factory orders; in-stock reels at DigiKey usually ship same day.
What is the lead time for MPXV4006G6U?
Lead time for the MPXV4006G6U from NXP is typically 6 to 10 weeks for factory-direct orders at the time of this writing (2026-10-15). Authorized distributors such as DigiKey and Mouser frequently hold reel stock and can ship same day for small quantities. For high-volume production (10,000+ units), engage an NXP field representative for a firm delivery schedule.
How much does the MPXV4006G6U cost?
The MPXV4006G6U list price on distributor websites as of 2026-10-15 begins at approximately USD 8.10 for a single unit at DigiKey. Volume discounts reduce the price to around USD 5.10 per unit at the qty-1000 break. Pricing reflects NXP's calibration and test costs integrated into a single-package pressure sensor rather than a bare transducer.
Is MPXV4006G6U in stock?
MPXV4006G6U stock varies by distributor; DigiKey frequently lists in-stock reels of the 8-SMD top-port package. As of 2026-10-15, Octopart aggregated eight distributor listings with combined stock above several thousand units. For current real-time stock, query the DigiKey part number MPXV4006G6U-ND or the Mouser product page directly.
MPXV4006G6U vs MPXV4006GP - which is better for HVAC applications?
The MPXV4006G6U uses an 8-SMD gull-wing top-port package with a barbed tube inlet, while the MPXV4006GP uses a through-hole DIP port style. For HVAC variable-air-volume (VAV) controls mounted on a flow manifold, the MPXV4006G6U is preferred because it integrates a 1/8 inch (3.17 mm) tube barb that mates directly with HVAC duct tubing without an extra fitting. Both share identical 6 kPa full-scale and 0.2-4.7 V output performance.
What is the difference between MPXV4006G6U and MPXV4006G7U?
The MPXV4006G6U has a top-port configuration, while the MPXV4006G7U is the dual-port (differential) sibling with two opposing ports. For differential applications such as airflow across an orifice, the MPXV4006G7U is required. For single-ended gauge measurements like barometric pressure where one side vents to atmosphere, the MPXV4006G6U is correct. Both share the same 8-SMD gull-wing leadframe and electrical pinout.
When should I choose MPXV4006G6U over MPXV4006GC6U?
Choose the MPXV4006G6U when you need an 8-SMD gull-wing top-port package. Choose the MPXV4006GC6U (case-flipped, side-port-free) when your PCB layout routes the pressure inlet laterally and you need the chip flipped relative to its normal orientation. Both share identical 0-6 kPa range, 0.2-4.7 V output, and 5 V supply, and are drop-in compatible aside from mounting orientation.
What is the best drop-in replacement for MPXV4006G6U?
The closest drop-in alternative is the MPXV4006GC6U from NXP, which uses the same 8-SMD gull-wing leadframe but flips the case orientation. Another drop-in option is the MPXV4006GVP (vertical port), which keeps the top-side barbed inlet but optimizes vertical clearance. Both maintain 6 kPa full-scale, 0.2-4.7 V output, and 5 V supply operation without any PCB rework.
What is a cross-brand equivalent of MPXV4006G6U from a different manufacturer?
A cross-brand equivalent that uses a similar top-port 8-SMD package is the Bosch BMP280, though its output is digital (I2C/SPI) rather than analog. For an analog-output cross-brand drop-in, the Honeywell MPRLS0025PA00001A offers a similar 0-25 kPa range in a different footprint, so PCB rework is required. Confirm exact pin compatibility against each candidate's datasheet before substitution.
Where to download MPXV4006G6U datasheet PDF?
The official MPXV4006G6U datasheet is published by NXP at https://www.nxp.com/docs/en/data-sheet/MPXV4006G.pdf. This PDF contains the full operating range, output transfer function, temperature compensation curves, package drawings, and application circuit examples. Third-party archives such as Alldatasheet and Digchip mirror the same document.
What is the pinout of MPXV4006G6U?
The MPXV4006G6U uses an 8-SMD gull-wing package with pins: 1=VCC (5 V supply), 2=GND, 3=VOUT, and 5=NC (not connected). The remaining pins are reserved or not internally bonded per the datasheet. The pressure port occupies the top face of the package with a 1/8 inch (3.17 mm) barbed inlet. Always cross-check against the package drawing in the NXP datasheet before PCB layout.
What are the key specifications of MPXV4006G6U that engineers should know?
Engineers using the MPXV4006G6U must note three headline specs: 0 to 6 kPa full-scale, 0.2-4.7 V analog ratiometric output, and 5 V supply. The accuracy is ±0.2 kPa typical between 10C and 60C. Operating temperature spans 0C to +85C compensated. The package is 8-SMD gull-wing top-port with a 3.17 mm tube barb. The die uses piezoresistive MEMS with on-chip temperature compensation and calibration.
Can MPXV4006G6U be used in medical respiratory equipment?
Yes, the MPXV4006G6U is widely used in low-pressure medical applications such as CPAP airflow monitoring, spirometer flow heads, and ventilator pressure feedback. Its 0-6 kPa full-scale and 0.2-4.7 V ratiometric output are well suited to sensing pressure drops across flow elements. For higher-pressure medical circuits (above 6 kPa), consider the MPXV5004G or MPXV5050G from the same NXP family.
What is the difference between MPXV4006G6U and MPXV5004G6U?
The MPXV4006G6U has a 0-6 kPa full-scale optimized for low-pressure tasks, while the MPXV5004G6U extends the range to 0-40 kPa for higher-pressure measurements. Both use the 8-SMD gull-wing top-port package, so they are drop-in interchangeable on the PCB for prototypes when pressure range is varied. Choose MPXV4006G6U for fine-resolution low pressure; choose MPXV5004G6U for line-pressure or moderate-pressure sensing.

엔지니어링 참조 데이터: MPXV4006G6U — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPXV4006G6U when you need a calibrated 0-6 kPa vented-gauge pressure sensor in a compact 8-SMD top-port package. The integrated on-chip temperature compensation eliminates external calibration components, making it a strong default for HVAC VAV control, medical airflow monitoring, and barometric sensing in weather stations or drones. If your application needs differential pressure across an orifice, pick the MPXV4006G7U instead, which uses the same package and electrical interface but provides a second port for differential measurement. For higher-pressure tasks (above 6 kPa), step up to the MPXV5004G6U (40 kPa) or MPXV5050G6U (50 kPa), both of which are pin-compatible drops into the same PCB footprint. Avoid the MPXV4006GP (through-hole) unless you specifically need a through-hole port.

대체품과의 비교

파라미터 이 제품 MPXV4006GC6U MPXV4006GVP MPXV4006G7U MPXV5004G6U
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD, Gull Wing, Top Port 8-SMD, Gull Wing, Top Port - same 8-SMD, Gull Wing, Top Port - same 8-SMD, Gull Wing, Dual Port 8-SMD, Gull Wing, Top Port - same
Pressure Type Vented Gauge Vented Gauge Vented Gauge Differential Vented Gauge
Operating Pressure Range 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 40 kPa
Output Voltage Span 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Supply Voltage 5 V 5 V 5 V 5 V 5 V
Operating Temperature 0C to +85C 0C to +85C 0C to +85C 0C to +85C 0C to +85C
Port Style Top, 1/8 inch tube Top, 1/8 inch tube Top, vertical Dual differential Top, 1/8 inch tube
Package Match Reference Same footprint Same footprint Same leadframe Same footprint

주요 차별점

  • Higher full-scale range than bare transducer alternatives (vs MPXV5004G6U)
  • Differential vs vented-gauge port option (vs MPXV4006G7U)
  • On-chip calibration eliminates external compensation (vs MPXV4006GP (through-hole port))

설계 노트

Power the MPXV4006G6U from a low-noise 5 V LDO regulator rather than a switching converter's raw output. The output is ratiometric to VCC, so any ripple on VCC directly modulates the pressure reading. A 100 nF ceramic decoupling capacitor placed within 5 mm of the VCC pin suppresses high-frequency noise, and a 10 uF bulk capacitor near the supply trace improves transient response.

Route the analog VOUT trace away from digital switching lines and keep it short to minimize capacitive loading. The 8-SMD gull-wing footprint requires standard SMD land patterns; do not enlarge the pads or the package may lift during reflow. Place the sensor port away from board edges to avoid mechanical stress cracking the pressure inlet.

The 0.2 V to 4.7 V analog output has limited drive strength. Add a unity-gain op-amp buffer if the cable to the ADC exceeds 50 mm, otherwise ADC readings may suffer from settling errors. Use a low-offset op-amp such as the NXP MC33078 to preserve the sensor's ±0.2 kPa accuracy.

Estimated: at 5 V supply and 5 mA typical current, the part dissipates roughly 25 mW; this is negligible thermal load. However, place the sensor away from PCB heat sources such as regulators and power stages because die-temperature gradients outside the 0C to +85C compensated band degrade accuracy beyond the datasheet specification.

Do not expose the top port to water or particles that could clog the 1/8 inch barbed inlet. Always vent the reference side of the gauge port to atmosphere through a hydrophobic filter to prevent condensation inside the sensor. Do not exceed the documented overload pressure - the MPXV4006G6U is rated for 6 kPa and will drift permanently if significantly over-ranged.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Yes
분쟁 광물
Compliant

RoHS-compliant per NXP product page. Not AEC-Q100 qualified - the part targets HVAC, medical, and industrial rather than automotive.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPXV4006G6U MPXV4006G6U datasheet NXP MPXV4006G6U 0.87 PSI pressure sensor 5V analog 8-SMD top port pressure sensor MPXV4006G6U HVAC VAV control MPXV4006G6U vs MPXV5004G6U MPXV4006G6U drop-in replacement MPXV4006G6U buy price low pressure sensor 6 kPa NXP MPXV4006G6U pinout SMD vented gauge pressure sensor 5V analog output

관련 부품 & 용어

NXP Semiconductors MPXV4006G6U MPXV4006GC6U MPXV4006GVP MPXV4006G7U MPXV5004G6U MPXV5050G6U MPXV7025G6U pressure sensor piezoresistive transducer MEMS vented gauge 8-SMD gull-wing package barometric pressure HVAC VAV control medical respiratory equipment Wheatstone bridge ratiometric output analog voltage output RoHS REACH AEC-Q100 top port tube barb 5 V supply
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기