OPA336PA - 20uA Low-Power CMOS Op Amp | Texas Instruments
부품 번호: OPA336PA ✓ 활성OPA336PA 개요
A CMOS operational amplifier is a voltage-controlled, differential-input amplifier using complementary MOS transistors. It provides voltage gain, filtering, buffering, and signal conditioning while operating from a single positive supply. The OPA336 belongs to the microAmplifier family and is positioned for portable, industrial, and instrumentation circuits where low supply current, rail-to-rail output behavior, and low input bias current are important. Its common-mode input range extends to the negative supply, supporting systems that operate from 2.1V to 5.5V.
Key features of the OPA336PA include a 20uA quiescent current per amplifier, 125uV maximum offset voltage, 1pA input bias current, and 115dB open-loop gain. The output is rail-to-rail and swings to within 3mV of the supply rails with a 100kohm load. These characteristics make the device useful in battery-powered sensor interfaces, current-loop measurements, low-level signal conditioning, and precision analog systems.
The OPA336 series uses CMOS input and output stages to provide low power consumption and high input impedance. Its 100kHz gain-bandwidth product is sufficient for many low-frequency measurement and control paths. Because the amplifier operates from a single supply, the negative common-mode range reaching the negative rail is valuable for unipolar sensor systems, where signal voltages can approach ground without requiring a negative supply.
Typical applications include portable electrochemical sensors, biomedical instrumentation, battery-powered monitors, low-current transducers, and low-power signal-conditioning modules. The low input bias current minimizes error when the source resistance is high, while the small quiescent current helps preserve battery capacity. The rail-to-rail output improves usable signal range in compact single-supply systems.
When designing around the OPA336PA, check input and output common-mode limits, bias-current error, capacitive-load stability, and the voltage drop across the output when driving heavier loads. Place bypass capacitors close to the supply pins and keep sensitive input routing short to minimize leakage and coupling. The 8-pin PDIP package is suitable for through-hole prototypes and legacy industrial equipment, although modern compact designs may require an alternative package option.
This product page combines the manufacturer’s operating characteristics with engineering guidance covering application fit, pin-compatible alternatives, parameter comparisons, and practical circuit implementation considerations.
드롭인 대체품: OPA336PA — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: OPA336PA (동일 폼 팩터 및 풋프린트) — 차이점: Open-Loop Gain, Quiescent Current.
OPA336P
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →OPA336PAG4
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
OPA336PA 최대 정격 & 전기적 특성
| Amplifier Type | Single operational amplifier |
| Technology | CMOS |
| Number of Channels | 1 channel |
| Minimum Supply Voltage | 2.1 V |
| Maximum Supply Voltage | 5.5 V |
| Supply Type | Single supply |
| 대기 전류 | 20uA per amplifier |
| Maximum Offset Voltage | 125uV |
| Typical Input Bias Current | 1pA |
| Open-Loop Gain | 115dB |
| Gain-Bandwidth Product | 100kHz |
| Output Swing | Within 3mV of the supplies at 100kohm load |
| Common-Mode Input Range | Extends to the negative supply |
| 출력 유형 | Rail-to-rail |
| 패키지 | 8-pin PDIP |
| 실장 유형 | Through-hole |
OPA336PA 핀 구성
| 핀 1 | NC — Not connected |
| 핀 2 | IN- — Inverting input |
| 핀 3 | IN+ — Non-inverting input |
| 핀 4 | V- — Negative supply |
| 핀 5 | NC — Not connected |
| 핀 6 | OUT — Output |
| 핀 7 | V+ — Positive supply |
| 핀 8 | NC — Not connected |
일반적인 애플리케이션
OPA336PA 적합 용도: 6 애플리케이션s: Battery-Powered Sensor Interface, Portable Medical Monitoring, Low-Current Transducer Conditioning, Industrial Process Monitoring, Low-Leakage Current Measurement, Low-Power Data Acquisition.
Battery-Powered Sensor Interface
The OPA336PA fits battery-powered sensor interfaces because its 20uA per-amplifier quiescent current limits standby consumption, while its 1pA typical input bias current reduces loading on high-impedance sensors. Operation from a single supply as low as 2.1V supports compact energy-harvesting and portable measurement systems. The common-mode input range extending to the negative supply also allows signals near ground to be amplified without adding a negative rail. In a typical circuit, the amplifier buffers or conditions a sensor output before a converter or controller samples it. Designers should still budget for load current, sensor leakage, and the energy consumed by external filtering components.
추천
Portable Medical Monitoring
The OPA336PA is appropriate for portable medical monitoring because its low 20uA per-amplifier supply current supports battery-operated instruments and its 1pA typical input bias current minimizes disturbance to high-impedance bio-sensing paths. The 125uV maximum offset voltage supports low-level signal conditioning, while the 115dB open-loop gain provides useful amplification for sensor-amplifier stages. A typical implementation places the device close to the sensor connector and uses it to amplify a weak differential or single-ended signal before filtering and digitization. Medical designs require appropriate signal isolation, protection, leakage evaluation, and validation for the intended measurement function.
추천
Low-Current Transducer Conditioning
OPA336PA suits low-current transducer conditioning because its 1pA typical input bias current creates less error with high-value source resistors, and its 20uA quiescent current keeps instrumentation power requirements modest. The 100kHz gain-bandwidth product is appropriate for slowly varying or low-frequency measurement signals rather than wideband waveforms. Designers can use the amplifier in a non-inverting or transimpedance topology, provided the selected feedback network remains compatible with the amplifier’s operating range. The rail-to-rail output provides useful headroom at low supply voltage, although output loading can increase supply current and reduce the benefit of the low-power architecture.
추천
Industrial Process Monitoring
The OPA336PA can support industrial process-monitoring circuits where low power, high input impedance, and single-supply operation are valuable. Its common-mode input range extends to the negative supply, helping process sensors produce signals close to ground, while the 125uV maximum offset voltage supports low-level amplification. The device can condition the output of a resistive or current-based sensor before an ADC input. Industrial implementation should include transient protection, appropriate grounding, and verified noise immunity around motors, relays, and switching converters. The 100kHz bandwidth is suitable for many slowly changing process variables but not for high-speed waveform monitoring.
추천
Low-Leakage Current Measurement
OPA336PA is well suited to current measurement because its 1pA typical input bias current reduces the measurement error contributed by the amplifier when the shunt or sensor impedance is high. The 115dB open-loop gain supports accurate closed-loop amplification, and the single-supply operation simplifies portable instrumentation. In a transimpedance amplifier, the feedback resistor and compensation capacitor must be selected around the device’s 100kHz gain-bandwidth product and stability requirements. Low bias current alone does not eliminate errors from resistor tolerance, input leakage, contamination, or dielectric absorption, so the complete measurement chain must be evaluated as a system.
추천
Low-Power Data Acquisition
OPA336PA fits low-power data-acquisition front ends that operate from a 2.1V to 5.5V single supply. Its 20uA per-amplifier quiescent current reduces consumption in portable acquisition systems, while the rail-to-rail output can use much of the available supply range. The amplifier can condition a sensor before conversion by an ADC or energy-harvesting supply. Input filtering, output settling, and ADC acquisition timing should be checked together because the amplifier bandwidth is 100kHz. A common-mode range extending to the negative rail simplifies zero-centered unipolar sensor measurements, although system grounding must remain clean to avoid converting return-path noise into measurement error.
추천
엔지니어링 참조 데이터: OPA336PA — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | OPA336P | OPA336PAG4 |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin PDIP | 8-pin PDIP - same | 8-pin PDIP - same |
| Amplifier Type | Single operational amplifier | Single operational amplifier | Single operational amplifier |
| Minimum Supply Voltage | 2.1 V | 2.1 V | 2.1 V |
| Maximum Supply Voltage | 5.5 V | 5.5 V | 5.5 V |
| Quiescent Current | 20uA per amplifier | 20uA per amplifier | 20uA per amplifier |
| Maximum Offset Voltage | 125uV | 125uV | 125uV |
| Input Bias Current | 1pA typical | 1pA typical | 1pA typical |
| Open-Loop Gain | 115dB | 115dB | 115dB |
| Gain-Bandwidth Product | 100kHz | 100kHz | 100kHz |
주요 차별점
- Very low amplifier quiescent current (vs OPA336P)
- Low input bias for high-impedance signals (vs OPA336PAG4)
- Single-supply rail-to-rail operation (vs OPA336P)
설계 노트
Place the supply bypass capacitor close to the OPA336PA V+ and V- pins, with a short ground path and minimal loop area. If the device is several centimeters from the supply source, add a second smaller capacitor at the pins to suppress high-frequency supply noise. Keep the amplifier ground return continuous and avoid routing sensitive input traces directly beside digital clocks, switch-node copper, or inductor connections.
High-impedance input traces can collect leakage, contamination, and capacitive pickup because the OPA336PA operates with 1pA typical input bias current. Keep feedback resistors close to the amplifier, avoid long exposed high-impedance nodes, and use guarding where practical. For transimpedance designs, calculate the feedback capacitance with the 100kHz gain-bandwidth product rather than relying only on a generic transimpedance formula.
Do not assume that a rail-to-rail output reaches the positive supply under every load condition. The stated 3mV output margin applies with a 100kohm load, so heavier loads can require additional output headroom. Also verify that the input and output remain inside the operating ranges at minimum supply voltage, especially when using gain near the positive rail or driving a capacitive load.
Estimated: at a 3.0V supply and 20uA quiescent current, no-load supply power is 60uW. Actual consumption also includes output-current demand and external circuit losses, so use 60uW as the amplifier-only baseline rather than a complete battery-life figure. Account for the load, sensor current, voltage regulator efficiency, and leakage over the intended operating mode when sizing the power source.
규정 준수 정보
The OPA336PA is an operational amplifier rather than an automotive-qualified component. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation from the manufacturer’s current product documentation.