PD-9506GC - 6-Port 60W BT PoE Midspan | Microchip Technology
부품 번호: PD-9506GC ⚠ 최종 구매| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $695 | $695.00 |
| 10 | $660.25 | $6,602.50 |
| 25 | $625.5 | $15,637.50 |
| 50 | $590.75 | $29,537.50 |
| 100 | $556 | $55,600.00 |
PD-9506GC 개요
A PoE midspan is a network appliance that sits between a non-PoE Ethernet switch and PoE-powered end terminals, injecting DC power onto the spare or data pairs of standard TIA/EIA-568 cabling without requiring replacement of the existing switch. Within the broader power-management taxonomy, the PD-9506GC belongs to the Power Sourcing Equipment (PSE) category of midspans, which itself sits above simple PoE splitters and below full PoE-enabled switches in Ethernet-power deployment hierarchies.
Key features include support for all four 802.3bt power classes (up to Class 8, 71 W minimum at PD), 55 V output voltage at the load, Gigabit data-rate transparency, and built-in Network Management System (NMS) capability. The unit performs full 2-event and 4-event physical-layer classification, ensuring backward compatibility with legacy 802.3af (15.4 W) and 802.3at (30 W) PDs while enabling new high-power installations.
Architecturally, the PD-9506GC uses an internal high-efficiency AC/DC power supply coupled with per-port detection, classification, and current-limiting circuitry. The chassis implements over-current, over-voltage, and thermal protection, and LED indicators provide visual port status and fault diagnostics. All six ports feed power over both the spare pairs and the data pairs (mode A + mode B), ensuring interoperability with the widest range of PD implementations.
Typical applications include ceiling-mounted Wi-Fi 6E/7 access points in enterprise offices, pan-tilt-zoom surveillance cameras in logistics and parking facilities, IP intercoms and access-control readers at building entrances, and digital signage kiosks. The 60 W per-port headroom also supports emerging USB-C-over-Ethernet thin clients and small-form-factor PCs powered solely through structured cabling.
When integrating the PD-9506GC, place the unit in a ventilated 19-inch rack or shelf-mount location because the power supply dissipates up to ~480 W at full 60 W x 6 load. Use only Cat5e or higher cabling, and budget an additional ~0.5 A per port for inrush spikes during PD classification. Microchip recommends pairing with their PD-9606GC for new deployments as the product replacement path.
This page synthesizes distributor pricing tiers, verified drop-in alternatives from the same PD-95xxGC family, side-by-side comparisons, and practical design notes that are not found in the manufacturer datasheet alone.
드롭인 대체품: PD-9506GC — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: PD-9506GC (동일 폼 팩터 및 풋프린트) — 차이점: Compliance, Mounting, Network Management, Output Voltage, PoE Standard.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
PD-9606GC/AC-US
✅ 드롭인✓ 재고 있음
$665.3 / 개
데이터시트 보기 →PD-9512GC
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
PD-9524GC
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
PD-9506GC/AC-US
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
PD-9506GC/AC-UK
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
PD-9506-10GC
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
PD-9506GC 최대 정격 & 전기적 특성
| Product Type | PoE Midspan Injector |
| Number of Ports | 6 |
| Output Power per Port | 60 W |
| Total Max Output Power | 360 W |
| 출력 전압 | 55 V DC |
| PoE Standard | IEEE 802.3bt Type 3 / Type 4 |
| Backward Compatibility | IEEE 802.3af / 802.3at |
| 데이터 속도 | 10/100/1000 Mbps |
| Data Pass-through | Yes (transparent) |
| Input Power | 100-240 V AC, 50/60 Hz |
| Network Management | Yes (NMS) |
| 동작 온도 | 0 C to 40 C |
| AC Power Cord Options | US / UK / EU / AC variants |
| Mounting | 1U rack / shelf-mount |
| Compliance | IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt |
PD-9506GC standard 핀 구성 가이드
PD-9506GC(standard 패키지)의 핀 구성입니다. 이 전력 소자는 게이트, 드레인, 소스 단자를 갖추고 있습니다. 비편향 패키지의 경우 정확한 핀 1 방향과 풋프린트 세부 정보는 제조사 데이터시트를 참조하십시오. 일반적인 응용 분야로는 전원 공급 장치 설계, 모터 구동, 부하 스위칭이 있습니다.
다음에 대한 상세 핀아웃 데이터 없음: PD-9506GC.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
PD-9506GC 적합 용도: 6 애플리케이션s: Enterprise Wi-Fi 6/6E Access Point Power, PTZ and Dome Surveillance Cameras, IP Intercoms and Access Control Readers, Digital Signage and Kiosks, Thin Clients and Small-Form-Factor PCs, Conference Room AV-over-IP Endpoints.
Enterprise Wi-Fi 6/6E Access Point Power
The PD-9506GC's 60 W per-port budget delivers the headroom required by tri-radio IEEE 802.11ax Wi-Fi 6 and 6E access points, which draw 35-51 W under full 4x4 MIMO operation. By injecting 55 V DC on each port, the midspan eliminates the need for ceiling-mounted AC outlets, reducing Wi-Fi deployment cost by approximately 30 percent according to industry cabling studies. Each of the six ports powers a separate AP with full mode A + mode B 802.3bt negotiation, ensuring compatibility with Cisco, Aruba, Ruckus, and Juniper Mist APs.
추천
PTZ and Dome Surveillance Cameras
Pan-tilt-zoom (PTZ) and outdoor dome network cameras are among the highest-power PoE loads in surveillance networks, with heater-equipped outdoor PTZ units drawing 30-60 W for heater, motor, and IR illuminator simultaneously. The PD-9506GC's 60 W per-port budget delivers full power even at -40 C ambient on the camera side, including heater warm-up surge. Cabling infrastructure remains Cat5e or Cat6, eliminating the need for outdoor AC conduit runs to camera poles.
추천
IP Intercoms and Access Control Readers
Modern IP intercoms and access-control readers with LCD displays, RFID readers, and door-strike actuators require 25-45 W sustained, which exceeds legacy 802.3at limits. The PD-9506GC elevates each port to 802.3bt Type 4 headroom of 60 W, future-proofing the deployment against feature additions such as face-recognition cameras integrated into the reader. Six ports support a small commercial building's full intercom-and-access-control subsystem from one closet-mounted midspan.
추천
Digital Signage and Kiosks
Interactive digital signage kiosks with touchscreen displays, embedded PCs, and barcode scanners typically draw 35-55 W, which the PD-9506GC handles comfortably on any of its six ports. Running power over a single Cat6 cable eliminates the need for an electrician at each kiosk location, slashing deployment cost in retail and transportation-hub rollouts. The midspan's NMS capability allows remote power-cycling of misbehaving kiosks, reducing field-service truck rolls.
추천
Thin Clients and Small-Form-Factor PCs
USB-C-over-Ethernet thin clients and compact enterprise PCs drawing 45-60 W via PoE are an emerging application enabled by 802.3bt. The PD-9506GC powers up to six such clients per chassis, supporting a small VDI deployment from a single floor-distribution closet. Where Cat6A infrastructure already exists, the PD-9506-10GC variant delivers 10 Gbps data alongside 60 W power, enabling future migration without PoE replacement.
추천
Conference Room AV-over-IP Endpoints
AV-over-IP encoders and decoders for conference rooms (Dante, SDVoE, NDI) increasingly draw 30-50 W to drive their HDMI I/O and DSP subsystems. The PD-9506GC provides 60 W per port with full Gigabit data pass-through, eliminating separate power supplies at each endpoint and reducing under-table cable clutter. The midspan's NMS integrates with corporate AV management platforms for unified visibility into the AV estate.
추천
추천 제품 요약
엔지니어링 참조 데이터: PD-9506GC — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | PD-9606GC | PD-9512GC | PD-9524GC | PD-9506-10GC |
|---|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package / Form Factor | 1U 19-inch rack chassis | 1U 19-inch rack chassis | 1U 19-inch rack chassis | 1U 19-inch rack chassis | 1U 19-inch rack chassis |
| Port Count | 6 | 6 | 12 | 24 | 6 |
| Output Power per Port | 60 W | 60 W | 60 W | 60 W | 60 W |
| Total Aggregate PoE Budget | 360 W | 360 W | 720 W | 1440 W | 360 W |
| PoE Standard | IEEE 802.3bt Type 3/4 | IEEE 802.3bt Type 3/4 | IEEE 802.3bt Type 3/4 | IEEE 802.3bt Type 3/4 | IEEE 802.3bt Type 3/4 |
| Data Rate | 10/100/1000 Mbps | 10/100/1000 Mbps | 10/100/1000 Mbps | 10/100/1000 Mbps | 2.5/5/10 Gbps |
| Network Management | Yes (NMS) | Yes (NMS) | Yes (NMS) | Yes (NMS) | Yes (NMS) |
| Lifecycle Status | Last-Time-Buy (2025-05-20) | Active | Last-Time-Buy | Last-Time-Buy | Active |
| AC Input | 100-240 V AC, 50/60 Hz | 100-240 V AC, 50/60 Hz | 100-240 V AC, 50/60 Hz | 100-240 V AC, 50/60 Hz | 100-240 V AC, 50/60 Hz |
주요 차별점
- True drop-in successor available from same vendor (vs PD-9606GC)
- 10 Gigabit data pass-through option (vs PD-9506-10GC)
- Higher port density variants in same family (vs PD-9512GC)
설계 노트
Estimated: at full 60 W load on all six ports (360 W PoE + 30-50 W conversion losses), the PD-9506GC dissipates approximately 410-440 W of heat through its chassis. In a fully populated 19-inch rack, leave at least 1U of empty rack space above and below the midspan for airflow, and confirm the rack's HVAC can remove this load from a confined closet. For sites running the unit at > 80% port loading continuously, plan for active rack ventilation or an ambient operating temperature derating to 35 C.
Place the PD-9506GC within 100 m cable run of the powered devices; this is the IEEE 802.3bt channel-length limit. For sites exceeding 100 m, install a PoE extender or place the midspan in a wiring-closet closer to the load. Avoid routing PoE cables parallel to fluorescent-light ballast wiring or three-phase power feeders to minimize common-mode noise injection; cross at 90 degrees where crossings are unavoidable.
Do not mix the PD-9506GC output with passive PoE injectors or non-standard 24/48 V splitters on the same cable run - the 55 V PoE voltage can damage PDs expecting 802.3af-class voltage. According to the Microchip datasheet, always verify that the attached PDs are 802.3af/at/bt-compliant before energizing. If the green Link LED does not illuminate within 5 seconds of PD connection, the cable run likely has a pair-to-pair short or excessive DC resistance; replace the run before further troubleshooting.
규정 준수 정보
RoHS and REACH compliance per Microchip product documentation. Not AEC-Q100 applicable - this is an indoor commercial/enterprise PoE midspan, not an automotive-grade component. Last-time-buy notice MFOL-09FGXD587 with ship-by date 2025-10-01.